← All vessels
TANKER II
Tank Barge · Barge class · Built 1960s · USCG Great Lakes District (CGD-GL) · Other hulls named TANKER II
TANKER II is a 1964 tank barge. The Coast Guard has recorded 57 inspections since 1986, most recently in December 2014, along with 24 deficiencies.
Records from 1986 to 2014. Most recent: inspection, 24 December 2014.
- Built
- 1964
- Last inspected
- 24 December 2014
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
295135
44719
Flag
UNITED STATES
—
Maury page id
psix-44719
Inspections, by type
…with no type recorded13
Years with a record
27 calendar years (1986–2014)
The 57 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it60 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 57
24 December 2014
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5043882
7 November 2014
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 5019608
23 October 2014
Drydock Extension · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5011320
23 September 2014
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 4990105
9 July 2014
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4916597
10 June 2014
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4892456
5 September 2012
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4432644
8 August 2012
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4410820
31 January 2011
Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3936270
7 May 2010
COI Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3733292
2 October 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3337745
25 September 2008
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3336408
13 February 2008
Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3146732
11 February 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3148067
10 January 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3127940
21 August 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3048416
11 April 2007
Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2905958
19 October 2006
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2810644
27 September 2006
Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2788014
24 September 2005
COI Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2481841
18 July 2005
Administrative Inspection
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2431274
21 October 2004
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2225432
1 October 2004
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2213222
13 December 2003
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1964534
5 November 2002
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1707072
24 May 2002
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1620640
2 October 2001
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1467341
21 September 2000
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1459633
28 September 1999
Re-Inspection · Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1408373
28 July 1999
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 776539
30 September 1998
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1455637
2 December 1997
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 777829
21 May 1997
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1103079
30 September 1996
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 496175
30 September 1996
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1145133
3 May 1996
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1083814
19 October 1995
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1181409
24 July 1995
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1190567
28 April 1995
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1174074
14 February 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 841755
29 September 1994
COI Inspection · Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 863339
7 February 1994
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 851896
9 November 1993
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 362603
9 November 1993
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1158572
10 August 1993
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 518394
22 May 1993
Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 516056
22 May 1993
Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 660541
22 May 1993
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 660542
20 October 1992
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 951911
21 April 1992
Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 643796
16 April 1992
Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 468212
18 October 1991
Hull Examination · Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 936251
31 October 1990
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1235747
30 November 1989
Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1238866
2 November 1988
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1350493
6 October 1987
Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1016784
19 September 1986
COI Inspection · Credit Drydock
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1002378
Deficiency record · 24
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 June 2014
Resolved
Make electrical systems safe for hazardous locations.
Deck/Cargo › Holds/Tanks › Hatch
Issued 10 June 2014
Resolved
Make hatch watertight to No. 3 cargo tank.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 June 2014
Resolved
Mark deck cargo piping with the word "tested" and the date of the most recent hydrostatic testing. The test pressure may not be marked on the piping.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 8 August 2012
Resolved
Repair flame screens for ullages on #2 and #4 cargo tanks. 2 of 4 available screens require repairs.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 August 2012
Resolved
Provide record of most recent annual calibration of cargo pump pressure gauge.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 August 2012
Resolved
Provide record of most recent annual test of cargo pump relief valve.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2010
Resolved
Install proper lamps of proper wattage in all navigation lights to comply with colregs and 2 mile range per inland navigaiton rules.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 September 2008
Resolved
Provide proof of Hydrostatic testing of the Cargo pump header and hose. Test must be conducted at 1.5 times MAWP.
MAWP established as 70 psi.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 January 2008
Resolved
33 C.F.R. 1070 (b)(1) The owner or operator of a vessel must submit the entire plan to the Coast Guard for re-approval 6 months before the end of the approval period identified by subpart 155.1060(c). The VRP Control #00302 for TANKER II is due to expire 2/22/2008. To date, no resubmission has been received at by the USCG VRP Program.
Construction/Loadline › Hull › Hull Plating
Issued 21 August 2007
Resolved
Provide proof of periodic gauging including section modulus calculations required bb 46 CFR 31.10-21a. See MISLE Act. 2810644 for details.
Construction/Loadline › Hull › Hull Plating
Issued 19 October 2006
Resolved
Provide proof of Periodic Gauging of barge to include Engineering Analysis in accordance with 46 CFR 31.10.21a.
Personnel › Training › Watchkeeping
Issued 19 October 2006
Resolved
Conduct training of barge arresting gear per 33 CFR 155.230(d)(iii).
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 19 October 2006
Resolved
Obtain all spill containment gear to be kept onboard barge per 33 CFR 155.210.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 24 September 2005
Resolved
Vessel is required to have a valid COFR. Provide a valid COFR. Vessel shall not leave the dock until this item is cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 September 2005
Resolved
Replace clamp type fittings for connection to battery with a type that can be secured with the wing nut fittings on the battery terminals.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 24 September 2005
Resolved
Replace the damaged flame screen on the gauge opening (ullage) with a new screen.
Documentation › Certificates/Documents › Stability Letter
Issued 24 September 2005
Resolved
Provide a copy of the Stability letter and keep it with the COI.
Documentation
Issued 21 September 2000
Resolved
PRIOR TO TRANSFERRING CARGO PROVIDE COPY OF USCG APPROVAL LETTER FOR VESSELRESPONSE PLAN, BEFORE THE COMPLIANCE DATE.
Lifesaving
Issued 30 September 1998
Resolved
CONDUCT PERIODIC BENZENE EXPOSURE MONITORING BETWEEN JULY 1, 1999 AND AUGUST 31, 1999 AS REQUIRED UNDER 46 CFR PART 197.540(C), TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR BEFORE THE COMPLIANCE DATE.
Deck/Cargo
Issued 19 October 1995
Resolved
Provide emergency tow capability with the same characteristics of the primary tow line, in accordance with 33 CFR 155.230.
Deck/Cargo
Issued 14 February 1995
Resolved
Provide benzene monitoring records from previous 2 years to [name withheld], [name withheld] monitoring has not been accomplished, begin initial exposure monitoring this spring, and provide report to the OCMI after completion.
Documentation
Issued 14 February 1995
Resolved
Provide documentation of damage stability information required by 33 CFR 155.240, or submit an exemption request letter to Commandant, via [name withheld] prior to commencing operations in the spring.
Documentation
Issued 14 February 1995
Resolved
Provide a copy of vessel response plan approval letter, or authorization letter from Commandant (G-MEP), to [name withheld], MI. Do not store, handle, or transport oil on the navigable waters of the U.S. until this requirement is satisfied.
Deck/Cargo
Issued 9 November 1993
Resolved
Calibrate cargo pump pressure gauge in accordance with 33 CFR 156.170.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.