MAURY USCG vessel records Sign in
← All vessels

BAVARIA

BAVARIA is a 1996 freight ship. The Coast Guard has recorded 24 inspections since 1996, most recently in February 2010, along with 3 deficiencies and 1 operational control.

Records from 1996 to 2010. Most recent: inspection, 18 February 2010.

Built
1996
Last inspected
18 February 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9116797 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
445815
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-445815

Inspections, by type

…with no type recorded11
Years with a record 13 calendar years (1996–2010)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2532 - Convention (Subpart B), Gross Ton
1351 - Convention (Subpart B), Net Ton
3579 - Dead Weight, Ton
4936 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

18 February 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3681542
21 May 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3210692
7 November 2007 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3094769
12 March 2007 PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2886087
6 December 2005 ISPS III Exam · PII Safety Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2546661
24 November 2005 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2539098
3 April 2005 Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2325430
3 April 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2325437
30 August 2004 ILO-147 Exam · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2180887
24 July 2003 Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1856096
16 June 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1818602
4 September 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1670829
29 April 2002 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1610487
5 November 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 464558
5 September 2001 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 293158
21 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283252
26 August 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 431970
19 August 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 431904
26 June 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 417019
8 June 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 526764
8 January 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 522201
27 November 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 467964
20 October 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 512243
11 September 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 395263

Deficiency record · 3

Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 12 March 2007 Resolved
Emerg.generator start battery not holdinga charge, EDG not capable of automatic start as required. Provide power source (battery) to ensure automatic starting of EDG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2007
Resolution: Battery replaced during exam.
Lifesaving › Inflatable Liferafts
Issued 16 June 2003 Resolved
All infaltable liferafts were not on board the vessel at the time of inspection due to servicing. Solas 74/78, Ch. III, Reg. 26.1.1.2. Correct prior to departure from port and provide receipt of service to MSO Philadelphia.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2003
Resolution: Received a faxed copy of the report of service from the ship''''s agent attesting to the service and return of the liferafts.
Engineering
Issued 5 September 2001 Resolved
MARPOL ANNEX 1/REG. 16.5: 15PPM ALARM TO OILY WATER SEPARATOR INOPERABLE.
Condition: Unknown
Due 7 September 2001
Resolved 29 April 2002
Resolution: Witnessed proper operation of OWS and alarm.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.