SHENANDOAH

SHENANDOAH is a 1964 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1985, most recently in April 2026, along with 151 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2015.

Records from 1985 to 2026. Most recent: inspection, 15 April 2026.

Built
1964
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WU3059
Flag
UNITED STATES
367132480
Maury page id
psix-44727

Inspections, by type

…with no type recorded9
…past their stated due date1
Years with a record 40 calendar years (1985–2026)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)99.5 ft × 23.6 ft × 7.0 ft
Registered tonnagegross 85 / net 85
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARVEY F. GAMAGE SHIPBLD · SOUTH BRISTOL, ME, UNITED STATES · built 1964
Hull materialWood
PropulsionSail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portVINEYARD HAVEN, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Regulatory (Subpart C or D), Gross Ton
85 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK4809MMSI 367132480 · active · compulsorily equipped · granted 15 September 2018, expires 15 September 2028
WU3059MMSI 367301750 · expired · compulsorily equipped · granted 10 July 2007, cancelled 16 September 2017
WDD3514MMSI 367132480 · cancelled · compulsorily equipped · granted 1 August 2006, cancelled 1 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 94

15 April 2026 Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8350598
16 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8234606
28 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8196795
20 May 2025 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8123205
1 August 2024 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7971382
31 July 2024 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7971342
11 September 2023 In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7787537
26 June 2023 Plan Review "T" Boat
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7724074
31 March 2023 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7629015
20 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7560410
27 April 2022 Deficiency Check · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7439302
23 September 2021 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7317896
6 July 2021 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7247173
24 November 2020 Deficiency Check · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7101433
13 August 2020 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7031745
3 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6827675
10 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808147
15 July 2019 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6746064
28 May 2019 Drydock Exam · Deficiency Check · In-Service Inspection · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6696722
11 September 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6534911
7 November 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6302659
8 September 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6256979
9 June 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6166556
5 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6139915
21 February 2017 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6091726
7 September 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5999036
4 September 2015 Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5235110
23 July 2015 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5193641
23 July 2015 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5193642
14 August 2014 Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4954414
25 June 2012 Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4359548
2 December 2011 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4200469
4 August 2011 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4104841
25 March 2010 Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3702823
10 November 2008 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3362008
14 July 2008 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3267618
12 June 2008 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3233565
13 December 2007 Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3115616
9 July 2007 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2959419
2 May 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2896648
4 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2735979
2 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2733619
31 July 2006 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2659868
31 May 2006 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2666598
27 June 2005 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2404495
2 June 2005 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2349741
7 June 2004 Administrative Inspection · COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2088699
11 August 2003 Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1873288
14 July 2003 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1834117
13 May 2003 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1768036
5 February 2003 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1740326
8 July 2002 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1646050
26 April 2002 Administrative Inspection
Administrative · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1609748
3 April 2002 Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1600364
15 June 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1415633
15 June 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1459755
14 March 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1060467
16 June 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 823701
14 June 1999 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1369322
18 May 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1444174
13 July 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 798065
4 August 1997 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 782072
31 July 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 22362
23 June 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1121096
28 May 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1109119
17 June 1996 Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1089829
17 June 1996 Plan Review "T" Boat
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1248687
9 May 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1083230
27 June 1995 Plan Review "T" Boat
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1081878
26 June 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 873873
24 May 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1186737
27 June 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1389868
19 May 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 860936
28 June 1993 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1362797
12 May 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1401716
24 August 1992 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 953225
29 June 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 943356
19 May 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1267818
21 June 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1227846
16 May 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 907633
1 July 1990 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1221139
31 May 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1233299
30 June 1989 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 898553
4 May 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1200288
21 September 1988 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1352281
18 July 1988 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1032078
16 June 1987 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1000919
16 June 1987 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1313594
15 May 1987 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1331638
17 June 1986 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 996956
16 May 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1302738
8 July 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 983840
21 May 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1291391
13 May 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1291216

Deficiency record · 151

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 June 2025 No resolution recorded
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. Temporary repairs to main mast boom have been made with epoxy. Provide detailed clothespin scarf repair proposal to local OCMI and make permanent repairs to the main mast boom prior to 31May2026.
Action required: 705 - Other - as specified
Due 31 May 2026 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 August 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The visual alarm was operational but not the audible alarm. Make permanent repairs to the bilge alarm system.46CFR182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2024
Resolved 27 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 06 life jackets were not in serviceable condition. Passenger count reduced to 37 passengers until replacement jackets are aboard and marked with the vessel's name.46CFR180.71(a)
Action required: 705 - Other - as specified
Resolved 5 August 2024
Resolution: Pictures provided
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Vessel's fire extinguishers were last serviced in March of 2023. Provide proof of portable fire extinguisher servicing prior to carrying passengers.46CFR176.810(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2024
Resolution: Owner sent vessels of all portable exinguishers tagged from inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 July 2024 Resolved
The regulations in this chapter concerning inspecting and certificating vessels are applicable to vessels (including motorboats) either as indicated in the following table 2.01-7(a) or, if the vessel is a towing vessel, as provided in paragraph (b) of this section. Vessels previously issued COI expired on 15JUL2024. Vessel has been operating with passengers, meeting definitions of the cited CFR, from 16JUL24 to 31JUL24. Vessel to cease operations with 7 or more passengers immediately and conduct COI renewal. 46CFR 2.01-7
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2024
Resolved 1 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is required 43 adult life jackets. 04 life jackets were not serviceable. Passenger count is reduced to 39 adults until 04 new life jackets are on board and labeled.46CFR180.71(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2023 Resolved
Life ring on the stern was deteriorated and not serviceable. Replace life ring.46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2023
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 11 September 2023 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Wire penetrations through the #3 watertight bulkhead are not water tight. Make wire penetrations water tight. 46CFR179.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2023
Resolution: Received an email with photos of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2023 Resolved
Electrical equipment on a vessel must be installed and maintained. Light in forward cabin is loose and hanging from the ceiling. Re-secure light fixture to ceiling. 46CFR183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2023 Resolved
Wiring must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support, except that on vessels of not more than 19.8 meters (65 feet) in length,installations in accordance with paragraph 14.h of ABYC E–8 and paragraph 15.h of ABYC E–9 (both incorporated by reference; see 46 CFR 175.600) are acceptable as meeting the requirements of this section.46CFR183.340(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 September 2023 Resolved
Lower mast loop was cracked on forward main mast. Replace mast loop. A temp repair is authorized until a new loop can be obtained.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2023
Resolution: Received photo of repair
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2023 Resolved
Temporary repairs made, make permanent repairs to 3rd plank down from the main deck, port side, 3 stanchions forward of the aft fairlead prior to next credit drydock.
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 27 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 September 2022 Resolved
Vessel has a pass through galley window located in the watertight bulkhead between the galley and dinning area. The glass in the watertight window is shattered and not watertight.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 17 August 2022 Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. Submit detailed plans for your proposal to include general arrangement/locations and bill of materials for the installation to include cable sizes/length for plan approval and install the system prior to 30Sep2022.
Action required: 705 - Other - as specified
Due 30 September 2022
Resolved 10 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 27 April 2022 Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. The monitoring device must ensure the wakefulness of the crew in the event that the watchman is unresponsive; Remain operable during the nighttime watch; and Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Submit plans to the OCMI by 27May2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 27 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 August 2020 Resolved
COVID19 LAYUP; CONDUCT ANNUAL INSPECTION PRIOR TO RESUMING PASSENGER SERVICE
Action required: 705 - Other - as specified
Due 15 October 2020
Resolved 6 July 2021
Resolution: Annual Inspection has been completed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2019 Resolved
DATE AND GENERAL DESCRIPTION OF CREW TRAINING (QUARTERLY AND PRIOR TO ASSUMING DUTIES) NOT DOCUMENTED/LOGGED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 6 July 2021
Resolution: Drill log has been filled out.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2019 Resolved
DATE AND GENERAL DESCRIPTION OF ABANDONSHIP OR FIREFIGHTING DRILL REQUIRED A MIN OF QUARTERLY NOT DOCUMENTED/LOGGED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 6 July 2021
Resolution: Drill log has been filled out as per Regualtaioons.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2019 Resolved
VOYAGE PLAN FOR OVERNIGHT VOYAGES MISSING GEOGRAPHIC LOCATION(S)/BOUNDARIES OF VOYAGE, OR COMMUNICATION PLAN.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 6 July 2021
Resolution: Voyage plan is availbe for review.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 September 2019 Resolved
ALL ESCAPE HATCHES/EXITS MUST BE CLEARLY MARKED MIN 2" LETTERING ON EACH SIDE. NO ESCAPE HATCHES ARE MARKED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 6 July 2021
Resolution: Means of escape are marked.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 September 2019 Resolved
THE MASTER SHALL TEST STEERING, COMMUNICATION EQUIPMENT, ETC... DAILY. NO DAILY INSPECTIONS/EQUIPMENT FUNCTION TEST DOCUMENTED OR LOGGED, PA SYSTEM NOT OPERATIONAL.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2021
Resolution: Captain has log for daily checks.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 September 2019 Resolved
ON A VOYAGE OF OVER 24 HOURS PASSENGERS SHALL BE REQUESTED TO DON LIFE JACKETS AND GO TO ASSIGNED EMBARKATION STATIONS. OVERNIGHT PASSENGER ORIENTATION DOES NOT SPECIFY DONNING OR DEMONSTRATION OF LIFEJACKETS AT EMBARKATION STATION.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 6 July 2021
Resolution: This has been updated
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2019 Resolved
FLEXIBLE OR PORTABLE CORDS CANNOT BE USED FOR PERMANENTLY INSTALLED WIRING. (02)PLUGS IN GENERATOR BOX WITH CABLE AND CORD APPEAR TO BE IN PLACE OF PERMANENTLY INSTALLED WIRING. IDENTIFY PURPOSE OF PLUGS; HARD WIRE IF REQUIRED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 28 June 2021
Resolution: Verified on board
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2019 Resolved
OUTLET BOXES FOR USE IN DAMP LOCATIONS SHALL BE WATER--TIGHT. OUTLET BOX IN "ON DECK" GENERATOR ENCLOSURE SEVERELY CORRODED, BROKEN OFF ITS MOUNT, LAYING IN OIL/ WATER MIX, ON ITS SIDE. ELECTRICAL HAZARD, FIRE HAZARD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: verified on board
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2019 Resolved
ALL WIRING SHALL BE SUITABLE FOR MARINE SERVICE. THE OUTLET BOX IN GENERATOR ENCLOSURE THAT IS ON ITS MOUNT(NOT OUTLET MENTIONED ABOVE), IS WIRED IN REVERSE OF OTHERS, NEUTRAL IS HOT. ELECTRICAL HAZARD/FIRE HAZARD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: verfied on board
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 July 2019 Resolved
02 valves allowing water ingress into vessel in aft cabin. valves must be capped.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2019
Resolved 16 July 2019
Resolution: Vessels appropriate capped w/ brass fittings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2019 Resolved
Grab lines on 02 life ring buoys are dry rotted and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2021
Resolution: Grab lines have been replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 July 2019 Resolved
Numerous items in the first aid kit are expired. Replace IAW 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2021
Resolution: First aid kit has been updated.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 July 2019 Resolved
Vessel has application and reciept for payment for a new COD, but it has not arrived yet. Ensure valid Certificate of Documentation is onboard the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 15 July 2019 Resolved
Vessel does not have alcohol swabs onboard for post-casualty testing, and operates more than 2 hours from shore.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2021
Resolution: Vessel has new swabs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2019 Resolved
On the port side aft, plank # 17 is rotted and requires replacement at the hood end. Temp repairs made to the plank 6/17/2019. Changed due date to 10/1/2019.
Action required: 705 - Other - as specified
Due 1 October 2019
Resolved 28 June 2021
Resolution: renewed at 2020-21 dry dock period
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2019 Resolved
On the starboard side aft IWO the transom, the hood ends of 6 planks (# 19-25) are rotted and require replacement. Temp repairs made to the planks 6/17/2019. Changed due date to 10/1/2019.
Action required: 705 - Other - as specified
Due 1 October 2019
Resolved 28 June 2021
Resolution: renewed over 2020-21 dry dock period
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2019 Resolved
On the starboard side aft, planks #33 and 34 are rotted and require replacement at the hood ends (at the chine). Temp repairs made to the planks 6/17/2019. Changed due date to 10/1/2019.
Action required: 705 - Other - as specified
Due 1 October 2019
Resolved 28 June 2021
Resolution: renewed at 2020-21 dry dock period
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 May 2019 Resolved
Replace the wasted elbows in the sewage system discharge line just before the sea valve port and starboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2019
Resolved 17 June 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2019 Resolved
Prior to carrying passengers and after launching make the vessel available for an internal structural inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2019
Resolved 18 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 September 2018 Resolved
Vessel's FCC Safety Radio Certificate is expired. Renew. Vessel restricted to 1,000 feet from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2018
Resolved 14 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 September 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2018
Resolved 26 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2018 Resolved
Vessel's waterlight batteries are all expired. Repalce with new batteries for 05 total waterlights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2018
Resolved 17 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2018 Resolved
Relabel lifejackets with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2018
Resolved 17 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 September 2018 Resolved
Relabel lifefloats with vessel's name. The vessel's name cannot be read.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2018
Resolved 2 July 2019
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 September 2018 Resolved
Provide servicing report for all portable fire extinguishers. Portables are due for annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2018
Resolved 14 June 2019
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 8 September 2017 Resolved
AVH01: Designate a hazmat locker for hazardous materials.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: This was corrected.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 September 2017 Resolved
AVH02: Replace 20 lifejackets with type 1.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 10 October 2018
Resolution: Vessel replaced 20 Type I Adult lifejackets.
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 September 2017 Resolved
AVH03: Repair port side deck seem.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: Vessel repaired port side deck seam during 2018 dry dock.
Lifesaving › Lifebuoys › Serviceable
Issued 8 September 2017 Resolved
AVH04: Replace all ring buoys, line, lights and corrosion clips.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: Vessel replaced all lifebouys with corrosion resistant clips.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 September 2017 Resolved
AVH05: Replace hydro for EPIRB & provide documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: Vessel replaced hydrostatic release for EPIRB.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 September 2017 Resolved
AVH06: Replace light float battery in light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: Vessel replaced light.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 September 2017 Resolved
AVH07: Provide Coast Guard nav rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: Vessel provided CG nav rules.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 September 2017 Resolved
AVH08: Develop life saving equipment maintenance record.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 14 June 2019
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 September 2017 Resolved
AVH09: replace bilge alarm light #3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: Vessel repaired #3 bilge alarm light.
Operations/Management › Passenger Operations › Safety Orientation
Issued 8 September 2017 Resolved
AVH10: Develop a voyage plan when accomodating overnight passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: Vessel provided voyage plan for overnight excursions.
Fire Fighting › Fire Hoses › Material
Issued 8 September 2017 Resolved
AVH11: Install UL19 approved fire hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 September 2018
Resolution: Vessel provided a new UL19 fire hose.
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 9 June 2017 Resolved
Outer Bobstay chain links worn at water line from anchor / mooring chain chafe 9 to 10 links from bow connection to dolphin striker.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 11 September 2018
Resolution: Vessel repaired this problem.
Sail Rigging › Running Rigging › Shackles
Issued 7 September 2016 Resolved
AVH01. Vessel does not have a preventative maintenance plan (PMP) as per NVIC 02-16. Provide pmp to USCG.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 7 November 2017
Resolution: Vessel does have a PMP and it is a working on process.
Sail Rigging › Sails › Correct Sail Area of Record
Issued 7 September 2016 Resolved
AVH02. Vessel does not have a current sail plan. Provide a current sail plan to the USCG.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 10 May 2017
Resolution: Vessel rep proivided sail plan and it has been uploaded into this case
Fire Fighting › Fire Hoses › Condition
Issued 7 September 2016 Resolved
AVH03: Vessels fire hose is not UL19 approved. Provide an approved fire hose.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 10 May 2017
Resolution: A ul 19 hose has been installed.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 7 September 2016 Resolved
AVH04: Anchor ratchet for the lowering and raising the anchor shackle are severely wasted . Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 11 September 2018
Resolution: Vessel repaired shackle was repaired.
Engineering › Fuel Oil Service System › Portable Fuel System
Issued 4 September 2015 Resolved
Gas and diesel cans on deck. Either remove cans or refer to ABYC-H25 for proper stowage and canisters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 11 September 2015
Resolution: Vessel rep removed all canisters from main deck and brought them ashore.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 September 2015 Resolved
Life jacket placards needs to be updated with proper identification.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2016
Resolved 7 September 2016
Resolution: Markings have been updated
Navigation › Piloting/Steering › Marine Charts
Issued 4 September 2015 Resolved
Charts are out of date, provide new charts.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2016
Resolved 7 September 2016
Resolution: New charts are available
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 September 2015 Resolved
Eye wash station is out of date. renew eye wash station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 11 September 2015
Resolution: Vessel rep purchased new eye wash station.
Communications › Public Address System › Amplifier
Issued 4 September 2015 Resolved
Pa system is not working properly. Make effective repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2016
Resolved 7 September 2016
Resolution: PA system works throughout the vessel
Lifesaving › Lifefloat › Paddle
Issued 4 September 2015 Resolved
Life saving equipment needs to be properly labled, raft and paddles.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2016
Resolved 7 September 2016
Resolution: Paddles have been marked correctly
Fire Fighting › Structural - B Class Divisions › Windows
Issued 4 September 2015 Resolved
Port fwd sky light is broken, repair glass.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2016
Resolved 7 September 2016
Resolution: Window has been replaced.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 4 September 2015 Resolved
Bilge alarms in all spaces are not working properly. Must do hourly rounds if U/W.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2016
Resolved 7 September 2016
Resolution: All bilge alarms work properly
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 4 September 2015 Resolved
Line holding anchor is frayed and needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 11 September 2015
Resolution: Vessel rep installed new anchor line.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 September 2015 Resolved
Mount spare Co2 canister in the galley.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2016
Resolved 7 September 2016
Resolution: Extinquisher has been mounted
Fire Fighting › Fire Hoses › Condition
Issued 4 September 2015 Resolved
mount fire hose properly to deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2016
Resolved 7 September 2016
Resolution: Fire hose has been mounted properly
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 December 2011 Resolved
Total person count reduced to 37 by 185 lb AAWPP weight ratio reduction.
Action required: 705 - Other - as specified
Due 2 December 2011
Resolved 17 October 2013
Resolution: New stability letter issued.
Lifesaving › Hand Flares › Quantity
Issued 4 August 2011 Resolved
Provide one additional flare IAW 46 CFR 180.68
Action required: 705 - Other - as specified
Due 6 August 2011
Resolved 4 August 2011
Resolution: Received receipt from Senior Deckhand for one additional flare. Deficiency cleared.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 August 2011 Resolved
Log monthly fire, man-overboard, abandon ship drills and EPIRB test IAW 46 CFR 185.520, 185.528 and 185.728
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 20 August 2012
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 4 August 2011 Resolved
Log and conduct visual inspections for EPA vessel general permit IAW EPA VGP Part 4
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 20 August 2012
Engineering › Bilge Water Management System › Manifold
Issued 10 November 2008 Resolved
PITTED HOLE(S) TWO, THRU MANIFOLD ON MANIFOLD SPOOL PIECE, INBOARD OR MANIFOLD SIDE OF GATE VALVE(S). FOREPEAK AND VOID SPACE 2.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2009
Resolved 12 June 2009
Resolution: MSFO CAPE COD TESTED ALL. CR MOBERG OVERSAW REPAIR OF FOREPEAK BRANCH.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 November 2008 Resolved
COI EXPIRED WHILE ON DRYDOCK. CONDUCT COI INSPECTION INCLUDING AFLOAT UNDERWAY UNDER SAIL, DRILLS, ISE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2009
Resolved 12 June 2009
Resolution: CLEARED BY [name withheld]
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 12 June 2008 Resolved
The state registration for the rescue boat expired this date. This must be renewed prior to getting underway with passengers.
Condition: Unknown
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Fire Fighting › Fire Patrol › Call Points
Issued 12 June 2008 Resolved
Passenger overnight accommodation spaces are found to be missing smoke detectors. Equip these cabins with detectors prior to using for overnight berthing.
Condition: Unknown
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 June 2008 Resolved
All portable fire extinguishers were found un-serviced and must be done prior to embarking on commercial operations.
Condition: Unknown
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 June 2008 Resolved
Vessel is missing retro tape on 7 Type I PFD’s and needs to procure 2 additional Type I Adult PFD’s prior to embarking passengers.
Condition: Improper/Lack of Maintenance
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Lifesaving › Lifefloat › Float-free Link
Issued 12 June 2008 Resolved
All life float weak links were found to be improperly rigged and must be corrected prior to sailing with passengers aboard.
Condition: Placed in Improper Service
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Communications › Radio Communications › EPIRB
Issued 12 June 2008 Resolved
The EPIRB is missing its hydro-static release which must be renewed prior to transiting greater than 1 NM offshore with passengers embarked.
Condition: Placed in Improper Service
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Engineering › Bilge Water Management System › Interface Detector
Issued 12 June 2008 Resolved
Bilge wells #3 and #4 were found with inoperative high level alarms which must be repaired prior to embarking passengers.
Condition: Improper/Lack of Maintenance
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 12 June 2008 Resolved
The sewerage system overboard valve was found to be un-lockable and an 835 was issued to repair same prior to engaging in commercial operations.
Condition: Placed in Improper Service
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 June 2008 Resolved
There were no current Coast Pilot or Tides and Currents tables found aboard. They must be procured and placed aboard prior to engaging in commercial operations.
Condition: Placed in Improper Service
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Lifesaving › Lifebuoys › Serviceable
Issued 12 June 2008 Resolved
A requirement for the vessel to renew all 3 of it's life-rings was not cleared from last year's exam as the vessel has still not renewed them. RE-Issued another 835 to renew same prior to commencing commercial operations this year.
Condition: Improper/Lack of Maintenance
Due 12 June 2008
Resolved 16 June 2008
Resolution: Resolved this date
Construction/Loadline › Hull › Side Shell
Issued 14 December 2007 Resolved
CONDUCT UNDERWAY SEA TRIALS WITH A COAST GUARD MARINE INSPECTOR TO ENSURE THERE ARE NO HULL LEAKS RELATED TO THE 2007/2008 DRYDOCKING. A CREDITED DRYDOCK WILL BE GRANTED UPON SUCCESSFUL SEA TRIALS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2008
Resolved 16 June 2008
Resolution: Satisfactorily completed this date
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 July 2007 Resolved
Provide a serviceable type I life jacekt for all embarked personnel prior to resuming commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2007
Resolved 16 June 2008
Resolution: Resolved this date
Lifesaving › Buoyant Apparatus › Float Free
Issued 9 July 2007 Resolved
Properly mount and equip the bouyant apparatus prior to operating greater than 1 NM offshore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2007
Resolved 16 June 2008
Resolution: Resolved this date
Lifesaving › Lifebuoys › Serviceable
Issued 9 July 2007 Resolved
Equip the vessel with servicable liferings prior to recuming commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2007
Resolved 16 June 2008
Resolution: Resolved this date
Communications › Radio Communications › EPIRB
Issued 9 July 2007 Resolved
Prior to operating greater than 1 NM offshore service the vessels EPIRB and renew the expired registration for same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2007
Resolved 16 June 2008
Resolution: Resolved this date
Construction/Loadline › Hull › Side Shell
Issued 2 May 2007 Resolved
At next credit hull exam, replace plank numbers 1,2, & 3 in way of forward mast going aft on starboard side.
Action required: 705 - Other - as specified
Resolved 22 May 2008
Construction/Loadline › Hull › Side Shell
Issued 2 May 2007 Resolved
At next credit hull exam, repair covering board on starboard side aft of forward mast.
Action required: 705 - Other - as specified
Resolved 22 May 2008
Construction/Loadline › Hull › Side Shell
Issued 2 May 2007 Resolved
At next credit hull exam, replace plank numbers 5 & 6 aft of stern mast on starboard side.
Action required: 705 - Other - as specified
Resolved 22 May 2008
Construction/Loadline › Hull › Side Shell
Issued 2 May 2007 Resolved
At next credit hull exam, replace plank numbers 4,6,7, & 8 aft of stern mast on port side.
Action required: 705 - Other - as specified
Resolved 22 May 2008
Construction/Loadline › Hull › Side Shell
Issued 2 May 2007 Resolved
At next credit hull exam, replace plank numbers 1,2,3, & 4 in way of forward mast going aft.
Action required: 705 - Other - as specified
Resolved 22 May 2008
Construction/Loadline › Hull › Side Shell
Issued 2 May 2007 Resolved
On three planks marked "fill" (starboard side), make wood graving repair unless rot extends more than ½ of the plank thickness then replace planks vice renewal.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Resolution: Isolated rot spots filled. All sat.
Lifesaving › Hand Flares › Not on Board
Issued 31 July 2006 Resolved
Prior to transiting more than 1 nm from shore procure 6 flares, 6 smokes to replace expired ones onboard and renew the expired EPIRB hydrostatic release.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 2 August 2006
Resolution: Cleared this date
Lifesaving › Lifefloat › Paddle
Issued 31 July 2006 Resolved
Procure two sets of paddles missing from the lifefloats NLT 8/4/06.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 4 August 2006
Resolution: Paddles supplied on board this date.
Lifesaving › Lifebuoys › Serviceable
Issued 31 July 2006 Resolved
All three liferings found with unserviceable retro reflective tape to be replaced with noew no later than 8/4/06.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 4 August 2006
Resolution: Corrected this date.
Documentation › Certificates/Documents › FCC SSL
Issued 31 July 2006 Resolved
No FCC operators permit aboard. Obtain valid permit NLT 8/4/06.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 2 August 2006
Resolution: Cleared this date
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 June 2005 Resolved
INSTALL FLOAT LIGHT, 2 - 4' PADDLES, 100' PAINTER WITH PROPER WEAK LINK FOR THE 2 NEW LIFE FLOATS. LABEL LIFE FLOATS WITH VESSEL NAME AND INSTALL TO BE FLOAT FREE FOR ALL LIFE FLOATS. VESSEL RESTRICTED TO NOT MORE THAN 3 MILES FROM SHORE UNTIL ALL ABOVE COMPLETED.
Action required: 705 - Other - as specified
Due 27 July 2005
Resolved 2 August 2006
Resolution: Cleared this date
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 June 2005 Resolved
REPAIR FORWARD BILGE ALARM AND LABEL BILGE ALARM PANEL CORRECTLY.
Action required: 705 - Other - as specified
Due 27 July 2005
Resolved 31 July 2006
Resolution: Tested satisfactory this date.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 June 2005 Resolved
LABEL STOWAGE LOCATION OF ALL LIFE JACKETS AND DISTRIBUTE THROUGHOUT VESSEL FOR EASY ACCESS.
Action required: 705 - Other - as specified
Due 27 July 2005
Resolved 31 July 2006
Resolution: Noted as satisfactory this date.
Lifesaving › Lifefloat › Quantity
Issued 7 June 2004 Resolved
VESSEL IS RESTRICTED TO NOT MORE THAN 3 MILES FROM SHORE UNTIL 100% LIFE FLOATS INSTALLED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2005
Resolved 27 June 2005
Resolution: LIFE FLOATS INSTALLED
Communications › Radio Communications › EPIRB
Issued 7 June 2004 Resolved
REPLACE EPIRB HYDROSTATIC RELEASE. VESSEL RESTRICTED TO NOT MORE THAN 3 MILES FROM SHORE UNTIL REPLACED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2005
Resolved 8 June 2005
Resolution: New hydro provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 June 2004 Resolved
REPAIR AUX SPACE BILGE ALARM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2005
Resolved 8 June 2005
Resolution: Tested all high level alarms sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 June 2004 Resolved
INSTALL NON-CORROSIVE CLIP FOR FLOAT LIGHT ATTACHMENT TO LIFE RING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2005
Resolved 8 June 2005
Resolution: Not required.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 June 2004 Resolved
REPAIR LIFE FLOAT WATER LIGHT PRIOR TO LEAVING MOORING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2005
Resolved 8 June 2005
Resolution: Life float waterlight provided sat.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 7 June 2004 Resolved
PROVIDE STATION BILL FOR CREW AS REQUIRED BY 46 CFR 185.514.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2005
Resolved 8 June 2005
Resolution: Station bill provided sat.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 7 June 2004 Resolved
PROVIDE ONBOARD COPIES OF DRUG TESTING PROGRAM ENROLLMENT FOR CREW.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2005
Resolved 27 June 2005
Resolution: DRUG TESTING PROGRAM DOCUMENTS PROVIDED.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 July 2003 Resolved
INSTALL CLIP AT END OF WATER LIGHT LINE CONNECTING IT TO THE LIFE RING.
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 14 July 2003
Resolution: CREW TO INSTALL CLIP.
Lifesaving
Issued 15 June 2001 Resolved
PROVE PROPER OPERATION OF BILGE HIGH LEVEL ALARM SYSTEM AS REQUIRED BY 46 CFR 182.530.
Condition: Unknown
Due 2 July 2001
Resolved 8 July 2002
Lifesaving
Issued 15 June 2001 Resolved
INSTALL 100% LIFESAVING AS REQUIRED BY 46 CFR 180.200.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Lifesaving
Issued 15 June 2001 Resolved
INSTALL CAT. 1 406 MHZ EPIRB AS REQUIRED BY 46CFR 180.64
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Documentation
Issued 17 June 1996 Resolved
CONDUCT AUDIT OF CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 17 June 1996 Resolved
POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 12 August 1996
Resolved 12 August 1996
Lifesaving
Issued 17 June 1996 Resolved
PROVIDE BRIGHT-COLORED WATERTIGHT CONTAINER MARKED WITH "DISTRESS SIGNALS" IN ONE INCH LETTERS._x001C_
Condition: Unknown
Due 12 August 1996
Resolved 12 August 1996
Navigation
Issued 17 June 1996 Resolved
POST EMERGENCY REDIO CHECKLIST.
Condition: Unknown
Due 12 August 1996
Resolved 12 August 1996
Lifesaving
Issued 17 June 1996 Resolved
PLACE REFLECTIVE TAPE ON RING BUOYS.
Condition: Unknown
Due 12 August 1996
Resolved 12 August 1996
Lifesaving
Issued 26 June 1995 Resolved
REPLACE TWO DAMAGED PFD'S.
Condition: Unknown
Due 24 July 1995
Resolved 24 July 1995
Lifesaving
Issued 26 June 1995 Resolved
PLACE VESSEL NAME ON 6 PFD'S.
Condition: Unknown
Due 24 July 1995
Resolved 24 July 1995
Lifesaving
Issued 26 June 1995 Resolved
PROPERLY RIG SEA PAINTER AND FLOAT LIGHT LANYARD.
Condition: Unknown
Due 24 July 1995
Resolved 24 July 1995
Lifesaving
Issued 27 June 1994 Resolved
REPLACE WEAKLINK FOR LIFEFLOAT ATOP CABIN TOP_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Lifesaving
Issued 27 June 1994 Resolved
PROVE COMPLIANCE WITH DRUG TESTING REQUIREMENTS OF 46 CFR 16._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Accommodation/Occupational Safety
Issued 19 May 1994 Resolved
RENEW HOSE FOR TOILET OVERBOARD DISCHARGE TO AFT STARBOARD HEAD._x001C_ _x001C_
Condition: Unknown
Due 28 June 1994
Resolved 9 August 1994
Accommodation/Occupational Safety
Issued 19 May 1994 Resolved
RENEW VENT PIPE PORT SIDE LAZARETTE.
Condition: Unknown
Due 28 June 1994
Resolved 9 August 1994
Fire Fighting
Issued 19 May 1994 Resolved
PROVE PROPER OPERATION OF BILGE/FIRE PUMP._x001C_
Condition: Unknown
Due 28 June 1994
Resolved 9 August 1994
Construction/Loadline
Issued 19 May 1994 Resolved
PUMP DRY ALL BILGE AREAS._x001C_
Condition: Unknown
Due 28 June 1994
Resolved 9 August 1994
Construction/Loadline
Issued 19 May 1994 Resolved
RENEW WATERTIGHT DOOR GASKET._x001C_
Condition: Unknown
Due 28 June 1994
Resolved 9 August 1994
Accommodation/Occupational Safety
Issued 29 June 1992 Resolved
PROVIDE A WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Accommodation/Occupational Safety
Issued 29 June 1992 Resolved
PROVIDE A MARPOL V PLACARD.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Lifesaving
Issued 29 June 1992 Resolved
CONDUCT FIRE AND BOAT DRILLS.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Fire Fighting
Issued 29 June 1992 Resolved
MOVE ONE B-I PORTABLE FIRE EXTINGUISHER TO CLOSE PROXIMITY OF THE WHEEL.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Accommodation/Occupational Safety
Issued 29 June 1992 Resolved
MAKE MSDS MEET CURRENT CG REGULATIONS OR PROVIDE A CURRENT WAIVER LETTER.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Lifesaving
Issued 29 June 1992 Resolved
STENCIL JACKETS WITH VESSEL NAME.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Lifesaving
Issued 18 July 1988 Resolved
PROVIDE TWO (02) ADDITIONAL ADULT LIFE PRESERVERS PRIOR TO CARRYING MORE THAN FORTY-ONE (41) PERSONS ON BOARD.
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Navigation
Issued 18 July 1988 Resolved
MAKE ALL KEROSENE NAVIGATIONAL LIGHTS FULLY OPERABLE PRIOR TO OPERATING VESSEL IN DARKNESS.
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Lifesaving
Issued 16 June 1987 Resolved
MAKE ALL PRIMANY LIFESAVING APPARATUS READILY RELEASABLE WITH NO COMPLICATED TIE DOWNS.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Lifesaving
Issued 16 June 1987 Resolved
FABLE ALL OARS, FIRESTATIONS AND RING BUOYS.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Fire Fighting
Issued 16 June 1987 Resolved
REPLACE FIREHOSE
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Unknown
Issued 16 June 1987 Resolved
LUBRICATE FIXED HAND PUMP ON FORWARD SECTION OF VESSEL
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Lifesaving
Issued 16 June 1987 Resolved
REPLACE POLY LINES INSIDE PORT BUOYANT APPARATUS.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Lifesaving
Issued 16 June 1987 Resolved
REPAIR DAVT FALLS GUIDE ON 2 RESCUE BOATS
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Lifesaving
Issued 16 June 1987 Resolved
REPAIR BOTTOM AND OAR ON MIDSHIPS LIFEFLOAT.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Lifesaving
Issued 16 June 1987 Resolved
REPLACE WEAK LINK ON MIDSHIPS LIFEFLOAT.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Unknown
Issued 16 June 1987 Resolved
FABLE BILGE MANIFOLD SYSTEM AND PLACE PLACARD IN THE IMMEDIATE AREA.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Construction/Loadline
Issued 16 June 1987 Resolved
REPAIR 4TH MAIN MAST HOOP FROM THE TOP.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Fire Fighting
Issued 17 June 1986 Resolved
PROVIDE SPANNER FOR FIRE STATION.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Lifesaving
Issued 17 June 1986 Resolved
REPLACE LIFELINES TO BOTH LIFEFLOATS STOWED ON MAIN DECK ALONG WITH REDOINGLASH DOWNS.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Lifesaving
Issued 17 June 1986 Resolved
PROVIDE 5 ADULT AND 1 CHILD PEF'S.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Accommodation/Occupational Safety
Issued 8 July 1985 Resolved
PROVIDE WAIVER AS REQUESTED OR PLANS FOR INSTALLATION OF COAST GUARD APPROVED MARINE SANITATION SYSTEM.
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Construction/Loadline
Issued 21 May 1985 Resolved
FORWARD BOOBY HATCH TO SALOON AND ITS PORT AND STBD HEAD SKYLIGHTS: REPLACE ROTTED AREAS IN DECK AND GRUB BEAMS AND ANCILLARY STRUCTURE.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985

Casualty record · 1

23 July 2015Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 5193642
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.