Records from 1997 to 2011. Most recent: inspection, 30 August 2011.
Inspection history · 91
30 August 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4131697
28 March 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3704591
1 March 2010
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3687787
1 February 2010
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3673410
9 December 2009
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3647631
25 March 2009
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3435768
21 March 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3437591
7 March 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3429288
2 August 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3287484
6 July 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3258861
31 May 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3223037
7 April 2008
ACP Annual Oversight · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3176244
13 February 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3147216
5 January 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3125218
4 January 2008
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3124756
29 December 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3122543
19 November 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3100846
12 June 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2959986
30 May 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2946626
8 May 2007
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2924986
7 May 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2952585
30 March 2007
MTSA Verification · Ballast Water Examination · ACP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2898191
18 March 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2890062
29 January 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2863518
23 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862116
22 January 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2864154
16 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2856476
6 May 2006
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2642187
6 May 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2643834
20 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2629341
20 April 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2629740
8 March 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2646351
11 January 2006
Ballast Water Examination · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2559823
28 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2541882
28 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2541915
8 November 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2530934
29 June 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2408314
5 April 2005
ACP Annual Oversight · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2326019
1 October 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2216433
14 June 2004
MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2094491
8 April 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2040194
12 February 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2005902
12 February 2004
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2005936
27 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1994469
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979913
26 April 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1780983
24 March 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1762071
12 December 2002
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1717904
4 October 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1683368
12 September 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1674771
10 September 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1673937
1 May 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1611696
2 March 2002
Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1490814
1 March 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1492089
26 February 2002
Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1489207
22 September 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1074812
10 January 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415526
20 May 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 532279
10 March 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470791
28 January 2000
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1421790
19 October 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1123224
28 September 1999
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036042
23 September 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 446015
13 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 185941
30 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 65437
30 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 218639
30 August 1999
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361085
27 July 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1105313
13 July 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1093958
13 May 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1130923
11 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426458
3 March 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470758
24 February 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1130885
19 February 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 798098
1 February 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 171692
1 February 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454628
12 January 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420057
14 September 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 517451
17 July 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1129233
3 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1126291
6 May 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 179449
3 April 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1122683
11 March 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392881
7 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 437415
3 January 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 494831
12 November 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 232032
6 October 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 537874
18 June 1997
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 778093
22 February 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 535773
17 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 37758
16 January 1997
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458369
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 30 March 2007
Resolved
The vessel's MSD has wastage on the top. The vessel is required to make permanent repairs or replace the in 30 days.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 29 May 2007
Resolution: Received Class report from ABS attesting to the installation of a new MSD system.
Engineering › Steam Boiler (propulsion) › Generating tube
Issued 18 March 2007
Resolved
Leak in the Starboard Boiler Generator Tube.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 22 January 2007
Resolved
Hydrolic pressure failure alarm sounded for 15-20 seconds while using the port steering pump.
Action required: 705 - Other - as specified
Resolved 23 January 2007
Resolution: Techs found the relief valve set to a pressure of 850. Proper pressure is 1550. Pressure was reset and and pumps tested satisfactory. ABS and Tech report faxed to marine inspector.
Engineering › Steering Gear System › Pump
Issued 16 January 2007
Resolved
Vessel reported malfunction and temporary repair of the vessel's secondary steering pump. Vessel is required to have a tug escort of adequate horsepower to maneuver the vessel in the advent of a steering loss while transiting the Houston/Galveston Captain of the Port Zone.
In addition the vessel is required to provide documentation from the certificate issuing authority attesting to the proper
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2007
Resolution: Received report attesting to proper operation of the steering pump.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 6 May 2006
Resolved
The vessel has a leak from the branch line valve to the starboard winch from the Frame Pump supply line. The vessel is required to make repairs to the satisfaction of the attend Coast Guard Inspector, prior to cargo operations
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 6 May 2006
Resolution: Recived class survey report to repairs .
Construction/Loadline › Hull › Keel
Issued 6 May 2006
Resolved
The vessel went aground in way of fore peak and portside ballast tanks. The vessel is required to provide an ABS damage survey report to the Sector Houston-Galveston OCMI, prior to departure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2006
Resolution: Received class survey that fwd peak and port ballast tanks were in satisfactory condtion.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 20 April 2006
Resolved
20APR06 - NOA RECVD AT 1512 HRS BY NVMC. VESSEL ORIGINALLY SCHEDULED TO ARRIVE AT 0230 ON THE 21ST. ISSUED COTP ORDER 49-06 RESTRICTING THE VESSEL FROM MOORING OR ANCHORING IN THE COTP ZONE UNTIL 1512 HRS ON 21APR06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 21 April 2006
Resolution: 20APR06 - NOA RECVD AT 1512 HRS BY NVMC. VESSEL ORIGINALLY SCHEDULED TO ARRIVE AT 0230 ON THE 21ST. ISSUED COTP ORDER 49-06 RESTRICTING THE VESSEL FROM MOORING OR ANCHORING IN THE COTP ZONE UNTIL 1512 HRS ON 21APR06. COTP REMOVED 21 APRIL 06.
Construction/Loadline › Hull › Side Shell
Issued 12 February 2004
Resolved
Make permanent repairs to damaged/punctured sideshell in way of #7 starboard ballast tank, frame 57.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2004
Resolved 13 February 2004
Resolution: Received ABS report attesting to satisfactory permanent repairs.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 24 March 2003
Resolved
gyro repeaters on bridge not working properly.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2003
Resolved 25 March 2003
Resolution: Rec''d from Master Marine Electronics stating gyro repeaters working properly.
Lifesaving › Buoyant Apparatus
Issued 4 October 2002
Resolved
RENEW RETRO TAPE ADN CLEAN LIFEBOUYS AS NEEDED
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 12 December 2002
Resolution: install new retro tape and clean lifebouys
Lifesaving › Lifeboat
Issued 4 October 2002
Resolved
RENEW RETRO TAPE ON TOP OF THE PORT LIFEBOAT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 12 December 2002
Resolution: install new retro tape on top of the port lifeboat
Deck/Cargo › Vapor Control Systems
Issued 4 October 2002
Resolved
MARK VAPOR CONTROL MANIFOLD IN ACCORDANCE WITH 46 CFR 39.20(b), ALL FOUR CONNECTIONS. LEGACY COMPONENT DESC: Piping/Hoses
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 12 December 2002
Resolution: all four connections are mark in accordance with 46 CFR39.20(b)
Construction/Loadline › Hull
Issued 2 March 2002
Resolved
3-4" SEAM FRACTURE IN RIVETED SIDE SHELL NEAR FRAME 54, PORT WING FUEL TANK WEEPING SMALL AMOUNT OF FUEL. TEMPORARY REPAIRS COMPLETED TO THE SATISFACTION OF THE LEAD SENIOR MARINE INSPECTOR. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Due 6 March 2002
Resolved 1 May 2002
Fire Fighting
Issued 10 January 2001
Resolved
Make permanent and proper repairs to all fire station, fire main valves to ensure that valves do not leak by when closed and permit full flow when open. Proper operation must be demonstrated to attending marine inspector or surveyor not later than 10 Feb 2001.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Fire Fighting
Issued 10 January 2001
Resolved
Label all fire pump and associated fire main press gauges to eliminate confusion with other system pressure gauges.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Engineering
Issued 10 January 2001
Resolved
Make proper corrections to the automation procedures for switching power from the emergency circuit back to the main board.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Electrical
Issued 10 January 2001
Resolved
Approved rubber matting must be installed behind main switch board.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Electrical
Issued 10 January 2001
Resolved
Approved rubber matting must be installed in front of the emergency switchboard sufficently wide enough to permit the operator to be standing on it while operating the switchboard. The present wooden deck covering is not wide enough to properly serve this function.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Electrical
Issued 10 January 2001
Resolved
Approved rubber matting must be installed behind the emergency generator switchboard.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Deck/Cargo
Issued 10 January 2001
Resolved
Make proper and permanent repairs to the emergency stop on the cargo pumps to the satisfaction of the attending marine inspector or surveyor prior to offloading cargo.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 10 January 2001
Resolved
Make proper and permanent repairs to ballast pump mechanical seal that is leaking excessively.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Electrical
Issued 10 January 2001
Resolved
Label all gauges, switches and breakers associated with the ship's service genrator operation.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Engineering
Issued 10 January 2001
Resolved
Make proper corrections to the automation procedures for the low lube oil shutdown on the ship's service generators. Parameters on the vsl's auto procedures should match the manufacturer recommendations, & should note the shut down senses pump press instead of bearing press like the alarms.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Accommodation/Occupational Safety
Issued 10 January 2001
Resolved
Repair or replace leaking deck seal on forward commode in the engineers head so that sewage is not leaking on the deck.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Engineering
Issued 10 January 2001
Resolved
Calibrate main propulsion boiler water level gauges so that all gauges thatpertain to the same drum read the same level.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Engineering
Issued 10 January 2001
Resolved
Label all gages, switches, and breakers from main propulsion boiler controlsystems to eliminate confusion.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Construction/Loadline
Issued 10 March 2000
Resolved
Repair ballast valves for #1 port upper, #1 stbd upper, #2 port upper and forepeak tanks. The remote operation gear boxes are missing.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Construction/Loadline
Issued 28 January 2000
Resolved
Repair ballast valves for #1 port upper, #1 stbd upper, #2 port upper and forepeak tanks. The remote operation gear boxes are missing.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Accommodation/Occupational Safety
Issued 28 January 2000
Resolved
Repair toilets in [name withheld], 1st Mate and Owner's staterooms.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Construction/Loadline
Issued 28 January 2000
Resolved
Renew gaskets on all engine room void's hatches.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Deck/Cargo
Issued 19 October 1999
Resolved
PROVE PROPER OPERATION OF VESSEL'S LOADING AND GAUGING COMPUTER.
Condition: Unknown
Due 16 November 1999
Resolved 19 October 1999
Engineering
Issued 30 August 1999
Resolved
PROVIDE DIVERS REPORT ON CONDITION OF RUDDER AND PROPELLER AFTER THE ALLISION WITH FREIGHT BARGE RRS 7949. VESSEL TO REMAIN AT AMA ANCHORAGE UNTIL REPORT GIVEN TO USCG. CONTACT CDO MSO NOLA TO FAX REPORT AND REQUESTCLEARANCE OF REQUIREMENT._x001C_
Condition: Unknown
Due 2 September 1999
Resolved 31 August 1999
Engineering
Issued 12 January 1999
Resolved
TEST AND PROVIDE MANUFACTURER'S STAMP FOR LP STEAM GENERATOR COIL RELIEF VALVE.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 12 January 1999
Resolved
SUBMIT BOILER AND GENERATOR AUTOMATION PROCEDURES TO LOCAL OCMI FOR APPROVAL.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Accommodation/Occupational Safety
Issued 12 January 1999
Resolved
REPLACE SEWAGE HOLDING TANK; CURRENTLY TEMPORARY REPIARS HAVE BEEN MADE.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Fire Fighting
Issued 12 January 1999
Resolved
LABEL PRESSURE SWITCHES ON CO2 SYSTEM.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Fire Fighting
Issued 12 January 1999
Resolved
REPLACE CO2 WARNING LIGHT IN HPU ROOM WITH STROBE LIGHT.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Electrical
Issued 12 January 1999
Resolved
PROPERLY DEAD END CABLE OUTSIDE CO2 ROOM OR REMOVE.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 12 January 1999
Resolved
PROVE PROPER OPERATION OF TEMPERATURE/PRESSURE ALARMS AND SHUTDOWN ON S/S AND EMER GENERATORS.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Electrical
Issued 12 January 1999
Resolved
RESTUFF STUFFING TUBES ON THE BACK SIDE OF BOTH GENERATORS.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Accommodation/Occupational Safety
Issued 12 January 1999
Resolved
PROVIDE MANUFACTURER'S DATA FOR WATER SYSTEM PRESSURE TANK.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Accommodation/Occupational Safety
Issued 12 January 1999
Resolved
MAKE PERMANENT AND PROPER REPAIRS TO VENT DUCT IN AIR COMPRESSOR ROOM.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Electrical
Issued 12 January 1999
Resolved
INSTALL DEFFUSERS ON ALL FLUORESCENT LIGHTS IN BOILER CONTROL ROOM.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 12 January 1999
Resolved
LOCATE AND CAP ALL FAMMABLE DRAIN/FILL/SAMPLING LINES WITH VALVES.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 12 January 1999
Resolved
PROVE PROPER OPERATION OF DC HEATER RELIEF VALVES. MAKE PROPER REPIARS TO FRACTURE IN ELBOW OF VENT LINE NEAR BULKHEAD.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Accommodation/Occupational Safety
Issued 12 January 1999
Resolved
PROVIDE MANUFACTURER'S DATA FOR AND PROVE PROPER OPERATION OF SAFETY RELIEFVALVE FOR NITROGEN STORAGE TANK IN IGS ROOM.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Electrical
Issued 12 January 1999
Resolved
PROPERLY TERMINATE ELECTRICAL CONNECTIONS TO HEAT LAMP IN STBD SIDE BOILER FLAT.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Accommodation/Occupational Safety
Issued 12 January 1999
Resolved
INSTALL SRCEENS ON ALL ENGINE/BOILER ROOM VENTS.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Deck/Cargo
Issued 3 June 1998
Resolved
CONDUCT PERMANENT REPAIRS AND DEMONSTRATE PROPER OPERATION OF HIGH/HIGH LEVEL ALARM FOR #1 STARBOARD CARGO TANK PRIOR TO LOADING NEXT CARGO OR_x001C_ OBTAIN COTP PERMISSION FOR ALTERNATE LOADING.
Condition: Unknown
Due 3 June 1998
Resolved 3 June 1998
Deck/Cargo
Issued 3 June 1998
Resolved
CONDUCT CARGO LOADING OPS FOR #1 STARBOARD CARGO TANK IAW AHL PROPOSAL TO COTP DATED 3JUN98. A COPY OF THIS PROPOSAL MUST BE ATTACHED TO DOI. THIS LOADING ARRANGEMENT IS VALID FOR ONE TIME ONLY BETWEEN 11-12JUN98. THIS TANK SHALL NOT BE LOADED PAST 95%, UNITL HIGH/HIGH ALARM IS REPAIRED.
Condition: Unknown
Due 3 June 1998
Resolved 3 June 1998
Engineering
Issued 11 March 1998
Resolved
O.W.S. IS NOT TO BE ALLOWED TO DISCHARGE OVERBOARD UNTIL 15 P.P.M. ALARM & SHUTDOWN IS REPAIRED. ALL DISCHARGES ARE TO BE TO ONBOARD SLOP TANKS.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998