SOUTHERN ROSE

SOUTHERN ROSE is a 1964 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2016, most recently in January 2026, along with 85 deficiencies and 3 casualty investigations between 2019 and 2023.

Records from 2016 to 2026. Most recent: inspection, 30 January 2026.

Built
1964
Last inspected
30 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 January 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH8667
Flag
UNITED STATES
Maury page id
psix-44706

Documentation record

Registered dimensions (L × B × D)59.6 ft × 21.4 ft × 5.3 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHI-TIDE BOAT WORKS · WILLISTON NC, UNITED STATES · built 1964
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

30 January 2026 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8303981
4 November 2025 Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8259681
27 October 2025 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8259576
13 March 2025 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8093091
23 January 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8068868
8 February 2024 Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7862884
16 January 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7849850
12 December 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7838224
23 October 2023 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7813197
20 October 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7830833
12 June 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7713265
1 May 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7678656
5 January 2023 Administrative Inspection · Deficiency Check · Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7616989
27 January 2022 Administrative Inspection · In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7386695
12 January 2022 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7379451
28 October 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7347589
23 February 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7145192
26 January 2021 Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7131135
24 January 2020 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6895693
24 August 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6795245
1 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6674283
10 December 2018 Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6594985
23 March 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6383595
7 February 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351038
2 February 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6085129
27 January 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6080131
25 October 2016 Internal Structural Exam · Examination of Repairs · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6029233
26 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5953278
11 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5874774
28 January 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5805708
21 January 2016 Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5801279

Deficiency record · 85

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2026 Resolved
Vessel is required to have one life jacket for each person carried on board. Vessel was in possession of only 50 adult, 20 child, and 4 infant life jackets in satisfactory condition. Maximum Persons on board limited to 50 until corrected.
Action required: 705 - Other - as specified
Resolved 6 February 2026
Resolution: attended vessel and verified rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2026 Resolved
Both shaft seals were leaking beyond acceptable limits. Adjust or replace packing prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2026
Resolution: recieved video evidence of rectification
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 February 2026 Resolved
Smoke detectors were present but not installed. Install and verify operation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2026
Resolution: attended vessel and verified rectification
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 6 February 2026 Resolved
02 protective globes over light bulbs were missing. One on exterior STBD side walkway and one over main deck accommodation area entrance.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2026
Resolved 11 February 2026
Resolution: Recieved photographic evidence of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. MI observed transmission fluid leaking at approx 3-4 drips per second. Vessel is to correct transmission fluid leakage prior to carriage of passengers. 46 CFR 182.100
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 February 2026
Resolution: observed operation without leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. MI observed water cooled engine exhaust with corroded hose clamps. Vessel shall replace corroded hose clamps and ensure proper operation of system prior to carriage of passengers. 46 CFR 182.100
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 February 2026
Resolution: observed newly replaced hose clamps
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 March 2025 Resolved
Vessels described by 46CFR175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not have installed interconnected fire detection system. Install system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2025
Resolution: Master provided proof of procurement of UL217 smoke detectors.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2025 Resolved
The master shall conduct sufficient drills and give sufficient instructions ensure that all crew members are familiar with their duties during emergencies. Upon hiring vessel master and crew successfully run abandon ship, man overboard, and fire fighting drills provide documentary proof of drills.
Action required: 705 - Other - as specified
Resolved 11 April 2025
Resolution: Vessel provided proof of drill completion with hired captain and crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2025 Resolved
All machinery be installed and maintained in such a manner as to afford adequate protection against personal injury. Starboard engine is missing machinery guard, reinstall missing guard. Cite: 46 CFR 185.05-1 // old T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2025
Resolution: Machinery guard was isntalled, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2025 Resolved
Flexible USCG Type A1, A2, B1 or B2 flexible hose may be installed with two hose clamps per end. Starboard generator fuel line missing 2nd hose clap. Install.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2025
Resolution: Second hose clamp was installed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 March 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of navigation rules. Starboard navigation light dim, replace. Vessel is limited to daylight operations until replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 March 2025
Resolution: Starboard navigation light was replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2025 Resolved
A vessel over 26' in length must carry a minimum of one life ring buoy, of which must be fitted with with one floating water light, unless limited to daytime operation. Water light battery was expired, replace expired battery or provide serviceable water light. Limited to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 March 2025
Resolution: The expired waterlight battery was replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2025 Resolved
A vessel over 26' in length on a oceans or coastwise route must carry a minimum of one life ring buoy, of which must be orange in color. Vessel only has white ring buoys. Install one orange with appropriate vessel name.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2025
Resolution: Vessel replaced two white ring buoys with orange ones, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 May 2023 Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings. Fuel hoses on the generator did not have hose clamps to sufficiently attach hoses.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2023
Resolved 8 May 2023
Resolution: Vessel owner sent in satisfactory photos of new hose clamps on all the fuel hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 May 2023 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Vessels bilge discharge piping had a leak at one of the fittings and a strainer that was found to be wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 8 May 2023
Resolution: Vessel sent in satisfactory photos of new pipe that was fabricated and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2023 Resolved
Each water light must be of an approved automatic electric type, constructed in accordance with subpart 161.010 of this chapter, except as allowed under paragraph (c) of this section. Vessels water light did not have the approved battery type in it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 June 2023
Resolution: Vessel replaced battery in waterlight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2023 Resolved
Electrical installations shall be to the satisfaction of the OCMI. The following electrical deficiencies were found: *Vessel had excessive wire bundles and dead end wires in the engine room and under the bridge console. *Vessel had a junction box behind the concession stand missing a cover. *Wire straps in the tank room and fwd storage room were found with plastic securing straps.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 24 July 2023
Resolution: Loose wiring was removed or placed into junction boxes.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 May 2023 Resolved
Penetrations and openings in watertight bulkheads must— Have means to make them watertight. Bilge piping transiting through the engine room fwd bulkhead leading into the vessels tank room was not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 June 2023
Resolution: Vessel sent in photos of penetration appearing to be sealed up.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 May 2023 Resolved
Each hatch exposed to the weather must be a weathertight door with permanent watertight coamings of 6 inches. Door coaming on the port side leading into the main cabin was not made weathertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 June 2023
Resolution: Vessel sent in photos of new door threashold appearing to meet the watertight requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2023 Resolved
Life preservers for children, when provided, shall be stowed separately. Vessels child size L.J.'s were not stowed seperatly on the upper deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 June 2023
Resolution: Vessel sent in photos of the child L.J.s appearing to be seperated and labeled properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 January 2023 Resolved
The individual bilge suction lines shall be led to a central control point or manifold. Fixed bilge system throughout vessel was significantly wasted and several valves on manifold were not operational. Submersible electric pumps installed in lieu of fixed bilge system is not permitted as primary bilge system. Fixed bilge system must be properly repaired and tested in presence of MI prior to vessel returning to operation. 46 CFR 182.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2023
Resolved 7 April 2023
Resolution: Vessel sent in satisfactory videos of bilge system taking suction in all spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2022 Resolved
At each inspection all observed unsafe practices must be corrected. Vessel has a light switch hanging and not secured to the overhead in the fuel tank compartment. Properly mount the light switch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2022
Resolved 14 March 2022
Resolution: Received photographic evidence of installed switch.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 9 March 2022 Resolved
At each inspection all observed unsafe practices must be corrected. A/C shielding has a stabbing hazard with sharp edges in the vicinity where passengers have access.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2022
Resolved 14 March 2022
Resolution: Received photographic evidence of repaired a/c unit. See documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 March 2022 Resolved
Equipment installed but not required must be installed and maintained in accordance with a recognized industry standard acceptable to the Commandant. Smoke detectors on board the vessel are expired. Remove or replace with non-expired ones.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2022
Resolved 14 March 2022
Resolution: Received photographic evidence of new smoke detectors. See documents.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 March 2022 Resolved
A vessel must carry a first aid kit under approval series 160.041 or a kit with equivalent contents. First aid kit was missing contents and had expired items. Replace expired and missing items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2022
Resolved 14 March 2022
Resolution: Received photographic evidence of new approved first aid kit. See documents.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 March 2022 Resolved
The owner of a documented vessel must annually renew each endorsement upon the current Certificate of Documentation for that vessel in accordance with 67.163.Vessels COD is expired and may not operate with passengers. Vessel can operate 6 or less passengers for hire provided the vessel has proper state documentation, and the requirements of 46 CFR 176.114 shall apply. Equipment required by the certificate of inspection shall not be removed or altered without the permission of the cognizant officer in charge marine inspection (OCMI).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2022
Resolution: Received documentary evidence that vessels COD is current.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2021 Resolved
Lifejackets are missing reflective solas tape. Replace tape or life jackets. Passenger count reduced to 76 adults and 27 children until renewed/replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2021
Resolved 17 March 2021
Resolution: Vessel owner provided photographic evidence of repaired/replaced solas tape on lifejackets.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2021 Resolved
Engine room has wasted frame port side outboard shaft and port side inboard post and starboard side inboard post has wastage. Submit repair proposal to USCG Sector Mobile.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Repairs completed IAW repair proposal, pictures attached in documents.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2021 Resolved
Forpeak has visual caulk that shows through and is moist. Submit repair proposal to USCG Sector Mobile to include collision bulkhead repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Repairs completed IAW repair proposal, pictures attached in documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 March 2021 Resolved
Engine room and forepeak have through hull fittings open to adjacent compartments. Make compartments watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 10 March 2021
Resolution: Throught hulls were repaired while inspectors were on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 March 2021 Resolved
Bilge system in fuel tank room doesn't illuminate. Make light operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2021 Resolved
Electrical connections in steering gear compartment are hanging in the bilge. Protect electrical connections from wet or corrosive environments.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 10 March 2021
Resolution: Item was corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2021 Resolved
There are numerious daisy chained electrical appliances plugged into each extension cord. Remove unneeded items or make perminent connections via outlet boxes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 10 March 2021
Resolution: Dasiy chained items were unplugged and removed during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2021 Resolved
Life rings (02), one is deteriorated beyond repair and one needs vessel name affixed to ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 10 March 2021
Resolution: Ring buoys were replaced and labeled while on inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2021 Resolved
Battery on starboard side has a wing nut connection. Replace wing nut with perminent connection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 March 2021 Resolved
Nautical charts are not current. Replace with current charts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 March 2021 Resolved
FCC Safety radio certificate is expired. Renew safety certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 March 2021 Resolved
Access to the roof hatch is not weathertight. Make access weathertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2021 Resolved
Fire extinguishers were not being recorded as serviced. Prove monthly inspection of fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2021 Resolved
Secure and reinforce hand rails on weatherdeck and 02 deck ladder well.
Action required: 705 - Other - as specified
Resolved 11 February 2021
Resolution: Handrails secured with new end cap and additional hardware.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 February 2020 Resolved
Bilge pump in forward storage did not operate. Repair or replace pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2020
Resolution: Replaced bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 February 2020 Resolved
Bilge pump in aft steering compartment did not operate. Repair or replace bilge pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2020
Resolution: Replaced bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2020 Resolved
Multiple wires cut and unused in the engine room. Repair and reattach or remove unused wire runs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 February 2020
Resolution: Removed unused wire runs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 February 2020 Resolved
Two life rings have deterioration that potenially cause water intrusion if thrown into water. Replace life rings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2020
Resolution: Ordered and installed two new life bouys. Sent pictures to verify proper installation and marking.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 February 2020 Resolved
Vessel had expired flares leaving only three with valid dates. Obtain three more red flares or orange smoke signals to meet minimum requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2020
Resolution: Purchased additional required pyro.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 26 February 2018 Resolved
Exhaust cooling had kinked cooling line, 46CFR182.220
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 23 March 2018
Resolution: Repaired cooling line.
Stability › Water on Deck › General
Issued 26 February 2018 Resolved
Port side coaming for accomodation space missing, 46CFR179.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 23 March 2018
Resolution: Installed port side coaming for accomodation space.
Navigation › Piloting/Steering › Marine Charts
Issued 26 February 2018 Resolved
Navigation charts need updated for area of operation, 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 23 March 2018
Resolution: Obtained corrected charts.
Stability › Watertight Integrity › General
Issued 30 January 2017 Resolved
Fwd void: Seal fixed bilge line thru hull pipe, clean & seal. Seal any wires going thru bulkheads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Through hull fittings were sealed.
Stability › Watertight Integrity › General
Issued 30 January 2017 Resolved
Storage room: Seal wires in space going thru bulk heads and any piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Through hull fittings sealed.
Stability › Watertight Integrity › General
Issued 30 January 2017 Resolved
Tank space: Seal any wires/ piping thru bulk heads as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Through hull fittings sealed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 January 2017 Resolved
Engine room: Mount fire extinguisher in space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Fire extinguisher mounted.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 January 2017 Resolved
Engine room: Clean out battery boxes in space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Battery boxes cleaned out.
Stability › Watertight Integrity › General
Issued 30 January 2017 Resolved
Engine room: Seal both bulkheads where wires or pipes are going thru.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Through hull fittings sealed.
Stability › Watertight Integrity › General
Issued 30 January 2017 Resolved
Rudder room: Seal thru thru hull fittings in space where wires or pipes run thru bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Through hull fittings sealed.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 30 January 2017 Resolved
Mouse anchor line shackles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Anchor shackle moused.
Navigation › Piloting/Steering › Marine Charts
Issued 30 January 2017 Resolved
Provide updated charts for area of operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: New updated chart provided.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 January 2017 Resolved
Secure refrigerator doors from accidental opening.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Refrigerator secured.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 January 2017 Resolved
Post EAP in formation and hot line where crew can view.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: EAP hotline posted.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 January 2017 Resolved
Replace on life ring that was found w/ torn safety line and label as such.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: New life ring purchased and examined.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 January 2017 Resolved
Replace battery for life ring water light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Battery replaced and checked.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 30 January 2017 Resolved
Provide and post waste management plan.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 2 February 2017
Resolution: Waste management plan posted.
Stability › Watertight Integrity › General
Issued 23 November 2016 Resolved
Main deck into parlor area needs six inch coaming for entrances on port and starboard side.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 December 2016
Resolved 30 January 2017
Resolution: Coaming was permanently installed.
Stability › Watertight Integrity › General
Issued 23 November 2016 Resolved
Vessel needs to get underway for in water inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 December 2016
Resolved 30 January 2017
Resolution: Underway inspection conducted.
Fire Fighting › Fire Pumps › Arrangement
Issued 23 November 2016 Resolved
Fire pump had new piping installed and needs to be operated.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 December 2016
Resolved 30 January 2017
Resolution: Fire pump successfully operated.
Engineering › Fuel Oil Service System › Piping
Issued 28 April 2016 Resolved
Vessel's port generator was spraying fuel out of the injector. Repair fuel leak prior to using port generator.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 11 May 2016
Resolution: Generator fuel leak repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 April 2016 Resolved
The COI was posted in the wheelhouse where passengers are not allowed. Post all pages of the COI in a conspicuous place where observation is likely by passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: COI posted on outside of the wheelhouse, visible from within the 2nd deck.
Documentation › Logs/Records › Logbook (official)
Issued 28 April 2016 Resolved
Vessel had no daily logs indicating the captain checked steering, communications, propulsion control, whistle, etc. Create a log or checklist and check each day onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Daily logs and checklist created and maintained on board vessel.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 28 April 2016 Resolved
The smoke detectors did not have the UL 217 or "for recreational vehicles" on the unit. Prove detectors meet requirements or replace with approved ones.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: UL217 approved smoke detectors installed and verified.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 April 2016 Resolved
The breaker box in the wheelhouse did not have a latch. Install a latch.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Latch installed on breaker box in wheelhouse.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2016 Resolved
The AC unit wiring on the upper deck was spliced using wiring nuts. Properly splice wires and enclose in a junction box.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Wires properly spaces and enclosed within junction box.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 April 2016 Resolved
A light fixture on the upper deck was missing its globe over the light bulb. Replace cover to protect bulb.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Light fixture installed.
Engineering › Bilge Water Management System › Not Operational
Issued 28 April 2016 Resolved
The visual indicator for the automatic bilge pump operation was not working. Fix or replace visual indicator.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Visual indicator for automatic bilge pump operation repaired and operational.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2016 Resolved
Wiring in the pantry area, galley, tank room, engine room, front storage area, and bow was not properly supported. Properly support all wiring with metal brackets at least every 24 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Wiring properly installed with metal brackets spaced every 24 inches.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 April 2016 Resolved
The outlet boxes in the engine room and fuel tank spaces did not have watertight covers over the outlets. Replace with ones that have covers/are watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Covers installed on outlet boxes in spaces.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 28 April 2016 Resolved
Vessel had grounding wires in the pantry space and fuel tank space that were either not supported and/or not attached properly. Remove if unnecessary or reattach as designed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Grounding wires reattached.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 April 2016 Resolved
The doors to the fridge were not latch-able. Install a latch to doors.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Latch added to refridgerator doors.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 28 April 2016 Resolved
Additional microwave and other items in the galley were not secured in place. Secure all items to make them safe for sea.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Microwave and other items secured in place.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 28 April 2016 Resolved
The exhaust support in the pantry area was broken. Properly re-attach the support.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Exhaust support re-attached.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2016 Resolved
Vessel had three cut/dead-end wires in the fuel tank space. Remove or cap and enclose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Dead-end wires removed.
Engineering › Pressure Vessel › Relief Valve
Issued 28 April 2016 Resolved
The pressure relief valve on the water heater was set at 150 PSI. Replace with a relief valve set at 100 PSI as discussed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 26 July 2016
Resolution: Provided proper relief valve.
Engineering › Pressure Vessel › Support
Issued 28 April 2016 Resolved
An additional pressure tank for the toilet facilities was not secured in place and leaking. Secure in place and repair leaking fitting.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Pressure tank secured and repaired.
Engineering › Fuel Oil Service System › Piping
Issued 28 April 2016 Resolved
The fuel tank vent lines on the port and starboard side were not double clamped. Add additional clamps on each end of the flexible piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Fuel tank vent lines double clamped.
Stability › Watertight Integrity › Coaming
Issued 28 April 2016 Resolved
The hatch to the rudder room was not watertight. Either make the hatch watertight or add a 6 inch coaming to the bottom of the door frame where the hatch is located.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: 6-inch coaming added to the bottom of the door frame where hatch is located.
Fire Fighting › Fire Main › Material
Issued 28 April 2016 Resolved
Fire main piping is not all metallic. Replace piping with metallic materials by next dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 23 November 2016

Casualty record · 3

24 August 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6795245
28 October 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7347589
20 October 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7830833
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.