Records from 1981 to 2026. Most recent: inspection, 16 April 2026.
Inspection history · 89
16 April 2026
Administrative Inspection · Internal Structural Exam · Annual Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8315007
23 April 2025
Deficiency Check · Administrative Inspection · In-Service Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8117669
5 March 2025
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8088979
22 January 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7852812
16 November 2023
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7826116
13 September 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7791103
9 May 2023
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7685544
15 November 2022
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7594781
18 September 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7563567
17 August 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7536230
8 February 2022
Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7392895
15 October 2021
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7333412
28 April 2021
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7184575
4 January 2021
Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7119215
27 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6944573
7 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6830219
14 August 2019
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6783964
23 April 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6668297
27 November 2018
Administrative Inspection · Deficiency Check · Drydock Exam · Examination of Repairs · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6587872
24 April 2018
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6399078
21 February 2017
COI Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6089146
29 November 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6049470
24 May 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5880551
17 February 2011
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3947538
24 January 2011
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3933677
16 April 2009
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3453611
6 April 2009
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3447561
3 June 2008
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3226087
15 May 2008
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3204481
25 April 2008
Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3191386
15 February 2008
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3148212
29 March 2007
Hull Examination · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2897412
10 May 2006
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2646705
14 April 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2624730
4 May 2005
Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2348935
30 March 2005
Deficiency Check · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2322016
23 August 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2174502
16 April 2004
Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2043398
8 May 2003
Annual Inspection · Deficiency Check · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1762987
3 June 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1625540
10 April 2002
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1603067
1 May 2001
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1063684
5 April 2001
Hull Examination · Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1463653
10 March 2001
Type not recorded
No type recorded · USCGC KEY BISCAYNE (WPB 1339) · USCG Southeast District (CGD-SE) · Activity 1521544
5 June 2000
Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1369715
18 May 2000
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 820504
17 May 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 5426
12 May 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 817766
12 April 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1406693
19 May 1999
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 798575
14 May 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 189076
15 April 1999
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1469257
5 April 1999
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1469254
25 February 1999
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1510163
15 April 1998
Deficiency Check · Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1421490
22 April 1997
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1402444
10 April 1997
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1460943
28 August 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 939727
7 May 1996
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1083122
11 April 1996
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1417919
21 April 1995
Hull Examination · Plan Review "T" Boat · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1403884
20 April 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 859252
11 April 1994
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1405518
7 October 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 826367
28 September 1993
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 847507
13 April 1993
Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 643819
5 April 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1147327
31 March 1993
Deficiency Check · Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 836662
23 October 1992
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1270059
17 April 1992
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1462297
29 April 1991
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 904431
11 March 1991
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 912165
25 April 1990
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1228370
3 April 1990
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1240004
26 April 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1041736
20 April 1989
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1208089
26 April 1988
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1035752
18 March 1988
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1339411
1 May 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1325184
17 April 1987
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1004981
11 September 1986
Credit Drydock
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1308195
30 April 1986
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1296746
24 March 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 995580
15 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1287746
16 April 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974142
7 April 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1276498
9 March 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969661
27 September 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970422
13 March 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966350
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2026
Resolved
Covered metal trash containers shall be provided in lounge areas and the spaces shall be maintained to minimize fire and safety hazards. MI observed plastic trash containers throughout the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2026
Resolved 20 April 2026
Resolution: Vessel rep sent photos of metal trash cans throughout the vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 April 2026
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. MI observed emergency radio instructions that were designed for a commercial fishing vessel and did not match this specific vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2026
Resolved 20 April 2026
Resolution: Vessel rep sent picture of updated emergency radio instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. MI observed that child life jackets were separated by a piece of plywood that was not permanently secured, allowing adult and child life jackets to mix.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 April 2026
Resolved 16 April 2026
Resolution: Crew seperated life jackets with plywood and screwed it into place.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 April 2026
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. MI observed that crew was not testing the EPIRB monthly and were not logging the test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 April 2026
Resolved 16 April 2026
Resolution: Vessel tested EPIRB and started a log book.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 16 April 2026
No resolution recorded
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. 46 CFR 177.1030 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolution: Vessel to replace windows at wheel house during next dry dock.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 13 May 2025
Resolved
Vessels operated beyond the 20 nautical mile limitation specific in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter. Vessel has MF radio installation without DSC frequency transmitter, and a non-GMDSS satellite phone. Rectify to the satisfaction of the attending MI. - 47CFR80.905(a)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2025
Resolved 5 June 2025
Resolution: Captain provided FCC Bridge to Bridge raidiotelephoney certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2025
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Vessels bilge suction was inoperable in several compartments. Vessel was able to clear blockage from manifold and regain suction.
46 CFR 182.25.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 May 2025
Resolution: Check valve at manifold was sticking. Fixed prior to MI departure.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2025
Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges. Vessel mast light was inoperable. Vessel is restricted to operate during daylight and clear viability. Rectify to the satisfaction of MI.
33 CFR 83.22
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 7 May 2025
Resolution: Vessel provided documentation and photo evidence that light is now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Vessel's bow life ring buoy was missing its identification sticker.
46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 7 May 2025
Resolution: Vessel provided documentation and photo evidence showing deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. All floating waterlights were installed with the incorrect type of battery.
46 CFR 180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 7 May 2025
Resolution: Vessel provided photo evidence showing proper battery installation on waterlights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2024
Resolved
Two required fixed powered bilge pump shall be self priming and each driven by different sources of power. Vessel has only one fixed power bilge pump installed.
46 CFR 182.25-10 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 4 March 2024
Resolution: Vessel installed second fixed power bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 February 2024
Resolved
Each life float must be secured to the vessel by a painter and float free link the strength of the float free link is determined by the combined capacity of the group of life floats. The two forward life floats with the combined capacity of 24 persons had an undersized float free link rated for 11-20 persons. 46 CFR 180.20-1 (a)(5)(iii)
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
Resolution: As required by regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 February 2024
Resolved
Life preservers for children, when provided, shall be stowed separately. Vessel child size life preservers were stowed in the same location as adult size life preservers. 46 CFR 180.25-10 (c)
Action required: 705 - Other - as specified
Due 9 February 2024
Resolved 9 February 2024
Resolution: Child Life Preservers stowed as required by regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 February 2024
Resolved
Each water light must be of an approved automatic electric type constructed in accordance with 161.010. Usage of non recommended battery may cause the light to sink. Vessels water light had an expired RAY-O-VAC 945 6 volt battery installed instead of a RAY-O-VAC 942 as recommended by manufacturer. 46CFR 180.30 (b)
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
Resolution: As required by regulation.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 7 February 2024
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. The vessels port main propulsion engine was missing a guard on the front engine pulleys. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Gaurd installed as required by regulation.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 February 2024
Resolved
All escape hatches shall be marked on both sides using a least 2 inch letters "EMERGENCT EXIT,KEEP CLEAR". Vessels escape hatches were not marked as required by regulation. 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Markings as required by regulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2024
Resolved
Remote fuel shut off stations shall be marked in at least 1 inch letters indicating purpose of the valve and direction of operation. Vessels remote fuel shut off valves were not marked as required by regulation. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: 3 remote shut off valaves marked as required by regulation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 February 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space. The float switch in the space aft of the collision bulkhead was not functioning as designed. 46 CFR 182.530 (c)
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
Resolution: As required by regulation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2024
Resolved
Openings for which conductors enter shall be adequately closed. The galley electrical distribution panel had 3 unused stuffing tubes on the bottom that were not sealed. 46 CFR 183.10-20 (f)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Distribution panel sealed as required by regulation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2024
Resolved
All electrical distribution panels shall be constructed to prevent uninsulated parts that could be inadvertently touched by any person. The galley distribution panel is missing a circuit breaker blank spacer. 46 CFR 183.10-10 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Distribution panel breaker installed in opening as required by regulation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2024
Resolved
All electrical installation shall be to the satisfation of the Officer in Charge, Marine Inspection. Electrical outlet in passenger space on the starboard side above the windows is cracked and unsafe. 46 CFR 183.01-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Outlet and cover replaced as required by regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 February 2024
Resolved
All life floats shall be of approved types (160.027). The life floats installed on the vessel had only two of four permanently attached name plates as required by 46 CFR 160.010-8 as referenced by 46 CFR 160.027-2. 46 CFR 180.10-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 4 March 2024
Resolution: Vessel provided placards with neccessary information for 03 lifefloats.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 7 February 2024
Resolved
Before getting underway the master of each vessel shall ensure that their is a suitable safety orientation/ public announcement that are provided in a manner that affords all passengers the opportunity to become acquainted with stowage of life preservers, proper method of donning and adjusting the types carried on board, and the location and content of the emergency check off list required by 46 CFR 185.25-5. The vessel safety orientation was not consistent as required by regulation. 46 CFR 185.506
Action required: 705 - Other - as specified
Due 9 February 2024
Resolved 9 February 2024
Resolution: Updated Passenger Orientation as required by regulation.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 September 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol testing strips were expired, replace to the satisfaction of the attending Marine Inspector. 46 CFR 4.06-15(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 29 September 2023
Resolution: Provided objective evidence that issue was corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2023
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. New cables in engine room were not supported by metal supports and were connected to other cables with plastic tie wraps. Correct to the satisfaction of the attending Marine Inspector. 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 29 September 2023
Resolution: Provided objective evidence that issue was corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 May 2023
Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. Vessels with a keel laid date after March 28, 2022, must include plans for the monitoring device(s) within the plan submissions required in 46 CFR 177.202. The Coast Guard will work with the vessel operators to determine a reasonable implementation schedule once the plans are accepted. Vessel has not installed watchmen monitoring device. Install watchmen monitoring device to the satisfaction of the USCG Marine Inspector or remove overnight passenger endorsement from COI. Vessel is restricted from carriage of overnight passengers until rectified.
Action required: 705 - Other - as specified
Resolved 26 September 2023
Resolution: Adjsuted COI for removal of overnight passengers.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have an installed interconnected fire detection system. Install interconnected fire detection system to the satisfaction of the USCG Marine inspector or reduced vessel's route to limited coastwise. Vessel is restricted to limited coastwise until rectified.
46 CFR 181.405 (c)
Action required: 705 - Other - as specified
Resolved 26 September 2023
Resolution: tested and verified interconnected fire detection system.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 24 April 2018
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load under such requirements without exceeding its design limitations. Starboard engine is not responding to throttle manipulation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 26 April 2018
Resolution: Replaced with new cable. Conducted underway power checks with no discrepancies noted.
Engineering › Bilge Water Management System › Not Operational
Issued 24 April 2018
Resolved
All vessels of 26' and over shall be fitted with individual bilge lines and bilge suction for each watertight compartment. Collision Bulkhead did not drain the space of water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 26 April 2018
Resolution: Positive shut-off valve seized internally. Replaced with a new positive shut-off valve.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 April 2018
Resolved
Portable fire extinguisher must be installed to the satisfaction of the OCMI, Marine Inspector. Operating station portable fire extinguisher mounting bracket broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 26 April 2018
Resolution: Vessel Master replaced mounting bracket.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 April 2018
Resolved
Remote fuel shutoff stations shall be marked indicating purpose and direction of operation. All three remote fuel shutoff stations do not have markings indicating direction of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 26 April 2018
Resolution: Vessel Master properly marked direction of operation.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 24 April 2018
Resolved
Portable watertight containers for distress flares and smoke signals shall be of bright color and marked “DISTRESS SIGNALS”. Container is dull and no markings are legible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 26 April 2018
Resolution: Vessel Master provided a new bright orange container with proper labeling visible.
Construction/Loadline › Hull › Bracket
Issued 24 January 2011
Resolved
Replace AC bracket in 2nd compartment.
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 17 February 2011
Resolution: The bracket was replaced under the AC unit.
Construction/Loadline › Hull › Girder
Issued 24 January 2011
Resolved
Reweld girder in engine room.
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 17 February 2011
Resolution: Girders have been rewelded in engine room.
Construction/Loadline › Hull › Side Shell
Issued 24 January 2011
Resolved
Repair holes through out house as marked.
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 17 February 2011
Resolution: Repairs were made to the house.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 April 2009
Resolved
Remove sections of PVC from main engine jacket water system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 June 2009
Resolved 16 July 2010
Resolution: Item corrected.
Fire Fighting › Fire Main › Condition
Issued 23 April 2009
Resolved
Make fire main piping available for system pressure test at annual exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2009
Resolved 16 July 2010
Resolution: Item corrected
Construction/Loadline › Hull › Bottom Plating
Issued 6 April 2009
Resolved
Vessel's hull exam due date has lapsed. Vessel is prohibited from carrying passengers until completion of a credit drydock and hull exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2009
Resolution: Vessel completed credit hull exam.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 15 May 2008
Resolved
Vessel to provide overspeed protection and Tach/RPM gauge to ship's generator.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 30 May 2008
Resolution: Overspeed protection not required on a T-boat. Item cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2006
Resolved
Prove proper operation of starboard running light prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2006
Resolution: Resolved satisfactorily.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2006
Resolved
Attach loose wires in crew's cabin void with metallic wire ties.
Action required: 705 - Other - as specified
Due 18 May 2006
Resolved 10 May 2006
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 April 2006
Resolved
Properly label inside cover of engineroom electrical panel. (Numbers for breakers don't match.)
Action required: 705 - Other - as specified
Due 18 May 2006
Resolved 10 May 2006
Engineering › Fuel Oil Service System › Filter
Issued 14 April 2006
Resolved
Four engine fuel filters are not labeled as marine rated. Call Racor with model and type numbers and confirm that they are marine rated. Replace as necessary.
Action required: 705 - Other - as specified
Due 18 May 2006
Resolved 19 April 2006
Resolution: Resolved satisfactorily.
Engineering › Lubricating Oil Service System › Gauge
Issued 14 April 2006
Resolved
Prove proper operation of the following gauges: engine RPM, jacketwater discharge temperature, lube oil pressure, and ammeter for generator. Remove all inoperable gauges.
Action required: 705 - Other - as specified
Due 18 May 2006
Resolved 19 April 2006
Resolution: Resolved satisfactorily.
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 April 2006
Resolved
Install brackets for hydraulic hose.
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 10 May 2006
Engineering › Fuel Oil Service System › Valve
Issued 4 May 2005
Resolved
Replace broken valve handle in e/r.
Due 4 June 2005
Resolved 2 June 2005
Fire Fighting › Fire Pumps › Pressure
Issued 4 May 2005
Resolved
Replace inoperable fire pump gauge.
Due 4 June 2005
Resolved 2 June 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 May 2005
Resolved
Permanently mount stern light aft of refrigerant line. (Currently loose and blocked by line.)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2005
Construction/Loadline › Penetrations › Gasket
Issued 30 March 2005
Resolved
Seal all bulkhead penetrations.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 30 March 2005
Resolved
Install metallic supports for cables and wires throughout vessel.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Fuse
Issued 30 March 2005
Resolved
Cover exposed fuse on starboard side of engine room.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 4 May 2005
Construction/Loadline › Structures › Manhole
Issued 30 March 2005
Resolved
Repair hole in forepeak scuttle.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 4 May 2005
Electrical › Electric Generation Source (service)
Issued 16 April 2004
Resolved
Plug/cover hole on battery charger/converter under wheelhouse console.
Due 16 May 2004
Resolved 27 April 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 April 2004
Resolved
Make doors for distribution panels (J box) secure and cover all holes.
Due 16 May 2004
Resolved 27 April 2004
Lifesaving › Buoyant Apparatus
Issued 16 April 2004
Resolved
Replace deteriorated line for lifefloat lights (2) with approved line.
Due 16 May 2004
Resolved 27 April 2004
Lifesaving › Buoyant Apparatus
Issued 16 April 2004
Resolved
Mark all oars for lifefloats with vsl name.
Due 16 May 2004
Resolved 27 April 2004
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 April 2004
Resolved
Gouge and weld cracked welds for exhaust dome.
Due 16 May 2004
Resolved 27 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 16 April 2004
Resolved
Mark all emergency exits with (both sides) "Emergency Exit, Keep Clear".
Due 16 May 2004
Resolved 27 April 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 April 2004
Resolved
Labe J box for A/C in passenger berthing.
Due 16 May 2004
Resolved 27 April 2004
Construction/Loadline › Hull › Side Shell
Issued 16 April 2004
Resolved
Crop and insert (minimum) 18"x18" on stbd sideshell in bow compartment where breached. Crop and insert to good metal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2004
Personnel › Training
Issued 8 May 2003
Resolved
Provide documentation of 1st aid/cpr cards for 50% of crew. LEGACY COMPONENT DESC: Firemen/Watertender
Due 8 June 2003
Resolved 7 July 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 May 2003
Resolved
Update first aid kit to reflect inventory list (Ace Bandage).
Due 8 June 2003
Resolved 7 July 2003
Lifesaving › Lifebuoys
Issued 8 May 2003
Resolved
Renew port life ring
Due 8 June 2003
Resolved 7 July 2003
Pollution Prevention/Response › Prevention Equipment
Issued 8 May 2003
Resolved
Make Sewage tank water tight (a/c drain into tank has open area) LEGACY COMPONENT DESC: Sewage System Tank
Due 8 June 2003
Resolved 16 April 2004
Communications › Alarms/Indicators
Issued 8 May 2003
Resolved
Renew light for E/R bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Due 8 June 2003
Resolved 7 July 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 8 May 2003
Resolved
Install fire ext in Galley Area. LEGACY COMPONENT DESC: Location
Due 8 June 2003
Resolved 7 July 2003
Engineering › Sea-water System (primary cooling)
Issued 8 May 2003
Resolved
Install pipe hanger on stbd sea water intake for main diesel engine. LEGACY COMPONENT DESC: Piping
Due 8 June 2003
Resolved 7 July 2003
Construction/Loadline › Hull
Issued 8 May 2003
Resolved
USCG will address handrail required by 46 CFR 177.35-1.
Due 8 June 2003
Resolved 16 April 2004
Construction/Loadline › Hull › Bottom Plating
Issued 31 March 2003
Resolved
Port Side - crop out and renew 6.5' x 13' section of waterd hull plate overlap plate to match existing lap joints. Extend plate 6" to match existing lap joints. extend plate 6" aft of sleeping quaters at bulkheads
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2003
Construction/Loadline › Hull › Bottom Plating
Issued 31 March 2003
Resolved
Stbd Side - Crop out and renew 4' x 10' section of wasted hull plate - same requirements.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2003
Construction/Loadline › Hull
Issued 31 March 2003
Resolved
Provide hull gaugin report with wiagram of readings below .20"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2003
Construction/Loadline › Structures
Issued 31 March 2003
Resolved
Make fwd engine room bulkhead water tight, 1 small hole weld and a/c drain. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 3 May 2003
Resolved 8 May 2003
Construction/Loadline › Structures
Issued 31 March 2003
Resolved
Replace 2 bracket and 4 side longitudinals port side under hatch in #1 compartment
Due 2 May 2003
Resolved 8 May 2003
Communications › Alarms/Indicators
Issued 31 March 2003
Resolved
Mount bilge alarm in #2 Compartment LEGACY COMPONENT DESC: Bilge Alarm
Due 2 May 2003
Resolved 8 May 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 31 March 2003
Resolved
Remove PVC Pipe from engine sea suction. Replace with solid metal piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2003
Engineering › Freshwater System (jacketwater cooling)
Issued 31 March 2003
Resolved
Permanently cap, weld or seal old, unused thru-hull vlaves in engine room. LEGACY COMPONENT DESC: Piping
Due 2 May 2003
Resolved 8 May 2003
Engineering › Sea-water System (primary cooling)
Issued 31 March 2003
Resolved
Permanently cap, weld or seal all unused thru-hull valves in engienr room.
Due 2 May 2003
Resolved 18 April 2003
Engineering
Issued 31 March 2003
Resolved
Remove PVC pipe from sewage & a/c suction, replace with solid metal piping.
Due 2 May 2003
Resolved 8 May 2003
Resolution: Discharge pipe is still PVC, but suction is metal piping.
Electrical › Lighting (emergency)
Issued 31 March 2003
Resolved
Install new emergency light in cabin. LEGACY COMPONENT DESC: Lighting Fixture
Due 8 June 2003
Resolved 7 July 2003
Navigation › Piloting/Steering
Issued 31 March 2003
Resolved
Renew publications IAW 46 CFR 184.420
Due 8 June 2003
Resolved 7 July 2003
Construction/Loadline › Structures
Issued 10 April 2002
Resolved
Install lanyards on all deck hatches. LEGACY COMPONENT DESC: Manhole
Due 10 May 2002
Resolved 10 April 2002
Operations/Management › Lifesaving
Issued 10 April 2002
Resolved
Replace out of date Hydrostatic release for EPIRB. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2002
Engineering › Bilge Water Management System
Issued 10 April 2002
Resolved
Attach bilge alarm in #2 compartment.
Due 11 April 2002
Resolved 11 April 2002
Resolution: Installed new.
Electrical › Electrical Distribution System (service)
Issued 10 April 2002
Resolved
Remove dead end wires and replace wire nuts IAW 46CFR183.340i. LEGACY COMPONENT DESC: Wiring
Due 11 April 2002
Resolved 11 April 2002
Resolution: 4 wire nuts removed, 5 dead end wires removed. New Radio installation verified.
Fire Fighting › Fire Hoses
Issued 10 April 2002
Resolved
Replace leaky hose. (2) LEGACY COMPONENT DESC: Condition
Due 10 May 2002
Resolved 16 April 2004
Deck/Cargo › Mooring/Anchoring
Issued 10 April 2002
Resolved
Stop hydraulic fluid leak from windlass. LEGACY COMPONENT DESC: Winch
Due 14 April 2002
Resolved 10 April 2002
Construction/Loadline
Issued 5 April 2001
Resolved
Ensure bilge pumps dual clamped.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Accommodation/Occupational Safety
Issued 5 April 2001
Resolved
Repair sewage line - tighten and remove duct tape.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Engineering
Issued 5 April 2001
Resolved
Provide cap for water separator located aft bulkhead of engine room.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Accommodation/Occupational Safety
Issued 5 April 2001
Resolved
Repair or replace gaskets on the following main cabin windows: 3rd window back from the bow, 3rd window up from the stern starboard side and 2nd window up from the stern port side.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 5 April 2001
Resolved
Repair ring buoy light (port side) and retro on ring buoy (starboard side).
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Engineering
Issued 5 April 2001
Resolved
Provide machinery guards for diesel engines.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 5 April 2001
Resolved
Properly support starboard engine bilge pump piping.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Engineering
Issued 5 April 2001
Resolved
Provide inspection cap for port MDE starter.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Engineering
Issued 5 April 2001
Resolved
Provide plug for ball valve located on stbd bulkhead.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 5 April 2001
Resolved
Repaint name on stern.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Electrical
Issued 5 April 2001
Resolved
Secure overhead electrical wiring every 24".
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Accommodation/Occupational Safety
Issued 5 April 2001
Resolved
Provide metal trash can for galley area.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Electrical
Issued 5 April 2001
Resolved
Provide electrical knock out cover for galley panel.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Accommodation/Occupational Safety
Issued 5 April 2001
Resolved
Permanently install pipe support brackets for A/C piping.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Engineering
Issued 5 April 2001
Resolved
Repair leaks on supply and return hydraulic piping.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Accommodation/Occupational Safety
Issued 5 April 2001
Resolved
Label A/C controller.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 5 April 2001
Resolved
Provide junction boses for freezer wiring.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 5 April 2001
Resolved
Renew gasket for water tight hatches.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 5 April 2001
Resolved
Ensure emergency lighting in engine room operates.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 5 April 2001
Resolved
Remove breaker from electrical panel due to short.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 5 April 2001
Resolved
Re-install bilge high level alarm, lable bilge valve manifold and clean bilges
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Engineering
Issued 5 April 2001
Resolved
Clean battery post connections.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Engineering
Issued 5 April 2001
Resolved
Install missing bolts in auxilary water pump housing.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Engineering
Issued 5 April 2001
Resolved
Clean engines - excessive oil.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 5 April 2001
Resolved
Remove copper tubing in lazarette.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 5 April 2001
Resolved
Clean oil bath cleaners for generators.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 5 April 2001
Resolved
Install lights and covers in engine room.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 5 April 2001
Resolved
Label electric panel.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 5 April 2001
Resolved
Make access plates for inspection (wooden deck) in area of port storage compartment.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 5 April 2001
Resolved
Remove wire nuts in A/C and bilge level indicator.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Documentation
Issued 5 April 2001
Resolved
Provide FCC equipment safety certificate.
Condition: Unknown
Due 25 April 2001
Resolved 23 April 2001
Electrical
Issued 5 April 2001
Resolved
Permanently mark electric panel.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Engineering
Issued 5 April 2001
Resolved
Remove kinks from raw water pump discharge hose on aux. pumps.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 5 April 2001
Resolved
Install gasket on forepeak hatch.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 5 April 2001
Resolved
Repair hatch cover locking bars - 2 forward and lazarette.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 5 April 2001
Resolved
Add retro to port life ring.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 5 April 2001
Resolved
Replace expired EPIRB battery.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 5 June 2000
Resolved
REMOVE HULL PLATING AND PREPARE FOR INSPECTION AN AREA APPROX. 2'x2' IN WAYOF THE PORT SHAFT STUFFING BOX. PLATE IS NOT TO BE REPLACE UNTIL APPROVAL BY AN ATTENDING [name withheld].
Condition: Unknown
Due 9 June 2000
Resolved 6 June 2000
Accommodation/Occupational Safety
Issued 18 May 2000
Resolved
REMOVE & REPLACE BROKEN WINDOWS ALONG CABIN & BRIDGE.
Condition: Unknown
Due 19 May 2000
Resolved 23 May 2000
Electrical
Issued 18 May 2000
Resolved
PROVE PROPER OPERATION OF ALL BRIDGE ELECTRONICS PRIOR TO GETTING UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 19 May 2000
Resolved 23 May 2000
Engineering
Issued 12 April 2000
Resolved
REPLACE FUEL FILTER FIRE BOWL (1) ON PORT ENGINE.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Electrical
Issued 12 April 2000
Resolved
CAP/PLUG HOLE IN TOP OF ENGINE ROOM FORWARD BREAKER PANEL.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Accommodation/Occupational Safety
Issued 12 April 2000
Resolved
PLUG OUT OF SERVICE AC DRAIN LINE TO SEWAGE TANK.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Electrical
Issued 12 April 2000
Resolved
REPLACE BOLTS IN ENGINE ROOM EXHAUST FAN MOUNTING BRACKET.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Electrical
Issued 12 April 2000
Resolved
SECURE ENGINE ROOM EXHAUST FAN WIRE TO/FROM SWITCH.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Electrical
Issued 12 April 2000
Resolved
REPLACE BATTERIES IN ENGINE ROOM EMERGENCY LIGHTING.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Electrical
Issued 12 April 2000
Resolved
HARD WIRE CREW COMPARTMENT BAIT FREEZERS.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Documentation
Issued 12 April 2000
Resolved
PROVIDE VALID SAFETY RADIO TELEPHONE CERTIFICATE.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Accommodation/Occupational Safety
Issued 12 April 2000
Resolved
CLEAN AREA AROUND DEEP FAT FRYERS AND ENGINE ROOM EXHAUST FAN TO PREVENT FIRE HAZARD.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Lifesaving
Issued 15 April 1999
Resolved
CONDUCT FIRE, MAN OVERBOARD AND ABANDON DRILLS IN THE PRESENCE OF US COAST GUARD MARINE INSPECTORS.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Construction/Loadline
Issued 15 April 1998
Resolved
MAKE WATERTIGHT 2 INCH HOLE BETWEEN E/R AND CREW'S WAURTERS AND 2 (TWO) 3/4INCH HOLES BETWEEN FUEL SPACE AND PASSENGER ACCOM. (THESE HOLES WERE CREATED BY REMOVAL OF WIRES/PIPES AND FITTINGS).
Condition: Unknown
Due 29 April 1998
Resolved 20 April 1998
Navigation
Issued 15 April 1998
Resolved
PROVIDE CURRENT COPY OF TIDE AND CURRENT TABLE IN ACCORDANCE W/ 46 CFR 184.420
Condition: Unknown
Due 29 April 1998
Resolved 20 April 1998
Construction/Loadline
Issued 15 April 1998
Resolved
WELD UNDERSIDE OF INSET PLATE AND BEAMS IN WAY OF E/R OVERHEAD.
Condition: Unknown
Due 29 April 1998
Resolved 20 April 1998
Construction/Loadline
Issued 15 April 1998
Resolved
MAKE W/T THE FOLLOWING THRU-HULL FITTINGS: A)WIRE BETWEEN LAZERETTE & E/R B) VARIOUS WIRES BTWN E/R & CREW'S ACCOM. C) WIRES & FRESH WATER PIPE FITTINGS BTWN FUEL VOID & PASSENGER ACCOM. D) VARIOUS WIRES BTWN CREWS ACCOM & FUEL VOID. THRU-HULL FITTINGS IMPROPER
Condition: Unknown
Due 29 April 1998
Resolved 20 April 1998
Lifesaving
Issued 10 April 1997
Resolved
VESSEL'S LIFE FLOATS NEED NEW RETROREFLECTIVE TAPE AND SEVERAL HOLES NEED TO BE PATCHED, 46 CFR 180.200.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Electrical
Issued 10 April 1997
Resolved
VESSEL HAD SEVERAL WIRE SPLICES UTI.IZING WIRE NUTS, 46 CFR 183.340.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Documentation
Issued 10 April 1997
Resolved
VESSEL MISSING STATION BILL FOR CREW, 46 CFR 185.514.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Documentation
Issued 10 April 1997
Resolved
VESSEL MISSING PFD DONNING INSTRUCTIONS PLACARD, 46 CFR 185.516.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Documentation
Issued 10 April 1997
Resolved
VESSEL DID NOT HAVE NAVIGATIONAL PUBLICATIONS REQUIRED BY 46 CFR 184.420.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Lifesaving
Issued 10 April 1997
Resolved
VESSEL REQUIRED TO HAVE ENOUGH LIFEFLOATS FOR 100% WHICH IS 50 PERSONS. ONLY HAD CAPACITY FOR 49 PERSONS. REQUIRED OPERATOR TO ADD A LIFE RING TO LIFE FLOATS TO MEET 100%, 46 CFR 180.200
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Accommodation/Occupational Safety
Issued 10 April 1997
Resolved
MAKE PERMANENT ALTERATIONS TO MARINE SANITATION DEVICE BY INSTALLING A LEVEL INDICATOR THAT INDICATES WHEN THE MARINE SANITATION DEVICE IS MORETHAN 3/4 FULL BY VOLUME TO SATISFACTION OF USCG MARINE INSPECTOR, REQUIRED BY 33 CFR 159.83.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 10 April 1997
Resolved
PASSENGER AREA EMERGENCY EXIT NOT MARKED PROPERLY, 46 CFR 185.606.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 10 April 1997
Resolved
WATERTIGHT HATCHES NOT MARKED PROPERLY, 46 CFR 185.610.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Navigation
Issued 10 April 1997
Resolved
VESSEL MISSING RADIO EMERGENCY BROADCAST PLACARD, 46 CFR 184.510.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 10 April 1997
Resolved
VESSEL PYROTECHNIC STORAGE CONTAINER WAS NOT MARKED WITH VESSEL'S NAME, 46 CFR 185.614.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Lifesaving
Issued 10 April 1997
Resolved
ONE OF THE LIFEFLOATS ON VESSEL WAS STENCILED 13 PASSENGERS, LABEL SPECIFIED 12 PASSENGERS, 46 CFR 185.604.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Documentation
Issued 10 April 1997
Resolved
VESSEL DID NOT HAVE A LOG OF DRILLS CONDUCTED AND TESTS DONE ON NAVIGATIONAL EQIUPMENT, STEERING, PROPULSION, EPIRB; 46 CFR 185.520, 185.320, AND 185.728.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Electrical
Issued 11 April 1996
Resolved
Install four lighting fixtures in engineroom, two over each main engine as per 176.25-50.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 11 April 1996
Resolved
Post emergency checkoff list as per 185.25-1.
Condition: Unknown
Due 11 April 1996
Resolved 15 April 1996
Engineering
Issued 11 April 1996
Resolved
Remove all unused wooden structures and other combustibles from ships engineroom as per 176.25-50.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Engineering
Issued 11 April 1996
Resolved
Replace both fuel tank flame screens with 30/30 mesh as per 182.20-35 (d).
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Electrical
Issued 11 April 1996
Resolved
Install both battery box covers on the battery boxes so the vessels movement will not cause the covers to come off the boxes as per 183.05-20.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 11 April 1996
Resolved
Repair and/or replace EPIRB and properly install as per 180.40 (3) and do not move vessel from pier until repairs are complete.
Condition: Unknown
Due 11 April 1996
Resolved 15 April 1996
Construction/Loadline
Issued 11 April 1996
Resolved
Place a pipe plug in the female end of the unused sea valve in the vessels engineroom as per 176.25-50.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Construction/Loadline
Issued 11 April 1996
Resolved
Prove proper operation of the Fire pump/Bilge pump crossover system in the presence of a CG inspector as per 181.10-1 and 182.25-5 (b).
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Navigation
Issued 11 April 1994
Resolved
Replace with proper type running lights show the proper arch of visibility.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Electrical
Issued 11 April 1994
Resolved
Renew old and improper wiring around the vessel.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Accommodation/Occupational Safety
Issued 11 April 1994
Resolved
Replace glass port side berthing area port hole.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Construction/Loadline
Issued 28 September 1993
Resolved
PROVIDE COVERS FOR PORT HOLES ON STARBOARD FORWARD CABIN.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Electrical
Issued 28 September 1993
Resolved
PROPERLY MOUNT AND RUN GENERATOR STARTING WIRE. _x001C_ _x001C_
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Unknown
Issued 28 September 1993
Resolved
REPAIR BOTTOM TWO STEPS LEADING INTO FORWARD CABIN.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Unknown
Issued 28 September 1993
Resolved
CLEAN EXCESSIVE OILY RESIDUE FROM ENGINE ROOM EXHUAST FAN.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Fire Fighting
Issued 28 September 1993
Resolved
HARD PIPE ALL OF THE FIRE MAIN LINE.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Unknown
Issued 28 September 1993
Resolved
PROVIDE MACHINERY GUARD FOR AFT PART OF GENERATOR.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Engineering
Issued 31 March 1993
Resolved
RENEW FUEL HOSE ON STARBOARD ENGINE.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Engineering
Issued 31 March 1993
Resolved
RENEW FUEL HOSE FROM AFT FUEL FUEL TANK AND IS ATTACHED TO RACOR FILTERS.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Fire Fighting
Issued 31 March 1993
Resolved
ALL CONNECTIONS TO AND FROM THE VESSEL'S FIRE PUMP IS TO BE HARD PIPED.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Fire Fighting
Issued 17 April 1992
Resolved
Remount portable fire extinguisher in galley to an area for easier access.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Accommodation/Occupational Safety
Issued 17 April 1992
Resolved
Reroute 110 volt cable for the cooking appliances, to protect cable from damage.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Electrical
Issued 17 April 1992
Resolved
Clean battery terminals and cap all battery cells.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Documentation
Issued 20 April 1989
Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Construction/Loadline
Issued 20 April 1989
Resolved
RENEW GASKET TO EMERGENCY ESCAPE HATCH TO ENGINE ROOM AFT.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 20 April 1989
Resolved
REPLACE LANYARDS LEADING FROM 4 LIFEFLOATS TO THEIR ASSOCIATED WATERLIGHTS.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Navigation
Issued 20 April 1989
Resolved
DEMONSTRATE PROPER OPERATION OF HYDRAULIC STEERING (SUCH THAT THE RAMS CAN BE OBSERVED STOP-TO-STOP).
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Electrical
Issued 17 April 1987
Resolved
PROVIDE PROPER BATTERY BOX FOR FISHING REEL BATTERIES IN ENGINE ROOM.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Lifesaving
Issued 17 April 1987
Resolved
REPAIR FORWARD ESCAPE HATCH SO YOU CAN OPERATE IT FROM THE INSIDE.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Lifesaving
Issued 17 April 1987
Resolved
PROVIDE 6 SMOKES AND 6 FLARES WITH CURRENT DATES.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Fire Fighting
Issued 17 April 1987
Resolved
PROVIDE 5GPM HAND FIRE PUMP WITH HOSES
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Accommodation/Occupational Safety
Issued 17 April 1987
Resolved
PROVIDE SCREEN IN VENT OVER GALLEY GRILL
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Construction/Loadline
Issued 17 April 1987
Resolved
REPLACE MISSING BOLTS IN MANHOLE TO FUEL TANK SPACE
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987