Records from 1985 to 2011. Most recent: inspection, 31 August 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 75
31 August 2011
Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4130773
25 August 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780087
23 July 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 801266
15 January 1998
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1110348
9 January 1998
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1398822
12 August 1997
Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1445265
5 August 1997
Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1117600
2 August 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1116183
29 June 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 782344
23 June 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1113877
10 April 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1104220
28 March 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1098035
20 February 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1105354
16 February 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1105289
10 January 1997
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1097879
18 December 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 506720
6 December 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1356025
23 October 1996
Permit to Proceed
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1159451
5 September 1996
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1254781
21 May 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404169
10 May 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1398481
10 February 1996
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1186300
12 January 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1447527
5 August 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1189962
30 May 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 872228
6 January 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1141195
14 December 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 491697
25 November 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840143
19 September 1994
Permit to Proceed
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1183027
6 August 1994
Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 865164
17 June 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1328803
3 June 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 861801
27 May 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 180809
24 May 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1170578
22 April 1994
Initial Construction-Excluding Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 848055
22 April 1994
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1410988
2 September 1993
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1139322
7 June 1993
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 829107
3 June 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1133378
13 February 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 163587
6 February 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1139627
21 January 1993
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1143130
10 January 1993
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1139909
8 January 1993
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1354228
18 December 1992
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1132232
4 August 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 945358
11 July 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 166351
7 July 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 962050
9 June 1992
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 945103
10 January 1992
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1262207
6 January 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269721
13 December 1991
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1258509
9 December 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1258255
8 November 1991
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1251257
11 October 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1251706
10 September 1991
Permit to Proceed
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 933821
22 July 1991
Permit to Proceed
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1250224
9 January 1991
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1217334
7 January 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 895537
12 September 1989
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 897065
8 September 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200595
5 January 1989
COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1037300
13 June 1988
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1201230
26 February 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1340748
29 October 1987
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1328790
28 August 1987
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1007594
28 August 1987
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1019401
10 May 1986
Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1295111
28 April 1986
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1296258
24 April 1986
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1307012
31 January 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 997323
20 December 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 985164
30 October 1985
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1294837
7 September 1985
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1299878
15 July 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 992320
Construction/Loadline
Issued 23 July 1998
No resolution recorded
Wastage found in the hull of the reduction gear coffer dam area. The wastage was up to 50 percent in areas with a average of 35 percent over all. The vessel may not operate until this issue is resolved and/or cleared by the Coast Guard.
Condition: Unknown
Due 9 January 1999 — due date passed with no resolution recorded
Navigation
Issued 16 February 1997
Resolved
MAKE ECHO DEPTH SOUNDER OPERABLE.
Condition: Unknown
Due 16 February 1997
Resolved 16 February 1997
Engineering
Issued 10 January 1997
Resolved
MAKE PERMANENT REPAIR TO VENT LINE FOR #3 PORT MIDDLE DOUBLE BOTTOM FUEL OIL TANK.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Construction/Loadline
Issued 10 January 1997
Resolved
MAKE PERMANENT REPAIR TO THE AFTER #1 HOLED BULKHEAD ABOVE WATERTIGHT DOOR #8.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Lifesaving
Issued 10 January 1997
Resolved
RENEW #6 LIFEBOAT EMBARKATION LADDER.
Condition: Unknown
Due 10 January 1997
Resolved 22 January 1997
Lifesaving
Issued 10 January 1997
Resolved
RENEW DETRIORATED BILGE PUMP DISCHARGE HOSES FOR NUMBER'S 3,4,5, AND LIFEBOATS.
Condition: Unknown
Due 10 January 1997
Resolved 22 January 1997
Lifesaving
Issued 10 January 1997
Resolved
REPAIR BROKEN FLOOR BOARD FOR THE #4 LIFEBOAT.
Condition: Unknown
Due 10 January 1997
Resolved 22 January 1997
Fire Fighting
Issued 10 May 1996
Resolved
MAKE PROPER REPAIRS TO AND PROVE PROPER OPERATION OF VESSELS' HILLER SMOKE DETECTION SYSTEM.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Fire Fighting
Issued 12 January 1996
Resolved
REPLACE CLIP RING ON CONTROL VALVE OF FIXED HALON SYSTEM.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Electrical
Issued 12 January 1996
Resolved
REPAIR JAMMED BATTERY LOCKER VENT DOOR.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Fire Fighting
Issued 12 January 1996
Resolved
SERVICE/EXERCISE #3, 4, & 7 FIRE STATION NOZZELS.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Lifesaving
Issued 12 January 1996
Resolved
REPLACE WORN BOLT IN FLEAMING GEAR ON #6 L/B
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Lifesaving
Issued 12 January 1996
Resolved
REPLACE AFT RELEASE GEAR BRACKET ON #5 L/B
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Lifesaving
Issued 12 January 1996
Resolved
SECURE FWD CHAFING PAD ON #2 L/B
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Engineering
Issued 12 January 1996
Resolved
REPAIR WASTED GOOSE NECK VENT INWAY OF FWD DECK LADDER.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Fire Fighting
Issued 12 January 1996
Resolved
REPAIR/TEST EMERGENCY GENERATOR FIXED FF EXHAUST CLOSURE.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Fire Fighting
Issued 12 January 1996
Resolved
REPAIR/TEST PRESSURE SWITCH TO FIZED FF EXHAUST FAN IN GYRO ROOM.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Accommodation/Occupational Safety
Issued 12 January 1996
Resolved
ALLIGN/TEST OPERATION OF #2 WATERTIGHT DOOR.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Engineering
Issued 12 January 1996
Resolved
RENEW MAIN CONDENSER EXPANSION JOINT AT NEXT SCHEDULED DRYDOCK BUT NOT LATER THAN 31JAN97.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Engineering
Issued 12 January 1996
Resolved
REMOVE SAFETY VALVES FROM VESSEL'S TWO FEED PUMPS AND CONDUCT A BENCH TEST AT NEXT SCHEDULED DRYDOCK BUT NOT LATER THAN 31JAN97.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Engineering
Issued 12 January 1996
Resolved
PROVE PROPER OPERATION OF EMERGENCY FUEL OIL SHUT OFF VALVES AT NEXT SCHEDULED DRYDOCK BUT NOT LATER NOT THAN 31JAN97.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 12 January 1996
Resolved
REPAIR TWO INOP GENERAL ALARMS.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Construction/Loadline
Issued 12 January 1996
Resolved
CLEAN OUT TWO ROSE BOXES IN FWD REFER SPACE.
Condition: Unknown
Due 12 January 1996
Resolved 8 February 1996
Navigation
Issued 6 January 1995
Resolved
REPAIR VESSEL'S MAIN SHIP GYRO.
Condition: Unknown
Due 6 January 1995
Resolved 9 January 1995
Electrical
Issued 6 January 1995
Resolved
REPLACE MOTOR HEATER CABLE AT #2 LIFE BOAT WINCH.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Fire Fighting
Issued 6 January 1995
Resolved
FREE UP FIRE DAMPERS THROUGH-OUT VESSEL.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Construction/Loadline
Issued 6 January 1995
Resolved
CLEAN OUT ALL CARGO HOLD BILGE ROSE BOXES 1-5.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Accommodation/Occupational Safety
Issued 6 January 1995
Resolved
LABEL EMERGENCY ESCAPE FROM AFTER SHAFT ALLEY.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Fire Fighting
Issued 6 January 1995
Resolved
REPLACE HOLED DISCHARGE PIPING FOR FIRE/BUTTER WORTH PUMP.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Fire Fighting
Issued 6 January 1995
Resolved
REPAIR FIRE NOZZLES AT STATIONS 3, 9, 11, 16, AND 24.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Fire Fighting
Issued 6 January 1995
Resolved
REPLACE (4) 2 1/2 AND (2) 1 1/2 FIRE HOSES.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Electrical
Issued 6 January 1995
Resolved
RETEST EMERGENCY GENERATOR DUE TO IMPROPER RESETTING ON THE HYDRAULIC GOVERNOR.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Electrical
Issued 6 January 1995
Resolved
RENEW HEATER CABLE TO CONDENSE PUMP IN ENGINE ROOM.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 6 January 1995
Resolved
REPLACE LIFEBOAT RATIONS IN THE #5 AND #6 LIFEBOATS.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Construction/Loadline
Issued 6 January 1995
Resolved
REPLACE MISSING DOGS AND GASKETS FOR WESTHER DECK VENTILATION CLOSURES.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Construction/Loadline
Issued 25 November 1994
Resolved
C/R LOWER STRINGER, STBD SIDE, IN MACHINERY SPACE IWO FR. 131-29.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Construction/Loadline
Issued 25 November 1994
Resolved
IN BALLAST TANK #DBMOS, C/R TANK TOP AREA PRESENTLY REPAIRED WITH DOUBLER PLATE AND PAD WELD, BAY 13, IWO AFT SWASH BLKHD OVER LIGHTENING HOLE.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Construction/Loadline
Issued 25 November 1994
Resolved
IN THE MACHINERY SPACE, PORT SIDE: C/R LOWER PORTION OF VERTICAL STIFFENERS#117, 118, 120, 121, 122 @ 12 INCHES EACH, IWO DECK FLANGE, C LEVEL.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Construction/Loadline
Issued 25 November 1994
Resolved
IN THE MACHINERY SPACE, C/R TO GOOD METAL, DECK FLANGE IWO OF VERTICAL STIFFNER #116 PORT SIDE C LEVEL (BY DRAIN PIPE).
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Construction/Loadline
Issued 25 November 1994
Resolved
IN THE MACHINERY SPACE, C/R LOWER PORTION OF VERTICAL STIFFNERS #116-119 (FRAMES) @12 INCHES EACH, IWO DECK FLANGE, D LEVEL.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Documentation
Issued 25 November 1994
Resolved
PROVIDE COPY OF NEWLY ISSUED PROVISIONAL LOADLINE CERTIFICATE.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Documentation
Issued 25 November 1994
Resolved
PROVIDE COPY OF SHIPYARD STEEL REPORT TO [name withheld].
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Construction/Loadline
Issued 25 November 1994
Resolved
IN CARGO HOLD #3, REPAIR FR 80-83, STBD SIDE IWO CONCRETE PAD.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Construction/Loadline
Issued 25 November 1994
Resolved
IN BALLAST TANK #DBMOS, C/R TANK TOP AREA PRESENTLY REPAIRED WITH SOFT PATCH, BAY 9, IWO OF SIDE SHELL.
Condition: Unknown
Due 25 November 1994
Resolved 25 November 1994
Deck/Cargo
Issued 6 February 1993
Resolved
Motor for anchor windlass was repaired.
Condition: Unknown
Due 6 February 1993
Resolved 11 February 1993
Lifesaving
Issued 8 January 1993
Resolved
PROVIDE APPROVED PLANS FOR ELECTRICAL AND PIPING INSTALLATION TO NEW SHIP SERVICE AIR COMPRESSOR LOCATED "C" DECK.
Condition: Unknown
Due 8 January 1993
Resolved 8 January 1993
Engineering
Issued 8 January 1993
Resolved
SET AND SEAL PORT SUPERHEATER SAFETY PRIOR TO SAILING.
Condition: Unknown
Due 15 January 1993
Resolved 11 January 1993
Construction/Loadline
Issued 8 September 1989
Resolved
CROP OUT OR REPAIR (3 EA) HOLES IN TANK TOP OF AFTER PEAK CENTER LINE APPROX BLKD #211M #217 ABD BK TI FR #213.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
REPAIR SOUNDING TUBE FOR AFTER PEAK AREA.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
CROP OUT OR REPAIR WASTED TANK TOP OF AFTER DECK IN WAY OF AFT PAINT LOCKERFROM BLKD #192 TO BLKD APPROX #202 PORTSIDE.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
CROP OUT OR REPAIR FOREPEAK HATCH COAMING AROUND LOCKNOTCH IN MAIN DECK FWD
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
REPAIR HAND WHEEL ON TOP OF FOREPEAK HATCH COVER.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
REPAIR HOLES IN AFT DAMAGE CONTROL LOCKER AND MAKE IT WATERTIGHT.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
REPAIR DOGS TO THE DOOR OF PAINT LOKCER AFT.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
CROP OUT OR RENEW TO GOOD METAL THREE (3 EA) BOTTOM LONGS IN WAY OF MAN HOLE ACCESS COVER FOR #4 FWD BALLAST TANK PORT DOUBLE BOTTOM.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
CROP OUT OR RENEW BOTTOM LANDING IN WAY OF THE CARGO PUMP ROOM "E" DECK LEVEL FROM ESCAPE TRUNK LANDING.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 8 September 1989
Resolved
REPLACE BOTTOM LANDING STEP PLATE AT "D" DECK LEVEL AT #5 CARGO HOLD EMERGENCY ESCAPE TRUNK.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 5 January 1989
Resolved
CROP AND RENEW CELL GUIDES IN #5 HOLD, "D" DECK, TO GOOD STEEL AS NECESSARYTO SUPPORT BALLAST BLOCKS.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Lifesaving
Issued 5 January 1989
Resolved
REPAIR BROKEN WELDS IN BOTTOM BRACKET OF PORT ACCOMODATION LADDER PRIOR TO 31JULY89. THIS LADDER SHALL NOT BE USED UNTIL PERMANENT REPAIRS ARE MADE.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Lifesaving
Issued 26 February 1988
Resolved
PROVIDE SUFFICIENT BUOYANT APPARATUS FOR THREE (3) PER CENT OF TOTAL NUMBER PERSONS ON BOARD AS PER SOLAS 74 CHAPTER III REGULATION 27 (B)(II).
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Lifesaving
Issued 26 February 1988
Resolved
EQUIP ONE OF THE VESSEL'S MOTOR LIFEBOATS WITH A SEARCHLIGHT AND A RADIOTELEGRAPH INSTALLATION AS PER SOLAS 74 CHAPTER III REGULATION 14 (A)(I).
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Navigation
Issued 28 August 1987
Resolved
PROVIDE A CURRENT MAGNETIC COMPASS DEVIATION TABLE OR GRAPH OR COMPASS COMPARISON RECORD FOR THE STEERING COMPASS IN THE WHEELHOUSE AND AN UPDATEDMANEUVERING INFO FACT SHEET, AS REQUIRED BY 33 CFR 164.35, TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] 11 SEPTEMBER 1987.
Condition: Unknown
Due 28 August 1987
Resolved 28 August 1987
Navigation
Issued 28 August 1987
Resolved
REVISE STEERING GEAR OPERATING INSTRUCTIONS TO REFLECT DELETION OF AFTER STEERING STATION. REVISED INSTRUCTIONS TO BE POSTED IN THE STEERING GEAR ROOM AND ON THE NAVIGATING BRIDGE.
Condition: Unknown
Due 28 August 1987
Resolved 28 August 1987
Accommodation/Occupational Safety
Issued 28 August 1987
Resolved
DETERMINE MAWP AND MAKE AVAILABLE FOR INSPECTION TWO HYDRO- PNEUMATIC POTABLE WATER TANKS IN THE MACHINERY SPACE.
Condition: Unknown
Due 28 August 1987
Resolved 28 August 1987
Deck/Cargo
Issued 24 April 1986
Resolved
RANGE AND CLEAN FOR EXAMINATION PORT AND STBD ANCHOR CHAINS.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Navigation
Issued 24 April 1986
Resolved
COMPLETE UPDATE OF MANUVERING CHARACTERISTICS AND POST IN WHEEL HOUSE.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Unknown
Issued 7 September 1985
Resolved
PROVIDE OILY WATER SEPERATOR CERTIFICATE OF TYPE TEST FOR OILY WATER SEPERATOR.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Navigation
Issued 7 September 1985
Resolved
REPAIR SOUND POWERED PHONES OR REMOVE AND CHANGE DIRECTORIES.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Lifesaving
Issued 7 September 1985
Resolved
REPLACE ROTTMER GEAR BOLTS, FORE & AFT, LIFEBOATS #4 AND #6 AND WEIGHT TEST LIFEBOATS. RENEW RELEASING GEAR BACKLASH SHIELDS #5 FWD AND #4 AFT. UNTIL COMPLETED LIMITED TO -579 PERSONS ON BOARD.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Navigation
Issued 7 September 1985
Resolved
PROVIDE MAG COMPASS CORRECTION CARD AND MANUEVERING INFORMATION.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Construction/Loadline
Issued 7 September 1985
Resolved
PROVIDE CANVAS CLOSURES ON ALL EXPOSED VENTS AND DUCTS AS NECESSARY.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Construction/Loadline
Issued 7 September 1985
Resolved
PERMANENTLY REPAIR TWO POTABLE WATER TANK DRAINS TO BILGE WELL IN CH 3 LOWER LEVEL.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Construction/Loadline
Issued 7 September 1985
Resolved
CROP AND RENEW INTERIOR BULKHEAD, FOC'S'L DECK LOCKER PRIOR TO NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Unknown
Issued 7 September 1985
Resolved
CLEAN HOSPITAL AND PROPERLY STOW ALL SUPPLIES.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Unknown
Issued 7 September 1985
Resolved
TEST OILY WATER SEPERATOR OPERATION.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Construction/Loadline
Issued 7 September 1985
Resolved
CLEAN OIL FROM SHAFT ALLEY BILGES AND SURROUNDING FRAMING.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Electrical
Issued 7 September 1985
Resolved
REPAIR GENERAL ALARM/RADIO BATTERY CHARGER.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Unknown
Issued 7 September 1985
Resolved
LABELS ON P/S OILY WATER DISCHARGE VALVES AT DECK STATIONS.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Engineering
Issued 7 September 1985
Resolved
RENEW EXPANSION JOINT BETWEEN MAIN CONDENSER AND MAIN CIRCULATING PUMP PRIOR TO NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Construction/Loadline
Issued 7 September 1985
Resolved
REPLACE HOUSE A/C REMOTE SHUTDOWN BREAKER AND TEST SHUTDOWN.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Unknown
Issued 7 September 1985
Resolved
PROVIDE UP TO DATE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Lifesaving
Issued 7 September 1985
Resolved
PROVIDE EIGHT 25 MAN LIFERAFTS - DAVIT LAUNCHED; NUMBER OF PERSONS ON BOARD LIMITED TO -522- UNTIL COMPLETION.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Lifesaving
Issued 7 September 1985
Resolved
DEMONSTRATE LAUNCHING OF LIFEBOATS AND DAVIT LAUNCHED LIFERAFTS IN NOT MORETHAN 30 MINUTES AS PER 46 CFR 75.27-5(F) AND SOLAS 74, REQ 29. NUMBER OF PERSONS ON BOARD LIMITED TO -522- UNTIL COMPLETION.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Lifesaving
Issued 7 September 1985
Resolved
PROVIDE FLOAT-FREE LIFERAFTS FOR AN ADDITIONAL -115- PERSONS; NUMBER OF PERSONS LIMITED TO -240- UNTIL COMPLETION.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985
Fire Fighting
Issued 7 September 1985
Resolved
PROVIDE FIRE DETECTION & ALARM SYSTEMS ON E DECK BERTHING AREA.
Condition: Unknown
Due 7 September 1985
Resolved 7 September 1985