MAURY USCG vessel records
← All vessels

TANKER II

Built
1964
Last inspected
24 December 2014
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 24 December 2014
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1986–2014)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-44719

Documentation record

Tonnage as PSIX records it60 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 56 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 56

24 December 2014 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5043882
7 November 2014 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 5019608
23 October 2014 Drydock Extension · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5011320
23 September 2014 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 4990105
9 July 2014 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4916597
10 June 2014 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4892456
5 September 2012 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4432644
8 August 2012 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4410820
7 May 2010 COI Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3733292
2 October 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3337745
25 September 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3336408
13 February 2008 Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3146732
11 February 2008 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3148067
10 January 2008 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3127940
21 August 2007 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3048416
11 April 2007 Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2905958
19 October 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2810644
27 September 2006 Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2788014
24 September 2005 COI Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2481841
18 July 2005 Administrative Inspection
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2431274
21 October 2004 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2225432
1 October 2004 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2213222
13 December 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1964534
5 November 2002 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1707072
24 May 2002 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1620640
2 October 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1467341
21 September 2000 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1459633
28 September 1999 Re-Inspection · Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1408373
28 July 1999 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 776539
30 September 1998 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1455637
2 December 1997 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 777829
21 May 1997 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1103079
30 September 1996 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 496175
30 September 1996 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1145133
3 May 1996 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1083814
19 October 1995 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1181409
24 July 1995 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1190567
28 April 1995 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1174074
14 February 1995 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 841755
29 September 1994 Hull Examination · COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 863339
7 February 1994 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 851896
9 November 1993 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 362603
9 November 1993 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1158572
10 August 1993 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 518394
22 May 1993 Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 516056
22 May 1993 Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 660541
22 May 1993 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 660542
20 October 1992 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 951911
21 April 1992 Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 643796
16 April 1992 Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 468212
18 October 1991 Hull Examination · Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 936251
31 October 1990 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1235747
30 November 1989 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1238866
2 November 1988 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1350493
6 October 1987 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1016784
19 September 1986 Credit Drydock · COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1002378

Deficiency record · 24

Electrical › Electric Supply System (service) › Battery Installation
Issued 10 June 2014 Resolved
Make electrical systems safe for hazardous locations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2014
Resolved 9 July 2014
Deck/Cargo › Holds/Tanks › Hatch
Issued 10 June 2014 Resolved
Make hatch watertight to No. 3 cargo tank.
Condition: Improper/Lack of Maintenance
Due 10 July 2014
Resolved 9 July 2014
Resolution: new gaskets installed and dogs adjusted by owner per digital images of gasket and chalk test.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 June 2014 Resolved
Mark deck cargo piping with the word "tested" and the date of the most recent hydrostatic testing. The test pressure may not be marked on the piping.
Condition: Improper/Lack of Maintenance
Due 10 July 2014
Resolved 9 July 2014
Resolution: Per digital images of properly marked deck cargo piping.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 8 August 2012 Resolved
Repair flame screens for ullages on #2 and #4 cargo tanks. 2 of 4 available screens require repairs.
Condition: Improper/Lack of Maintenance
Due 8 September 2012
Resolved 4 September 2012
Resolution: Received digital pictures of renewed screens.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 August 2012 Resolved
Provide record of most recent annual calibration of cargo pump pressure gauge.
Condition: Improper/Lack of Maintenance
Due 8 September 2012
Resolved 13 August 2012
Resolution: Sighted owner''s faxed report showing last calibration was 26MAR2012.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 August 2012 Resolved
Provide record of most recent annual test of cargo pump relief valve.
Condition: Improper/Lack of Maintenance
Due 8 September 2012
Resolved 4 September 2012
Resolution: Received digital image via email
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2010 Resolved
Install proper lamps of proper wattage in all navigation lights to comply with colregs and 2 mile range per inland navigaiton rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2011
Resolved 19 May 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 September 2008 Resolved
Provide proof of Hydrostatic testing of the Cargo pump header and hose. Test must be conducted at 1.5 times MAWP. MAWP established as 70 psi.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2008
Resolution: Recieved proof by faxed document signed by lic. mariner.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 January 2008 Resolved
33 C.F.R. 1070 (b)(1) The owner or operator of a vessel must submit the entire plan to the Coast Guard for re-approval 6 months before the end of the approval period identified by subpart 155.1060(c). The VRP Control #00302 for TANKER II is due to expire 2/22/2008. To date, no resubmission has been received at by the USCG VRP Program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 September 2008
Resolved 22 May 2008
Resolution: The 5 year resubmission has been reviewed. The TANKER II''s VRP is under review.
Construction/Loadline › Hull › Hull Plating
Issued 21 August 2007 Resolved
Provide proof of periodic gauging including section modulus calculations required bb 46 CFR 31.10-21a. See MISLE Act. 2810644 for details.
Action required: 705 - Other - as specified
Due 23 March 2008
Resolved 9 July 2008
Construction/Loadline › Hull › Hull Plating
Issued 19 October 2006 Resolved
Provide proof of Periodic Gauging of barge to include Engineering Analysis in accordance with 46 CFR 31.10.21a.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 1 March 2008
Personnel › Training › Watchkeeping
Issued 19 October 2006 Resolved
Conduct training of barge arresting gear per 33 CFR 155.230(d)(iii).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 21 August 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 19 October 2006 Resolved
Obtain all spill containment gear to be kept onboard barge per 33 CFR 155.210.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 21 August 2007
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 24 September 2005 Resolved
Vessel is required to have a valid COFR. Provide a valid COFR. Vessel shall not leave the dock until this item is cleared.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2006
Resolution: Per OCMI inspection report, Cleared by [name withheld]. 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 September 2005 Resolved
Replace clamp type fittings for connection to battery with a type that can be secured with the wing nut fittings on the battery terminals.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2005
Resolved 24 September 2005
Resolution: Per OCMI inspection report, Cleared by [name withheld]. 2005
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 24 September 2005 Resolved
Replace the damaged flame screen on the gauge opening (ullage) with a new screen.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2006
Resolution: Per OCMI inspection report, Cleared by [name withheld]. 2005
Documentation › Certificates/Documents › Stability Letter
Issued 24 September 2005 Resolved
Provide a copy of the Stability letter and keep it with the COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2005
Resolution: Letter was located at the owner''s house.
Documentation
Issued 21 September 2000 Resolved
PRIOR TO TRANSFERRING CARGO PROVIDE COPY OF USCG APPROVAL LETTER FOR VESSELRESPONSE PLAN, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 September 2000
Resolved 25 September 2000
Lifesaving
Issued 30 September 1998 Resolved
CONDUCT PERIODIC BENZENE EXPOSURE MONITORING BETWEEN JULY 1, 1999 AND AUGUST 31, 1999 AS REQUIRED UNDER 46 CFR PART 197.540(C), TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 30 September 1998
Resolved 30 September 1998
Deck/Cargo
Issued 19 October 1995 Resolved
Provide emergency tow capability with the same characteristics of the primary tow line, in accordance with 33 CFR 155.230.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Deck/Cargo
Issued 14 February 1995 Resolved
Provide benzene monitoring records from previous 2 years to [name withheld], [name withheld] monitoring has not been accomplished, begin initial exposure monitoring this spring, and provide report to the OCMI after completion.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Documentation
Issued 14 February 1995 Resolved
Provide documentation of damage stability information required by 33 CFR 155.240, or submit an exemption request letter to Commandant, via [name withheld] prior to commencing operations in the spring.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Documentation
Issued 14 February 1995 Resolved
Provide a copy of vessel response plan approval letter, or authorization letter from Commandant (G-MEP), to [name withheld], MI. Do not store, handle, or transport oil on the navigable waters of the U.S. until this requirement is satisfied.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Deck/Cargo
Issued 9 November 1993 Resolved
Calibrate cargo pump pressure gauge in accordance with 33 CFR 156.170.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993

Ownership record