DOLPHIN

DOLPHIN is a 1963 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in April 2026, along with 32 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2022.

Records from 2016 to 2026. Most recent: inspection, 16 April 2026.

Built
1963
Last inspected
16 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF4615
Flag
UNITED STATES
Maury page id
psix-44599

Documentation record

Registered dimensions (L × B × D)78.3 ft × 20.0 ft × 7.0 ft
Registered tonnagegross 73 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRISTENSEN BOAT WORKS · SOUTH HOUSTON, TX, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPORT ARANSAS, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Simplified, Gross Ton
58 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FLIPPER Passenger (Inspected) · MISLE 231148 · 18 September 2022 · activity 7563567

Inspection history · 23

16 April 2026 Administrative Inspection · Internal Structural Exam · Annual Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8315007
23 April 2025 Deficiency Check · Administrative Inspection · In-Service Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8117669
5 March 2025 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8088979
22 January 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7852812
16 November 2023 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7826116
13 September 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7791103
9 May 2023 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7685544
15 November 2022 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7594781
18 September 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7563567
17 August 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7536230
8 February 2022 Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7392895
15 October 2021 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7333412
28 April 2021 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7184575
4 January 2021 Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7119215
27 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6944573
7 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6830219
14 August 2019 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6783964
23 April 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6668297
27 November 2018 Administrative Inspection · Deficiency Check · Drydock Exam · Examination of Repairs · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6587872
24 April 2018 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6399078
21 February 2017 COI Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6089146
29 November 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6049470
24 May 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5880551

Deficiency record · 32

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2026 Resolved
Covered metal trash containers shall be provided in lounge areas and the spaces shall be maintained to minimize fire and safety hazards. MI observed plastic trash containers throughout the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2026
Resolved 20 April 2026
Resolution: Vessel rep sent photos of metal trash cans throughout the vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 April 2026 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. MI observed emergency radio instructions that were designed for a commercial fishing vessel and did not match this specific vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2026
Resolved 20 April 2026
Resolution: Vessel rep sent picture of updated emergency radio instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2026 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. MI observed that child life jackets were separated by a piece of plywood that was not permanently secured, allowing adult and child life jackets to mix.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 April 2026
Resolved 16 April 2026
Resolution: Crew seperated life jackets with plywood and screwed it into place.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 April 2026 Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. MI observed that crew was not testing the EPIRB monthly and were not logging the test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 April 2026
Resolved 16 April 2026
Resolution: Vessel tested EPIRB and started a log book.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 16 April 2026 No resolution recorded
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. 46 CFR 177.1030 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolution: Vessel to replace windows at wheel house during next dry dock.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 13 May 2025 Resolved
Vessels operated beyond the 20 nautical mile limitation specific in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter. Vessel has MF radio installation without DSC frequency transmitter, and a non-GMDSS satellite phone. Rectify to the satisfaction of the attending MI. - 47CFR80.905(a)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2025
Resolved 5 June 2025
Resolution: Captain provided FCC Bridge to Bridge raidiotelephoney certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2025 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Vessels bilge suction was inoperable in several compartments. Vessel was able to clear blockage from manifold and regain suction. 46 CFR 182.25.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 May 2025
Resolution: Check valve at manifold was sticking. Fixed prior to MI departure.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2025 Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges. Vessel mast light was inoperable. Vessel is restricted to operate during daylight and clear viability. Rectify to the satisfaction of MI. 33 CFR 83.22
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 7 May 2025
Resolution: Vessel provided documentation and photo evidence that light is now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025 Resolved
Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Vessel's bow life ring buoy was missing its identification sticker. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 7 May 2025
Resolution: Vessel provided documentation and photo evidence showing deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. All floating waterlights were installed with the incorrect type of battery. 46 CFR 180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 7 May 2025
Resolution: Vessel provided photo evidence showing proper battery installation on waterlights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2024 Resolved
Two required fixed powered bilge pump shall be self priming and each driven by different sources of power. Vessel has only one fixed power bilge pump installed. 46 CFR 182.25-10 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 4 March 2024
Resolution: Vessel installed second fixed power bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 February 2024 Resolved
Each life float must be secured to the vessel by a painter and float free link the strength of the float free link is determined by the combined capacity of the group of life floats. The two forward life floats with the combined capacity of 24 persons had an undersized float free link rated for 11-20 persons. 46 CFR 180.20-1 (a)(5)(iii)
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
Resolution: As required by regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 February 2024 Resolved
Life preservers for children, when provided, shall be stowed separately. Vessel child size life preservers were stowed in the same location as adult size life preservers. 46 CFR 180.25-10 (c)
Action required: 705 - Other - as specified
Due 9 February 2024
Resolved 9 February 2024
Resolution: Child Life Preservers stowed as required by regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 February 2024 Resolved
Each water light must be of an approved automatic electric type constructed in accordance with 161.010. Usage of non recommended battery may cause the light to sink. Vessels water light had an expired RAY-O-VAC 945 6 volt battery installed instead of a RAY-O-VAC 942 as recommended by manufacturer. 46CFR 180.30 (b)
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
Resolution: As required by regulation.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 7 February 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. The vessels port main propulsion engine was missing a guard on the front engine pulleys. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Gaurd installed as required by regulation.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 February 2024 Resolved
All escape hatches shall be marked on both sides using a least 2 inch letters "EMERGENCT EXIT,KEEP CLEAR". Vessels escape hatches were not marked as required by regulation. 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Markings as required by regulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2024 Resolved
Remote fuel shut off stations shall be marked in at least 1 inch letters indicating purpose of the valve and direction of operation. Vessels remote fuel shut off valves were not marked as required by regulation. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: 3 remote shut off valaves marked as required by regulation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 February 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space. The float switch in the space aft of the collision bulkhead was not functioning as designed. 46 CFR 182.530 (c)
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
Resolution: As required by regulation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2024 Resolved
Openings for which conductors enter shall be adequately closed. The galley electrical distribution panel had 3 unused stuffing tubes on the bottom that were not sealed. 46 CFR 183.10-20 (f)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Distribution panel sealed as required by regulation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2024 Resolved
All electrical distribution panels shall be constructed to prevent uninsulated parts that could be inadvertently touched by any person. The galley distribution panel is missing a circuit breaker blank spacer. 46 CFR 183.10-10 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Distribution panel breaker installed in opening as required by regulation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2024 Resolved
All electrical installation shall be to the satisfation of the Officer in Charge, Marine Inspection. Electrical outlet in passenger space on the starboard side above the windows is cracked and unsafe. 46 CFR 183.01-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Outlet and cover replaced as required by regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 February 2024 Resolved
All life floats shall be of approved types (160.027). The life floats installed on the vessel had only two of four permanently attached name plates as required by 46 CFR 160.010-8 as referenced by 46 CFR 160.027-2. 46 CFR 180.10-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 4 March 2024
Resolution: Vessel provided placards with neccessary information for 03 lifefloats.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 7 February 2024 Resolved
Before getting underway the master of each vessel shall ensure that their is a suitable safety orientation/ public announcement that are provided in a manner that affords all passengers the opportunity to become acquainted with stowage of life preservers, proper method of donning and adjusting the types carried on board, and the location and content of the emergency check off list required by 46 CFR 185.25-5. The vessel safety orientation was not consistent as required by regulation. 46 CFR 185.506
Action required: 705 - Other - as specified
Due 9 February 2024
Resolved 9 February 2024
Resolution: Updated Passenger Orientation as required by regulation.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 September 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol testing strips were expired, replace to the satisfaction of the attending Marine Inspector. 46 CFR 4.06-15(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 29 September 2023
Resolution: Provided objective evidence that issue was corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2023 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. New cables in engine room were not supported by metal supports and were connected to other cables with plastic tie wraps. Correct to the satisfaction of the attending Marine Inspector. 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 29 September 2023
Resolution: Provided objective evidence that issue was corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 May 2023 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. Vessels with a keel laid date after March 28, 2022, must include plans for the monitoring device(s) within the plan submissions required in 46 CFR 177.202. The Coast Guard will work with the vessel operators to determine a reasonable implementation schedule once the plans are accepted. Vessel has not installed watchmen monitoring device. Install watchmen monitoring device to the satisfaction of the USCG Marine Inspector or remove overnight passenger endorsement from COI. Vessel is restricted from carriage of overnight passengers until rectified.
Action required: 705 - Other - as specified
Resolved 26 September 2023
Resolution: Adjsuted COI for removal of overnight passengers.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have an installed interconnected fire detection system. Install interconnected fire detection system to the satisfaction of the USCG Marine inspector or reduced vessel's route to limited coastwise. Vessel is restricted to limited coastwise until rectified. 46 CFR 181.405 (c)
Action required: 705 - Other - as specified
Resolved 26 September 2023
Resolution: tested and verified interconnected fire detection system.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 24 April 2018 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load under such requirements without exceeding its design limitations. Starboard engine is not responding to throttle manipulation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 26 April 2018
Resolution: Replaced with new cable. Conducted underway power checks with no discrepancies noted.
Engineering › Bilge Water Management System › Not Operational
Issued 24 April 2018 Resolved
All vessels of 26' and over shall be fitted with individual bilge lines and bilge suction for each watertight compartment. Collision Bulkhead did not drain the space of water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 26 April 2018
Resolution: Positive shut-off valve seized internally. Replaced with a new positive shut-off valve.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 April 2018 Resolved
Portable fire extinguisher must be installed to the satisfaction of the OCMI, Marine Inspector. Operating station portable fire extinguisher mounting bracket broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 26 April 2018
Resolution: Vessel Master replaced mounting bracket.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 April 2018 Resolved
Remote fuel shutoff stations shall be marked indicating purpose and direction of operation. All three remote fuel shutoff stations do not have markings indicating direction of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 26 April 2018
Resolution: Vessel Master properly marked direction of operation.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 24 April 2018 Resolved
Portable watertight containers for distress flares and smoke signals shall be of bright color and marked “DISTRESS SIGNALS”. Container is dull and no markings are legible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 26 April 2018
Resolution: Vessel Master provided a new bright orange container with proper labeling visible.

Casualty record · 1

18 September 2022Routine · role: Involved in a Marine Casualty · activity 7563567
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.