MAURY USCG vessel records Sign in
← All vessels

NANTASCOT

NANTASCOT is a 1964 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1985, most recently in November 2007, along with 117 deficiencies.

Records from 1985 to 2007. Most recent: inspection, 16 November 2007.

Built
1964
Last inspected
16 November 2007
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WO8992
Flag
UNITED STATES
367087260 (licence lapsed)
Maury page id
psix-44704

Inspections, by type

…with no type recorded4
Years with a record 22 calendar years (1985–2007)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 27.0 ft × 7.7 ft
Registered tonnagegross 77 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WARREN, RI, UNITED STATES · built 1964
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 18 May 2010 · expires 30 June 2011
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WO8992MMSI 367087260 · expired · compulsorily equipped · granted 18 January 2006, cancelled 4 June 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

16 November 2007 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3099488
24 June 2005 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2458993
24 September 2004 MTSA Verification · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2203804
14 May 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2067304
17 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971035
4 June 2003 Examination of Repairs · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1809707
3 January 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1734840
24 October 2002 Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1695455
18 September 2002 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1683778
19 August 2002 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1663245
15 May 2002 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1658551
27 August 2001 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1420570
16 September 2000 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 104179
27 June 2000 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1470569
16 June 2000 Hull Examination · Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1413746
27 January 2000 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 814340
29 July 1999 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1112454
28 July 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1129298
14 May 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 792351
7 July 1997 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1114498
30 May 1997 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1107587
4 March 1997 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1107204
29 May 1996 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1085037
7 May 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1082481
18 October 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1184736
23 June 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 81154
6 June 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 876945
18 April 1995 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 867634
28 March 1995 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1135549
8 June 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1018701
13 May 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 860377
13 May 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 860752
6 August 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1155753
4 June 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 844271
27 May 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1154301
6 April 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1395922
10 July 1992 Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 945284
24 June 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1265963
20 April 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 944715
17 January 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1240141
6 November 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 936895
10 May 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 903660
10 May 1990 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1211353
11 January 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 909208
12 October 1989 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1341996
30 January 1989 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 897347
21 March 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 993145
11 January 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1318961
24 April 1987 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1316387
11 March 1987 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1318244
5 February 1987 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1007264
9 January 1986 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 984907
23 December 1985 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 990031
11 January 1985 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 975078

Deficiency record · 117

Construction/Loadline › Structures › Scupper
Issued 10 August 2005 Resolved
Crop and renew as original wasted section of port bulwarks IWO scupper aft of port boarding door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 31 October 2005
Resolution: Examined satisfactory insert in bulwarks.
Documentation › Certificates/Documents › FCC SSL
Issued 24 June 2005 Resolved
Renew FCC Safety Radiotelephone Certificate.
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 10 August 2005
Resolution: Examined new certificate.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 24 June 2005 Resolved
Provide 2005 Editions of Tidal Current Tables and CG Light List. Current excerpts or copy of Reed's or Eldridge are acceptable substitutes
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 24 August 2005
Resolution: Examined sat. nav pubs.
Construction/Loadline › Structures › Superstructure
Issued 24 June 2005 Resolved
Renew broken port hole glass in pilothouse, stbd/aft
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 10 August 2005
Resolution: Examined newly installed glass in port hole.
Construction/Loadline › Structures › Door
Issued 24 June 2005 Resolved
Renew as original wasted weathertight door frames on main deck port boarding door and 2nd deck door to stairway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 10 August 2005
Resolution: Examined satisfactory repairs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 June 2005 Resolved
Remove or reconnect dead-ended wires/cables on MDE.
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 10 August 2005
Resolution: Examined wires reconnected.
Engineering › Bilge Water Management System › Valve
Issued 24 June 2005 Resolved
Renew broken stop valve handle on sea chest suction line for bilge system.
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 10 August 2005
Resolution: Examined new valve handle.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 24 June 2005 Resolved
Replace missing indicator lights for ground detection system on main switchboard and prove proper operation of same.
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 24 August 2005
Resolution: Lightbulbs replaced. All sat.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 24 June 2005 Resolved
Provide non-conducting mats or gratings for front and rear of main switchboard.
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 10 August 2005
Resolution: Examined newly installed rubber mats.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 September 2004 Resolved
Prove proper operation of bilge alarm for lazerette space.
Action required: 705 - Other - as specified
Due 24 October 2004
Resolved 9 December 2004
Resolution: Tested sat
Engineering › Bilge Water Management System › Manifold
Issued 24 September 2004 Resolved
Properly update instruction for bilge operation.
Action required: 705 - Other - as specified
Due 24 October 2004
Resolved 9 December 2004
Resolution: Tested and witnessed sat.
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 24 September 2004 Resolved
Properly update instruction for bilge operation.
Action required: 705 - Other - as specified
Due 24 October 2004
Resolved 9 December 2004
Resolution: Issued in error.
Engineering › Generator (propulsion-electric) › Battery
Issued 24 September 2004 Resolved
Properly install battery generator
Action required: 705 - Other - as specified
Due 24 October 2004
Resolved 9 December 2004
Resolution: Installed satisfactory
Stability › Water on Deck › General
Issued 24 September 2004 Resolved
Submit fresh water tank plans for approval.
Action required: 705 - Other - as specified
Due 24 October 2004
Resolved 9 December 2004
Resolution: Owner removed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 September 2004 Resolved
Properly install life ring.
Action required: 705 - Other - as specified
Due 24 October 2004
Resolved 9 December 2004
Resolution: Installed sat.
Engineering › Fuel Oil Service System › Hose
Issued 24 September 2004 Resolved
Properly repair fuel leak on sunction line.
Action required: 705 - Other - as specified
Due 24 October 2004
Resolved 9 December 2004
Resolution: Tested Sat.
Deck/Cargo › Holds/Tanks
Issued 14 May 2004 Resolved
Provide Gauging report, to include Bands from Bow to Stern 2' apart from waterline to waterline (port and Starboard).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2004
Resolution: Provided report and inserted required steel where required.
Construction/Loadline › Structures
Issued 14 May 2004 Resolved
Renew frames in shaft alley port side and starboard side (side shell)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2004
Resolution: Renewed frames on both sides on side shell.
Construction/Loadline › Structures
Issued 14 May 2004 Resolved
Renew all floor frames in sewage void and longitudinal frames on port and starboard side. (4 frames on each side)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2004
Resolution: Renewed all floor frames in sewage void and longitudinal frames on port and starboard side.
Construction/Loadline
Issued 14 May 2004 Resolved
Renew all floor frames in void #1 below longitudinal frames both port and starboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2004
Resolution: Renewed all floor frames in Void #1 below longitudinal frames both port and starboard.
Construction/Loadline › Structures
Issued 14 May 2004 Resolved
Renew Frame from Longitudinal frame to fuel tank in engine room as marked. (starboard side)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2004
Resolution: Renewed frame from longitudinal frame to fuel tank in engine room as marked.
Construction/Loadline › Structures
Issued 20 June 2003 Resolved
Make proper repairs to shaft alley aft bulkhead as discussed, ensuring insert area is cutback to good metal (no less than .188"). LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 8 July 2003
Engineering › Fuel Oil Service System › Valve, Control
Issued 20 June 2003 Resolved
Until reach rod for stbd fuel cutout is repaired valve shall remain closed. After every run valve shall be opened to level tanks and then reclosed.
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 8 July 2003
Electrical › Electrical Distribution System (service)
Issued 4 June 2003 Resolved
Relocate or make weathertight and bracket wire on aft stairwell outlet. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Construction/Loadline › Structures
Issued 4 June 2003 Resolved
Provide audio gauge of shaft alley aft bulkhead and make permanent repairs to bulkhead as needed. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 11 June 2003
Resolved 20 June 2003
Electrical › Electrical Distribution System (service)
Issued 4 June 2003 Resolved
Remove extension cord wire to oil burner and hard mount wire in junction box. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Electrical › Electrical Distribution System (service)
Issued 4 June 2003 Resolved
Properly mount/bracket power wire for Depth sounder as well as transducer wire in sewage space. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Electrical › Electrical Distribution System (service)
Issued 4 June 2003 Resolved
Properly wire lights on bulkhead behind bar area with junction boxes and properly bracket wires. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Electrical › Electrical Distribution System (service)
Issued 4 June 2003 Resolved
Properly bracket wires for Bar outlet and bilge alarm wire in shaft alley for lazzerette. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Communications › Alarms/Indicators
Issued 4 June 2003 Resolved
Properly mount bilge alarm for shaft alley space. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Electrical › Lighting (service)
Issued 4 June 2003 Resolved
Properly mount, repair, and rewire docking lights on Mast. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Construction/Loadline › Structures
Issued 4 June 2003 Resolved
Make proper repairs to tonnage opening on aft bulkhead. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 27 August 2003
Engineering › Fuel Oil Service System
Issued 4 June 2003 Resolved
Make proper repairs to starboard fuel cutout reach rod. LEGACY COMPONENT DESC: Valve, Control
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Electrical › Electric Supply System (service)
Issued 4 June 2003 Resolved
Install proper batteries or battery box for Generator. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Communications › Internal Communications System
Issued 4 June 2003 Resolved
Make PA speakers on upper deck operable and remove old speaker wire running aft on upper deck.
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Electrical › Electrical Distribution System (service)
Issued 4 June 2003 Resolved
Properly bracket stern light wire running across canopy top support pipe. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Lifesaving
Issued 4 June 2003 Resolved
Make rescue platform (Man overboard ladder) readily accessable and deployable and provide means to recover an unconscious person.
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 20 June 2003
Construction/Loadline › Hull
Issued 24 October 2002 Resolved
Remove improper installation of steel insert and repair in accordance with approved repair plans and procedure (letter dated 15OCT02) prior to carrying passengers. LEGACY COMPONENT DESC: Side Shell
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 November 2002
Resolved 3 January 2003
Resolution: Witnessed grinding out of improper welds to insert plate and re-welding. Insert plate 18" x 30" located in the #2 void space. Found satisfactory.
Construction/Loadline › Hull
Issued 24 October 2002 Resolved
Relace all wasted frames and tripping brackets in 2nd void/or provide gauging report to prove wastage on above items. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 November 2002
Resolved 3 January 2003
Resolution: Re examined frames and tripping brackets in the #2 void space and issued an inspection note to replace at next credit drydock but not later than 31 May 2004.
Stability
Issued 18 September 2002 Resolved
Noted that .75 long ton of solid ballast installed at a vertical center of gravity approximately 1.5 feet above the baseline is missing from the vessel. LEGACY COMPONENT DESC: letter
Due 18 October 2002
Resolved 24 October 2002
Resolution: Found the cement was in fact installed in the skeg.
Fire Fighting › Fire Pumps
Issued 18 September 2002 Resolved
Prove proper operation of electric fire pump NLT 30SEP02
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Tested operation of electric fire pump. Test Sat.
Engineering
Issued 18 September 2002 Resolved
Prior to carrying passengers properly label bilge manifold to reflect accurate bilge valves.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Bilge manifold has been properly labeled.
Engineering
Issued 18 September 2002 Resolved
Prior to carrying passengers install check valve in forepeak bilge line and test forepeak bilge suction.
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Check valve has been installed in the forepeak suction line.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 18 September 2002 Resolved
Repair all broken windows NLT 30SEP02.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: All broken windows have been installed.
Accommodation/Occupational Safety
Issued 18 September 2002 Resolved
Properly repair side door window installation NLT 30SEP02.
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Broken window in side door has been installed.
Engineering
Issued 18 September 2002 Resolved
Repair bilge float in shaft alley NLT 30SEP02. Float is mounted wrong.
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Bilge float in shaft alley has been properly installed and tested.
Electrical › Electrical Distribution System (service)
Issued 18 September 2002 Resolved
Install cover on Aft A.C. receptacle on Aft stairwell NLT30 SEP02. LEGACY COMPONENT DESC: Outlet Box
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Aft A.C. recepatacle cover is properly installed.
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Label escape hatch in E/R and indicate proper direction of turn handle. NLT30SEP02. LEGACY COMPONENT DESC: Scuttle
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Escape hatch has been labeled and indicates proper direction for opening and closing.
Communications › Alarms/Indicators
Issued 18 September 2002 Resolved
Repair oil pressure gauge on bridge NLT30SEP02. LEGACY COMPONENT DESC: Lube Oil Low Pressure Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Oil pressure gauge on bridge has been installed and tested.
Construction/Loadline › Hull
Issued 18 September 2002 Resolved
Prior to carrying passengers properly repair port side shell including bent frame in 2nd void space. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Side shell has been improperly repaired a neww CG-835 is issued to reflect current situation.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 15 May 2002 Resolved
Lag main engine exhaust piping.
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 23 May 2002
Engineering
Issued 15 May 2002 Resolved
Replace generator cooling line hose.
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 23 May 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 15 May 2002 Resolved
Cap old marine sanitation discharge line.
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 23 May 2002
Engineering
Issued 15 May 2002 Resolved
Install a guard over belt for generator.
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 23 May 2002
Construction/Loadline › Hull
Issued 15 May 2002 Resolved
Gauge bulkhead between engine room and the marine sanitation compartment.
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 23 May 2002
Resolution: Lower section of the bulkhead between the engine room and marine sanitation compartment has been cropped out 36" x48" along with bilge piping. Witnessed fit up and welding with a final hose test to newly installed bulkhead plating.
Construction/Loadline
Issued 27 August 2001 Resolved
Replace missing strainer for the bilge system in the sewage void.
Condition: Unknown
Due 10 September 2001
Resolved 31 October 2001
Navigation
Issued 27 August 2001 Resolved
Provided T handle to access auxiliary steering fitting.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Lifesaving
Issued 27 August 2001 Resolved
limited to carrying 214 adults and 20 children.
Condition: Unknown
Due 10 September 2001
Resolved 31 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
Make proper repairs to the man hole gaskets and provide proper means of securing.
Condition: Unknown
Due 10 September 2001
Resolved 31 October 2001
Electrical
Issued 27 August 2001 Resolved
Provide cover for light fixture in bar storage area.
Condition: Unknown
Due 10 September 2001
Resolved 31 October 2001
Accommodation/Occupational Safety
Issued 27 August 2001 Resolved
Provide A-15 door for oil burner space.
Condition: Unknown
Due 10 September 2001
Resolved 31 October 2001
Engineering
Issued 27 August 2001 Resolved
Corrected malfunctioning remote emergency fuel shut off valves
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Accommodation/Occupational Safety
Issued 27 August 2001 Resolved
Properly labeled engine room emergency escape scuttle.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Accommodation/Occupational Safety
Issued 27 August 2001 Resolved
Replace 2 broken windows on main deck.
Condition: Unknown
Due 10 September 2001
Resolved 31 October 2001
Navigation
Issued 27 August 2001 Resolved
Provide light for magnetic compass.
Condition: Unknown
Due 10 September 2001
Resolved 31 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
Properly install check valves in bilge system.
Condition: Unknown
Due 10 September 2001
Resolved 31 October 2001
Accommodation/Occupational Safety
Issued 29 July 1999 Resolved
Renew broken pilot house window.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 29 July 1999 Resolved
Renew ring bouys in disrepair.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 29 July 1999 Resolved
Properly attach line for ring bouy waterlight 3 to 6 feet in length to replace 18 foot lanyard presently in attached.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Construction/Loadline
Issued 29 July 1999 Resolved
Properly secure bilge piping in the muffler space.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Construction/Loadline
Issued 29 July 1999 Resolved
Provide proper watertight fittings for bilge alarm cable runs through watertight bulkhead penetrations.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Navigation
Issued 29 July 1999 Resolved
Post legible radio placard next to all radio installations with emergency broadcast instructions.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Fire Fighting
Issued 29 July 1999 Resolved
Deck insulation chipped and broken. Make proper repair to restore as original.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Fire Fighting
Issued 29 July 1999 Resolved
Properly mount and service portable fire extinguishers.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Engineering
Issued 29 July 1999 Resolved
Starting battery terminals corroded.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Engineering
Issued 29 July 1999 Resolved
Emergency fuel shut off reach rod and fore peak reach rod hand wheels obstructed by close proximity to the main deck. Make reach rod handles easily operable.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 29 July 1999 Resolved
Provide US Coast Guard Approved First Aid Kit on board vessel. Approval number 160.041.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Electrical
Issued 28 July 1998 Resolved
PROVIDE NON-CONDUCTIVE MATTING FOR THE DECK IN FRONT OF THE MAIN SWITCHBOARD.
Condition: Unknown
Due 8 August 1998
Resolved 13 August 1998
Engineering
Issued 28 July 1998 Resolved
ADJUST SHAFT PACKING AND REMOVE EXCESS WATER FROM THE COMPARTMENT FORWARD OF THE LAZARETTE.
Condition: Unknown
Due 8 August 1998
Resolved 13 August 1998
Lifesaving
Issued 28 July 1998 Resolved
REPAIR/REPLACE 33 ADULT AND 11 CHILD PFD'S. VESSEL MAY CARRY A MAXIMUM OF 170 PASSENGERS UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 8 August 1998
Resolved 13 August 1998
Lifesaving
Issued 28 July 1998 Resolved
LABEL EMERGENCY ESCAPE HATCH FROM ENGINE IN THE MAIN DECK PASSENGER COMPARTMENT.
Condition: Unknown
Due 8 August 1998
Resolved 13 August 1998
Lifesaving
Issued 28 July 1998 Resolved
PROVIDE DONNING INSTRUCTIONS FOR EACH TYPE LIFEJACKET ON BOARD.
Condition: Unknown
Due 8 August 1998
Resolved 13 August 1998
Engineering
Issued 28 July 1998 Resolved
REPAIR FUEL TANK VENTS SO THAT THEY DO NOT VENT TO PASSENGER COMPARTMENT.
Condition: Unknown
Due 8 August 1998
Resolved 13 August 1998
Electrical
Issued 28 July 1998 Resolved
REPLACE GUARD ON LIGHT IN MAIN DECK PASSENGER COMPARTMENT FORWARD PORT LIGHT.
Condition: Unknown
Due 8 August 1998
Resolved 13 August 1998
Construction/Loadline
Issued 14 May 1998 Resolved
Renewed 1/4" side shell plate approximately 10' x 30" and 5/16" bottom plate approximately 8' x 6' inway of starboard mid-body chine.
Condition: Unknown
Due 30 May 1998
Resolved 25 June 1998
Accommodation/Occupational Safety
Issued 29 May 1996 Resolved
MAKE PERMANENT REPAIRS TO UPPER DECK SEATING WHERE FRACTURED AND LOOSE ON PORT AND STARBOARD SIDES AFT OF PILOT HOUSE.
Condition: Unknown
Due 8 June 1996
Resolved 1 July 1996
Accommodation/Occupational Safety
Issued 29 May 1996 Resolved
REPAIR FRACTURE IN PORT LOADING DOOR.
Condition: Unknown
Due 8 June 1996
Resolved 1 July 1996
Construction/Loadline
Issued 29 May 1996 Resolved
REWELD FRACTURED WELDS ON FRAMES 3 & 4 FROM THE FORWARD BULKHEAD ON THE STARBOARD SIDE OF #5 VOID (JUST INBOARD OF NEW LONGITUDINAL STRINGER).
Condition: Unknown
Due 8 June 1996
Resolved 1 July 1996
Lifesaving
Issued 29 May 1996 Resolved
INSTALL RETRO REFLECTIVE TAPE ON RING BUOY AT FOUR EQUALLY SPACED POINTS.
Condition: Unknown
Due 8 June 1996
Resolved 1 July 1996
Construction/Loadline
Issued 18 April 1995 Resolved
CROP OUT AND RENEW AS ORIGINAL, WASTED-#3 FROM STARBOARD BULKHEAD STIFFENERON AFT BULKHEAD, MSD COMPARTMENT NO LATER THAN 18 MAY, 1995.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Accommodation/Occupational Safety
Issued 18 April 1995 Resolved
REPLACE BROKEN WINDOW ON PORT SIDE OF VESSEL, #3 FROM BOW, NO LATER THAN 18MAY, 1995.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 18 April 1995 Resolved
REPLACE GASKETS TO HATCHES FOR COMPARTMENTS NO. 1 AND 2, NO LATER THAN 18 MAY, 1995.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 18 April 1995 Resolved
CROP OUT AND RENEW AS ORIGIANL, STARBOARD LONGITUDINAL WHERE WASTED, IN MSDCOMPARTMENT, NO LATER THAN 18 MAY, 1995.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 18 April 1995 Resolved
CROP OUT AND RENEW AS ORIGINAL, PORT AND STARBOARD LONGITUDINALS, WHERE WASTED, IN SHAFT ALLEY COMPARTMENT, NO LATER THAN 18 MAY, 1995.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 18 April 1995 Resolved
CROP OUT AND RENEW AS ORIGINAL, ALL WASTED BULKHEAD STIFFENERS IN SHAFT ALLEY COMPARTMENT FORWARD BULKHEAD NO LATER THAN 18 MAY, 1995.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 18 April 1995 Resolved
RENEW GASKETING, WHERE MISSING, ON BOTH WEATHER DECK LOADING DOORS.
Condition: Unknown
Due 18 April 1995
Resolved 2 May 1995
Lifesaving
Issued 18 April 1995 Resolved
LABEL VESSEL'S NAME ON TWO CHILD AND FOUR ADULT PFD'S. FAILED ONE CHILD AND FIVE ADULT PFD'S.
Condition: Unknown
Due 18 April 1995
Resolved 2 May 1995
Construction/Loadline
Issued 18 April 1995 Resolved
PROPERLY PLACE VESSEL'S NAME AND HOME PORT ON VESSEL NO LATER THAN 21 APRIL, 1995.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Lifesaving
Issued 18 April 1995 Resolved
PROPERLY REPAIR, OR REMOVE FROM VESSEL TWO RING BUOYS WITH ROTTED LINE.
Condition: Unknown
Due 18 April 1995
Resolved 2 May 1995
Lifesaving
Issued 18 April 1995 Resolved
PROVIDE 50 FT. THROWING LINE FOR RING BUOY ON BOARD, AND PROPERLY LABEL RING BUOY WITH VESSEL'S NAME AND HOME PORT.
Condition: Unknown
Due 18 April 1995
Resolved 2 May 1995
Construction/Loadline
Issued 28 March 1995 Resolved
CROP OUT AND RENEW 12"X6" WASTED SECTION LOCATED IN STEERING COMPARTMENT FORWARD BULKHEAD LOWER PORT SIDE.
Condition: Unknown
Due 23 April 1995
Resolved 30 March 1995
Construction/Loadline
Issued 28 March 1995 Resolved
CLEAN WASTE FROM STEERING COMPARTMENT SHAFT CASING AND BILGE SUCTION STRAINER TO MAKE THEM AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 23 April 1995
Resolved 30 March 1995
Construction/Loadline
Issued 28 March 1995 Resolved
REPLACE BILGE SUCTION STRAINER IN SHAFT ALLEY.
Condition: Unknown
Due 23 April 1995
Resolved 30 March 1995
Construction/Loadline
Issued 28 March 1995 Resolved
CLEAN DECK IN SHAFT ALLEY TO MAKE IT AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 23 April 1995
Resolved 30 March 1995
Construction/Loadline
Issued 28 March 1995 Resolved
REPLACE BILGE SUCTION STRAINER IN VOID FORWARD OF ENGINE COMPARTMENT.
Condition: Unknown
Due 23 April 1995
Resolved 30 March 1995
Construction/Loadline
Issued 28 March 1995 Resolved
CROP OUT AND RENEW HATCH COAMING ON VOID FORWARD OF ENGINE COMPARTMENT.
Condition: Unknown
Due 23 April 1995
Resolved 30 March 1995
Engineering
Issued 28 March 1995 Resolved
REPLACE ELBOW ON SHAFT COOLING LINE IN STEERING COMPARTMENT.
Condition: Unknown
Due 23 April 1995
Resolved 30 March 1995
Engineering
Issued 13 May 1994 Resolved
MAKE PERMANENT REPAIR TO MAIN ENGINE EXHAUST LEAK AND MISSING LAGGING.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Lifesaving
Issued 27 May 1993 Resolved
PROVIDE ADDITIONAL 11 ADULT PFD'S, UNTIL SUCH TIME TOTAL PERSONS ALLOWED ISREDUCED TO 248.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Lifesaving
Issued 27 May 1993 Resolved
LABEL LIFE JACKET STOWAGE MAIN DECK.
Condition: Unknown
Due 27 June 1993
Resolved 24 June 1993
Lifesaving
Issued 27 May 1993 Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 June 1993
Resolved 24 June 1993
Accommodation/Occupational Safety
Issued 27 May 1993 Resolved
REPLACE PORTSIDE MAIN DECK WINDOW WHERE BROKEN.
Condition: Unknown
Due 27 June 1993
Resolved 24 June 1993
Engineering
Issued 27 May 1993 Resolved
PRIOR TO OPERATION RENEW FUEL TANK VENT FLAME SCREEN.
Condition: Unknown
Due 4 June 1993
Resolved 24 June 1993
Electrical
Issued 27 May 1993 Resolved
REPLACE MAINE DECK LIGHT BULBS AND GUARDS WHERE MISSING.
Condition: Unknown
Due 27 June 1993
Resolved 24 June 1993
Navigation
Issued 10 May 1990 Resolved
RENEW STEERING CABLE.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Construction/Loadline
Issued 10 May 1990 Resolved
RENEW WINDOW IN MAIN DECK SLIDING DOOR PORT.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Lifesaving
Issued 5 February 1987 Resolved
12 ADULT AND 2 CHILDRENS LIFE JACKETS CONDEMED. SEVERAL CORK, KAPOK AND FOAM TYPE. THE FOAM TYPE SHOWED EVIDENCE OF DAMAGE FROM RATS SHREDDING THEFILLING, APPARANTLY FOR NEST BUILDING.
Condition: Unknown
Due 5 February 1987
Resolved 5 February 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.