Records from 2016 to 2026. Most recent: inspection, 13 May 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2026
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Route is limited to not more than 20 miles from shore until lights are placed on lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2026
Resolved 16 May 2026
Resolution: Lights added to PFDs
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 May 2026
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Liferaft not installed, awaiting install after annual servicing. Vessel authorized to temporarily operate in/about Lake St. Claire where average depth renders lack of survival acceptable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2026
Resolved 20 May 2026
Resolution: Liferaft serviced and placed in service.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2026
Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible. Paper charts found not updated. Update any charts relied on for navigation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 21 May 2026
Resolution: New charts added to vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2026
Resolved
Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers. Aft lazarette found with bilge alarm not functioning. Repair/replace as necessary to restore function. Maintain periodic rounds/visual inspection of space during operations until repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 15 May 2026
Resolution: Owner repaired bilge alarm.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 May 2024
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Bulkhead leaking from weather deck through shell at frame 60, within galley overhead, where longitudinal meets deck overhead stringer at "T". Repair leak and ensure no electrical outlets used in vicinity of leak until repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 20 May 2024
Resolution: Deck sealed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2024
Resolved
Accessories, such as switches, fuses, sockets, shall be standard NEC types for the loads to be carried and shall be of types listed by, or types equal to those listed by Underwriters Laboratories, INC, or other recognized testing laboratory. Electrical outlet in galley found without cover with permanently attached outlet extender. Remove extender and replace cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 20 May 2024
Resolution: Plug removed, and replaced.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 17 May 2024
Resolved
(a) A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general
marine radar system for surface navigation with a radar
screen mounted at the primary operating station if:
(1) The vessel is self-propelled;
(2) The vessel has an oceans, coastwise, limited
coastwise or Great Lakes route; and carries more than 49 passengers. Radar inoperable. Repair and demonstrate radar operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2024
Resolved 17 May 2024
Resolution: Radar is in good working order
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 May 2024
Resolved
No marine employer shall engage or employ any person to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. List of P.R.-employment tested crew not available at inspection. Provide list of all crew who were drug tested and enrolled in the company's DAPI program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2024
Resolved 20 May 2024
Resolution: DAPI provided to CG
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2024
Resolved
Portable fire extinguishers shall be located so as to be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. 10-ABC portable extinguisher located on fantail placed without bracket. Install bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 20 May 2024
Resolution: Extra extinguisher removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2024
Resolved
A crew accommodation space and a work space must be of sufficient size, adequate construction, and with suitable equipment to provide for the safe operation of the vessel and the protection and accommodation of the crew in a manner practicable for the size, facilities, service, route, speed, and modes of operation of the
vessel. Forepeak/Chain Locker deck planking broken and unstable. Repair deck planking to ensure safety of
crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 20 May 2024
Resolution: Chain locker floor repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 July 2022
Resolved
SUBMIT PROPOSAL TO ADDRESS AREAS OF WATER INGRESS FOUND DURING IN WATER PORTION OF CREDIT DRYDOCK INSPECITON.
1.ON PORT SIDE LAZZARETE WHERE SIDESHELL MEETS THE STERN
2. ON STARBOARD SIDE LAZARRETE JUST OUTBOARD OF THE EXHAUST PENETRATION, INDICATED BY A RED ARROW
3. LEAKING OVERBOARD VALVE AFT OF THE STARBOARD MAIN ENGINE
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2022
Resolution: Recieved email from vessel Master stating that there has been no observed water ingress, and that the valve in question has been repaired. He also stated that if necessary, they could send a diver down to install additional caulking if needed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 July 2022
Resolved
REMOVE WATER FROM BILGE OF LAZARRETE TO GUAGE AMOUNT OF WATER INGRESS IN THAT SPACE.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2022
Resolution: Recieved photos via email of bilge in lazarette free of water. Another picture was sent 24 hours later, bilge appears the same.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2022
Resolved
Vessel lost main engines due to unknown cause while carrying out man overboard drills. Vessel was adrift in Lake St. Clair and advised to keep the DMI informed of status updates.
Action required: 10 - Deficiency Rectified
Resolved 28 May 2022
Resolution: Captain reported that there was an air lock in the system from the crossover valves between the tanks being closed. Valves were opened, system was removed of air and engines were operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2022
Resolved
SUBMIT PLANS FOR INSTALLATION AND USE OF MONITORING DEVICES TO ENSURE WAKEFULNESS OF THE WATCHMEN
185.410(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Vessel has proposed the use of an alarm system. Details have been forwarded to Type approvals @ MSC for further guidance.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 9 May 2022
Resolved
IMPLEMENT A TRAINING PROGRAM THAT ADDRESSES FIREFIGHTING PROFICIENCY AND MEETS ALL REQUIREMENTS OF THIS PART
185.420(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2022
Resolution: Vessel has submitted a training program for review that meets the intent of this new requirement.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 May 2022
Resolved
CONDUCT AND PROPERLY LOG REQUIRED PASSENGER EGRESS DRILLS
185.507(a)
Action required: 10 - Deficiency Rectified
Resolved 9 May 2022
Resolution: Discussed and ran through with the crew expectations and best practices for passenger egress drills
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 9 May 2022
Resolved
DEVELOP A PASSENGER SAFETY BILL THAT MEETS ALL REQUIRMENTS OF THIS PART
46 CFR 185.515(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2022
Resolved 23 May 2022
Resolution: Vessel provided a passenger safety bill that meets the intent of the regulation
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 9 May 2022
Resolved
POST EMERGENCY INSTRUCTIONS
46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2022
Resolution: Vessel has posted emergency instruction at the pilothouse.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 9 May 2022
Resolved
MARK ACCESS TO UPPER DECK-NO PASSENGERS
46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2022
Resolution: Vessel has posted no passenger sign leading to the upper deck
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 May 2022
Resolved
MMSI IN RADIO DOES NOT MATCH FCC CERTIFICATE
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 June 2022
Resolution: Vessel sent a photo of the correct MMSI number displayed on the radio
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 May 2022
Resolved
LOG DRILS TO INCLUDE DETAILS AS REQUIRED
46 CFR 185.520(f)
Verify at in service inspection
Action required: 705 - Other - as specified
Resolved 14 September 2022
Resolution: Crew has improved upon logging details for drills.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 9 May 2022
Resolved
PROVIDE DEVIATION CARD FOR COMPASS
46 CFR 184.402
To verify at in service inspection
Action required: 705 - Other - as specified
Resolved 14 September 2022
Resolution: Master created a deviation card. Very little deviation was found with the compass, deviation card kept in a binder at the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 9 May 2022
Resolved
DEMONSTRATE UPDATED CHARTS
46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 May 2022
Resolution: Recieved photo showing electronic chart has been updated
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2022
Resolved
RENEW LABEL ON RING LIFE BUOY. ENSURE BATTERIES ARE CHECKED ANNUALLY
46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2022
Resolution: Recieved photo of new label
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 May 2022
Resolved
THE METHOD OF OPENING AN EMERGENCY ESCAPE MUST BE OBVIOUS AND RAPID. LABEL DIRECTION OF OPENING. LABEL WTD'S AS WELL
46 CFR 177.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2022
Resolution: Received photo showing labeling of WTD's and emergency escape
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 May 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2022
Resolution: Captain stated that batteries have been renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2022
Resolved
MARK FUEL AND AIR SHUT OFFS WITH DISTANCE TO PULL
46 CFR 182.435
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2022
Resolution: Received photo via email showing the fuel shut off lines are marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2022
Resolved
DEMONSTRATE TWO MEANS OF OPERATION OF FIXED BILGE SYSTEM
46 CFR 182.520
To be verified at in service inspection
Action required: 705 - Other - as specified
Resolved 14 September 2022
Resolution: Crew tested and labled secondary means of pumping bilges and are now familiar with the operation.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 May 2022
Resolved
REPLACE EMERGENCY LIGHTING IN ENGINE ROOM
46 CFR 183.410
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2022
Resolution: Received email confirmation from Master stating the emergency lighting in the engine room has been repaired.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 May 2022
Resolved
ENSURE ALL ENGINE ROOM VENTS CLOSE COMPLETELY
46 CFR 182.450
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2022
Resolution: Received email confirmation from vessel Master stating the engine room vents have been repaired and can now fully close.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2022
Resolved
WHERE TEMPERATURE EXCEEDS 150 DEGREES PROVIDE INSULATION (PORT AND STARBOARD MAIN ENGINE EXHAUST)
46 CFR 177.970
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 June 2022
Resolution: Recieved photo of newly installed insulation
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2021
Resolved
An independent modular smoke detecting unit must meet UL 217
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 27 May 2021
Resolution: Received attestation from vessel Master stating that smoke detectors are properly mounted and in good working order.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 May 2021
Resolved
Provide proof of enrollment in drug and alcohol program for crew
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 27 May 2021
Resolution: Received attestation from vessel Master stating all crew members are enrolled in a drug testing program, with documentation from the company provided.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 19 May 2021
Resolved
Provide garbage management plan
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Master created garbage management plan
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2021
Resolved
Renew dayshapes
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: vessel had spare day shape on board
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 May 2021
Resolved
Label watertight container with distress signals in 1/" contrasting color
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Master found container and labeled it
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 May 2021
Resolved
Means of escape shall be obvious and rapid. Security pin was found in escape hatch for galley. Provide obvious means for identifying and removing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
Resolution: Received attestation from vessel Master stating a cord was placed on the security pin indicating to pull cord to remove security pin.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2021
Resolved
Wire for power and lighting circuits to be UL boat/marine cable. New installation in galley is not boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 27 May 2021
Resolution: Received attestation from vessel Master stating the wire in question has been replaced with boat cable
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 19 May 2021
Resolved
Doors on cooking appliances must have locking devices to prevent opening in heavy seas. Replace missing latch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 27 May 2021
Resolution: Received attestation from vessel Master stating the latch has been replaced
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2021
Resolved
Provide first aid kist and instructions meeting 46 CFR 160.041
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Master located first aid kit meeting the specification of subch. Q
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2021
Resolved
Remove all flammable liquids or store in approved paint locker.
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Flammable liquids were removed from the vessel
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2021
Resolved
Replace batteries in lifering light and 3-6' lanyard must be UV resistant floating line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 27 May 2021
Resolution: Received attestation from vessel Master stating the line and battery have been replaced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 July 2020
Resolved
Each vessel that operates beyond 3 miles from the coastline of the Great Lakes must have an EPIRB. Hydrostatic release is expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2020
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 July 2020
Resolved
Each vessel must be equipped with a public address system. Fantail PA speaker not working.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 July 2020
Resolved
All escape hatches and other emergency exits used as means of escape must be readily apparent and marked on both sides in clearly legible letters at least 2" high: "EMERGENCY EXIT, KEEP CLEAR". Emergency escape for galley to be labeled from both sides. Emergency escape for engine room to be made readily apparent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2020
Resolved 21 October 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2019
Resolved
Provide proof of annual MIS report Submission.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 1 July 2019
Resolution: Received proof of annual MIS Report Submission.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2019
Resolved
Provide alcohol test strips for compliance with SMI requirements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 1 July 2019
Resolution: Viewed test strips which were approved and within expiration rqmts.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 May 2019
Resolved
Provide current and corrected charts for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 1 July 2019
Resolution: Reviewed corrected charts for area of operation.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 May 2019
Resolved
Provide a current light list for the area of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 1 July 2019
Resolution: Reviewed light list for area of operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 May 2019
Resolved
Forward scuttle to chain locker/fore peak does not have a closure locking devices as manufactured. Make permanent repairs or replace locking device as original.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 1 July 2019
Resolution: Locking device installed as original.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2019
Resolved
Gate valve is leaking fuel oil at the aft engine room bulkhead. Make permanent repairs or renew as original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2019
Resolved 1 July 2019
Resolution: Valve packing tightened with no evidence of fuel oil leak at time of inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2019
Resolved
Conduct drills and provide for crew training to be witnessed by CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2019
Resolution: Witnessed drills.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 8 May 2019
Resolved
Provide records of current drills and EPIRB monthly checks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 1 July 2019
Resolution: Examined record of drills and monthly tests.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2019
Resolved
Starboard engine room bulkhead electrical panel directory is outdated and has a 15A breaker labeled halon relay. The halon system no longer exists although the breaker is on. Provide for new panel description and locate service breaker is feeding.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2019
Resolved 1 July 2019
Resolution: Breaker updated to reflect current CO2 ventillation shutdown function.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 May 2017
Resolved
Provide proof of enrollment within a Drug and Alcohol program for the current year.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Received employee sheet.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 10 May 2017
Resolved
Provide company policy and hotline numbers within crew space for drug and alchol abuse and programs
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Employee displays posted.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 10 May 2017
Resolved
Provide annual list of randoms completed for crew list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Annual results received.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2017
Resolved
Update items within first aid kit which are expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 15 May 2017
Resolution: Kit updated.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 10 May 2017
Resolved
Replace dry-rotted coolant line on the forward generator inboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 15 May 2017
Resolution: Hose renewed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2017
Resolved
Reattach exhaust lagging on starboard exhaust elbow off of main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 15 May 2017
Resolution: Insullation installed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 10 May 2017
Resolved
Remove previously installed system pull handle located just outside of the engine room access.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 15 May 2017
Resolution: Old controls removed.
Lifesaving › Lifebuoys › Serviceable
Issued 10 May 2017
Resolved
Replace two liferings, one forward one aft which have deteriorated grab lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2017
Resolved 15 August 2017
Resolution: Renewed two liferings on the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 May 2016
Resolved
Starboard exhaust piping termination flange in way of the vessels transom is weaping water due to tender wood and one loose screw bolt at the 4 o'clock position. Conduct temporary repairs to to the area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 August 2017
Resolution: All flanges renewed and repacked at drydocking. All sat.
Communications › Radio Communications › EPIRB
Issued 19 May 2016
Resolved
EPIRB battery needs to be renewed. prior to operations beyond three NM from shore.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 August 2017
Resolution: Battery renewed.
Communications › Radio Communications › EPIRB
Issued 19 May 2016
Resolved
Renew vessels hydrostatic release unit.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 August 2017
Resolution: Hydrostatic release renewed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 May 2016
Resolved
[name withheld] Shut off valves.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 August 2017
Resolution: Remote fuel shutoffs marked.
Construction/Loadline › Hull › Hull Plating
Issued 19 May 2016
Resolved
Permenant repairs to both Port and Starboard Transom wood planking in way of both exhaust termination flanges (inner & outer) to be conducted at or before the vessel's next dry dock exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2018
Resolved 15 August 2017
Resolution: Planking renewed in way of the exhaust overboard within the steering compartment.