Records from 1981 to 2002. Most recent: inspection, 10 January 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
10 January 2002
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1477408
25 July 1995
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 881897
21 January 1993
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1465096
14 September 1992
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1428153
29 April 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 961148
27 December 1991
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 475474
12 October 1991
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 937627
1 September 1990
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 920858
31 August 1990
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 921921
27 August 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 906987
16 October 1989
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1037084
29 August 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198231
24 July 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1037934
14 November 1988
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1205165
3 June 1988
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 890453
6 November 1987
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1028577
6 October 1987
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1329723
29 January 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 986553
10 January 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 989893
10 January 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 990103
30 December 1985
MARPOL Annex I Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 988786
7 May 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 989880
19 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284478
27 August 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 969285
20 May 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 966564
17 May 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1272710
21 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273638
Engineering
Issued 14 September 1992
Resolved
Hydro port and starboard boiler to 125% MAWP prior to reactivation of vessel.
Condition: Unknown
Due 14 September 1994
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Engineering
Issued 14 September 1992
Resolved
Set and seal safety rerlief valves upon reactivation of vessel.
Condition: Unknown
Due 14 September 1994
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Lifesaving
Issued 14 September 1992
Resolved
conduct fire and boat drills after crew reports onboard for reactivation.
Condition: Unknown
Due 14 September 1994
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Navigation
Issued 12 October 1991
Resolved
REMOVE UNAPPROVED NAVIGATION LIGHT BULBS & FIXTURES AND INSTALL APPROVED ONES.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Construction/Loadline
Issued 12 October 1991
Resolved
REPLACE THE FIRST TWO LEAF GASKETS ON THE #3 HATCH COVER.
Condition: Unknown
Due 31 December 1992
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Fire Fighting
Issued 27 August 1990
Resolved
PROVIDE TWO FLAME SAFETY LAMPS FOR EMERGENCY GEAR LOCKERS
Condition: Unknown
Due 27 August 1990
Resolved 27 August 1990
Deck/Cargo
Issued 27 August 1990
Resolved
PROVIDE FOUR PROJECTILES FOR THE LINE THROWING GUN, TWO OF WHICH MUST BE BUOYANT. TO BE COMPLETED PRIOR TO DEPARTURE FROM NEXT PORT.
Condition: Unknown
Due 27 August 1990
Resolved 27 August 1990
Fire Fighting
Issued 27 August 1990
Resolved
RECHARGE FIRE EXTINGUISHERS #20,26,29,32,24,28. TO BE COMPLETED PRIOR TO DEPARTURE FROM NEXT PORT. SPARES ARE TO BE MAINTAINED ON STATION UNTIL COMPLETED.
Condition: Unknown
Due 27 August 1990
Resolved 27 August 1990
Lifesaving
Issued 16 October 1989
Resolved
CONDUCT WEIGHT TESTS OF LIFEBOATS AND LIFEBOATS DAVITS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
REPROVISION, SERVICE AND PROPERLY STATION APPROVED LIFERAFTS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Accommodation/Occupational Safety
Issued 16 October 1989
Resolved
PROVE OPERATION OF REQUIRED MARINE SANITATION DEVICE.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Navigation
Issued 16 October 1989
Resolved
PROVE OPERATION OF ENGINE ORDER TELEGRAPH, EOT FAILURE ALARM, AND 1JV PHONECIRCUIT.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
PROVE LIFEBOAT WINCHES INCLUDING LIMIT SWITCHES, MASTER SWITCH AND EMERGENCY DISCONNECT.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Accommodation/Occupational Safety
Issued 16 October 1989
Resolved
TEST REMOTE SHUTDOWNS FOR ENGINEROOM VENTILATION, FORCED DRAFT FANS, FUEL OIL PUMPS, AND CARGO SPACE FANS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
PROVIDE APPROVED LIFESAVING EQUIPMENT, AS REQUIRED, INCLUDING: LIFEBOAT PROVISIONS, LIFE PRESERVERS, RING BUOYS, LINE THROWING APARATUS, LIFEBOAT RADIO, EPIRB, AND EXPOSURE SUITS
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
PROVIDE FOR INSPECTION OF ALL EMERGENCY EQUIPMENT.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
INSPECT AND TEST REMOTE CONTROLS TO POWER VENTILATION AND MECHANICAL VENT CLOSURES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
TEST ALL NAVIGATION LIGHTS AND ELECTRONIC NAVIGATION EQUIPMENT.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
PROVIDE ALL REQUIRED NAVIGATIONAL CHARTS AND PUBLICATIONS, REQUIRED FORMS AND NOTICES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
PROVIDE FOR INSPECTION AND TESTING OF HULL AND DECK FITTINGS AS FOLLOWS: VALVES AND CONTROLS FOR BILGE WELLS, COFFEDAMS AND SUCTIONS; DECK OPENINGS/CLOSURES; CARGO GEAR; WATERTIGHT DOOR AND SIDE PORTS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
PROVIDE HOSPITAL AND FIRST AID EQUIPMENT.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
CONDUCT FIRE AND BOAT DRILLS IN PRESE3NCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Fire Fighting
Issued 16 October 1989
Resolved
PROVE OPERATION OF REQUIRED FIRE PUMPS, RELIEF VALVES AND CONTROLS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Navigation
Issued 16 October 1989
Resolved
PROVIDE OIL TRANSFER PROCEDURES AND OIL RECORD BOOK.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Accommodation/Occupational Safety
Issued 16 October 1989
Resolved
PROVE OPERATION OF DISTILLING PLANT AND POTABLE WATER PUMPS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
PROVE PERATION OF LUBE OIL SERVICE PUMPS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Electrical
Issued 16 October 1989
Resolved
TEST OPERATION OF SERVICE GENERATORS- INCLUDING OVERSPEED TRIPS, LOW LUBE OIL PRESSURE TRIPS, LOW LUBE OIL PRESSURE ALARMS, REVERSE POWER TRIPS, PARALLEL OPERATIONS, AND VOLTAGE REGULATIONS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Deck/Cargo
Issued 16 October 1989
Resolved
REPAIR CARGO BOOM RESTS BY STARBOARD ANCHOR WINDLASS AND AT AFTER DECK HOUSE AND #1, #2, #3, AND #4 RESISTOR HOUSES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
TEST OPERATION ON MAIN PROPULSION SAFETY DEVICES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Electrical
Issued 16 October 1989
Resolved
PROVE PROPER OPERATION OF EMERGENCY BATTERIES AND THEIR CHARGING SYSTEMS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Electrical
Issued 16 October 1989
Resolved
TEST GROUND FAULT DETECTORS ON MAIN AND EMERGENCY SWITCHBOARDS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
PROVE PROPER OPERATION OF BOILER AUTOMATIC FEATURES PER APPROVED PROCEDURES
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Electrical
Issued 16 October 1989
Resolved
PROVE PROPER OPERATION OF ALARMS AND TRIPS ON EMERGENCY GENERATOR.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
MAKE PORT AND STARBOARD BOILERS AVAILIBLE FOR EXAMINATION OF FIRESIDES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
CONDUCT HYDROSTATIC TEST OF EACH BOILER FOR CREDIT AND REQUIRED MAIN AND AUXILIARY STEAM PIPING.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
SET AND SEAL STEAM DRUM AND SUPERHEATER SAFETY VAVLES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
OPERATE FUEL OIL SERVICE AND TRANSFER PUMPS AND TEST REMOTE CONTROL SHUTDOWNS FOR SAME.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
OPERATE UNDER A LOAD AND TEST SAFETY DEVICES OF EACH FEEDWATER PUMP.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Accommodation/Occupational Safety
Issued 16 October 1989
Resolved
MAKE AVAILIBLE FOR INTERNAL EXAMINATION/HYDROSTATIC TEST EACH UNFIRED PRESSURE VESSEL AND PROVE SETTING OF RELIEF VALVES ON SAME
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Deck/Cargo
Issued 16 October 1989
Resolved
PROVE OPERATION OF BILGE PUMPS AND ANY REMOTE START OR STOP SWITCHES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Accommodation/Occupational Safety
Issued 16 October 1989
Resolved
PROVE OPERATION OF AIR COMPRESSORS, AIR CONDITIONING AND REFRIGERATION SYSTEMS.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Construction/Loadline
Issued 16 October 1989
Resolved
REPAIR GUARD RAILS AND STANTIONS WHERE DETERIORTED.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Construction/Loadline
Issued 16 October 1989
Resolved
RENEW OR REPAIR MISSING OR DAMAGED HATCH COVERS CLOSING DEVICES.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
RENEW DAVIT ARM STOPPER STARBOARD AFT DAVIT ARM.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
PROVIDE ONE ADDITIONAL SKATE FOR EACH LIFEBOAT
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Construction/Loadline
Issued 29 August 1989
Resolved
REPLACE OR REPAIR 3 MISSING DOGS ON SCUTTLE FOR #4 CARGO HOLD.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Accommodation/Occupational Safety
Issued 29 August 1989
Resolved
REPLACE BUSTED BOLT ON DECK LADDER STBD SIDE LEADING TO BOAT DECK.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Construction/Loadline
Issued 29 August 1989
Resolved
REPLACE STIFFENERS LOCATED ON STBD SIDE WHERE MOTORS ARE MOUNTED THAT SERVICE #3 & 2 CARGO BOOMS MAIN DECK.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Construction/Loadline
Issued 29 August 1989
Resolved
ROLLER LOCATED PORTSIDE AFT HAS A CRACKED WELD IN WAY OF CENTER ROLLER. REPAIR SAME.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Construction/Loadline
Issued 29 August 1989
Resolved
REPAIR OR RENEW ALL 5 CARGO HOLD DOGS FOR LOWER CARGO BAY AREA SCUTTLE.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Construction/Loadline
Issued 29 August 1989
Resolved
REPAIR #4 CARGO HOLD HATCH. IT FAILS LIGHT LEAKNESS TEST FORWARD PORTSIDE.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989