Records from 1985 to 1995. Most recent: inspection, 2 May 1995.
Documentation record
Registered dimensions (L × B × D)41.4 ft × 13.6 ft × 2.5 ft
Registered tonnagegross 15 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALVIN BEAL & SON · BEALS ISLAND, ME, UNITED STATES · built 1964
Hull materialWood
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 18 August 1989 · expires 31 August 1995
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
2 May 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1178212
1 July 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1271025
25 September 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1244500
16 May 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 910467
24 May 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 921261
17 May 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1241771
7 June 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1197004
4 June 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1040152
23 June 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 894787
22 May 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1333990
15 July 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1296795
23 May 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 982984
Construction/Loadline
Issued 17 May 1990
Resolved
FOUR PLANKS RENEWED. (1) STRAKE TWELVE 9'9"X5"X1 1/4 AFT PLANK. FASTENERS CHECKED. (2) STRAKE TWELVE 6' FORWARD OF ABOVE PLANK. (3) STRAKE THIRTEEN MID-BODY 11'X5"X1 1/4 (4) STRAKE FOURTEEN MID-BODY 8'6"X5X1 1/4
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 4 June 1989
Resolved
VESSEL'S BATTERY WAS NOT IN THE REQUIRED ACID RESISTANT TRAY AND WAS NOT SECURED TO PREVENT MOVEMENT.
Condition: Unknown
Due 4 June 1989
Resolved 4 June 1989
Engineering
Issued 4 June 1989
Resolved
NEW FUEL SHUT OFF VALVES WERE INSTALLED AND DO NOT CONNECT TO THE REMOTE FUEL SHUT OFF VALVES.
Condition: Unknown
Due 4 June 1989
Resolved 4 June 1989
Lifesaving
Issued 4 June 1989
Resolved
ONE CHILD'S TYPE PFD WAS MISSING.
Condition: Unknown
Due 4 June 1989
Resolved 4 June 1989
Construction/Loadline
Issued 15 July 1986
Resolved
RESECURE HANGER ON AFT END OF KEEL COOLER.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
MAKE THAT PORTION OF THE PORT SIDE IN WAY OF THE DECK AND SHEER STRAKE ACCESSIBLE FOR INSPECTION OF PORT FRAMES IN THAT AREA. NOTE-RIBS IN THE AREA NOT ACCESSIBLE ,THOSE THAT ARE HAVE EXCESSIVE ROT.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
OPEN SEA VALVES FOR EXAMINATION.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
INSTALL SHEAR CLAMP AND SHELF IN WAY OF NEW FRAMES ON BOTH SIDES.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
RENEW IN KIND ALL BENT OAK FRAMES ON PORT AND STARBOARD SIDES FROM AFTER END OF DECKHOUSE TO TRANSOM; 14 FRAMES EACH SIDE.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
INSTALL NEW DECK BEAM AND DECKING FROM END OF DECKHOUSE TO TRANSOM.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Engineering
Issued 15 July 1986
Resolved
REPLACE THE VESSELS CUTLASS BEARING WITH BEARING OF SUITABLE SIZE.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
REFASTEN ALL RUB RAILS STARBOARD SIDE.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
RENEW ROTTED AND BROKEN PORTIONS OF PORT GUNWALE.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
REFASTEN PORT RAIL.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Construction/Loadline
Issued 15 July 1986
Resolved
MAKE COMPARTMENT FORWARD OF COLLISSION BULKHEAD ACCESSIBLE TO MARINE INSPECTOR.
Condition: Unknown
Due 15 July 1986