Records from 1981 to 2026. Most recent: inspection, 10 June 2026.
Inspection history · 88
10 June 2026
Type not recorded
No type recorded · USCGC DANIEL TARR (WPC-1136) · USCG Heartland District (CGD-H) · Activity 8401294
17 March 2026
Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8327484
7 January 2026
Vessel Attendance · Special · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8291546
18 November 2025
Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 8273268
3 June 2025
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8156580
19 March 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8096790
30 December 2024
Spot Check · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8051903
29 February 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7868185
31 October 2023
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7817908
12 June 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7712879
2 February 2023
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7631512
17 September 2022
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7568000
24 August 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7542324
3 July 2022
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7498683
3 February 2022
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7384757
10 September 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7308981
13 January 2021
Administrative Inspection · Hull Examination · Annual Inspection · Deficiency Check · Internal Structural Exam · Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7123725
7 October 2020
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 7074037
6 May 2020
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6978365
8 January 2020
Administrative Inspection · Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6836364
6 August 2019
Type not recorded
No type recorded · USCGC MARLIN (WPB 87304) · USCG Northeast District (CGD-NE) · Activity 6794873
6 February 2019
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6622491
3 April 2018
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 6384705
28 March 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6376173
10 January 2018
Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6335103
30 January 2017
Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6078594
18 April 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5847077
6 January 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5791842
7 May 2014
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4853180
13 February 2012
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4241340
17 December 2011
Type not recorded
No type recorded · USCGC SEAHAWK (WPB 87323) · USCG Southeast District (CGD-SE) · Activity 4210629
3 February 2011
Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3984788
10 February 2010
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3678601
20 April 2009
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3456487
26 February 2009
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3420747
4 November 2008
Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 3357618
7 April 2008
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3176821
14 March 2007
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2887686
29 March 2006
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2619142
1 August 2005
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2448028
28 January 2005
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2282358
17 November 2004
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 2252099
10 March 2004
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2022556
17 November 2003
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1949134
12 June 2003
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1819050
10 April 2003
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1771350
11 March 2002
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1494408
21 August 2001
Hull Examination · Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1395795
27 July 2001
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 26616
14 May 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1379481
29 March 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 819216
18 November 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442954
27 June 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 885918
29 March 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1441563
12 January 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350401
3 March 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452379
28 January 1998
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1388443
28 June 1997
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 32287
9 April 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378011
15 April 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412998
15 March 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412997
29 March 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1374259
28 March 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1166918
7 March 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1166897
17 February 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1164560
14 August 1993
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1158907
14 May 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838834
11 March 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838387
8 July 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 950424
9 March 1992
Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1254705
26 September 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1245422
31 July 1991
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 937202
9 April 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1229370
26 March 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 917319
15 March 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1220624
8 March 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 925246
16 March 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 894047
18 August 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1037269
28 March 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 993121
28 December 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1317117
7 August 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1339234
14 March 1987
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1332706
23 December 1985
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 989197
9 April 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1281336
12 January 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1281335
13 December 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274118
17 November 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272620
22 April 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971971
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 April 2021
Resolved
Test bilge alarm in accordance with 46 CFR 182.530. Fwd bilge alarm was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2021
Resolution: Fwd bilge alarm operative.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 April 2021
Resolved
Inspect engine compartment ventilation closures in accordance with 46 CFR 176.810. Engine room ventilation closures did not close completely.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2021
Resolution: Engine room ventilation closures closed completely.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 April 2021
Resolved
Mark ring buoy in accordance with 46 CFR 185.604. Life buoy was not labeled properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 3 February 2022
Resolution: Ring Buoy observed to be properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 April 2021
Resolved
Mark life float in accordance with 46 CFR 185.604. Life float was not marked properly/ retro reflective tape was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 3 February 2022
Resolution: Life Float observed to be properly labeled with satisfactory retro-reflective tape.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 April 2021
Resolved
Inspect FCC required equipment in accordance with 47 CFR 80.905. DSC radio function was not programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 3 February 2022
Resolution: DSC Radio proplerly installed. Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2021
Resolved
Inspect machinery in accordance with 46 CFR 176.804. Submit repair proposal for fiber patches/pinholes on engine metallic exhaust sections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 3 February 2022
Resolution: Engine metallic exhaust sections have been witnessed to be properly repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 January 2020
Resolved
Vessel was not made available to conduct in-service inspection. Vessel is prohibited from carrying passengers overnight until vessel completes in-service inspection to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2020
Resolved 8 January 2020
Resolution: Completed SPV Overnight Passenger Verification In-service exam
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 February 2019
Resolved
Replace broken escape hatch from crew cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2019
Resolution: Escape hatch replaced, all sat.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 February 2019
Resolved
Update EPIRB registration to reflect vessel call sign.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2019
Resolution: Received proof of EPIRB registration to reflect call sign.
Construction/Loadline › Hull › Stringer
Issued 10 January 2018
Resolved
Remove wasted wood under metal engine mount, STBD and Port side, where discussed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 7 February 2018
Resolution: witnessed
Construction/Loadline › Penetrations › Flange Pad
Issued 10 January 2018
Resolved
Replace doubler on the FWD port side valve through hole.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 31 January 2018
Construction/Loadline › Hull › Transverse Frame
Issued 10 January 2018
Resolved
Treat frame aft of engine on Port Side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 7 February 2018
Resolution: witnessed
Construction/Loadline › Hull › Transverse Frame
Issued 10 January 2018
Resolved
Treat floor frame/transvesre frame AFT of the Engine Port Side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 7 February 2018
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 10 January 2018
Resolved
Replace cutlass bearing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 31 January 2018
Construction/Loadline › Hull › Bracket
Issued 10 January 2018
Resolved
Replace bow sprit mount under side bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 31 January 2018
Engineering › Bilge Water Management System › Pump
Issued 10 January 2018
Resolved
Engine Pump bracket replace, bracket is wasted.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 7 February 2018
Lifesaving › Lifefloat › Lifeline
Issued 30 January 2017
Resolved
Renew the Life Lines on the vessels Life Float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2017
Resolved 1 February 2017
Resolution: Witnessed.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 May 2014
Resolved
Repair fwd compartment bilge alarm audible indication
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2014
Resolution: Vessel repaired bilge alarm
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 May 2014
Resolved
Provide DOT approved alcohol test strips/equipment.
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 14 May 2014
Resolution: Vessel provided DOT approved alcohol test equipment.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2014
Resolved
Provide USCG approved first aid kit.
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 14 May 2014
Resolution: Vessel provided approved first aid kit
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 7 May 2014
Resolved
Repair emergency lighting in accomodation space.
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 14 May 2014
Resolution: Vessel repaired emergency lighting
Communications › Radio Communications › Satellite Communications Capability
Issued 7 May 2014
Resolved
Perform satisfactory test/or provide sat service report for SSB radio
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 14 May 2014
Resolution: Vessel performed sat test.
Fire Fighting › Means of Escape › Blocked
Issued 13 February 2012
Resolved
Provide means of opening FWD emergency escape hatch from both sides.
Due 13 March 2012
Resolved 14 February 2013
Stability › Weathertight Integrity › General
Issued 13 February 2012
Resolved
Install new safety glass for stbd aft cabin window
Action required: 705 - Other - as specified
Due 13 March 2012
Resolved 14 February 2013
Construction/Loadline › Hull › Keel
Issued 3 February 2011
Resolved
Pull two keel bolts for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 3 February 2011
Resolved
Replace raw water intake valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2011
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 3 February 2011
Resolved
Replace "pump out" system valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2011
Construction/Loadline › Hull › Stiffener
Issued 3 February 2011
Resolved
Repair block IWO sewage valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2011
Construction/Loadline › Hull › Keel
Issued 3 February 2011
Resolved
Replace wormshoe where indicated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2011
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 3 February 2011
Resolved
Replace cutlass bearing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2011
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 February 2010
Resolved
Replace wasted main logitudinal frame, port side engine room to fuel tank room.
Action required: 705 - Other - as specified
Resolved 11 February 2010
Documentation › Certificates/Documents › FCC SSL
Issued 7 April 2008
Resolved
Obtain valid safety radio equipment certificate.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 18 April 2008
Lifesaving › Lifebuoys › Serviceable
Issued 7 April 2008
Resolved
Replace life ring buoy and painter 60'.
Due 7 May 2008
Resolved 18 April 2008
Documentation › Certificates/Documents › FCC SSL
Issued 7 April 2008
Resolved
Obtain new radio operator permit for master.
Due 7 May 2008
Resolved 18 April 2008
Documentation › Logs/Records › Logbook (official)
Issued 14 April 2005
Resolved
Provide method of logging training and EPIRB tests. 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 1 May 2005
Resolved 1 August 2005
Resolution: Cleared to the satisfaction of the attending Coast Guard Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2005
Resolved
Mount anchor light in a 360-degree arrangement. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 1 May 2005
Resolved 1 August 2005
Resolution: Cleared to the satisfaction of the attending Coast Guard Marine Inspector.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 April 2005
Resolved
Update navigation publications and obtain rules of the road. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 1 May 2005
Resolved 1 August 2005
Resolution: Cleared to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Hand Flares › Quantity
Issued 14 April 2005
Resolved
Obtain 03 orange smoke day flares. 46 CFR 180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 14 April 2005
Resolved
Demonstrate proper operation of single side band radio. 46 CFR 184.620.
Action required: 705 - Other - as specified
Due 1 May 2005
Resolved 14 April 2005
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 April 2005
Resolved
Replace retro-reflective material on life float and extra life ring buoys. 46 CFR 185.604(i).
Action required: 705 - Other - as specified
Due 1 May 2005
Resolved 14 April 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2005
Resolved
Secure loose wiring in engine room. 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 1 May 2005
Resolved 1 August 2005
Resolution: Cleared to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 March 2004
Resolved
O/O Repaired retro tape on 5 life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Due 10 April 2004
Resolved 10 March 2004
Resolution: Item repaired prior to completing inspection.
Navigation
Issued 14 May 2001
Resolved
PROVIDE NAVIGATION PUBLICATIONS (CG LIGHT LIST, COAST PILOT, TIDES AND CURRENTS TABLE) IAW 46 CFR 184.420 PRIOR TO 14 JUNE01.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 7 March 1994
Resolved
RENEW/PROVIDE ONBOARD 6 ORANGE DAY SMOKE FLARES AND 6 NIGHT RED FLARES WITHA DATE OF MANUFACTOR NO EARLIER THEN MAR92.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Engineering
Issued 7 March 1994
Resolved
AFFIX EMERGENCY FUEL SHUT OFF VALVE REACH ROD TO VALVE.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Documentation
Issued 11 March 1993
Resolved
PROVIDE EVIDENCE OF CHEMICAL TESTING OF ALL MMARINE EMPLOYEES IAW 46CFR16._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Electrical
Issued 11 March 1993
Resolved
PROPERLY MAKE UP ELECTRICAL CONNECTIONS IN JUNCTION BOX THAT FEEDS A/C UNITIN ENGINE ROOM.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Electrical
Issued 11 March 1993
Resolved
PROVIDE DIRECTORY OF CIRCUITS FOR ELECTRICAL DISTRIBUTION PANEL IN ENGINE ROOM.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 11 March 1993
Resolved
ATTACH ELECTRIC BILGE PUMP IN ENGINE ROOM TO ITS MOUNT TO PREVENT SHIFTING.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Documentation
Issued 11 March 1993
Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Lifesaving
Issued 26 March 1991
Resolved
REPAIR/REPLACE OR UNDERGO BUOYANCY TEST TO LIFE FLOAT.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Engineering
Issued 26 March 1991
Resolved
PROVIDE A SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM. SUCH WARNING SHALL BE VISIBLE OR AUDIBLE AT THEENGINE OPERATING STATION._x001C_ _x001C_
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Accommodation/Occupational Safety
Issued 26 March 1991
Resolved
DOUBLE HOSE CLAMP ALL THROUGH-HULL FLEXIBLE HOSE FITTINGS.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Lifesaving
Issued 26 March 1991
Resolved
REPAIR GRAB LINES TO ALL RING BUOYS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Fire Fighting
Issued 26 March 1991
Resolved
INSTALL CG APPROVED FIRE EXTINGUISHER BRACKETS FOR ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Documentation
Issued 14 March 1987
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 14 March 1987
Resolved 14 March 1987
Construction/Loadline
Issued 14 March 1987
Resolved
REPLACE TWO CRACKED WINDOWS IN SALON.
Condition: Unknown
Due 14 March 1987
Resolved 14 March 1987