FOOL'S GOLD

FOOL'S GOLD is a 1964 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in June 2026, along with 30 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 2 June 2026.

Built
1964
Last inspected
2 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD2652
Flag
UNITED STATES
Maury page id
psix-44683

Documentation record

Registered dimensions (L × B × D)39.2 ft × 13.9 ft × 5.8 ft
Registered tonnagegross 19 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLEO M. JANSEN · TROUTDALE · built 1964
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWHITTIER, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

2 June 2026 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8355475
27 May 2025 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8146797
17 April 2025 Deficiency Check · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8112798
20 May 2024 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7889624
30 May 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7706849
6 April 2023 Drydock Extension · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7677031
2 May 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7442344
16 July 2021 Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7282891
7 July 2021 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7249554
5 March 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7148443
19 August 2020 Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7035591
9 August 2019 Type not recorded
No type recorded · Station Valdez · USCG Arctic District (CGD-A) · Activity 6788500
29 May 2019 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6699911
28 March 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6658483
16 May 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6391106
27 June 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6204772
7 June 2017 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6163599
22 March 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6109967
31 August 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5968616

Deficiency record · 30

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2024 Resolved
Replace life ring buoy light with an approved battery
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2024
Resolved 22 May 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2024 Resolved
Replace all combustible waste receptacles with non-combustible ones with no opens in the sides or bottom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2024
Resolved 22 May 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 April 2023 Resolved
Frame on the portside was self reported as being disconnected from the hull. Tempory repair was made to the satisfaction of the attending marine inspector and perminent repairs will be made in the fall of 2023.
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 17 April 2025
Resolution: Repairs verified.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 July 2021 Resolved
Prove proper operation of the machinery space bilge high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 July 2021
Resolved 8 July 2021
Resolution: Fuse replaced.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 July 2021 Resolved
Provide a ladder for the emergency escape hatch located in the forward passenger seating area. The ladder must meet the requirements of 46 CFR 177.500.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 16 July 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 July 2021 Resolved
Ensure forward escape hatch is gasketed and able to provide a weathertight seal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 16 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2020 Resolved
All portable fire extinguishers installed on vessels shall be of an approved type. The three appropriate fire extinguishers were mounted using improper brackets (46 CFR 181.30-5).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 15 September 2020
Resolution: Rcvd email dtd 14Sep2020 w/ picture showing proper brackets fitted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International Navigation rules. Anchor light inoperable. Daylight and unrestricted visibility operation only.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 15 September 2020
Resolution: Rcvd email dtd 14Sep2020 indicating anchor light bulb replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2020 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. Port and starboard flame screens were holed (46 CFR 182.20-35).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 15 September 2020
Resolution: Rcvd email dtd 14Sep2020 w/ picture showing newly installed flame screens.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019 Resolved
Shutoff valve installed to close against the fuel flow. Port fuel shutoff broke (46 CFR 182.20-40(b)(3).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
Resolution: Corrected prior to our departure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2019 Resolved
Each water light must be of an approved automatic electric type. Wrong batter installed (46 CFR 180.30-1(b).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Rcvd email w/ picture of proper battery.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 May 2019 Resolved
Appropriate for the intended voyage, all vessels must carry adequate & up to date charts, coast pilot, light list, & current tables. Chart dated 2009 not updated, coast pilot & light list were dated 2016, & there were no current tables (46 CFR 185.20-35).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 20 June 2019
Resolution: Rcvd email w/ picture of newly purchased & up to date nav chart & statement indicating new light list, coast pilot, & current tables aboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 May 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents & instructions. Kit missing some items & some items expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Rcvd email indicating newly purchased 160.041 first-aid kit aboard.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 30 May 2019 Resolved
Vessel is to be reasonably safe from electrical shock of personnel. Dead-ended wires in steering gear chain locker & IWO stbd main diesel engine outboard at bulkhead (46 CFR 183.01-5).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Rcvd email indicating dead-end wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2019 Resolved
Fuel lines shall be protected from excessive movement & vibration. Starboard main diesel engine fuel injection lines are missing manufacturers hold down devices (46 CFR 182.20-40(b)(2)).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Rcvd email indicating hold downs installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2019 Resolved
Material specification of nonmetallic material shall possess characteristics for its intended service & environment. Lube oil drain pan line wasted (46 CFR 182.40-1(a)(4)).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Rcvd email indicating oil drain line replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 May 2019 Resolved
Vessels must have navigation lights that are in compliance with the NAVRULES. Masthead light installation improper (46 CFR 183.420, Rule 21(a), Rule 22(c).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Rcvd email w/ picture. New light installed & vertically adjusted.
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2018 Resolved
The life ring was found to be waterlogged, replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2018
Resolution: Replaced with new in kind.
Construction/Loadline › Structures › Door
Issued 17 May 2018 Resolved
Transom gate lock is missing, repair or replace so the gate is able to be secured while underway.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2018
Resolution: New lock installed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 17 May 2018 Resolved
The stowage location for the child lifejackets is not indicated. Mark location on vessel interior to indicate stowage location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2018
Resolved 29 May 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 17 May 2018 Resolved
The Port Tach is not operating properly, drops to 0 when coming in and out of gear.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2018
Resolved 21 May 2018
Resolution: Repaired and operates properlly.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 May 2018 Resolved
Drills during CG inspection where not satisfactory, practice and log drills and schedule CG attendance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2018
Resolved 29 May 2019
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2018 Resolved
The burn cream in the first aid kit was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2018
Resolved 21 May 2018
Resolution: New item purchased.
Construction/Loadline › Structures › Superstructure
Issued 8 June 2017 Resolved
Replace all 12 windows and gaskets in cabin space.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Received photo documentation. Glass and gasket installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 June 2017 Resolved
Replace lifebuoy battery in light
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 27 June 2017
Resolution: Received photo evidence of satisfactory correction
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 June 2017 Resolved
Put retro tape on both sides of lifering
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 27 June 2017
Resolution: Received photo evidence of satisfactory correction
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 8 June 2017 Resolved
Provide proof of consortium and MIS report
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 27 June 2017
Resolution: Received photo evidence of satisfactory correction
Engineering › Bilge Water Management System › Piping
Issued 8 June 2017 Resolved
Label bilge alarms on panel
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 27 June 2017
Resolution: Received photo evidence of satisfactory correction
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 September 2016 Resolved
Update navigation publications to current year.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2016
Resolved 3 October 2016
Resolution: proof has been provide that publications were updated.
Communications › Audible Communications › Horn/Whistle
Issued 22 September 2016 Resolved
Prove proper operation of ship's horn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2016
Resolved 10 October 2016
Resolution: Received video showing horn operates properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.