MAURY USCG vessel records Sign in
← All vessels

SAGACIOUS ID

SAGACIOUS ID is a 1996 freight ship. The Coast Guard has recorded 38 inspections since 1996, most recently in May 2008, along with 28 deficiencies — 1 with no resolution recorded — and 7 operational controls.

Records from 1996 to 2008. Most recent: inspection, 29 May 2008.

Built
1996
Last inspected
29 May 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9117789 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
445594
Flag
PANAMA
—
Maury page id
psix-445594

Inspections, by type

…with no type recorded20
…past their stated due date1
Years with a record 13 calendar years (1996–2008)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it14872 - Convention (Subpart B), Net Ton
26064 - Convention (Subpart B), Gross Ton
53181 - Displacement, Ton
45647 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

29 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3221467
21 May 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3212644
5 May 2008 MARPOL Annex I Examination · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3205717
21 March 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3168878
9 January 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2852864
24 October 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2807317
10 July 2006 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2706855
5 April 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2617324
21 January 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2570669
4 January 2006 MARPOL Annex I Examination · Deficiency Check · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2560226
1 August 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2448415
10 April 2005 ISPS II Exam · PII Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2330521
24 May 2004 Re-Inspection · Ballast Water Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2076625
24 December 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1969351
10 November 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1945210
5 June 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1810242
9 May 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1785238
11 April 2003 Re-Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1770349
2 April 2003 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1767076
2 April 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1778287
10 November 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1699831
12 October 2002 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1685265
18 July 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1648432
3 June 2002 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1625541
7 March 2002 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1488967
11 September 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 293519
21 August 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 293123
13 March 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 288112
18 July 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 279828
10 September 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 432619
30 October 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 422127
6 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419654
29 May 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 108895
26 October 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 409182
18 August 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 687159
11 August 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 510254
15 March 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 400981
9 September 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 395243

Deficiency record · 28

Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 19 May 2008 Resolved
The vessels Echo Depth Sounder is not operating properly. The vessel is required to submit documentation attesting to the proper operation of the Echo Depth Sounder. 33CFR164.35 (h)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2008
Resolution: The vessel submitted documentation attesting to the proper operation of the Echo Depth Sounder.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 5 May 2008 No resolution recorded
Vessels Echo Depth Sounding Device is inoperative. NKK issued a Short Term Conditional Cargo Ship Safety Equipment Certificated to vessel to sail with an inoperable Echo Depth Sounder until 17JUL2008. Subject to the continued proper operation of the No 1 & No 2 Radar, ARPA, GPS, AIS and Safety Radio Equipment. 74 SOLAS V/19.2.3.1 / 33 CFR 164.35(h)
Due 17 July 2008 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 May 2008 Resolved
Vessels Secondary Radar System is inoperative. 74 SOLAS V/19.2.7.1 / 33 CFR 164.37(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2008
Resolution: Received technician’s report attesting to satisfactory operations of the Secondary Radar System.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 5 May 2008 Resolved
Vessel's Voyage Data Recorder Retrievable Unit is transmitting a 121.5 MHz signal while the switch is in the off position. Signal is being received by U.S Coast Guard as a distress signal. NKK issued a Short Term Conditional Cargo Ship Safety Equipment Certificate to vessel to sail with an inoperable VDR until 17JUL2008. 74 SOLAS V/20
Due 17 July 2008
Resolved 29 May 2008
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 10 July 2006 Resolved
Port and Starboard Bridge Wing Rudder Angle Indicators are 3 degrees out of calibration from the Rudder Angle Indicator in the wheelhouse. Send Tech report to Coast Guard.
Action required: 705 - Other - as specified
Resolved 13 July 2006
Resolution: Received technical report from [name withheld] stating deficiency was rectified.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 10 July 2006 Resolved
No. one, two, and three generator exhaust insulation missing, causing a fire and burning hazard. Replace to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 13 July 2006
Resolution: Received class report from NKK stating that the deficiency was rectified.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 4 January 2006 Resolved
The Garbage Plan is not ship specific. Mixed garbage was found throughout the vessel and the containers for food, which according to the plan are blue are instead green.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2006
Resolved 5 April 2006
Resolution: Corrected by the Master and [name withheld].
Lifesaving › Launching Appliances › Release Mechanism
Issued 4 January 2006 Resolved
The hydrostatic devices for the liferafts were not connected correctly. The weak link was by-passed, which would have allowed the rafts to float free without opening, SOLAS III Reg. 38 / 6.2.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2006
Resolved 4 January 2006
Resolution: Instructed the 3/O and 2/O on the proper way to connect the hydrostatic releases.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 4 January 2006 Resolved
The ship's SOLAS training manual is not ship specific as required by SOLAS III Reg. 51. Basic items missing but not limited too correct launching instructions for lifeboats, operation of the lifeboat engines and use of emergency radios.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2006
Resolved 5 April 2006
Resolution: Corrected by the crew under the direction of the Master.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 January 2006 Resolved
The starboard navigation light did not have the correct lamp inside, COREG Rule 22, ANNEX I, and 33 CFR 84.23.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2006
Resolved 4 January 2006
Resolution: Corrected by the 2/O while we were on board.
Lifesaving › Lifebuoys › Not on Board
Issued 4 January 2006 Resolved
Both of the bridge wing buoys were not the correct weight for launching the smoke / light as required by SOLAS III 31/1.7.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2006
Resolved 13 January 2006
Resolution: New buoys were purchased and place on board.
Fire Fighting › Ventilation Systems › Ducts
Issued 4 January 2006 Resolved
Ventilation ducts leading from the main deck into the accommodation house are wasted. All are located on the starboard side deck store #1, deck store #2, fire control station and lower bridge deck closet marked DUCT TRUNK. All must be inspected by a Classification Society Representative. Neither the Master nor C/E has submitted non-conformities regarding these as required by the ships SMS Ch-16.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2006
Resolved 5 April 2006
Resolution: Corrected by the crew under the direction of the Classification Society Representative.
Fire Fighting › Fire Main › Condition
Issued 4 January 2006 Resolved
The fire main expansion coupling located on the starboard side between cargo hold 3 and 4 is leaking excessively, SOLAS I/11.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2006
Resolved 13 January 2006
Resolution: Joint was disconnected by the crew they replaced the rubber packing.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 January 2006 Resolved
The self closing devices for the A0 fire doors leading into the galley are missing. The self closing device and door knob and locking device for the B0 door leading from the Officers mess into the pantry is missing, SOLAS II-2 Reg. 47.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2006
Resolved 5 April 2006
Resolution: Corrected by the crew under the direction of the Master.
Construction/Loadline › Structures › Ventilators
Issued 4 January 2006 Resolved
The ballast vent floats for the #1 aft, #2 aft, #3 aft, #4 aft and #5 aft top side tanks were stuck in the open position. Ballast vent floats for the top side tank port #2 forward and aft were also stuck.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2006
Resolved 4 January 2006
Resolution: These were corrected by the crew under the supervision of the C/O prior to us departing.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 4 January 2006 Resolved
The pressure gauges for the bunker transfer line located on the port and starboard side were wasted.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2006
Resolved 4 January 2006
Resolution: Both of these were replaced by the C/E prior to use departing.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 4 January 2006 Resolved
The sewage system is not being maintained as per the manufacturer's requirements. Daily, weekly, monthly semi annual and annual test and inspections are not being done as outlined in the maintenance manual. In addition the ship does not have the required chlorine test kit on board to check the system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2006
Resolved 5 April 2006
Resolution: Corrected by the crew under the direction of the Master and C/E.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 January 2006 Resolved
The supply and discharge pipes for the air conditioning are patched. In addition the bilge pump has two patches on it. Neither the Master nor the C/E have reported these to the DPA as required by the SMS chapter 16.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2006
Resolved 5 April 2006
Resolution: Corrected by the crew under the direction of the Master. Non-Conformity reports were submitted to DPA.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 January 2006 Resolved
Three (3) of the EEBD's located in the engine room are out of air. The crew can not charge these on board. Recharging of the EEBD's must be done prior to departure. Reference II-2 Reg. 13 / 4.3.1.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2006
Resolved 13 January 2006
Resolution: EEBD''''S were recharged placed back in service.
Lifesaving › Launching Appliances › Davit
Issued 4 January 2006 Resolved
The limit switch for the starboard lifeboat is not working correctly. The spring may be worn or the entire device may need replacing. Reference III Reg. 48 /2.5.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2006
Resolved 5 April 2006
Resolution: Corrected by the crew under the direction of the Master.
Lifesaving › Lifeboat › Stability
Issued 4 January 2006 Resolved
The emergency tiller for both lifeboats are missing. Reference SOLAS III Reg. 41 7.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2006
Resolved 5 April 2006
Resolution: Corrected by the crew under the direction of the Master.
Documentation › Certificates/Documents
Issued 11 April 2003 Resolved
Master's medical certificate shows typographical error. Master to provide proper medical certificate NLT 14MAY03 LEGACY COMPONENT DESC: Medical Certificate
Due 14 May 2003
Resolved 15 May 2003
Deck/Cargo
Issued 7 March 2002 Resolved
Renew missing rail course on port side main deck railing located between cargo hatches #1 and #2.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 June 2002
Resolution: Rail was varified to have been reinserted.
Fire Fighting
Issued 21 August 2001 Resolved
THE VESSELS PAINT LOCKER WAS MISSING A FIXED FIRE FIGHTING SYSTEM, THE VESSEL WAS INSTRUCTED TO PROVIDE A CLASS REPORT PRIOR TO NEXT U.S PORT.
Condition: Unknown
Due 11 September 2001
Resolved 11 September 2001
Fire Fighting
Issued 21 August 2001 Resolved
THE VESSELS VENTS ON THE PAINT LOCKER WERE FROZEN, (COULD NOT OPEN FROM THEOUTSIDE).
Condition: Unknown
Due 11 September 2001
Resolved 11 September 2001
Fire Fighting
Issued 21 August 2001 Resolved
THE FIRE TEAMS WERE NOT PROPERLY DRESSED OUT FOR THE FIRE DRILL, MISSING AXE AND FLASHLIGHT.
Condition: Unknown
Due 21 August 2001
Resolved 21 August 2001
Unknown
Issued 21 August 2001 Resolved
THE VESSELS MUSTER LISTS WERE OUTDATED, THE MASTER WAS ADVISED.
Condition: Unknown
Due 21 August 2001
Resolved 21 August 2001
Documentation
Issued 30 October 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.