MAURY USCG vessel records Sign in
← All vessels

BLUE SEA II

BLUE SEA II is a 1963 passenger vessel (uninspected). The Coast Guard has recorded 46 inspections since 1985, most recently in January 2008, along with 78 deficiencies.

Records from 1985 to 2008. Most recent: inspection, 2 January 2008.

Built
1963
Last inspected
2 January 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WO6281
Flag
UNITED STATES
—
Maury page id
psix-44593

Inspections, by type

…with no type recorded5
Years with a record 21 calendar years (1985–2008)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WO6281MMSI not assigned · expired · compulsorily equipped · granted 15 July 1997, cancelled 1 December 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 46

2 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3125837
11 January 2005 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2272558
21 January 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1989159
21 January 2003 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1732779
3 December 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1713452
15 July 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1646379
17 January 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1479425
8 March 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1060089
9 January 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1369966
20 January 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1463543
3 February 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1125168
20 January 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1472746
28 November 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1416786
4 March 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1118601
23 January 1998 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1114133
4 March 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1093997
4 February 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1458381
13 January 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098799
20 March 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885882
24 January 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1188335
17 January 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187691
7 August 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 878551
27 February 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1167574
18 January 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 834092
18 January 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1160688
4 January 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1420834
27 October 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1262605
7 May 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1262370
30 October 1991 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1252639
16 October 1991 Re-Inspection · Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1249054
19 October 1990 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1233612
8 September 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1241557
27 March 1990 Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1212663
3 October 1989 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1327413
24 October 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 889153
28 September 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1044400
21 January 1988 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1321242
5 October 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1313626
24 July 1987 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1021161
4 June 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1334807
15 October 1986 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1317286
26 November 1985 Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1295284
26 November 1985 Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1295772
7 October 1985 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 995546
18 June 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1290688
26 March 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1290685

Deficiency record · 78

Engineering › Bilge Water Management System › Piping
Issued 21 January 2004 Resolved
Repair bilge piping where leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2004
Resolved 23 January 2004
Engineering › Bilge Water Management System › Not Installed
Issued 21 January 2004 Resolved
Provide an operable portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2004
Resolved 23 January 2004
Lifesaving › Hand Flares › Expired
Issued 21 January 2004 Resolved
Provide 6 orange smoke flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2004
Resolved 23 January 2004
Personnel › Training › Safety Orientation
Issued 21 January 2004 Resolved
Provide records of training and drills and new hire training.
Due 21 February 2004
Resolved 23 January 2004
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 21 January 2004 Resolved
Provide bouyant line for float lights.
Due 21 February 2004
Resolved 23 January 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 January 2004 Resolved
Provide log of EPIRB monthly testing.
Due 21 February 2004
Resolved 23 January 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 January 2004 Resolved
Provide log of maintence of bouyant apparatice.
Due 21 February 2004
Resolved 23 January 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 January 2004 Resolved
Provide a complete first aid kit.
Due 21 February 2004
Resolved 23 January 2004
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 21 January 2003 Resolved
Repair port engine jacket water leak near expansion tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2003
Resolved 22 January 2003
Resolution: Tightened hose clamp.
Engineering › Fuel Oil Service System › Valve
Issued 21 January 2003 Resolved
Repair/renew port engine fuel return valve handle.
Condition: Improper/Lack of Maintenance
Due 24 January 2003
Resolved 22 January 2003
Resolution: Installed new handle.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 21 January 2003 Resolved
Install operational tachometers on port and starboard main engines. LEGACY COMPONENT DESC: Tachometer
Condition: Unknown
Due 24 January 2003
Resolved 21 January 2004
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 January 2003 Resolved
Post engine room fixed fire extinguishing sytem operating instructions. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Improper/Lack of Maintenance
Due 24 January 2003
Resolved 21 January 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 January 2003 Resolved
Install engine guards. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Due 24 January 2003
Resolved 21 January 2004
Fire Fighting › Ventilation Systems › Ducts
Issued 21 January 2003 Resolved
Make available engine room vent covers.
Condition: Improper/Lack of Maintenance
Due 24 January 2003
Resolved 22 January 2003
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 January 2003 Resolved
Repair compass light, until repaired, restricted to day light operations only.
Condition: Placed in Improper Service
Due 24 January 2003
Resolved 22 January 2003
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 21 January 2003 Resolved
Keep sewage overboard valve locked inside three nautical miles.
Condition: Improper/Lack of Maintenance
Due 24 January 2003
Resolved 22 January 2003
Construction/Loadline › Structures
Issued 3 December 2002 Resolved
Renew/repair deck supports number 5 & 6 located in fuel tank compartment on port side, where attached to deck clamps. LEGACY COMPONENT DESC: Deck supports
Condition: Unknown
Due 18 December 2002
Resolved 30 December 2002
Construction/Loadline › Structures
Issued 3 December 2002 Resolved
Renew/repair port side fuel tank supports, aft end of tank. LEGACY COMPONENT DESC: Fuel tank supports
Condition: Improper/Lack of Maintenance
Due 18 December 2002
Resolved 30 December 2002
Construction/Loadline › Structures
Issued 3 December 2002 Resolved
Renew/replace fwd eng room, port side deck support, no less than seven feet with a sister support. LEGACY COMPONENT DESC: Deck deck support
Condition: Improper/Lack of Maintenance
Due 18 December 2002
Resolved 30 December 2002
Construction/Loadline › Structures
Issued 3 December 2002 Resolved
Repair/renew deck support frame 12 in aft end of eng room. LEGACY COMPONENT DESC: Deck support
Condition: Improper/Lack of Maintenance
Due 18 December 2002
Resolved 30 December 2002
Construction/Loadline › Structures
Issued 3 December 2002 Resolved
Renew/replace frame 13 starbord side eng room aft end. LEGACY COMPONENT DESC: Deck support
Condition: Improper/Lack of Maintenance
Due 18 December 2002
Resolved 30 December 2002
Construction/Loadline › Hull
Issued 3 December 2002 Resolved
Renew/replace fasteners on frame knees in forward compartment port side, numbers 3,4,5,6. LEGACY COMPONENT DESC: Frame knees
Condition: Improper/Lack of Maintenance
Due 18 December 2002
Resolved 30 December 2002
Construction/Loadline › Hull
Issued 3 December 2002 Resolved
Repair/renew hull planking area just above aft bilge overboard penetration on port side. IAW NVIC 7-95. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Due 18 December 2002
Resolved 30 December 2002
Construction/Loadline › Hull
Issued 3 December 2002 Resolved
Renew/repair hull planking on forward port bow near aft bilge penetration. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Due 18 December 2002
Resolved 30 December 2002
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 December 2002 Resolved
Renew/replace hose on port and starboard fuel oil fill connections.
Condition: Improper/Lack of Maintenance
Due 18 December 2002
Resolved 21 January 2004
Stability › Watertight Integrity
Issued 17 January 2002 Resolved
Replace forepeak scuttle gasket LEGACY COMPONENT DESC: Scuttle gasket
Due 28 February 2002
Resolved 1 February 2002
Operations/Management › Drug and Alcohol Testing
Issued 17 January 2002 Resolved
Add deck hand to drug program. LEGACY COMPONENT DESC: Employee Coverage
Due 8 February 2002
Resolved 15 July 2002
Personnel › Training
Issued 17 January 2002 Resolved
Provide CPR card for 50% of crew. LEGACY COMPONENT DESC: First Aid/CPR
Due 16 February 2002
Resolved 15 July 2002
Construction/Loadline › Hull
Issued 17 January 2002 Resolved
Provide wood marine surveyor's report addressing Stbd rudder post damage, #4 bulkhead and floor timbers damage and engine room bulkhead & over head damage. LEGACY COMPONENT DESC: Strut/Cross Tie
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2002
Communications › Alarms/Indicators
Issued 17 January 2002 Resolved
repair #1 and 2 bilge high water alarms LEGACY COMPONENT DESC: Bilge Alarm
Due 28 February 2002
Resolved 1 February 2002
Engineering › Sea-water System (primary cooling)
Issued 17 January 2002 Resolved
repair hole on port engine raw water suction line near flexible hose connection. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 28 February 2002
Resolved 1 February 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 17 January 2002 Resolved
replace worn bilge pump belt. LEGACY COMPONENT DESC: Bilge pump belt
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 1 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 17 January 2002 Resolved
Install guards on all exposed rotating machinery attached to main engines. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 8 February 2002
Resolved 15 July 2002
Engineering › Shafting/Propeller Arrangements
Issued 17 January 2002 Resolved
Tighten shaft packing on port shaft. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 1 February 2002
Lifesaving › Buoyant Apparatus
Issued 17 January 2002 Resolved
replace grab line for buoyant apparatus LEGACY COMPONENT DESC: Grab line
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 1 February 2002
Navigation › Piloting/Steering
Issued 17 January 2002 Resolved
Provide all nav required nav pubs. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 28 February 2002
Resolved 15 July 2002
Documentation › Safety/Response Plans/Programs
Issued 17 January 2002 Resolved
Update fire response plan to include the activation of the fixed fire fighting systems. LEGACY COMPONENT DESC: Fire Control Plans
Due 28 February 2002
Resolved 1 February 2002
Electrical › Electrical Distribution System (service)
Issued 17 January 2002 Resolved
Provide covers for batteries.
Due 28 February 2002
Resolved 1 February 2002
Communications › Radio Communications
Issued 17 January 2002 Resolved
Replace/renew hydrostatic release. LEGACY COMPONENT DESC: EPIRB
Due 28 February 2002
Resolved 1 February 2002
Communications › Alarms/Indicators
Issued 17 January 2002 Resolved
Provide bull horn for vessel intercom system. LEGACY COMPONENT DESC: General Alarm
Due 28 February 2002
Resolved 1 February 2002
Navigation › Collision/Grounding Avoidance
Issued 17 January 2002 Resolved
Rplace/renew all around white light lense. LEGACY COMPONENT DESC: Navigation Lights
Due 28 February 2002
Resolved 1 February 2002
Lifesaving › Buoyant Apparatus
Issued 17 January 2002 Resolved
Replace port side weak link. LEGACY COMPONENT DESC: Weak link
Due 28 February 2002
Resolved 1 February 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 January 2002 Resolved
Provide donning instructions for jacket type PFD's. LEGACY COMPONENT DESC: Storage
Due 8 February 2002
Resolved 15 July 2002
Lifesaving
Issued 9 January 2001 Resolved
Vessel is equipped with two varieties of type 1 PFD and is required to provide a donning placard for each.
Condition: Unknown
Due 9 January 2001
Resolved 9 January 2001
Lifesaving
Issued 9 January 2001 Resolved
Lifeline for Bouyant apparatus is deteriorated and requires replacement
Condition: Unknown
Due 9 January 2001
Resolved 9 January 2001
Construction/Loadline
Issued 20 January 1999 Resolved
Prior to 30 JAN 99, seal all BLKHD penetrations throughout vessel.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Lifesaving
Issued 20 January 1999 Resolved
Prior to the carriage of passengers, replace battery in PORT lifefloats strobe light.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Lifesaving
Issued 20 January 1999 Resolved
Prior to 30 JAN 99, replace retro-reflective tape on ring life buoy.
Condition: Unknown
Due 30 January 1999
Resolved 21 January 1999
Engineering
Issued 20 January 1999 Resolved
Prior to 30 JAN 99, label fuel oil shut off valves to engine room.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Construction/Loadline
Issued 20 January 1999 Resolved
Prior to 30 JAN 99, provide a gasket for the FWD void hatch.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Navigation
Issued 20 January 1999 Resolved
Prior to the carriage of passengers, provide up-to-date charts and publications IAW 46CFR184.420.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Construction/Loadline
Issued 20 January 1999 Resolved
Prior to 30 JAN 99, label bilge piping system.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Documentation
Issued 23 January 1998 Resolved
Provide a written waste management plan.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Lifesaving
Issued 23 January 1998 Resolved
Provide a crew training log book.
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Engineering
Issued 23 January 1998 Resolved
Properly repair or replace port tachometer._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Engineering
Issued 23 January 1998 Resolved
Properly repair or replace port tachometer.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Engineering
Issued 23 January 1998 Resolved
Replace starboard transmission gasket.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Fire Fighting
Issued 23 January 1998 Resolved
Provide a crew training log book.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Lifesaving
Issued 23 January 1998 Resolved
Post proper life jacket donning placard.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Lifesaving
Issued 13 January 1997 Resolved
Conduct man overboard drill in presence of Marine Inspector no later than 13FEB97.
Condition: Unknown
Due 13 January 1997
Resolved 13 January 1997
Engineering
Issued 13 January 1997 Resolved
Repair minor leaks on raw water outlet pipe from heat exchanger port engineduring drydock period._x001C_
Condition: Unknown
Due 13 January 1997
Resolved 13 January 1997
Construction/Loadline
Issued 13 January 1997 Resolved
Ensure joint in steering space bilge suction line is airtight and prove operation of system.
Condition: Unknown
Due 13 January 1997
Resolved 13 January 1997
Engineering
Issued 13 January 1997 Resolved
Repair and prove operation of emergency fuel oil shut off for port fuel tank.
Condition: Unknown
Due 13 January 1997
Resolved 13 January 1997
Unknown
Issued 17 January 1996 Resolved
Provide evidence of compliance with 46 CFR part 16 no later than 24JAN96.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Lifesaving
Issued 17 January 1996 Resolved
Repair with factory supplied materials, or replace both life floats with proper size/number buoyant apparatus or life float.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Lifesaving
Issued 18 January 1995 Resolved
Replace the reflective tape on all 8 close cell foam life jackets. Vessel is reduced to carrying not more than 45 total persons until cleared.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Documentation
Issued 18 January 1994 Resolved
PROVIDE PROOF OF ENROLLEMENT IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 25 February 1994
Resolved 1 March 1994
Lifesaving
Issued 18 January 1994 Resolved
PROVIDE 19 USCG APPROVED ADULT LIFE JACKETS. VESSEL IS RESTRICTED TO A TOTAL ADULT PASSENGER COUNT OF 23 UNTIL ADDITIONAL LIFE JACKETS ARE PLACED ONBOARD.
Condition: Unknown
Due 25 February 1994
Resolved 1 March 1994
Construction/Loadline
Issued 18 January 1994 Resolved
EFFECT PERMANENT REPAIRS TO BOW AREA , PORT SIDE AND SECUREALL LEAKS.
Condition: Unknown
Due 25 February 1994
Resolved 1 March 1994
Electrical
Issued 18 January 1994 Resolved
REMOVE/PROPERLY SECURE DEAD END WIRES AND WIRES WITH WIRE NUTS THROUGHOUT VESSEL.
Condition: Unknown
Due 25 February 1994
Resolved 1 March 1994
Engineering
Issued 18 January 1994 Resolved
REPAIR LEAKS ON COOLING WATER LINE ON STARBOARD ENGINE.
Condition: Unknown
Due 25 February 1994
Resolved 1 March 1994
Engineering
Issued 18 January 1994 Resolved
REPAIR LEAK ON STARBOARD EXHAUST LINE IN #4 COMPARTMENT
Condition: Unknown
Due 25 February 1994
Resolved 1 March 1994
Fire Fighting
Issued 27 October 1992 Resolved
PROVIDE 1 ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER FOR THE ENGINEROOM.
Condition: Unknown
Due 3 November 1992
Resolved 27 October 1992
Engineering
Issued 5 October 1987 Resolved
CHECK TRUENESS AND ALIGNMENT OF STARBOARD TAILSHAFT.
Condition: Unknown
Due 5 October 1987
Resolved 5 October 1987
Construction/Loadline
Issued 4 June 1987 Resolved
INSTALL KEEPER CHAINS ON ALL WEATHER DECK HATCHES AND RENEW GASKETS ON SAME.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Construction/Loadline
Issued 4 June 1987 Resolved
REMOVE "FURRING" ON ALL SIDE PLANKING AND ENDS OF UNDERDECK BEAMS IN ENGINE ROOM AND TREAT SAME WITH A PRESERVATIVE.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Accommodation/Occupational Safety
Issued 4 June 1987 Resolved
REMOVE STBD. HEAD OR INSTALL A U.S.C.G. APPROVED MARINE SANITATION DEVICE.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Construction/Loadline
Issued 4 June 1987 Resolved
RECAULK SIDE PLANKING BETWEEN FRAMES #8 AND #9 (COUNTING FROM FORWARD BHD.)ON STBD. SIDE OF ENGINE ROOM.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.