THE SPIRIT ON THE LAKE

THE SPIRIT ON THE LAKE is a 1996 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 1996, most recently in January 2025, along with 38 deficiencies and 1 casualty investigation in 2007.

Records from 1996 to 2025. Most recent: inspection, 6 January 2025.

Built
1996
Last inspected
6 January 2025
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

446701
Flag
UNITED STATES
367122930 (licence lapsed)
Maury page id
psix-446701

Inspections, by type

…with no type recorded7
Years with a record 14 calendar years (1996–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPETERSON BOAT WORKS INC · DOUGLAS, MI, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portSHEBOYGAN, WI
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD3031MMSI 367122930 · expired · compulsorily equipped · granted 20 June 2006, cancelled 20 August 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCY4784MMSI not assigned · expired · compulsorily equipped · granted 17 June 1998, cancelled 23 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 31

6 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8058938
12 January 2021 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7123835
15 June 2008 Type not recorded
No type recorded · Station Sheboygan · USCG Great Lakes District (CGD-GL) · Activity 3237810
3 June 2008 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3207084
2 October 2007 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3071445
26 September 2007 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3066591
30 July 2007 Type not recorded
No type recorded · Station Sheboygan · USCG Great Lakes District (CGD-GL) · Activity 3013840
22 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2762047
9 July 2006 Type not recorded
No type recorded · Station Sheboygan · USCG Great Lakes District (CGD-GL) · Activity 2707506
16 June 2006 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2681708
27 April 2006 COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2587459
17 March 2006 Hull Examination
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2604112
24 August 2004 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2175160
11 August 2004 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2163260
9 August 2003 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1899680
16 May 2002 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1650785
24 April 2002 Hull Examination
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1650772
22 May 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426621
30 May 2000 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1440320
15 July 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1120187
4 June 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1410120
2 June 1998 Deficiency Check · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1404589
27 June 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1113033
6 June 1997 Initial Certification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1418173
23 April 1997 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1096551
26 February 1997 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1374875
7 February 1997 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1103964
21 November 1996 Examination of Repairs
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1087383
9 September 1996 Plan Review "T" Boat
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1177819
15 August 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1102003
28 February 1996 Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 884964

Deficiency record · 38

Lifesaving › Lifebuoys › Serviceable
Issued 3 June 2008 Resolved
Provide proper ring life buoys meeting the requirements of 46 CFR 180.70 with the required retroflective material. The vessel currently has excessively worn Retro.
Condition: Improper/Lack of Maintenance
Due 14 July 2008
Resolved 20 August 2008
Resolution: Spoke with the Master who verified the discrepancy was corrected.
Personnel › Training › Seamanship
Issued 3 June 2008 Resolved
Provide proper senior deckhand designation letter with documentation of the required training in accordance with NVIC 1-91 as listed on the vessel's in accordance with 46 CFR 185.420. Currently the senior deck hand is not adequately trained to direct all emergency procedures required by the NVIC. Due to 30 day familiarization and 30 hour helm time requirements a plan is requested by 10 June.
Condition: Improper/Lack of Maintenance
Due 10 June 2008
Resolved 12 June 2008
Resolution: Received an Email from the master [name withheld] certifying the designation letter was in place and satisfactorily outlining the planned training.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 3 June 2008 Resolved
Provide proper injector fuel supply piping free of leaks on the generator to eliminate the accumulation of fuel in the engine room bilges creating a fire hazard as required by 46 CFR 176.830.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2008
Resolution: Received an E-Mail Statement from the master of the vessel certifying the leaking fuel injector supply line had been corrected.
Engineering › Freshwater System (air cooling) › Hose
Issued 3 June 2008 Resolved
Remove or reroute the raw water hose from the air conditioner from above the electrical panel in the void aft of the engine room to protect persons and the vessel from electrical hazards IAW 46 CFR 183.200. Currently the A/C raw water supply hose touches the top of an electrical panel.
Condition: Improper Installation
Due 1 July 2008
Resolved 2 July 2008
Resolution: Attended the vessel and observed the raw water hose routed away from the electrical panel.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 3 June 2008 Resolved
Provide proper port side accommodation space window on main deck with proper safety glazing materials to dangerous fragments if broken IAW 46 CFR 177.1010. Currently the window is cracked due to engine maintenance. Required passengers not be seated in immediate area until corrected.
Condition: Damaged By Earlier Event
Due 1 July 2008
Resolved 2 July 2008
Resolution: Attended the vessel and observed the replacement window.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 3 June 2008 Resolved
Provide proper fuel vent flame screens or flame arrestors IAW 46 CFR 182.450(e). Currently the fuel tank vents have no flame screens or flame arrestors installed.
Condition: Improper/Lack of Maintenance
Due 1 July 2008
Resolved 2 July 2008
Resolution: Attended the vessel and observed proper flame srceens held in place with hose clamps over the vents.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 3 June 2008 Resolved
Provide proper name of vessel marking on Bow IAW 46 CFR 67.123.
Condition: Improper Installation
Due 14 July 2008
Resolved 20 August 2008
Resolution: Spoke with the Master who verified the discrepancy was corrected.
Engineering › Fuel Oil Service System › Valve
Issued 22 August 2006 Resolved
Trouble shoot, make repairs and demonstrate proper operation of the vessel's main diesel engine prior to carrying passengers to the satisfaction of a marine inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2006
Resolved 23 August 2006
Resolution: The problem was the result of operator error. They switched fuel tank suction to another tank without closing the original tank suction. This caused the engine fuel system to become air bound. The verbal CG-835 was rescinded.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 17 March 2006 Resolved
The shaft bearing showed signs of heavy cracking due to being exposed to the elements.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 April 2006
Resolution: Replaced bearings
Engineering › Steering Gear System › Rudder Bearing
Issued 17 March 2006 Resolved
Bearing showed signs of excessive cracking due to exposure to the elements.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 April 2006
Resolution: Replaced bearing.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2006 Resolved
Electrical wiring on Port side engine room are supported by plastic wire ties need to be replaced with metal wire hangers.
Action required: 705 - Other - as specified
Resolved 27 April 2006
Resolution: All wiring in engine room overhead supported by metal wire ties.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 August 2004 Resolved
Vessel's COI was not onboard.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2005
Resolved 24 August 2004
Resolution: Owner provided via mail curent COI.
Documentation › Certificates/Documents › Stability Letter
Issued 11 August 2004 Resolved
Stability Letter was not onboard.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2004
Resolution: Owner provided via mail original Stabilty Letter.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 August 2004 Resolved
Certificate of Documentation was not onboard.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Removed this item as COI has expired. Requirement has been addressed as a work list item and will be resolved prior to a COI being issued.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 August 2004 Resolved
Prove crew is enrolled in the DAPI program.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: New owner is in the process of enrolling employees in a DAPI monitoring program. This requirement has been addressed as a worklist item and will be resolved prior to a COI being issued.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 11 August 2004 Resolved
Prove crew is current in First Aid and CPR qualifications.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Examined current first aid and CPR cards for all crew attending the COI exam.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 August 2004 Resolved
Proved proper operation of vessel's radar system.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Witnessed radar operating satisfactory during COI exam.
Personnel › Training › Familiarization Training
Issued 11 August 2004 Resolved
Conduct underway drills.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Witnessed fire, man overboard and emergency steering drill during COI exam.
Lifesaving › Hand Flares › Expired
Issued 11 August 2004 Resolved
Replace flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Counted 6 red hand flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 August 2004 Resolved
Replace eyewash and asprin in vessel's first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Examined fully stocked first aid kit.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 11 August 2004 Resolved
Prove proper operation of MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Witnessed successful operation of main propulsion unit. Controls from both flying bridge and main operating station. Shaft seal was adequate.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 8 September 2003 Resolved
Annual test of Fixed CO2 Fire Extinguishing System not completed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Verified servicing certificates from Fire Protection Company of Kalamazoo, Michigan.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 September 2003 Resolved
Annual testing of portable fire fighting extinguisher not completed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Verified servicing certificates from Fire Protection Company of Kalamazoo, Michigan.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 September 2003 Resolved
Battery boxes need to be permently mounted to battery tray.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Examined battery installations and found to be secure in trays.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 September 2003 Resolved
Ring bouy waterlight inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Examined properly functioning float light during COI exam.
Fire Fighting › Combustible Materials › Ceilings
Issued 8 September 2003 Resolved
Sound deadner on engine room hatch has a questionable fire rating. O/O to provide fire rating to the OCMI
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 27 April 2006
Resolution: New owner removed insulation that prior owner had installed on engine room overhead in way of hatch. Prior owner had installed to reduce engine room noise in the main cabin.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 September 2003 Resolved
Unable to account for Lifejackets reflecting total count of 52 persons allowed.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 27 April 2006
Resolution: 52 adult jackets and 12 child jackets were counted during the COI exam.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 September 2003 Resolved
Pilothouse flashlight inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 April 2006
Resolution: Witnessed successful operation of two hand held flashlights on board.
Documentation
Issued 4 June 1999 Resolved
CONDUCT AND LOG THE FCC GREAT LAKES AGREEMENT INSPECTION.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Construction/Loadline
Issued 4 June 1999 Resolved
PROVIDE A BILGE HIGH LEVEL ALARM IN THE AFT COMPARTMENT.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Electrical
Issued 2 June 1998 Resolved
DETERMINE SOURCE OF UNUSED WIRES/CABLE IN THE FOREPEAK AND PROVIDE STAUS TOMSD GRAND HAVEN.
Condition: Unknown
Due 1 July 1998
Resolved 21 July 1998
Navigation
Issued 2 June 1998 Resolved
PROVE OPERATION OF THE BRIDGE COMPASS LIGHT.
Condition: Unknown
Due 1 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 2 June 1998 Resolved
PROVIDE 3 FIRE BUCKETS IAW 46 CFR 181.610, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 1 July 1998
Resolved 21 July 1998
Construction/Loadline
Issued 6 June 1997 Resolved
Install automatic bilge pump visual indicators at bilge pump power switchesin pilot house.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Fire Fighting
Issued 6 June 1997 Resolved
Install fire dampers for port and starboard engine room ventilation ducts with open/closed indicators to replace temporary vent covers.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Electrical
Issued 6 June 1997 Resolved
Install ammeter for generator at operating station.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Navigation
Issued 6 June 1997 Resolved
Procure current light list, rules of the road, 46CFR166-199.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Construction/Loadline
Issued 6 June 1997 Resolved
Install high water level audible and visual bilge alarms for the engine_x001C_ room, bow thruster and air conditioning compartments.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997

Casualty record · 1

2 October 2007Routine · role: Involved in a Marine Casualty · activity 3071445
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.