← All vessels
JOEY D
Freight Ship · General Dry Cargo Ship class · Built 1960s · USCG Southeast District (CGD-SE) · Other hulls named JOEY D
JOEY D is a 1963 freight ship. The Coast Guard has recorded 43 inspections since 1981, most recently in March 2001, along with 170 deficiencies and 6 operational controls.
Records from 1981 to 2001. Most recent: inspection, 21 March 2001.
- Built
- 1963
- Last inspected
- 21 March 2001
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 170 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
293191
7100718 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCE2419
44577
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-44577
Inspections, by type
…with no type recorded30
Years with a record
19 calendar years (1981–2001)
The 43 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it284 - Convention (Subpart B), Gross Ton
169 - Regulatory (Subpart C or D), Gross Ton
84 - Convention (Subpart B), Net Ton
115 - Regulatory (Subpart C or D), Net Ton
169 - Regulatory (Subpart C or D), Gross Ton
84 - Convention (Subpart B), Net Ton
115 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCE2419MMSI not assigned · expired · compulsorily equipped · granted 22 August 1994, cancelled 23 October 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 43
21 March 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 521092
24 April 2000
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 277732
11 April 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 277166
3 February 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 274412
3 August 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 432459
7 May 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 428486
17 February 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 425716
2 February 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 425167
9 November 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 422489
21 October 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 421787
18 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412938
28 July 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 406240
13 January 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 472172
20 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087802
25 January 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 387279
20 December 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 386107
6 December 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 385664
6 December 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1185971
25 April 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1398232
6 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 697969
19 January 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 132375
21 December 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1465800
4 November 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 218675
4 November 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 227169
6 June 1994
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1468312
4 May 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 697970
3 May 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 30964
22 December 1993
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1159654
28 October 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 831335
3 June 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 163919
6 September 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936546
30 November 1990
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 929431
22 August 1990
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 912213
21 September 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 996130
7 September 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348289
21 July 1987
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1335552
9 December 1986
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1329860
14 May 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1304404
12 September 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1286761
29 May 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280352
5 January 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279290
3 October 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271139
21 November 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276613
Deficiency record · 170
Fire Fighting
Issued 3 February 2000
Resolved
PROVIDE TECHNICIANS REPORT ATTESTING TO THE SATISFACORY OPERATION OF FIRE DETECTION SYSTEM. UNTIL UNIT IS REPAIRED, ENGINE ROOM IS TO BE CHECKED AT INTERVALS NO GREATER THAN 30 MINUTES. UNIT IS TO BE REPAIRED NLT 03APR00.
Documentation
Issued 3 February 2000
Resolved
Indicate on the Caribbean Cargo Safety Certificate whether or not an exemption certificate has or has not been issued NLT 03MAR00.
Navigation
Issued 3 February 2000
Resolved
Provide the following updated publications/charts prior to departure: #25640, #25670, #25649, #25645, and a Coast Guard Light List.
Deck/Cargo
Issued 3 February 2000
Resolved
Evaluate port and stbd anchor chain for wastage. Provide class report attesting that chain is within wear limits for class rules.
Accommodation/Occupational Safety
Issued 3 February 2000
Resolved
Renew holed ladder step treads on ladder from main deck to pilothouse NLT 03MAR00.
Lifesaving
Issued 3 February 2000
Resolved
Post operating instructions for the rescue boat.
Lifesaving
Issued 3 February 2000
Resolved
Prior to departure, replace port and stbd self igniting smoke/lights for liferings.
Fire Fighting
Issued 3 February 2000
Resolved
Repair/remove soft patches in fire main piping in engine room NLT 03MAR00.
Documentation
Issued 3 February 2000
Resolved
Prior to departure provide proof of periodical Loadline Survey which was due in August 1999.
Construction/Loadline
Issued 3 February 2000
Resolved
PROVIDE CLASS REPORT WITNESSING ULTRASONIC GAUGE TESTING OF FORWARD STEERING BLKHD. PROVIDE STATEMENT AS TO THE STRUCTURAL INTEGRITY OF STEERING SPACE RELATING TO MASSIVE WASTAGE OF ALL STRUCTURAL MEMBERS.
Lifesaving
Issued 3 February 2000
Resolved
Prior to departure provide 11 lifejackets with lights, whistles, and retro reflective tape.
Lifesaving
Issued 3 February 2000
Resolved
Prior to departure provide 1 additional distress signal IAW CCSSC 4.4.13.
Fire Fighting
Issued 3 February 2000
Resolved
Prior to departure provide fireman's outfit that meets the requirements of CCSSC Chapter 3.11 and 3.12.
Navigation
Issued 3 February 2000
Resolved
PRIOR TO ENTERING U.S. WATERS, PROVIDE DOCUMENTATION AND STATEMENT FROM MASTER THAT VESSEL IS USING COAST GUARD NOTICE TO MARINERS AND CHARTS HAVE BEEN UPDATED USING THIS PUBLICATION.
Documentation
Issued 3 February 2000
Resolved
Prior to departure, provide valid safety radio telephony certificate.
Documentation
Issued 3 February 2000
Resolved
Prior to departure provide safe manning certificate.
Documentation
Issued 3 February 2000
Resolved
Prior to departure, provide a valid certificate of classification.
Engineering
Issued 3 February 2000
Resolved
Repair port propulsion shaft packing gland. Gland is leaking excessively and has minimal adjustment capability remaining NLT 03MAR00.
Fire Fighting
Issued 3 February 2000
Resolved
Prior to departure renew starting batteries for emergency fire/ballast pump.
Fire Fighting
Issued 3 February 2000
Resolved
Prior to departure renew fire main riser #3.
Construction/Loadline
Issued 3 February 2000
Resolved
Renew gasket on stbd engine room weathertight door.
Construction/Loadline
Issued 3 February 2000
Resolved
Renew gasket on porthole in head, make watertight NLT 03MAR00.
Construction/Loadline
Issued 3 February 2000
Resolved
Prior to departure repair all damage to aft steering compartment. Provide detailed class report of survey of damage and repairs. Report must address ruptured hull, heavy corrosion/wastage and split deck seams.
Navigation
Issued 3 February 2000
Resolved
Prior to departure, repair rudder angle indicator.
Deck/Cargo
Issued 3 February 2000
Resolved
Prior to departure repair port anchor windlass. Demonstrate an unpowered release with control of wildcat brake.
Fire Fighting
Issued 3 August 1999
Resolved
Install missing fire station valve wheel/handle at starboard side prior to departing to the next voyage.
Fire Fighting
Issued 3 August 1999
Resolved
Prove current servicing of paint locker CO2 system.
Lifesaving
Issued 3 August 1999
Resolved
Prove current servicing of liferaft at port side.
Documentation
Issued 3 August 1999
Resolved
Provide satisfactory evidence of minimum safe manning in accordance with the flag administration requirements per issued certificate.
Electrical
Issued 3 August 1999
Resolved
Renew as original the expansion cap on starbaord generator.
Navigation
Issued 3 August 1999
Resolved
Provide working radar required IAW sighted CCSSC record of equipment.
Engineering
Issued 3 August 1999
Resolved
Install 30X30 flame mesh (screen) at starboard fuel line vent aft with suitable clamping mechanism (not plastic) prior to departing to the next voyage.
Electrical
Issued 3 August 1999
Resolved
Replace water cooling system manifold of starboard generator set; already ordered.
Fire Fighting
Issued 7 May 1999
Resolved
PROVIDE FIRE EXTINGUISHER SERVICING REPORT TO USCG PRIOR TO DEPARTING U.S. WATERS.
Navigation
Issued 7 May 1999
Resolved
PRIOR TO NEXT U.S. PORT PROVIDE PROOF THAT TIDES AND CURRENT TABLES HAVE BEEN PROVIDED TO NEAREST USCG MSO.
Navigation
Issued 7 May 1999
Resolved
PROVIDE COPY OF SAILING DIRECTIONS PRIOR TO NEXT U.S. PORT. PROVIDE PROOF OF PURCHASE TO NEAREST USCG MSO.
Documentation
Issued 17 February 1999
Resolved
PRIOR TO DEPARTING US WATERS PROVIDE VALID RADIO OPERATORS PERMIT.
Construction/Loadline
Issued 17 February 1999
Resolved
PROVIDE METHOD TO PREVENT DOWN FLOODING THROUGH PORT AND STBD BALLST TANK VENTS NLT 17 MAR 99.
Unknown
Issued 17 February 1999
Resolved
PROVIDE METHOD TO PREVENT INADVERTANT DRAINING OF BUNKER STATION CONTAINMENT AREA PRIOR TO NEXT BUNKERING.
Documentation
Issued 17 February 1999
Resolved
PROVIDE COPY OF SAILING DIRECTIONS PRIOR TO NEXT U.S. PORT.
Documentation
Issued 17 February 1999
Resolved
PRIOR TO DEPARTING US WATERS PROVIDE VALID CERTIFICATE OF REGISTRY.
Engineering
Issued 17 February 1999
Resolved
RENEW FLAME SCREEN ON STBD SIDE FUEL TANK VENT NLT 17 MAR 99.
Documentation
Issued 17 February 1999
Resolved
PRIOR TO DEPARTING U.S. WATERS PROVIDE LICENSED CHIEF ENGINEER.
Documentation
Issued 17 February 1999
Resolved
PRIOR TO DEPARTING U.S. WATERS PROVIDE LICENSED CHIEF MATE.
Lifesaving
Issued 17 February 1999
Resolved
PRIOR TO DEPARTING U.S. WATERS PROVIDE PROOF OF PROPER OPERATION OF EPIRB AND RENEW HYDROSTATIC RELEASE MECHANISM.
Fire Fighting
Issued 2 February 1999
Resolved
REPAIR PACKING TO VALVE AT FIRE STATION AFT STARBOARD SIDE. VALVE WAS REPACKED AND REPAIRED 03FEB99.
Construction/Loadline
Issued 2 February 1999
Resolved
PROPERLY REPAIR THE SUCTION MANIFOLD ON THE BILGE PUMP. IT HAS A WOODEN PLUG IN CORRODED LINE. CORRECT TO SATISFACTION OF CLASS AND PROVIDE REPORT TO MSO SAN JUAN. REPORT PROVIDED 03FEB99.
Fire Fighting
Issued 21 October 1998
Resolved
REPAIR FIREMAIN PIPE WITH TEMPORARY PATCH LOCATED FORWARD OF STARBOARD OF STARBOARD MAIN ENGINE.
Fire Fighting
Issued 21 October 1998
Resolved
CONDUCT FULL FUNCTION TEST OF EMERGENCY FIRE PUMP.
Unknown
Issued 21 October 1998
Resolved
COMPLETE DEFICIENCIES ISSUED ON PRIOR BOARDING DATED 21 OCT 98 & 18 FEB 98_x001C_TO SATISFACTION OF CG SURVEYOR.
Lifesaving
Issued 21 October 1998
Resolved
CONDUCT PROPER HOUSE KEEPING OF ENGINEROOM.
Electrical
Issued 21 October 1998
Resolved
PROPERLY COVER OPENING TO THE POWER DISTRIBUTION PANEL BOARD.
Electrical
Issued 21 October 1998
Resolved
PROVIDE PROOF OF EMERGENCY POWER CAN SUPPLY 18 HOURS FOR COMMS AND FIRE DETECTOR IAW 2F2.34.5
Documentation
Issued 21 October 1998
Resolved
PROVIDE MANUEVERING INFO SHEET IAW 2G2.36.2
Electrical
Issued 21 October 1998
Resolved
REPAIR PORT ENGINEROOM VENTILATION MOTOR.
Electrical
Issued 21 October 1998
Resolved
PROVIDE LABELING OF VENTILATION EMERGENCY SHUT DOWN SWITCH STARBOARD SIDE.
Unknown
Issued 21 October 1998
Resolved
PROVIDE MEANS OF COMMUNICATION FROM ENGINEROOM & BRIDGE.
Navigation
Issued 21 October 1998
Resolved
PROVIDE PROOF OF PROPER OPERATION OF LOSS OF STEERING POWER ALARM ON BRIDGE
Documentation
Issued 21 October 1998
Resolved
PROVIDE UPDATED DEVIATION TABLE.
Lifesaving
Issued 21 October 1998
Resolved
CONDUCT AND RECORD FIRE AND ABANDON SHIP DRILL IN PRESCENCE OF CG INSPECTOR
Fire Fighting
Issued 21 October 1998
Resolved
PROVIDE APPROVED BY CLASS FIRE CONTROL PLAN.
Fire Fighting
Issued 21 October 1998
Resolved
PROVIDE A FIXED FIRE DETECTION AND ALARM SYSTEM.
Electrical
Issued 21 October 1998
Resolved
PROVIDE EMERGENCY LIGHTING THRUOUT THE SHIP AS PER CCSSC.
Lifesaving
Issued 21 October 1998
Resolved
REMOUNT LIFERAFTS FOR PROPER LAUNCHING.
Accommodation/Occupational Safety
Issued 21 October 1998
Resolved
PROVIDE QUICK REMOVE DESIGN OF VENT CLOSURE DOORS LOCATED INSIDE PORT AND STARBOARD SIDE STAIRWAY.
Lifesaving
Issued 21 October 1998
Resolved
PROVIDE EMERGENCY EXIT MARKINGS TO PORT & STBD ENGINEROOM ACCESS STAIRWAYS IN ENGINEROOM.
Construction/Loadline
Issued 21 October 1998
Resolved
REPAIR AND ADJUST STARBOARD DECK WATERTIGHT DOOR AND DOGS.
Engineering
Issued 21 October 1998
Resolved
CONDUCT FUNCTION TEST OF FUEL SHUTOFF REACHROD VALVES IN ENGINEROOM FROM DECK.
Fire Fighting
Issued 21 October 1998
Resolved
REPLACE FIRE EXTINGUISHER LOCATED STARBOARD SIDE OF BALLAST PUMP
Fire Fighting
Issued 21 October 1998
Resolved
PROVIDE PROPER FIRE EXTINGUISHER MOUNT FOR SJ15.
Electrical
Issued 21 October 1998
Resolved
REPLACE FUEL LINES FROM STARBOARD GENERATOR.
Engineering
Issued 21 October 1998
Resolved
REPLACE AFT CLAMP TO STARBOARD ENGINE TURBO.
Fire Fighting
Issued 21 October 1998
Resolved
PROPERLY MOUNT STARBOARD SIDE FIRE EXTINGUISHER IN STAIRWAY TOWARD ENGINEROOM.
Lifesaving
Issued 21 October 1998
Resolved
PROVIDE 6 UPDATED PARACHUTE DISTRESS SIGNALS.
Lifesaving
Issued 21 October 1998
Resolved
PROVIDE PROPER ILUMINATION AT LIFERAFT LAUNCHING STATIONS.
Electrical
Issued 21 October 1998
Resolved
REPAIR LOW LUBE OIL SHUT-DOWN TO STARBOARD GENERATOR.
Engineering
Issued 21 October 1998
Resolved
PROVIDE AND TEST OVERSPEED AND LOW LUBE OIL SHUT-DOWNS TO THE MAIN DIESEL ENGINES.
Navigation
Issued 18 February 1998
Resolved
PROVIDE CURRENT TIDE TABLES.
Documentation
Issued 18 February 1998
Resolved
PROVIDE PROPER MANNING FOR SHIP.
Lifesaving
Issued 18 February 1998
Resolved
PROVIDE FOUR LIFEJACKETS IN GOOD CONDITION.
Lifesaving
Issued 18 February 1998
Resolved
SHOW PROOF OF LAST HYDRO ON LIFERAFTS.
Navigation
Issued 18 February 1998
Resolved
OBTAIN DAYLIGHT SIGNALLING LIGHT.
Documentation
Issued 18 February 1998
Resolved
LOADLINE NOT PROPERLY MARKED.
Fire Fighting
Issued 18 February 1998
Resolved
REPAIR FIRE STATION #2 HYDRANT VALVE.
Fire Fighting
Issued 18 February 1998
Resolved
REPAIR BROKEN HYDRANT HANDLE TO FIRE STATION #3 STARBOARD SIDE.
Fire Fighting
Issued 18 February 1998
Resolved
PROVIDE PROPER INSTALLATION OF FIXED CO2 EQUIPMENT TO PAINT LOCKER.
Engineering
Issued 18 February 1998
Resolved
PROVIDE ENGINE TACHOMETERS TO ENGINES IN ENGINE ROOM.
Engineering
Issued 18 February 1998
Resolved
PROVIDE EMERGENCY SHUTDOWN TO MAIN ENGINE FROM BRIDGE.
Lifesaving
Issued 18 February 1998
Resolved
PROVIDE REQUIRED RESCUE BOAT AND WINCHES, DAVITS.
Lifesaving
Issued 18 February 1998
Resolved
SHOW PROOF OF EXTENTION OF LIFERAFT INSPECTION W/CLASS SOCIETY.
Fire Fighting
Issued 18 February 1998
Resolved
PROVIDE FIRE CONTROL PLAN APPROVED BY CLASS.
Engineering
Issued 18 February 1998
Resolved
INSTALL OVERSPEED EQUIPMENT TO THE MAIN & GENERATOR ENGINES.
Electrical
Issued 18 February 1998
Resolved
REPAIR SOUND POWER PHONE SYSTEM.
Navigation
Issued 18 February 1998
Resolved
PROVIDE MEANS OF EMERGENCY GEAR STEERING.
Fire Fighting
Issued 18 February 1998
Resolved
INSTALL EMERGENCY AND FIRE PUMP AND HAVE THEM PROPERLY WORKING.
Engineering
Issued 18 February 1998
Resolved
CONDUCT FULL FUNCTION TEST OF STARBOARD ENGINE.
Engineering
Issued 18 February 1998
Resolved
PROVIDE HP RATING OF MAIN DIESEL ENGINES.
Documentation
Issued 18 February 1998
Resolved
PROVIDE RADIO, IOPP, CONSTRUCTION CERTIFICATE TO LOCAL U.S. COAST GUARD.
Documentation
Issued 18 February 1998
Resolved
PROVIDE PROPER MEDICAL EXAMINATION FOR CREW.
Navigation
Issued 18 February 1998
Resolved
PROVIDE UPDATED DEVIATION TABLE.
Deck/Cargo
Issued 18 February 1998
Resolved
INSTALL ANCHOR.
Electrical
Issued 18 February 1998
Resolved
PROVIDE EXPLOSION PROOF LIGHT FIXTURE IN PAINT LOCKER.
Deck/Cargo
Issued 18 February 1998
Resolved
INSTALL SECONDARY CHAIN & ANCHOR.
Lifesaving
Issued 18 February 1998
Resolved
PROVIDE APPROVED RESCUE BOAT I.A.W. CCSS CODE.
Fire Fighting
Issued 18 February 1998
Resolved
REINSTALL & TEST MAIN FIRE PUMP.
Fire Fighting
Issued 18 February 1998
Resolved
PROVIDE FIREMAN'S OUTFIT W/SPARE AIR BOTTLE I.A.W. CCSS CODE.
Electrical
Issued 18 February 1998
Resolved
PROVIDE EMERGENCY LIGHTING EQUIPMENT I.A.W. CCSS CODE.
Electrical
Issued 18 February 1998
Resolved
PROVIDE EMERGENCY POWER SOURCE I.A.W. 2.34.5 & 2.34.6.
Fire Fighting
Issued 18 February 1998
Resolved
PROVIDE FIXED FIRE DETECTION SYSTEM.
Engineering
Issued 18 February 1998
Resolved
CONDUCT FULL FUNCTION TEST OF ALL MACHINERY ENGINE MONITERING SYSTEMS.
Engineering
Issued 18 February 1998
Resolved
PROVIDE CLOSURE STOP MAIN EXHAUST TOWER TO PORT & STARBOARD VENT STACKS (SMALLER VENTS).
Engineering
Issued 18 February 1998
Resolved
PROVIDE GASKETS TO PORT & STARBOARD VENT DOOR CLOSURES IN EXHAUST STACK TOWERS.
Construction/Loadline
Issued 18 February 1998
Resolved
CLEAN BILGES IN ENGINE ROOM.
Electrical
Issued 18 February 1998
Resolved
PROVIDE PROPER BLANKS TO OPENINGS IN MAIN POWER DISTRIBUTION PANEL.
Navigation
Issued 18 February 1998
Resolved
PROVIDE JAM NUTS TO RUDDER PACKING GLAND STUDS.
Construction/Loadline
Issued 18 February 1998
Resolved
RENEW/REPLACE DOOR-HATCH & HINGES TO PAINT LOCKER. _x001C_ _x001C_ .
Deck/Cargo
Issued 18 February 1998
Resolved
REPLACE STARBOARD ANCHOR CHAIN.
Unknown
Issued 28 July 1997
Resolved
PROVIDE PROOF OF AN APPLICATION FOR A CSSC CERTIFICATE FROM FLAG STATE. 1JAN98, VSL IS TO HAVE A VALID CSSC CERTIFICATE.
Fire Fighting
Issued 6 December 1995
Resolved
PACKING GLAND LEAKING ON FIRE PUMP MAIN VALVE.
Documentation
Issued 6 December 1995
Resolved
VESSEL IS SHORT ONE LICENSED MATE._x001C_ _x001C_ _x001C_ 46 USC 8301
Documentation
Issued 6 December 1995
Resolved
VESSELS CERTIFICATE OF REGISTRY HAD EXPIRED.
Construction/Loadline
Issued 6 December 1995
Resolved
WASTED STEEL IN DECK HOUSES TO PORT AND STARBOARD MACHINERY SPACE.
Navigation
Issued 6 December 1995
Resolved
SHIPS BELL INOP.
Construction/Loadline
Issued 6 December 1995
Resolved
ROPE LOCKER HATCH MISSING DOGS.
Construction/Loadline
Issued 6 December 1995
Resolved
PROPERLY MARK BILGE REMOTE SHUT OFF PUMP CONTROLS.
Engineering
Issued 6 December 1995
Resolved
MARK FUEL OIL PUMP REMOTE SHUT OFF PUMP CONTROLS.
Electrical
Issued 6 December 1995
Resolved
BATTERY BOXES MISSING COVERS.
Lifesaving
Issued 6 December 1995
Resolved
VESSEL IS SHORT ONE ROCKET PARACHUTE FLARE.
Documentation
Issued 6 December 1995
Resolved
VESSELS LOADLINE CERTIFICATE IS INVALID DUE TO FLAG STATE CHANGE FROM U.S. TO ST. VINCENT & THE GRENIDINES.
Electrical
Issued 6 December 1995
Resolved
DISTRIBUTION PANEL MISSING COVER.
Construction/Loadline
Issued 6 December 1995
Resolved
WATERTIGHT DOORS ARE NOT PROPERLY MARKED.
Construction/Loadline
Issued 6 December 1995
Resolved
WATERTIGHT DOORS TO MACHINERY SPACES NEED REPAIRS.
Fire Fighting
Issued 25 April 1995
Resolved
Prove proper operation of installed fire pump.
Fire Fighting
Issued 25 April 1995
Resolved
Provide additional 50 foot section of fire hose as required by COI for a total of 250 feet of hose prior to operation of ship.
Electrical
Issued 25 April 1995
Resolved
Prove proper operation of emergency lighting system and mark all emergency lighting fixtures prior to operation of ship.
Lifesaving
Issued 25 April 1995
Resolved
Remove open containers of lubricating oil from engine room.
Construction/Loadline
Issued 25 April 1995
Resolved
Remove accumulation of oil and fuel from engine room bilges.
Engineering
Issued 25 April 1995
Resolved
Repair leaky corner in centerline battery box, engine room; and provide dripproof covers for all battery boxes in engine room.
Engineering
Issued 25 April 1995
Resolved
Attach all battery wiring using approved methods.
Electrical
Issued 25 April 1995
Resolved
Replace missing covers from main engine room electrical distribution panel and throughout engine room.
Electrical
Issued 25 April 1995
Resolved
Remove loose wiring throughout engine room.
Fire Fighting
Issued 25 April 1995
Resolved
Service and properly install all hand portable fire extinguishers.
Lifesaving
Issued 25 April 1995
Resolved
Remove or properly store paint containers located outside of paint locker.
Engineering
Issued 25 April 1995
Resolved
Repair all leaks and prove fluid tight integrity of all sea water piping, fittings and valves in engine room prior to operation of ship.
Navigation
Issued 25 April 1995
Resolved
Have Compass swung to satisfaction of local OCMI prior to operation of ship.
Lifesaving
Issued 25 April 1995
Resolved
Provide all information relevant to 16 MAR 95 incident where vsl lost propulsion from both engines and was adrift in waters around Culebra.
Lifesaving
Issued 25 April 1995
Resolved
Provide all information relevant to 15 MARCH 95 incident where Master was ordered by company owner to sail short without prior CG notification or approval.
Electrical
Issued 25 April 1995
Resolved
Prove proper operation of port generator prior to operation of ship.
Engineering
Issued 25 April 1995
Resolved
Prove proper operation of both engines prior to operation of ship.
Lifesaving
Issued 25 April 1995
Resolved
Install proper amount of retroreflective tape on port bridge lifering priorto operation of ship.
Lifesaving
Issued 25 April 1995
Resolved
Provide all information relevant to 23 FEB incident where A/B was fired forbeing intoxicated.
Lifesaving
Issued 25 April 1995
Resolved
Prove proper operation of all life jacket lights; ensure all jackets have proper amount of retro-reflective material, and stow in properly labelled locations.
Lifesaving
Issued 25 April 1995
Resolved
Install stbd main deck lifering in float free location prior to operation of ship.
Lifesaving
Issued 25 April 1995
Resolved
Provide one red parachute flare for a total of 12 as required by 46 CFR 94-90 and by COI prior to operation of ship.
Lifesaving
Issued 25 April 1995
Resolved
Provide and install approved rescue boat in accordance with COI prior to operation of ship.
Engineering
Issued 25 April 1995
Resolved
Double clamp all flexible hose connections in sea water cooling systems throughout engine room prior to operation of ship.
Electrical
Issued 25 April 1995
Resolved
Prove proper operation of both diesel generators under load for 2 hours in presence of Coast Guard marine inspector prior to operation of ship.
Engineering
Issued 25 April 1995
Resolved
Prove proper operation of both fuel oil valve remote reach rods.
Lifesaving
Issued 25 April 1995
Resolved
Install protective guard around centerline pump crankshaft pulley.
Construction/Loadline
Issued 21 December 1994
Resolved
Replace as original sounding tubes in port and starboard fuel tanks.
Construction/Loadline
Issued 21 December 1994
Resolved
Replace entire transverse bulkhead in way of port and starboard fuel tanks.
Electrical
Issued 21 December 1994
Resolved
Remove or repair frayed wiring in engine room.
Construction/Loadline
Issued 21 December 1994
Resolved
Vee and weld indicated broken welds in lazarette along below deck stringer #2 and below deck web.
Construction/Loadline
Issued 21 December 1994
Resolved
Conduct non-destructive test of aft transverse bulkhead repair in the presence of Coast Guard Marine Inspector.
Lifesaving
Issued 6 June 1994
Resolved
Conduct fire drill and man overboard drill in the presence of a Coast GuardMarine Inspector.
Electrical
Issued 6 June 1994
Resolved
Install an emergency light at exit to quarters label all emergency lights.
Lifesaving
Issued 6 June 1994
Resolved
PLACE TWO ADDITIONAL LIFE PRESERVERS ON BOARD FOR A TOTAL OF 10. THEY SHOULD BE STOWED IN THE PILOT HOUSE READILY ACCESSABLE TO THE CREW ON WATCH.
Documentation
Issued 21 July 1987
Resolved
PROVIDE A CURRENT CERTIFICATE OF RESPONSIBILITY FOR VESSEL.
Documentation
Issued 21 July 1987
Resolved
PROVIDE AN FCC SAFETY CERTIFICATE FOR VESSEL.
Fire Fighting
Issued 21 July 1987
Resolved
CONDUCT A FIRE AND BOAT DRILL WITHIN 24 HOURS OF THE CREW REPORTING ABOARD.NOTIFY [name withheld], IN WRITING WHEN THIS REQUIREMENT IS COMPLETED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.