Records from 2016 to 2018. Most recent: operational control imposed, 13 April 2018.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 April 2018
No resolution recorded
Owner/ Operator of [name withheld] submitted vessel to dry dock examination on 30 April, 2017 per the vessel's dry dock schedule. Multiple work-list items have been issued, however, the vessel has not completed a credit dry dock examination. 46CFR176.700
Action required: 30 - Ship detained
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 April 2018
No resolution recorded
oast Guard Marine Inspectors attended vessel on 18 July 2017 to conduct Annual Inspection as required by Certificate of Inspection and regulation. Vessel has not completed Annual Inspection. Certificate of Inspection has lapsed in validity and will be removed from the [name withheld]. 46CFR176.404(a)
Action required: 30 - Ship detained
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2018
No resolution recorded
In forepeak - remove all coatings on internal planks as identified, 3 feet out from stem on both sides, from keel to rub rail, to evaluate condition of fasteners. Clean out all seam sealer material in forepeak in way of the stem where sealer appears to be pushing the planks away from frame and stem, indicating popped fasteners.
Submit repair proposal based on findings. All repair proposals to the hull must be approved by the Coast Guard PRIOR to any repairs being initiated. 46CFR176.700
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 April 2018
No resolution recorded
Once repairs in deficiency #3 are completed, conduct underway assessment to ensure watertight integrity of forepeak for completion of credit dry dock. If credit dry dock is completed to the satisfaction of the OCMI, the [name withheld] will be placed on a one year credit dry dock cycle.
Action required: 30 - Ship detained
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 April 2018
No resolution recorded
Due to length of on-going Annual inspection and dry dock examination, an inspection for renewal of a COI must be conducted to determine if the vessel is in satisfactory condition and fit for route and service.
Action required: 30 - Ship detained
Electrical › Lighting (service) › Lighting Fixture
Issued 7 November 2017
Resolved
Place guard on light fixture in fuel tank space overhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 November 2017
Resolved
Label breaker panel in port side closet of forward accommodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 November 2017
Resolved
Post emergency instructions in bridge for fire, heavy weather, and man overboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 7 November 2017
Resolved
Provide original FCC Station License. Route restricted to w/i 1000 ft from shore.
Action required: 705 - Other - as specified
Resolved 31 January 2018
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 7 November 2017
Resolved
Label all PFD's IAW Subchapter T Requirements.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 November 2017
Resolved
Post PFD donning placard for Kapok PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 November 2017
No resolution recorded
Replace 01 Child size PFD and 13 adult size PFDs. Passenger count restricted to 49 (6 child).
Action required: 705 - Other - as specified
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 November 2017
Resolved
Remove flammable materials from engine room including but not limited to aerosol cans
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 November 2017
Resolved
Remove all dead end wires from engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 7 November 2017
No resolution recorded
Clean Racor filter on port side MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 7 November 2017
No resolution recorded
Attach water lights & paddles to all Lifefloats and Buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 7 November 2017
No resolution recorded
Replace retroreflective material on all survival craft.
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Buoyant Apparatus › Painter
Issued 7 November 2017
No resolution recorded
Arrange Survival craft IAW Subchapter T requirements.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Not Operational
Issued 7 November 2017
Resolved
Repair forward void bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 November 2017
Resolved
Install batteries and charger IAW Subchapter T requirements.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2018
Engineering › Bilge Water Management System › Strainer
Issued 7 November 2017
No resolution recorded
Remove oil and paint chips from Engine room bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 May 2017
Resolved
Vessel is to receive credit drydock inspection and ISE prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 30 May 2017
Resolution: Vessel began DD/ISE inspection.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 12 August 2016
No resolution recorded
CC01- Provide engine tech report for port and stbd main engines. To be provided by an authorized engine manufacture tech. Due next annual inspection (apr2017).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017 — due date passed with no resolution recorded
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 12 August 2016
No resolution recorded
CC02- Prove proper operation of the engine room fire detection panel and conduct training with crew on proper operation. Properly label panel. Due next annual inspection (apr2017).
Action required: 705 - Other - as specified
Due 30 April 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Cable
Issued 12 August 2016
Resolved
CC03- Provide electrical plans for A/C system in the pilot house for approval.
Condition: Improper Installation
Due 12 September 2016
Resolved 4 October 2016
Resolution: Owner removed AC in pilot house.
Engineering › Bilge Water Management System › Manifold
Issued 12 August 2016
Resolved
CC04- Renew all rusted valve handles on the bilge manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 4 October 2016
Resolution: All valve handles replaced.
Construction/Loadline › Penetrations › Valve Flange
Issued 12 August 2016
Resolved
CC05- Valve handle to sinks (thruhull fitting) is missing. Provide valve handle.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Valve handle installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 12 August 2016
Resolved
CC06- Properly attach shift (fwd-reverse) cable to the gearbox. Due next annual inspection (apr2017).
Condition: Placed in Improper Service
Due 30 April 2017
Resolved 7 November 2017
Resolution: Attached shift cable, witnessed proper operation.
Engineering › Fuel Oil Service System › Filter
Issued 29 July 2016
Resolved
The port raycor fuel filter is leaking excessivly. Vessel must make proper repairs. 46CFR176.830(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Raycor filters cleaned /repaired.
Engineering › Fuel Oil Service System › Hose
Issued 29 July 2016
Resolved
The port MDE fuel line is bundled in the wire run. Vessel must remove this fuel line from the wiring. 46CFR176.830(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Fuel line seperate and properly mounted.
Operations/Management › Vessel Activity › Underway
Issued 29 July 2016
Resolved
Vessel was unable to prove proper operation of the starboard MDE. Vessel must prove proper operation. 46CFR176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Conducted sea trials for aprox 1 hour running full speed.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 29 July 2016
Resolved
Vessel must remove all oily water and fuel from its bilges in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: All oil and water removed.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 July 2016
Resolved
Vessel has numerous dead end wires & unauthorized wire connections throughout the engineroom. Vessel must remove all dead end wires or make safe in a junction box. All unauthorized connections must be completed the correct way.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Wires removed/corrected.
Engineering › Fuel Oil Service System › Hose
Issued 29 July 2016
Resolved
The fuel lines for the port MDE & generator are not J1942 approved. Vessel must replace non-J1942 hose with approved type and fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Hoses are SAT.
Communications › Radio Communications › VHF Radiotelephone
Issued 16 March 2016
Resolved
Porperly install and provide proper operation of radio. Limited vessel to 1,000 ft from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Radio tested and operational
Lifesaving › Lifefloat › Serviceable
Issued 16 March 2016
Resolved
Repair or replace damaged lifefloat.
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Lifefloat was replaced.
Lifesaving › Inflatable Liferafts › Painter
Issued 16 March 2016
Resolved
Properly install painter line to weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Pianter line was properly installed to the weak link.
Communications › Public Address System › Loudspeaker
Issued 16 March 2016
Resolved
Properly install public address system and provide proper operation.
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Proper installation of public address system was installed.
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 March 2016
Resolved
Properly attach bonding in lazarette.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Bonding in lazarette was properly attached.
Engineering › Bilge Water Management System › Hose
Issued 16 March 2016
Resolved
Double hose clamp on exhaust hose in #4 compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 August 2016
Resolution: All hoses double clamped.
Engineering › Bilge Water Management System › Pump
Issued 16 March 2016
Resolved
Properly install overboard valve for electric bilge pump in #4 compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Overboard valve was installed.
Engineering › Bilge Water Management System › Pump
Issued 16 March 2016
Resolved
Properly tighten fixed bilge pump belt on MDE, provide proper operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Proper operation was provided for bilge pump belt on MDE, and belt was tightened.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 16 March 2016
Resolved
Remove all oil from oil filter drip pans.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Oil filter drip pans were cleaned and excess oil was removed.
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 16 March 2016
Resolved
Identify and repair oil leak on port MDE.
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Oil leak on port MDE was repaired.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 March 2016
Resolved
Replace 16 adult life jackets.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: Owner replaced 16 adult life jackets.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 16 March 2016
Resolved
Port side bridge window has less than 70% visability.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 January 2018
Resolution: Replaced window.