MAURY USCG vessel records Sign in
← All vessels

ZEPHYR

ZEPHYR is a 1964 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1985, most recently in February 2009, along with 142 deficiencies — 5 with no resolution recorded — and 2 casualty investigations in 2009.

Records from 1985 to 2009. Most recent: casualty investigation, 22 August 2009.

Built
1964
Last inspected
17 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD8526
Flag
UNITED STATES
366891250, 367106280, 367299310 (licence lapsed)
Maury page id
psix-44676

Inspections, by type

…with no type recorded8
…past their stated due date2
Years with a record 17 calendar years (1985–2009)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD8526MMSI 367299310 · expired · compulsorily equipped · granted 26 June 2007, cancelled 26 August 2017
WDC9752MMSI 367106280 · expired · compulsorily equipped · granted 12 April 2006, cancelled 18 June 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDB3785MMSI 366891250 · cancelled · compulsorily equipped · granted 25 April 2003, cancelled 17 March 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCY4568MMSI not assigned · expired · compulsorily equipped · granted 11 June 1998, cancelled 16 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

17 February 2009 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3418766
4 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3412264
12 September 2008 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3323277
2 September 2008 Examination of Repairs · Internal Structural Exam · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3316088
2 September 2008 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3322545
19 June 2008 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3241313
15 June 2008 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3238564
18 July 2007 Damage Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3089219
6 June 2007 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2952052
3 May 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2913816
22 March 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2892867
29 April 2006 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2636414
16 February 2005 Hull Examination · Annual Inspection · MARPOL Annex V Examination · Internal Structural Exam · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2294009
1 March 2004 MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2015441
3 April 2003 Deficiency Check · Hull Examination · MARPOL Annex V Examination · Annual Inspection · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1767404
24 June 2002 Deficiency Check · Administrative Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1635655
30 May 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1622521
8 May 2002 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1614023
14 May 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1420518
26 May 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1417068
24 May 2000 Hull Examination · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1417067
7 May 1999 Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1384170
4 June 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1464104
14 May 1998 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1468451
15 May 1990 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 922507
27 June 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1205063
6 June 1988 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1198706
3 June 1988 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1195903
7 July 1987 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1011592
30 June 1987 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1317319
20 June 1986 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1018875
9 June 1986 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 985224
9 April 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 981381
26 March 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1288703

Deficiency record · 142

Construction/Loadline › Hull › Sheerstrake
Issued 10 August 2009 Resolved
Make repairs to leaking bullwarks, superstructure, and anywhere rain water can leak into vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2009
Resolution: Leaks to vessel repaired.
Engineering › Reduction Gearing/Clutches › Line Shaft
Issued 10 August 2009 Resolved
Make permanent repairs to port main engine/reduction gear
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2009
Resolution: Port engine/reduction gear working properly.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 August 2009 Resolved
Make permanent repairs to engine room hatch cover to make air tight. Submit drawings/plans to MSD Coram for approval prior to commencing repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2009
Resolution: ngine room hatch is air tight.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 August 2009 Resolved
Thoroughly clean all bilges of dirt and oil and dispose of IAW local, state, and federal regulations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2009
Resolution: Bilges clean of oil and sorbent pads in place.
Communications › Radio Communications › EPIRB
Issued 17 February 2009 No resolution recorded
Renew EPIRB registration prior to sailing beyond 3nm from baseline
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 17 October 2008 Resolved
Make MSD system operable and secure overboard discharge valve in the closed position. Vessel is restricted to short runs of 30 minutes or less until corrected.
Due 24 October 2008
Resolved 24 October 2008
Resolution: Made MSD system operable and secured overboard discharge valve in the closed position.
Engineering › Fuel Oil Service System › Hose
Issued 17 October 2008 Resolved
Renew starboard main engine fuel return line from engine to tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2008
Resolved 24 October 2008
Resolution: Renewed starboard main engine fuel return line from engine to tank.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 17 October 2008 Resolved
While attempting to start starboard MDE starting circuit at starter and at switch began smoking heavily after only a few seconds of turning engine over.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2008
Resolution: Problem was resolved by cleaning connections and properly reconnecting.
Engineering › Fuel Oil Service System › Piping
Issued 17 October 2008 Resolved
STBD main engine has difficulty starting and fuel supply line drains empty.
Due 24 October 2008
Resolved 17 October 2008
Lifesaving › Lifefloat › Not on Board
Issued 11 October 2008 No resolution recorded
Vessel is limited to within three miles from shore (no primary lifesaving, with EPIRB) through 31 October 08. On 1 Nov 2008 (cold water in IAW NVIC 7-91) vessel will be limited to a lakes, bays, and sounds route, no further than 1 mile from shore. This is IAW table 180.220 (c) in 46 CFR part 180, and will remain in effect until primary lifesaving is repaired or replaced.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 October 2008 Resolved
Vessel must be hauled out for full drydock inspection and proper repair of damage to stbd stern/transom and both stern tubes. This is not in conjuction with vessels normal hull exam due date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2009
Resolved 17 February 2009
Resolution: Vessel was hauled out and began its hull exam/damage repairs on this date.
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 11 October 2008 Resolved
Vessels head must be configured to all applicable regulations, specifically regarding space between toilet and door, ability to lock door, running water for hand washing etc..
Due 11 January 2009
Resolved 6 May 2009
Resolution: Necessary repairs made to head.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 11 October 2008 Resolved
Repair/replace all engine gauges IAW 46 CFR 182.410(b)
Due 11 January 2009
Resolved 6 May 2009
Resolution: Engine gauges now operate properly.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 11 October 2008 Resolved
Replace bolts on both main engine water pump discharge and suction flanges
Due 11 January 2009
Resolved 6 May 2009
Resolution: Required bolts were replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 October 2008 Resolved
fabricate brackets to support stbd main engine r/w pipe.
Due 11 January 2009
Resolved 6 May 2009
Resolution: Proper support brackets installed on r/w system.
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 11 October 2008 Resolved
Permanently mount all sewage equipment in a manner that allows routine inspection.
Due 11 January 2009
Resolved 6 May 2009
Resolution: Configuration of sewage equipment acceptable.
Engineering › Lubricating Oil Service System › Hose
Issued 11 October 2008 No resolution recorded
Permanently route port MDE lube oil hoses away from shaft coupling.
Due 30 November 2009 — due date passed with no resolution recorded
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 11 October 2008 Resolved
Replace deteriorated jacketwater hoses on stbd MDE as discussed (realign piping).
Due 11 January 2009
Resolved 6 May 2009
Resolution: Necessary water hoses were replaced.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 October 2008 Resolved
Make forward engine room bulkhead water tight and air tight as discussed
Due 11 January 2009
Resolved 6 May 2009
Resolution: Fwd engine room bulkhead is now water and air tight.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 October 2008 Resolved
Repair Transom door/railing
Due 11 January 2009
Resolved 6 May 2009
Resolution: Necessary repairs made.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 September 2008 Resolved
Prove proper operation of Bilge high water alarms in each compartment (audible and visible) at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2008
Resolution: Proved proper operation of Bilge high water alarms in each compartment (audible and visible) at operating station
Engineering › Bilge Water Management System › Not Operational
Issued 19 September 2008 Resolved
Prove proper operation of all bilge systems on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2008
Resolution: Proved proper operation of all bilge systems on vessel.
Communications › Radio Communications › EPIRB
Issued 19 September 2008 Resolved
Properly mount EPIRB in float free arrangment and provide new hydrostatic release for EPIRB arrangment or provide proof via receipt that hydrostatic release is still valid.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2008
Resolution: Properly mounted EPIRB in float free arrangment and provided new hydrostatic release for EPIRB arrangment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 September 2008 No resolution recorded
Insulate all bare connectors and clean up/consolidate all loose wiring on vessel.
Due 30 November 2009 — due date passed with no resolution recorded
Lifesaving › Lifefloat › Serviceable
Issued 19 September 2008 Resolved
Vessel may not operate in cold water beyond one mile from shore until unserviceable lifefloats are replaced with new ones. Each new lifefloat must have a coast guard approved waterlight attached to it with at least 18 ft of floatable line. Each waterlight must have a mounting bracket.
Action required: 705 - Other - as specified
Resolved 6 May 2009
Resolution: Operating limitations listed in different def which is still open. Vessel now has approved waterlight, floatable line and mounting bracket.
Lifesaving › Lifefloat › Netting
Issued 19 September 2008 Resolved
Lifefloat arrangement may not be used for storage of any equipment or debris other than two paddles of at least 4ft in length which must be stored and secured within each lifefloat. Vessels name should be stenciled to each paddle.
Action required: 705 - Other - as specified
Resolved 6 May 2009
Resolution: Lifefloat arrangements are now satisfactory.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 September 2008 Resolved
Properly mount all portable fire extinguishers with brackets secured to the bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2008
Resolution: Properly mounted all portable fire extinguishers with brackets and secured them to the bulkhead.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 September 2008 Resolved
waterlight on lifering must be attached with 3 to 6 feet of floatable line with the bitter end attached to the lifering via a detachable clip
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2008
Resolution: waterlight on lifering has been attached with 3 to 6 feet of floatable line with the bitter end attached to the lifering via a detachable clip.
Lifesaving › Lifefloat › Float-free Link
Issued 19 September 2008 Resolved
New lifefloat arrangement must have an approved weak link for correct size and be attached to a painter of at least 110ft in a properly coiled arrangement. Floatable line must be used for the painter.
Action required: 705 - Other - as specified
Resolved 6 May 2009
Resolution: Lifefloat is now properly attached with approved weak link and painter.
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 19 September 2008 Resolved
Replace both main engine fuel system suction and return hoses as discussed and submit a repair proposal for the existing temporary repair at the stbd suction connection
Action required: 705 - Other - as specified
Resolved 11 October 2008
Resolution: Replaced both main engine fuel system suction and return hoses using copper piping as discussed and submited a repair proposal for the existing temporary repair at the stbd suction connection.
Engineering › Bilge Water Management System › Piping
Issued 19 September 2008 No resolution recorded
Replace missing bilge suction pipe in compartment #2 using 1 inch diameter pipe and suction strainer. Install reach rod handles for bilge suction valves in a more permanent fashion. (label reach rods in pilothouse).
Action required: 701 - Prior to carriage of passengers/cargo
Resolution: Replaced missing bilge suction pipe in compartment #2 using 1 inch diameter pipe and suction strainer. Installed reach rod handles for bilge suction valves in a more permanent fashion. (labeled reach rods in pilothouse).
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 19 September 2008 Resolved
Clean all equipment, debris, garbage, and oily water mixtures from the bilges.
Action required: 705 - Other - as specified
Resolved 11 October 2008
Resolution: Cleaned all equipment, debris, garbage, and oily water mixtures from the bilges.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 September 2008 Resolved
Make permanent repairs to port MDE raw water suction valve and replace suction hoses to both main engine cooling pumps, and replace the two oversized hoses on the discharge side of stbd raw water cooling pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2008
Resolution: Made permanent repairs to port MDE raw water suction valve and replaced suction hoses to both main engine cooling pumps, and replaced the two oversized hoses on the discharge side of stbd raw water cooling pump.
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 September 2008 Resolved
Repair Hydraulic steering system to ensure no leaking oil. Ensure use of proper hoses and fittings and present specs on materials to CG marine inspector prior to installation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2008
Resolution: Repaired Hydraulic steering system to ensure no leaking oil. Used proper hoses and fittings in accordance with CG regulations.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 September 2008 Resolved
Prove servicing of all portable and fixed fire extinguishing systems. Demonstrate proper operation of fire detection system and automatic engine shutdowns connected to fixed fire fighting system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2008
Resolution: Proved servicing of all portable and fixed fire extinguishing systems. Demonstrated proper operation of fire detection system and automatic engine shutdowns connected to fixed fire fighting system
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 29 October 2007 Resolved
Recondition or renew port propeller.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 October 2007
Resolved 29 October 2007
Resolution: Prop reconditioned. Bent blade repaired.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 18 July 2007 Resolved
Repair leak IWO Stbd shaft intermediate strut. Bolts holding strut to hull planking and framing found loose and leaking.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 19 July 2007
Resolution: New fastenings, galvanized steel bolts, installed to replace the worn and loose existing bolts. Diver fitted new bolts w/ underwater caulk. Strut secure & leaking stopped.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 18 July 2007 Resolved
Remove and clean MDE starters. Salt water entered drive and motor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 31 July 2007
Resolution: Starters replaced with remanufactured units by repair shop. Port engine solenoid renewed.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 July 2007 Resolved
Clean corrosion off battery cables & replace worn out clamps at battery connections.
Condition: Unknown
Due 31 July 2007
Resolved 23 July 2007
Electrical › Electric Generation Source (service) › Power Requirement
Issued 18 July 2007 Resolved
Two of the three size 8D batteries was found unable to hold a charge. Replaced in kind.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 31 July 2007
Resolution: Replaced and all batteries charged satisfactory.
Engineering › Lubricating Oil Service System › Filter
Issued 18 July 2007 Resolved
Lube oil for Port & Stbd MDEs contaminated w/ water. Clean & prove propper operation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 July 2007
Resolved 27 July 2007
Resolution: Mechanic & Master flushed all old lube oil from MDEs, lube oil filters & piping. Engines cleaned out and filters replace. MDEs filled w/ new oil and test run satisfactorily. After operation engine oil examined on oil stick and found clean of water.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 18 July 2007 Resolved
Remove old packing and repack shaft log packing gland. Water is freely flowing into boat from Port & Stbd stern gland.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007
Resolved 19 July 2007
Resolution: Completed satisfactorily. Leaking reduced to normal slow drip.
Electrical › Electric Generation Source (service) › Generator
Issued 18 July 2007 Resolved
Port & Stbd belt driven alternators found damaged by technician checking electrical system. Repair both.
Condition: Damaged By Earlier Event
Due 27 July 2007
Resolved 31 July 2007
Resolution: Replaced with remanufactured units.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 June 2007 Resolved
Provide original of COD.
Condition: Unknown
Due 30 July 2007
Resolved 2 July 2007
Documentation › Certificates/Documents › FCC SSL
Issued 6 June 2007 Resolved
Provide FCC ship's radion station license.
Condition: Unknown
Due 30 July 2007
Resolved 2 July 2007
Documentation › Certificates/Documents › FCC SSL
Issued 6 June 2007 Resolved
Provide FCC radiotelephone safety cert.
Condition: Unknown
Due 30 July 2007
Resolved 2 July 2007
Documentation › Certificates/Documents › FCC SSL
Issued 6 June 2007 Resolved
Provide FCC radio operators license.
Condition: Unknown
Due 30 July 2007
Resolved 2 July 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 June 2007 Resolved
Provide required drug and alcohol screening program.
Condition: Unknown
Due 30 July 2007
Resolved 2 July 2007
Communications › Radio Communications › EPIRB
Issued 6 June 2007 Resolved
Register EPIRB w/ NOAA under new owner/operator of vessel.
Condition: Placed in Improper Service
Due 30 July 2007
Resolved 2 July 2007
Lifesaving › Lifefloat › Markings
Issued 6 June 2007 Resolved
Mark all lifesaving equipment w/ new name for vessel.
Condition: Placed in Improper Service
Due 30 July 2007
Resolved 2 July 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2007 Resolved
Post emergency broadcast instructions near radio.
Condition: Unknown
Due 30 July 2007
Resolved 2 July 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 June 2007 Resolved
Provide service certificate for all fire protection equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2007
Resolved 2 July 2007
Documentation › Certificates/Documents › Stability Letter
Issued 6 June 2007 Resolved
Post copy of stability letter. Copy aboard vessel is severely deteriorated and a better copy will be needed.
Condition: Damaged By Earlier Event
Due 30 July 2007
Resolved 2 July 2007
Resolution: Found a not so badly worn copy in the vessel''s file & provided to vessel for basic information of the crew while the OCMI determines the method of replacing the worn copy.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 June 2007 Resolved
Provide charts, pubs, rules for class of vessel, radio instructions and all other pubs & records listed in CG-849-T inspection booklet provided.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2007
Resolved 2 July 2007
Lifesaving › Lifefloat › Paddle
Issued 6 June 2007 Resolved
Provide two paddles per L/F.
Condition: Damaged By Earlier Event
Due 30 July 2007
Resolved 2 July 2007
Electrical › Lighting (service) › Outlet Box
Issued 6 June 2007 Resolved
Replace missing duplex recepticle covers.
Condition: Improper/Lack of Maintenance
Due 30 July 2007
Resolved 2 July 2007
Electrical › Lighting (service) › Outlet Box
Issued 6 June 2007 Resolved
Install an outlet box IWO the shore tie connection and fit w/ proper strain relief.
Condition: Improper Installation
Due 30 July 2007
Resolved 3 July 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2007 Resolved
Repair & prove operation of #2 compartment bilge high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2007
Resolved 2 July 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 June 2007 Resolved
Provide a proper stern light for the size of the vessel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2007
Resolved 3 July 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 June 2007 Resolved
Provide a proper anchor light.
Condition: Improper Installation
Due 30 July 2007
Resolved 3 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 6 June 2007 Resolved
Move portable fire protection equipment to meet the requirements of 46 CFR table 176.810(b).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2007
Resolved 3 July 2007
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 6 June 2007 Resolved
Put vessel's Call Sign with radio emergency placard near VHF radio.
Condition: Placed in Improper Service
Due 30 July 2007
Resolved 3 July 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 March 2007 Resolved
Complete credit hull inspection prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2007
Resolved 31 May 2007
Engineering › Bilge Water Management System › Hose
Issued 16 February 2005 Resolved
Replace cracked piece of bilge suction hose (forward of the starboard engine) in E/R as discussed.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Observed new piece of acceptable hose. Required vessel rep to double clamp; corrected on the spot.
Engineering › Fuel Oil Service System › Heater
Issued 16 February 2005 Resolved
Port side oil line hose lagging worn (IWO of port engine fuel oil filter). - Replace
Due 15 April 2005
Resolved 14 April 2005
Resolution: Vessel representative provided copy of receipt documentating purchase of new fuel hoses.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 16 February 2005 Resolved
Starboard wet exhaust line (overboard discharge) - Double Clamp.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Double Clamped.
Fire Fighting › Fire Hoses › Location
Issued 16 February 2005 Resolved
Fire line hose in E/R hanging - permanently mount.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Hose supported by a bracket.
Fire Fighting › Nozzles › Type
Issued 16 February 2005 Resolved
Replace fire hose nozzle with metal one.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Brass nozzle installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 16 February 2005 Resolved
Remove all water and oil from bilges.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Oil removed with a very small amount of water remaining in forward engine room bilge.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 February 2005 Resolved
(Repair or) replace lazarete bilge high level alarm.
Due 18 March 2005
Resolved 11 March 2005
Resolution: Wire reattached and observed sat audible and visual alarm in wheel house.
Lifesaving › Lifefloat › Retroreflective Material
Issued 16 February 2005 Resolved
Replace retro tape on upper lifefloat.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Lifefloat painted, stecilled with name and capacity, and new retro installed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 February 2005 Resolved
Remove all angel hair on the starboard shelf IWO engine as marked and treat with wood perservative.
Due 18 March 2005
Resolved 15 March 2005
Resolution: All angel hair scraped from shelf, futtock caps and underside of deck planking. Wood treated with an acceptable wood perservative.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2005 Resolved
Stop leak in port side hull planking IWO port engine exhaust. Remove rub rail and make planking available for inspection by CG.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Rub rail removed on 3/11/05. Observed wasted fitting w/ good wood (mahogany) IWO of holes. 3/15 - Four new silicone bronze fastenings installed through rub rail in new holes through hull planking. Existing holes plugged with dowels and sealed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 February 2005 Resolved
Remove portable gasoline generator from vessel.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Generator removed from vessel.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2005 Resolved
Make port engine exhaust overboard discharge watertight.
Due 18 March 2005
Resolved 14 March 2005
Resolution: Stainless exhaust flange pulled; inspected for corrosion. FM5200 added on both sides of flange face with mahogany hull planking to prevent water ingress.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 February 2005 Resolved
Provide proof of annual servicing for fixed fire and portable fire extinguishers by faxing a receipt to the CG.
Due 18 March 2005
Resolved 15 March 2005
Resolution: [name withheld] presented a 6 page guide used to self inspect, weigh and tag portable and fixed extinguishers. Guide faxed to office and provided in case package.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 February 2005 Resolved
Provide repair proposal for wasted bolts attaching starboard shelf to futtock IWO starboard engine as marked.
Due 18 March 2005
Resolved 15 March 2005
Resolution: Observed installed sister fastened with silicone broze ring nails.
Fire Fighting › Fire Pumps
Issued 1 March 2004 Resolved
Provide proof of proper operation of bilge/fire pump, to the satisfaction of an attending marine inspector prior to carrying passengers.
Due 1 March 2004
Resolved 15 March 2004
Resolution: Ran fire and bilge pumps - SAT.
Construction/Loadline › Hull
Issued 1 March 2004 Resolved
Make permanent and proper repairs to lazerette frame #2 from transome iwo port rudder post. Vessel is limited to speeds no more than necessary to to maintain minumum steering & 1000 ft. from from shore with 15 min. rounds & noted in ships log. LEGACY COMPONENT DESC: Hull Plating
Due 15 March 2004
Resolved 15 March 2004
Resolution: Vsl no longer leaks at rudder post while at dock and while underway.
Communications › Radio Communications
Issued 1 March 2004 Resolved
Provide proof of EPIRB battery replacement, vessel limited to 3nm from shore. LEGACY COMPONENT DESC: EPIRB
Due 15 March 2004
Resolved 20 April 2004
Resolution: Provided receipt for battery replacement.
Navigation › Collision/Grounding Avoidance
Issued 1 March 2004 Resolved
Provide proof of proper operation on navigation lights & illumination of magnetic compass, prior to operation after daylight hours. LEGACY COMPONENT DESC: Navigation Lights
Due 15 March 2004
Resolved 8 March 2004
Fire Fighting › Fire Hoses
Issued 1 March 2004 Resolved
Provide fire house, prior to carrying passengers.
Due 15 March 2004
Resolved 15 March 2004
Resolution: Vsl installed a garden hose with metal nosel.
Communications › Radio Communications › EPIRB
Issued 1 March 2004 Resolved
Provide proof of EPIRB test in log & proof of vsl name change.
Due 15 March 2004
Resolved 20 April 2004
Resolution: Proof of logging/name change faxed in to CG.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System
Issued 1 March 2004 Resolved
Provide proof of servicing to fixed fire extinguishing system, prior to carrying passengers.
Due 8 March 2004
Resolved 8 March 2004
Engineering › Fuel Oil Service System
Issued 1 March 2004 Resolved
Make permanent repairs to the fuel supply line into the engine room to include metalic piping through the bulkhead. LEGACY COMPONENT DESC: Hose
Due 15 March 2004
Resolved 15 March 2004
Resolution: Vsl installed metal through hull piping for fuel line from lazerette to engine room.
Engineering › Fuel Oil Service System
Issued 1 March 2004 Resolved
Make permanent repairs to fuel vent screens (30x30) LEGACY COMPONENT DESC: Vent Pipe
Due 15 March 2004
Resolved 8 March 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 1 March 2004 Resolved
Provide proof of Coast Guard approved First Aid kit.
Due 15 March 2004
Resolved 15 March 2004
Resolution: Vsl purchased additonal first aid items to come in compliace with CG requirements. (wire splint)
Lifesaving › Lifebuoys
Issued 1 March 2004 Resolved
Properly attach ring life buoy's lifeline around buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 15 March 2004
Resolved 8 March 2004
Construction/Loadline › Markings
Issued 1 March 2004 Resolved
Provide proper hailing port to stern of vessel.
Due 15 March 2004
Resolved 15 March 2004
Resolution: Vsl applied 3" stickers to hull of vsl.
Operations/Management › Navigation Safety
Issued 1 March 2004 Resolved
Provide proof of current navigation publications including U.S. Coast Pilot and CG Light List LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 15 March 2004
Resolved 8 March 2004
Documentation › Logs/Records
Issued 1 March 2004 Resolved
Provide proof of current drug & alcohol plan to include consortium contract, hotline # posted, policy available, supervisor (60 min training) & verification of pre-employment & post incident testing, prior to carrying passengers. LEGACY COMPONENT DESC: Drug Test Records
Due 15 March 2004
Resolved 15 March 2004
Engineering › Bilge Water Management System
Issued 1 March 2004 Resolved
Double hose clamp fire/bilge pump manifold connections forward of stbd engine. LEGACY COMPONENT DESC: Manifold
Due 15 March 2004
Resolved 15 March 2004
Resolution: Double clamped
Operations/Management › Drills/Instruction
Issued 1 March 2004 Resolved
Make vessel available for sea trials.
Due 15 March 2004
Resolved 15 March 2004
Resolution: Vsl performed sea trials, with a small leak in the forepeak, above the waterline. Notified master about leak and asked the master to address the issue.
Engineering › Fuel Oil Service System
Issued 1 March 2004 Resolved
Install conductors to port & stbd fuel fills. LEGACY COMPONENT DESC: Piping
Due 15 March 2004
Resolved 15 March 2004
Resolution: Vsl installed static electricity conductors and viewing portals on p & s sides of the vsl. Viewed digital pictures of the grounding wires on the lower half.
Documentation › Certificates/Documents
Issued 3 April 2003 Resolved
Provide current DOC. Due to the recent purchase and vessel name change the DOC was not received by vessel reps st the time of the inspection. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 17 April 2003
Resolved 17 April 2003
Documentation › Certificates/Documents
Issued 3 April 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Due 10 April 2003
Resolved 10 April 2003
Resolution: Master and license was present and displayed his licese
Documentation › Certificates/Documents
Issued 3 April 2003 Resolved
Produce and post stability letter. Stability letter could not be produced.
Condition: Placed in Improper Service
Due 17 April 2003
Resolved 17 April 2003
Documentation › Logs/Records
Issued 3 April 2003 Resolved
Display current COI. Current COI was not displayed.
Condition: Unknown
Due 10 April 2003
Resolved 10 April 2003
Documentation › Certificates/Documents
Issued 3 April 2003 Resolved
Although only a recommendaton could not produce proof of Red Cross first aid/CPR cards for 50% of crew.
Due 10 April 2003
Resolved 10 April 2003
Documentation › Manuals/Policy Documentation
Issued 3 April 2003 Resolved
Provide proof of annual drug and alcohol program audit.
Condition: Placed in Improper Service
Due 17 April 2003
Resolved 17 April 2003
Documentation › Logs/Records
Issued 3 April 2003 Resolved
Provide current log book/ bridge log including past/ or for future drills.
Condition: Unknown
Due 10 April 2003
Resolved 10 April 2003
Documentation › Manuals/Policy Documentation
Issued 3 April 2003 Resolved
Provide emergency instructions list and display appropriately.
Condition: Placed in Improper Service
Due 10 April 2003
Resolved 10 April 2003
Operations/Management › Navigation Safety
Issued 3 April 2003 Resolved
Provide proper sized bel.
Condition: Improper Installation
Due 10 April 2003
Resolved 10 April 2003
Resolution: Obtained proper bell at 7.8 inches.
Electrical › Electrical Distribution System (service)
Issued 3 April 2003 Resolved
Dead-end wiring for lighting in wheel house remove or rewire.
Condition: Improper/Lack of Maintenance
Due 10 April 2003
Resolved 10 April 2003
Engineering › Bilge Water Management System
Issued 3 April 2003 Resolved
Replace or repair bilge pump indicator for machinery space.
Condition: Improper/Lack of Maintenance
Due 10 April 2003
Resolved 10 April 2003
Engineering › Diesel Engine (propulsion-electric)
Issued 3 April 2003 Resolved
Attach grounding strap to srstbd engine
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 17 April 2003
Construction/Loadline › Penetrations
Issued 3 April 2003 Resolved
Attach grounding strap iwo terminatted through hull.
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 17 April 2003
Construction/Loadline
Issued 3 April 2003 Resolved
Renew or tighten as necesary keel bolts nos. 3,6,9,10,12,14,16,18,20, and 22 (Numbered from forward bulkhead) iwo wheelhouse compartment.
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 17 April 2003
Resolution: Keel bolts satisfactory replaced and/all tightened.
Construction/Loadline
Issued 3 April 2003 Resolved
IWO lazarette space renew keel bolts number 6 and 7 (counting from stern forward).
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 17 April 2003
Resolution: Keel bolts number 6 and 7 were replaced.
Construction/Loadline › Hull
Issued 3 April 2003 Resolved
Make available for inspection butt blocks fame no. 4 iwo three feet from stabd rudder.
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 17 April 2003
Resolution: After phone conference and discussions with shipyard tech, witnessed repair which consisted of epoxy and sanding- all sat.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 April 2003 Resolved
Secure ladder in forward cabin.
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 17 April 2003
Resolution: Witnessed secured ladder.
Construction/Loadline › Hull
Issued 3 April 2003 Resolved
Crop and renew stem iwo copper sheening.
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 17 April 2003
Resolution: Witnessed repair - all sat.
Construction/Loadline
Issued 3 April 2003 Resolved
Crop and renew stem aft area iwo keel bolt.
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 17 April 2003
Resolution: Witnessed repair - all sat.
Engineering
Issued 3 April 2003 Resolved
Ensure all vital systems hoses are doubled clamped throughout vessel.
Due 25 April 2003
Resolved 24 April 2003
Resolution: Inspected - all sat. Vital system hoses have been double clamped.
Electrical
Issued 3 April 2003 Resolved
Ensure all wiring throughout vessel is properly tie-clipped.
Condition: Improper/Lack of Maintenance
Due 25 April 2003
Resolved 24 April 2003
Resolution: Visually inspected. All satisfactorily tie-clipped.
Engineering
Issued 3 April 2003 Resolved
Provide proof that all flexible hoses meet SAE 1942 standards.
Condition: Improper Installation
Due 25 April 2003
Resolved 24 April 2003
Resolution: Visually inspected on 24Apr03 - all sat.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 3 April 2003 Resolved
Very worn and poor condition of life jackets - Three (3) need replacement.
Condition: Improper/Lack of Maintenance
Due 25 April 2003
Resolved 24 April 2003
Resolution: Three new adult life jackets purchased.
Construction/Loadline › Hull
Issued 3 April 2003 Resolved
Remove unused copper piling in bulkhead and seal properly.
Condition: Improper Installation
Due 25 April 2003
Resolved 24 April 2003
Resolution: Visually inspected - all sat.
Fire Fighting › Fire Hoses
Issued 3 April 2003 Resolved
Replace garden hose with proper fire standard hose. LEGACY COMPONENT DESC: Material
Condition: Improper Installation
Due 25 April 2003
Resolved 24 April 2003
Resolution: Visually inspected- all sat.
Engineering
Issued 3 April 2003 Resolved
Install safety guard bracket on port engine alternator.
Condition: Improper Installation
Due 25 April 2003
Resolved 24 April 2003
Resolution: Visually ispected - all sat.
Lifesaving › Emergency Outfit
Issued 30 May 2002 Resolved
Provide current EPIRB NOAA registration. Vessel restricted to operating not more than 3 miles from shore.
Action required: 705 - Other - as specified
Due 1 July 2002
Resolved 24 June 2002
Lifesaving
Issued 30 May 2002 Resolved
Provide new EPIRB hydrostatic release. Vessel is restricted to operating not more than 3 miles from land.
Action required: 705 - Other - as specified
Due 1 July 2002
Resolved 24 June 2002
Fire Fighting
Issued 14 May 2001 Resolved
PROVE OR SATISFACTORY CONDITION OF FORWARD BII FIRE EXTINGUISHER.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Engineering
Issued 14 May 2001 Resolved
TIGHTEN PACKING ON PORT SHAFT TO REDUCE EXCESSIVE LEAKAGE.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Construction/Loadline
Issued 24 May 2000 Resolved
MAKE REPAIRS TO "MINOR FRAME" HEADS IN E/R IWO FRAMES #4 STBD AND #1, 4, 7,8, 9 ON PORT SIDE.
Condition: Unknown
Due 26 May 2000
Resolved 2 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
CONDUCT UNDERWAY EXAM WITH USCG MARINE INSPECTORS.
Condition: Unknown
Due 26 May 2000
Resolved 2 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
PROVIDE SISTER TO #2 FRAME STBD SIDE IN #1 HOLD.
Condition: Unknown
Due 26 May 2000
Resolved 2 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
PROVIDE NEW BOLTS IWO OF REMOVED BOLTS IN #1 HOLD (3 NEEDED).
Condition: Unknown
Due 26 May 2000
Resolved 2 June 2000
Unknown
Issued 14 May 1998 Resolved
PROVIDE PROOF OF CHEMICAL TESTING PROGRAM
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Unknown
Issued 14 May 1998 Resolved
VSL ALLOWED ONE TIME VOYAGE FROM WINTERPORT MAINE TO OCEAN CITY MARYLAND. THEN NOT TO OPERATE UNTIL A VALID DOCUMENT IS ONBOARD.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 14 May 1998 Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Construction/Loadline
Issued 14 May 1998 Resolved
OPEN CENTER FREEING PORT IN TRANSOM.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Electrical
Issued 14 May 1998 Resolved
PERMANENTLY WIRE SEWAGE DISCHARGE PUMP
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Accommodation/Occupational Safety
Issued 14 May 1998 Resolved
REPAIR BROKEN DOOR HANDLE PORT SIDE.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Construction/Loadline
Issued 14 May 1998 Resolved
INSTALL LANYARDS ON 02 DECK SCUTTLES.
Condition: Unknown
Due 14 May 1998
Resolved 22 May 1998
Lifesaving
Issued 14 May 1998 Resolved
LABLE ALL PFD'S WITH NEW VSL NAME.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 14 May 1998 Resolved
PROVIDE A TOTAL OF 50% PRIMARY LIFESAVING, LIFEFOLATS OR IBA.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 14 May 1998 Resolved
PROVIDE AND REGISTER A 406MHZ CAT I EPIRB
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Unknown
Issued 14 May 1998 Resolved
CONDUCT NEW TO ZONE INSPECTION WITH LOCAL OCMI.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 14 May 1998 Resolved
SEPERATE AND LABLE CHILD PFD'S.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 14 May 1998 Resolved
LABLE RING LIFE BOUY
Condition: Unknown
Due 14 May 1998
Resolved 22 May 1998
Unknown
Issued 14 May 1998 Resolved
BOLT DOWN BOX ON BOW
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998

Casualty record · 2

7 August 2009Routine · role: Involved in a Marine Casualty · activity 3568789
22 August 2009Routine · role: Involved in a Marine Casualty · activity 3577183
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.