← All vessels
THE SPIRIT ON THE LAKE
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Great Lakes District (CGD-GL) · Other hulls named THE SPIRIT ON THE LAKE
THE SPIRIT ON THE LAKE is a 1996 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 1996, most recently in January 2025, along with 38 deficiencies and 1 casualty investigation in 2007.
Records from 1996 to 2025. Most recent: inspection, 6 January 2025.
- Built
- 1996
- Last inspected
- 6 January 2025
- Documentation
- No Operation - PM · documentation file of 10 September 2026
- Deficiencies
- 38 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2007
Identity
1046749
446701
Flag
UNITED STATES
367122930 (licence lapsed)
Maury page id
psix-446701
Inspections, by type
…with no type recorded7
Years with a record
14 calendar years (1996–2025)
The 31 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPETERSON BOAT WORKS INC · DOUGLAS, MI, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portSHEBOYGAN, WI
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD3031MMSI 367122930 · expired · compulsorily equipped · granted 20 June 2006, cancelled 20 August 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCY4784MMSI not assigned · expired · compulsorily equipped · granted 17 June 1998, cancelled 23 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 31
6 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8058938
12 January 2021
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7123835
15 June 2008
Type not recorded
No type recorded · Station Sheboygan · USCG Great Lakes District (CGD-GL) · Activity 3237810
3 June 2008
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3207084
2 October 2007
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3071445
26 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3066591
30 July 2007
Type not recorded
No type recorded · Station Sheboygan · USCG Great Lakes District (CGD-GL) · Activity 3013840
22 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2762047
9 July 2006
Type not recorded
No type recorded · Station Sheboygan · USCG Great Lakes District (CGD-GL) · Activity 2707506
16 June 2006
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2681708
27 April 2006
COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2587459
17 March 2006
Hull Examination
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2604112
24 August 2004
Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2175160
11 August 2004
Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2163260
9 August 2003
Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1899680
16 May 2002
Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1650785
24 April 2002
Hull Examination
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1650772
22 May 2001
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426621
30 May 2000
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1440320
15 July 1999
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1120187
4 June 1999
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1410120
2 June 1998
Deficiency Check · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1404589
27 June 1997
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1113033
6 June 1997
Initial Certification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1418173
23 April 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1096551
26 February 1997
Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1374875
7 February 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1103964
21 November 1996
Examination of Repairs
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1087383
9 September 1996
Plan Review "T" Boat
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1177819
15 August 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1102003
28 February 1996
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 884964
Deficiency record · 38
Lifesaving › Lifebuoys › Serviceable
Issued 3 June 2008
Resolved
Provide proper ring life buoys meeting the requirements of 46 CFR 180.70 with the required retroflective material. The vessel currently has excessively worn Retro.
Personnel › Training › Seamanship
Issued 3 June 2008
Resolved
Provide proper senior deckhand designation letter with documentation of the required training in accordance with NVIC 1-91 as listed on the vessel's in accordance with 46 CFR 185.420. Currently the senior deck hand is not adequately trained to direct all emergency procedures required by the NVIC. Due to 30 day familiarization and 30 hour helm time requirements a plan is requested by 10 June.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 3 June 2008
Resolved
Provide proper injector fuel supply piping free of leaks on the generator to eliminate the accumulation of fuel in the engine room bilges creating a fire hazard as required by 46 CFR 176.830.
Engineering › Freshwater System (air cooling) › Hose
Issued 3 June 2008
Resolved
Remove or reroute the raw water hose from the air conditioner from above the electrical panel in the void aft of the engine room to protect persons and the vessel from electrical hazards IAW 46 CFR 183.200. Currently the A/C raw water supply hose touches the top of an electrical panel.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 3 June 2008
Resolved
Provide proper port side accommodation space window on main deck with proper safety glazing materials to dangerous fragments if broken IAW 46 CFR 177.1010. Currently the window is cracked due to engine maintenance. Required passengers not be seated in immediate area until corrected.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 3 June 2008
Resolved
Provide proper fuel vent flame screens or flame arrestors IAW 46 CFR 182.450(e). Currently the fuel tank vents have no flame screens or flame arrestors installed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 3 June 2008
Resolved
Provide proper name of vessel marking on Bow IAW 46 CFR 67.123.
Engineering › Fuel Oil Service System › Valve
Issued 22 August 2006
Resolved
Trouble shoot, make repairs and demonstrate proper operation of the vessel's main diesel engine prior to carrying passengers to the satisfaction of a marine inspector.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 17 March 2006
Resolved
The shaft bearing showed signs of heavy cracking due to being exposed to the elements.
Engineering › Steering Gear System › Rudder Bearing
Issued 17 March 2006
Resolved
Bearing showed signs of excessive cracking due to exposure to the elements.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2006
Resolved
Electrical wiring on Port side engine room are supported by plastic wire ties need to be replaced with metal wire hangers.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 August 2004
Resolved
Vessel's COI was not onboard.
Documentation › Certificates/Documents › Stability Letter
Issued 11 August 2004
Resolved
Stability Letter was not onboard.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 August 2004
Resolved
Certificate of Documentation was not onboard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 August 2004
Resolved
Prove crew is enrolled in the DAPI program.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 11 August 2004
Resolved
Prove crew is current in First Aid and CPR qualifications.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 August 2004
Resolved
Proved proper operation of vessel's radar system.
Personnel › Training › Familiarization Training
Issued 11 August 2004
Resolved
Conduct underway drills.
Lifesaving › Hand Flares › Expired
Issued 11 August 2004
Resolved
Replace flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 August 2004
Resolved
Replace eyewash and asprin in vessel's first aid kit.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 11 August 2004
Resolved
Prove proper operation of MDE.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 8 September 2003
Resolved
Annual test of Fixed CO2 Fire Extinguishing System not completed
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 September 2003
Resolved
Annual testing of portable fire fighting extinguisher not completed
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 September 2003
Resolved
Battery boxes need to be permently mounted to battery tray.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 September 2003
Resolved
Ring bouy waterlight inoperable.
Fire Fighting › Combustible Materials › Ceilings
Issued 8 September 2003
Resolved
Sound deadner on engine room hatch has a questionable fire rating. O/O to provide fire rating to the OCMI
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 September 2003
Resolved
Unable to account for Lifejackets reflecting total count of 52 persons allowed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 September 2003
Resolved
Pilothouse flashlight inoperable.
Documentation
Issued 4 June 1999
Resolved
CONDUCT AND LOG THE FCC GREAT LAKES AGREEMENT INSPECTION.
Construction/Loadline
Issued 4 June 1999
Resolved
PROVIDE A BILGE HIGH LEVEL ALARM IN THE AFT COMPARTMENT.
Electrical
Issued 2 June 1998
Resolved
DETERMINE SOURCE OF UNUSED WIRES/CABLE IN THE FOREPEAK AND PROVIDE STAUS TOMSD GRAND HAVEN.
Navigation
Issued 2 June 1998
Resolved
PROVE OPERATION OF THE BRIDGE COMPASS LIGHT.
Fire Fighting
Issued 2 June 1998
Resolved
PROVIDE 3 FIRE BUCKETS IAW 46 CFR 181.610, PRIOR TO OPERATING WITH PASSENGERS.
Construction/Loadline
Issued 6 June 1997
Resolved
Install automatic bilge pump visual indicators at bilge pump power switchesin pilot house.
Fire Fighting
Issued 6 June 1997
Resolved
Install fire dampers for port and starboard engine room ventilation ducts with open/closed indicators to replace temporary vent covers.
Electrical
Issued 6 June 1997
Resolved
Install ammeter for generator at operating station.
Navigation
Issued 6 June 1997
Resolved
Procure current light list, rules of the road, 46CFR166-199.
Construction/Loadline
Issued 6 June 1997
Resolved
Install high water level audible and visual bilge alarms for the engine_x001C_ room, bow thruster and air conditioning compartments.
Casualty record · 1
2 October 2007Routine · role: Involved in a Marine Casualty · activity 3071445
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.