MAURY USCG vessel records Sign in
← All vessels

THE MONSEIGNEUR

THE MONSEIGNEUR is a 1959 tank ship. The Coast Guard has recorded 59 inspections since 1997, most recently in March 2010, along with 52 deficiencies, 5 operational controls and 2 casualty investigations between 2004 and 2009.

Records from 1997 to 2010. Most recent: inspection, 15 March 2010.

Built
1959
Last inspected
15 March 2010
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5137901 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
446625
Flag
UNITED STATES
—
Maury page id
psix-446625

Inspections, by type

…with no type recorded18
Years with a record 14 calendar years (1997–2010)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)642.3 ft × 90.0 ft × 53.8 ft
Registered tonnagegross 23,543 / net 10,570
ITC dimensions (L × B × D)642.3 ft × 90.0 ft × 53.8 ft
ITC tonnagegross 23,543 / net 10,570
BuilderAVONDALE INDUSTRIES INC · AVONDALE, LA, UNITED STATES · built 1959
Hull materialSteel
PropulsionSteam Turbine
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 5 March 2010 · expires 31 March 2011
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23543 - Convention (Subpart B), Gross Ton
10570 - Convention (Subpart B), Net Ton
39483 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OSG INDEPENDENCE Towing Vessel · MISLE 183923 · 28 May 2004 · activity 2381187

Inspection history · 59

15 March 2010 ACP COI Oversight · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3696516
1 February 2010 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3673392
1 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3519993
17 March 2009 Ballast Water Examination · ACP Annual Oversight · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3435195
22 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3305943
14 February 2008 Examination of Repairs · MTSA/ISPS Verification · ACP COI Oversight · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3147596
21 November 2007 Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3102183
8 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3053199
15 July 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2995161
6 March 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2883058
4 January 2007 Ballast Water Examination · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2854863
11 October 2006 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2798435
20 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2629298
16 February 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2586788
25 January 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2573602
28 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2541902
28 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2541921
28 November 2005 ACP Periodic Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2541934
19 October 2005 MTSA/ISPS Verification · ACP COI Oversight · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2511988
16 December 2004 ACP Annual Oversight
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2260816
14 November 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2240736
9 June 2004 MTSA/ISPS Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2093265
29 May 2004 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2081586
28 May 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2381187
20 May 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2073130
15 January 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1986057
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979916
27 October 2003 Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1934623
29 September 2003 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1916301
24 July 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1855762
15 May 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1794824
12 April 2003 Administrative Inspection
Administrative · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1773261
5 April 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1768573
19 March 2003 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1759629
31 January 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1737907
24 January 2003 ACP COI Oversight
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1731809
10 November 2002 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1705011
8 November 2002 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1702725
14 January 2002 Administrative Inspection
Administrative · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1480109
1 October 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1075513
26 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 469859
13 February 2001 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058287
22 January 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1056527
24 October 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1389214
23 October 2000 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426483
2 September 2000 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1365970
12 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 175048
15 April 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 817360
21 September 1999 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450345
10 August 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1112170
24 December 1998 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 807576
16 November 1998 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1427595
9 November 1998 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803444
24 April 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 25581
28 February 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 477682
2 February 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1121461
6 November 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1119618
5 November 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 94922
22 September 1997 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465930

Deficiency record · 52

Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 1 July 2009 Resolved
Vessel experianced a loss of propulsion while transiting the houston ship channel. vessel required to make repairs prior to departure from port.
Due 1 July 2009
Resolved 2 July 2009
Resolution: Attended by USCG inspectors and found to be in satisfactory operable condition.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 17 March 2009 Resolved
Bilge System arrangement allows for discharge directly overboard without a means to monitor the PPM. This system is independent from the installed Oily Water Separater. Although the valve has security seals through the handle and around the valve body, the vessel could not provide a drawing that reflects the arrangement.
Condition: Improper Installation
Due 17 May 2009
Resolved 5 June 2009
Resolution: Received class report attesting to satisfactory bilge pump arrangement with appropriate diagrams.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 4 January 2007 Resolved
Vessel required to provide statement of voluntary compliance letter in accordance w/MOC Policy letter 05-02 from U.S. Coast Guard or authorized classification society.
Due 4 March 2007
Resolved 3 March 2007
Resolution: Submitted SOVC for Air Pollution Prevention
Lifesaving › Lifeboat › Propulsion Engine
Issued 16 February 2006 Resolved
MAKE PERMANENT REPAIRS TO VESSEL'S STBD INOP L/B ENGINE.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2006
Resolution: NEW FUEL INJECTOR PUMP INSTALLED; ENGINE OPERATIONALLY, ALL SAT
Deck/Cargo › Cargo Heating › General
Issued 15 January 2004 Resolved
Repair or replace deck cargo heating steam piping in way of leaks. LEGACY COMPONENT DESC: Steam Piping
Condition: Improper/Lack of Maintenance
Due 15 February 2004
Resolved 14 November 2004
Resolution: ABS surveyor attended vessel and noted that the vessel''s deck steam return line/cargo heating system return line was renewed and found to be satisfactory.
Documentation › Safety/Response Plans/Programs
Issued 24 January 2003 Resolved
Update fire control plan to indicate number and location of all EEBDs. Update legend of symbols to reflect EEBDs. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 24 February 2003
Resolved 31 January 2003
Resolution: Cleared by MSO Long Island Sound.
Engineering › Sea-water System (primary cooling)
Issued 24 January 2003 Resolved
Renew packing for leaking salt water service pump. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 31 January 2003
Resolution: Cleared by MSO Long Island Sound.
Fire Fighting › Ventilation Systems › Ducts
Issued 24 January 2003 Resolved
Prove proper operation of ventilation louvers for e-gen space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 31 January 2003
Resolution: Cleared by MSO Long Island Sound.
Engineering
Issued 10 November 2002 Resolved
Make permanent repairs to the ship service turbo generator prior to departing the port of New York. Vessel must obtain a written class report from ABS surveyor attesting to the proper operation of generator
Due 10 November 2002
Resolved 13 November 2002
Operations/Management
Issued 10 November 2002 Resolved
Prior to entering the port of New york, two tugs with a combined horsepower of no less than 10% of the dead weight tonnage must be provided to escort the vessel during any transits within the port until generator is tested and proven satisfactory to an ABS surveyor.
Due 10 November 2002
Resolved 13 November 2002
Operations/Management
Issued 10 November 2002 Resolved
Upon receipt of cg-835 master shall sign and stamp each requirement and in return fax back to activities as acknowledged.
Due 10 November 2002
Resolved 13 November 2002
Electrical
Issued 13 February 2001 Resolved
PROVIDE A TUG ESCORT FOR ALL MOVEMENTS WITHIN THE PORT OF NEW YORK UNTIL THE COOLER OF THE #2 LUBE OIL COOLER IS REPAIRED. REPAIRS MUST BE TO THE SATSIFACTION OF CLASS. ONCE THIS REPORT IS PROVIDED TO USCG, THIS REQUIREMENT IS CONSIDERED SATISFIED.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Construction/Loadline
Issued 24 October 2000 Resolved
REPAIR ALL WATERTIGHT HATCHES IN LOWER FIRE ROOM. (FREE DOGS AND HINGES)
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Construction/Loadline
Issued 24 October 2000 Resolved
PROVE PROPER OPERATION OF THE ODME
Condition: Unknown
Due 23 November 2000
Resolved 8 November 2000
Fire Fighting
Issued 24 October 2000 Resolved
INSTALL FIRE DOORS AS REQUIRED BY SOLAS 60 IN STAIRWELLS.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Accommodation/Occupational Safety
Issued 24 October 2000 Resolved
CROP AND RENEW WASTED DECK STANCHIONS LOCATED ON LOWER LEVEL OF THE FIRE ROOM AND MACHINERY SPACE BILGE.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Construction/Loadline
Issued 24 October 2000 Resolved
REMOVE SANDPIPER PUMP AND ASSOCIATED PIPING IN AFT STEERING ROOM.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Construction/Loadline
Issued 24 October 2000 Resolved
RENEW FWD LADDER RUNGS IN AFT PEAK TANK.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 24 October 2000 Resolved
PROVE PROPER OPERATION OF ALL FIRE DAMPERS. (CABLES SEIZED AND PINS PAINTEDIN PLACE)
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Accommodation/Occupational Safety
Issued 24 October 2000 Resolved
PROVE PROPER OPERATION OF MAIN DECK (CREW'S ACCOMODATION) TOILETS.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Lifesaving
Issued 24 October 2000 Resolved
REMOVE ALL FLAMMABLE/COMBUSTIBLE LIQUIDS FROM EXISTING PAINT LOCKER AND VARIOUS STOWAGE AREAS THROUGHOUT THE VESSEL AND PLACE IN TEMPORARY STOWAGE ON DECK. SUBMIT PLANS TO MSC FOR APPROVAL OF NEW PAINT LOCKER.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 24 October 2000 Resolved
RENEW/REPAIR ALL SELF CLOSURE DEVICES ON CLASS "A" FIRE DOORS LOCATED IN THE FIRE ROOM, MACHINERY SPACE AND STAIRWELLS.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Electrical
Issued 24 October 2000 Resolved
REMOVE DC PLUG AND PROPERLY PLUG STUFFING TUBE IN LOWER FIRE ROOM.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Engineering
Issued 24 October 2000 Resolved
CALIBRATE MAIN BOILER PRESSURE GAUGES
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Engineering
Issued 24 October 2000 Resolved
RENEW 10 INCH 150# ATMOSPHERIC OVERBOARD VALVE
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 24 October 2000 Resolved
MAKE PERMANENT REPAIRS TO HPU COOLANT/FOAM RAW WATER LINE IWO SOFT PATCH.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Construction/Loadline
Issued 24 October 2000 Resolved
RENEW AFT PEAK TANK WATERTIGHT HATCH.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Navigation
Issued 24 October 2000 Resolved
REMOVE ALL PACKING RINGS FROM RUDDER SHAFT PACKING GLAND FOR INSPECTION OF RUDDER POST AND GLAND LANDING RING DUE TO EXCESSIVE LEAKAGE.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Accommodation/Occupational Safety
Issued 23 October 2000 Resolved
PROVE PROPER OPERATION OF MAIN DECK TOILETS
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Construction/Loadline
Issued 23 October 2000 Resolved
REWORK THE WATERTIGHT HATCHES IN THE LOWER FIRE ROOM.
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Engineering
Issued 23 October 2000 Resolved
REPLACE THE 10" 150# ATMOSPHERIC OVERBOARD VALVE
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Engineering
Issued 23 October 2000 Resolved
MAKE PERMANENT REPAIRS TO WASTED HPU RAW WATER LINE
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Construction/Loadline
Issued 23 October 2000 Resolved
CROP AND RENEW WASTED AFT PEAK WATERTIGHT HATCH
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Navigation
Issued 23 October 2000 Resolved
REMOVE ALL PACKING FROM THE RUDDER SHAFT PACKING GLAND FOR INSPECTION AND RENEW AS REQUIRED
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Unknown
Issued 23 October 2000 Resolved
REMOVE THE SANDPIPER PUMP AND ASSOCIATED OVERBOARD PIPING IN AFT STEERING ROOM
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Fire Fighting
Issued 23 October 2000 Resolved
INSTALL FIRE DOORS IN STAIRWELLS AS REQUIRED BY SOLAS 60
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Lifesaving
Issued 23 October 2000 Resolved
REMOVE ALL FLAMMABLE AND COMBUSTIBLE LIQUIDS FROM EXISTING PAINT LOCKER ANDVARIOUS STOWAGE AREAS THROUGHOUT THE VESSEL AND PLACE IN TEMP STORAGE ON DECK
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Fire Fighting
Issued 23 October 2000 Resolved
PROVE PROPER OPERATION OF ALL SELF CLOSING FIRE DOORS
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Fire Fighting
Issued 23 October 2000 Resolved
PROVE PROPER OPERATION OF ALL FIRE DAMPERS
Condition: Unknown
Due 23 October 2000
Resolved 7 November 2000
Engineering
Issued 2 September 2000 Resolved
Make permanent repairs to governor system to aft turbine generator.
Condition: Unknown
Due 2 September 2000
Resolved 26 September 2000
Navigation
Issued 2 September 2000 Resolved
Make repairs to 10 cm radar. (Electrical/Electronic damage caused by electrical surge from aft turbine generator - See item 001)
Condition: Unknown
Due 2 September 2000
Resolved 26 September 2000
Deck/Cargo
Issued 21 September 1999 Resolved
SUBMIT PROPOSAL AND REPAIR THE 3" FRACTURED WELD ON THE MAIN HYDRAULIC COOLING WATER LINE.
Condition: Unknown
Due 21 September 1999
Resolved 22 September 1999
Fire Fighting
Issued 21 September 1999 Resolved
PROPERLY LABLE ALL VENTALATION CLOSURES
Condition: Unknown
Due 21 September 1999
Resolved 22 September 1999
Electrical
Issued 21 September 1999 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE F/O CUT OUT VALVE
Condition: Unknown
Due 21 September 1999
Resolved 22 September 1999
Navigation
Issued 10 August 1999 Resolved
Vessel to make permanent repairs to inoperative 10cm radar prior to departing Port of New York.
Condition: Unknown
Due 10 August 1999
Resolved 11 August 1999
Fire Fighting
Issued 16 November 1998 Resolved
PROVE PROPER OPERATION OF AFT PORT POOP DECK BOILER ROOM SUPPLY VENT DAMPER.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 16 November 1998 Resolved
RENEW RETRO TAPE ON PORT AND STBD LIFEBOATS.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Engineering
Issued 16 November 1998 Resolved
REPAIR OR RENEW PORT BOILER SUPER HEATER SAFETY VALVE TO DECREASE AMOUNT OFBLOW DOWN TIME THAT VALVE IS REMAINING OPEN. (THE LIFT SETTING WAS SATISFACTORY)
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Engineering
Issued 16 November 1998 Resolved
REPAIR OR RENEW STBD BOILER FORWARD DRUM SAFETY VALVE TO INCREASE AMOUNT OFBLOW DOWN TIME THAT VALVE IS REMAINING OPEN. (LIFT SETTING, SATISFACTORY)
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Electrical
Issued 16 November 1998 Resolved
LOCATE AND REMOVE 440 VOLT GROUND LOCATED ON MAIN DISTRIBUTION PANEL.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Fire Fighting
Issued 16 November 1998 Resolved
INSTALL AND PROVE PROPER OPERATION OF EIGHT (8) DOOR CLOSURES FOR DOORS LEADING TO ENGINE ROOM FROM ACCOMMODATION SPACES, POOP DECK AND UPPER LEVELDECK.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Deck/Cargo
Issued 22 September 1997 Resolved
REPAIR OR REPLACE PORT AND STBD ANCHOR WILDCATS AND TEST IAW ABS REQUIREMENTS TO THE SATISFACTION OF AN ABS SURVEYOR. PROVIDE EVIDENCE OF ABS ACCEPTANCE OF ANCHORING SYSTEM._x001C_ _x001C_
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997

Casualty record · 2

28 May 2004Routine · role: Involved in a Marine Casualty · activity 2381187
30 June 2009Routine · role: Involved in a Marine Casualty · activity 3527785
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.