MAURY USCG vessel records
← All vessels

NEMO ADVENTURE

NEMO ADVENTURE is a 1995 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in May 2026, along with 64 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 7 May 2026.

Built
1995
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM2579
446517
Flag
UNITED STATES
Maury page id
psix-446517

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.0 ft
Registered tonnagegross 7 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGALAIDI CORP · TAMUNING, GU, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portMERIZO, GU
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

7 May 2026 In-Service Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8368365
30 September 2025 COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8243804
7 January 2025 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8059189
5 June 2024 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7927433
5 September 2023 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7786593
5 January 2023 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7616630
13 June 2022 Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7477740
1 September 2021 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7303083
7 June 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7218009
23 October 2020 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7092028
16 June 2020 Drydock Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6977950
4 December 2019 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6866725
23 October 2019 Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6840809
20 June 2018 Drydock Exam · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6456224
5 June 2018 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6617112
26 January 2018 Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6345118
12 October 2016 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6019721
23 June 2016 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5948720
29 April 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5865250

Deficiency record · 64

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Unapproved RPM limiter bypass installed. Engines are to be serviced by certified engine manufacturer to determine cause of RPM limiter being activated. Provide servicing tech report. Remove RPM limiter bypass if deemed necessary by service tech to ensure safety of engines, returning engines to OEM status. 46 CFR 182.200(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2025
Resolution: Modifications removed. Neutral throttle limiter replaced, O2 sensor replaced. Sea trials conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2025 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Unapproved fuel hoses being used. Replaced with approved SAE-J1942 hoses. 46 CFR 182.720(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 13 November 2025
Resolution: Fuel hoses replaced with SAE-J1527 (recreation use). The fuel hoses are less than 30 inches, approved configuration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Manual fuel pump on both engines' fuel line are dry-rotted. Replace in kind. 46 CFR 182.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2025
Resolved 13 November 2025
Resolution: Fuel pump replaced.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 January 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:(1) A space with a through-hull fitting below the deepest load waterline. Bilge high level alarm was not operational in the starboard side hull bilge space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 January 2025 Resolved
A portable hand bilge pump must be capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. Hand bilge pump onboard vessel was not functional as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2025
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 January 2025 Resolved
Except as provided in §§ 80.177 and 80.179, operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required below. The operator is responsible for the proper operation of the station. Crew was unable to provide an operator license.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 7 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2023 Resolved
A vessel must carry one floating waterlight. Vessel is restricted to day time operations until repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 5 January 2023 Resolved
A vessel must carry one floating waterlight. Vessel is restricted to day time operations until repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2023
Resolved 18 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 September 2021 Resolved
Strainers must be the type of opening on top for cleaning screens. Replace the existing fuel oil filter with a suitable metal marine type strainer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 8 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 September 2021 Resolved
A drip pan fitted with flame screens must be installed under gasoline strainers. Install drip pans fitted with flame 30X30 flame screen mesh under both fuel filter devices.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 28 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 September 2021 Resolved
Each flare carried to meet this section must be stowed in one of the following: A portable watertight container marked as required by §185.614 of this chapter. The existing flare container is not too small, replace with an appropriately sized watertight container and ensure it is properly labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 28 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 September 2021 Resolved
As intended for the intended voyage, a vessel must carry adequate and up-to-date: (1) U.S. Coast Pilot or similar publication; (2) Tide Tables. Provide current publications for U.S. Coast Pilot and Tide Tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 28 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 September 2021 Resolved
Life preservers for children, when provided, shall be stowed separately. The adult and children life preservers are stowed in the same container with no divider. In addition, the container is not secured to prevent shifting while underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 28 September 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 September 2021 Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage. Port and starboard hatch cover fasteners for hull access lids are broken and unable to be secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 28 September 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 September 2021 Resolved
On a vessel at least 7.9 meters (26 feet) in length, a visual and audibe alarm must be provided at the operating station to indicate a high water level in each of the following normal unmanned spaces. The port side compartment visual high water indicating light does not illuminate at the operator station when activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 28 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 September 2021 Resolved
Ships must have the radio equipment required by this subpart must be maintained to provide the availability of the functional requirements specified by 47 CFR 80.1081. The FCC Safety Certificate is expired and the call sign is incorrect. 47 CFR 80.1081
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 28 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 September 2021 Resolved
A vessel must carry one floating waterlight, unless it is limited to day time operation. The waterlight onboard is fitted with the incorrect battery type and the waterlight body is not watertight. Vessel is restricted to daylight operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 28 September 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 December 2020 Resolved
A vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station. Prove operation of starboard side high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 December 2020 Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018. Replace deteriorated retro-reflective tape on 4 x adult and 1 x children life jackets with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2020
Resolved 13 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 December 2020 Resolved
Each floating waterlight installed on a vessel after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion resistant clip. Replace clip attached to buoyant light with a new corrosion resistant clip and of a strength of at least 50 pounds.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2020
Resolved 13 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 15 December 2020 Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must be buoyant, be of at least 60 ft. in length, non-kinking, have a diameter of at least 5/16”, have a breaking strength of at least 1,124 pounds, and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Replace deteriorated lifeline on ring life buoy with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2020
Resolved 13 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 December 2020 Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q of this chapter or other standard specified by the Commandant. Replace waterlight with damage cover and missing watertight gasket with a USCG approved floating waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 13 January 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 December 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Repair stern light and prove operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2020
Resolved 13 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 December 2020 Resolved
Each life jacket and ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. Multiple lifejackets temporary marked with the vessel’s name that had come off. Remark lifejackets with vessel’s name to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2020
Resolved 13 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 December 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel first aid kit with expired contents. Replace with new and ensure kit is equipped with contents required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2020
Resolved 13 January 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 December 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication and Coast Guard Light List. Vessel missing U.S. Coast Pilot and Light List. Replace with new and maintain on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2020
Resolved 13 January 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 December 2020 Resolved
Each vessel certificated to operate on a limited coastwise route within three miles of land in warm water with an EPIRB must be a FCC Type Acceptable Category I 406 MHz EPIRB, installed to automatically float free and activate. NOAA registration for vessel’s EPIRB expired on 18JUL2020. Renew EPIRB registration with NOAA.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 October 2020 Resolved
An inspection for renewal of a COI is conducted to determine if the vessel is in satisfactory condition, fir for the service intended and complies with all applicable regulations. Vessel's COI expired on 23OCT2020. Prior to carrying passengers for hire, vessel owner/operator must complete a COI for renewal to the satisfaction of the attending USCG Marine Inspector. Submit CG3752 to Sector Guam to schedule COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 December 2019 Resolved
46CFR185.604: Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Discovered 15 adult lifejackets with water damaged SOLAS reflective tape. Replace reflective tape with new and USCG approved.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 December 2019 Resolved
46CFR185.640: Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Remark vessel's name at least 2" block letters on adult lifejackets. Total of 15 adult lifejackets inspected without vessel's name.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2019 Resolved
46CFR177.900: rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section. Repair damaged port side netting to as original.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 December 2019 Resolved
46CFR185.614: Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”.Storage box for distress flares were stored in a non-watertight container with moisture where first aid kit is also stored. Replace unapproved container with watertight container for storing flares.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2019 Resolved
46CFR177.900: Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The point and uniform loads do not need to be applied simultaneously. Repair and secure loose aft deck rail to deck to as original.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2019 Resolved
46CFR182.610: A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. Unapproved repair made to steering linkage using a bolt to secure connecting rods in place. Repair steering linkage in accordance with manufacturer's recommendation.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2019 Resolved
46CFR182.410: In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Replace unapproved fuel hoses with USCG approved (SAE J-1942) and double clamped hoses on both ends.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 December 2019 Resolved
46CFR182.530: Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers. Secure high water alarm in starboard hull to prevent from damage and for float switch to activate as intended when there is presence of water in space.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 December 2019 Resolved
46CFR185.516: Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Replace missing placard containing instructions for donning and use of life jackets onboard.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2019 Resolved
46CFR16: Submit proof of company drug testing program for crewmembers employed in a safety sensitive position on NEMO ADVENTURE. Operator unable to provide proof to attending USCG MI upon request of company drug testing program for vessel captain and deckhand.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 December 2019 Resolved
46CFR181.500: Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection. Replace port and starboard portable fire extinguisher with gage in red, wastage around neck and discharge hose with rot.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 December 2019 Resolved
46CFR181.520: Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Replace wasted bracket for securing portable fire extinguishers with new or optional, replace with local approved alternative to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 December 2019 Resolved
46CFR80.905: Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Reprogramm vessel's MMSI in VHF radio and demonstrate DSC test to attending USCG MI.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 December 2019 Resolved
46CFR182.530: On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: Visibly mark/label port and starboard high water alarms at operating station.
Action required: 705 - Other - as specified
Due 9 December 2019
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2019 Resolved
46CFR176.700: Internal inspection of port side hull with delamination on forward most deck crossbeam. Remove delamination and repair to original thickness to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 4 January 2020
Resolved 11 December 2019
Resolution: MI attended vessel and inspected satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 June 2018 Resolved
46 CFR 177.300: Remove standing water in port side hull forward of collision bulkhead and determine cause of water intrusion.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 7 June 2018
Resolution: Water removed; cause of water intrusion is through forward port cleat in way of collision bulkhead. To be repaired at upcoming dry dock scheduled in late June 2018.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 June 2018 Resolved
46 CFR 185.728: Missing entries for monthly EPIRB tests.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 7 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2018 Resolved
46 CFR 180.78: Child and adult life jackets stowed in one bin. Install divider to separate adult and child life jackets in port side stowage bin.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 7 June 2018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 June 2018 Resolved
46 CFR 177.900: Replace missing ropes/rungs for all four entry embarkation stations.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 7 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 June 2018 Resolved
46CFR180.68: Vessel is required to have 6 orange and 6 red handheld flares as a condition for operating on a LBS and Limited Coastwise. Vessel only had 4 combination USCG approved handheld flares.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 7 June 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 June 2018 Resolved
46CFR181.610: Required to have 3 x 2.5 gallon buckets; only one onboard during inspection.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 7 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2018 Resolved
46CFR183.200/210: Replace battery cable with corroded connector with new. Battery is stored underneath operating station.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 7 June 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 June 2018 Resolved
46CFR182.530: Replace missing high water indicator light at operating station for port side hull.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 7 June 2018
Engineering › Bilge Water Management System › Pump
Issued 26 January 2018 Resolved
46 CFR 182.500 (a): Replace starboard side overboard bilge pump with new and prove operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2018
Resolution: Replaced and proof of operation made to the satisfaction of the attending MI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 January 2018 Resolved
46 CFR 182.530: Repair inoperable port and starboard high water alarm indicator lights with new and prove operation.
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 10 March 2018
Operations/Management › Drills/Instruction › Safety Orientation
Issued 26 January 2018 Resolved
46 CFR 185.510: Replace and post missing emergency instruction list.
Due 27 January 2018
Resolved 26 January 2018
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 26 January 2018 Resolved
46 CFR 184.510: Replace and post deteriorated emergency broadcast placard near VHF radio.
Due 27 January 2018
Resolved 26 January 2018
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 January 2018 Resolved
46 CFR 184.420 (a)(2): New publications for area of operation and local Notice to Mariners to be current and on board vessel at all times.
Due 27 January 2018
Resolved 26 January 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 January 2018 Resolved
46 CFR 183.200 (b): Replace wire for navigational light with new. Insulation for lead wire is deteriorated exposing wire inside potential for shortage to occur.
Action required: 705 - Other - as specified
Due 29 January 2018
Resolved 26 January 2018
Electrical › Electric Supply System (service) › Cable
Issued 26 January 2018 Resolved
46 CFR 183.350 (d) Connections must be made to battery terminals with permanent type connectors. Observed an unconnected battery cable no longer in use on No. 2 switch box; remove switch box or properly secure.
Due 29 January 2018
Resolved 26 January 2018
Construction/Loadline › Hull › Stiffener
Issued 26 January 2018 Resolved
Replace with new 1 x 1 stiffeners with wood rot along inboard port side shell between frames 3 and 4. (Submit repair proposal to USCG for review/approval no later than 31JAN2018)
Action required: 705 - Other - as specified
Resolved 6 February 2018
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 January 2018 Resolved
Replace with new 4 x 6 overhead beam with wood rot in starboard side hull in way of forward collision bulkhead. (Submit repair proposal to USCG for review/approval no later than 31JAN2018)
Action required: 705 - Other - as specified
Resolved 20 February 2018
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 October 2016 Resolved
46 CFR 176.700: Starboard side ladder used by passengers to enter/exit water is held in place by two hull penetrations made to the deck that are capped off with two sink drain plugs when not in use. Submit proposal to USCG to make watertight for review.
Due 28 November 2016
Resolved 2 May 2017
Resolution: Verified permanent repairs made to the satisfaction of attending MI. O/O uses removable dense foam to cover vertical supports when ladder is not used by passengers to enter/exit water.
Navigation › Piloting/Steering › Magnetic Compass
Issued 12 October 2016 Resolved
46 CFR 184.402: Prove proper operation of light for compass.
Due 14 October 2016
Resolved 1 December 2016
Fire Fighting › Fire Bucket › Quantity
Issued 12 October 2016 Resolved
46 CFR 181.610: A vessel not required to have a power driven fire pump must have three 9.5 liter buckets, with an attached lanyard. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket.
Due 14 October 2016
Resolved 1 December 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 12 October 2016 Resolved
Wasted mounting bracket. Vessel representative request to submit an alternative for fire extinguisher mount due to constant replacement of metal band and clip.
Due 14 October 2016
Resolved 7 November 2016
Resolution: Alternative fire extinguisher mount approved by OCMI on 03NOV16 and inspected on 07NOV16.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.