Records from 1997 to 2025. Most recent: inspection, 19 May 2025.
Documentation record
Registered dimensions (L × B × D)139.0 ft × 30.0 ft × 12.0 ft
Registered tonnagegross 98 / net 68
ITC dimensions (L × B × D)139.0 ft × 30.0 ft × 12.0 ft
ITC tonnagegross 309 / net 92
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1997
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
309 - Convention (Subpart B), Gross Ton
68 - Regulatory (Subpart C or D), Net Ton
92 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
19 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8139346
10 September 2024
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8004426
2 April 2024
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7877481
14 March 2024
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7877474
9 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6142548
11 January 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4222351
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200147
23 September 2010
Drydock Exam · Internal Structural Exam · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3855490
10 November 2008
Hull Examination · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3366289
4 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3177516
10 January 2008
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3128268
30 January 2007
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2863843
24 March 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2611363
6 April 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327596
28 December 2004
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2265629
9 February 2004
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2003115
27 January 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1993635
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976399
18 March 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1762700
3 March 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1759029
15 January 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1730636
7 February 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1483902
13 February 2001
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422014
2 February 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457744
8 February 1999
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1473380
25 March 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375346
26 June 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776287
6 June 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112430
7 February 1997
Hull Examination · Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468404
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 April 2024
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquids, the temperature of which exceeds 65.5°C (150°F), must be suitably insulated where necessary to prevent injuries. Portside exhaust discharge line not properly insulated.
46 CFR 177.970
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: Crew added lagging to exhaust pipe.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 April 2024
Resolved
When using DSC techniques, coast stations and ships must
use Maritime Mobile Service Identities (MMSI) assigned
by The Commission or its designees. MMSI not programmed
in radios.
47 CFR 80.103(b)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: Master programmed MMSI
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 2 April 2024
Resolved
Sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. Missing sea rails for stovetop.
46 CFR 184.220(e)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: Sea rails were added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2024
Resolved
All electrical equipment and circuits must be clearly marked and identified.
Any cabinet, panel, box, or other enclosure containing more than one source of power must be fitted with a sign warning persons of this condition and identifying the circuits to be disconnected. Distribution panel in engine room not accurately labeled.
46 CFR 183.220(d)
46 CFR 183.220(e)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: List was provided identifying each circuit
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 April 2024
Resolved
Portable watertight containers for distress flares and
smoke signals shall be of a bright color, and containers
shall be clearly marked ineligible contrasting letters at least 12.7 mm (0.5 inches) high: "DISTRESS SIGNALS". Distress Flare container not labeled.
46 CFR 185.614
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: Distress flare container was labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 April 2024
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Expiration date not marked.
46 CFR 185.740(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: Expiration date marked.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 2 April 2024
Resolved
A vessel which, under 178.310 of this part, complies with requirements in subchapter S of this chapter, must have stability details on a stability letter issued by the cognizant [name withheld] letter needs vessel name.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 13 May 2024
Resolution: Vessel rep contacted MSC for name change on Stability Letter, however since no modifications were made to the boat Stability Letter does not get changed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2024
Resolved
The bridge-to-bridge radiotelephone station will be inspected on vessels subject to regular inspections pursuant to the requirements of Part II and III of Title III of the Communications Act, the Safety Convention. The validity of the endorsement will be made on the appropriate document. No expiration date on certificate.
47 CFR 80.1005
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 4 April 2024
Resolution: Updated copy was emailed with exipration date.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2024
Resolved
Marine employers shall randomly select a sufficient number of covered crew members for testing during each calendar year to equal an annual rate not less than the minimum annual percentage rate for random drug testing determined by the Commandant. Employer is currently enrolled in a consortium, though unable to provide proof at the time of inspection.
46 CFR 16.230(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 4 April 2024
Resolution: Copy of consortium and results emailed.
Construction/Loadline › Structures › End Bulkhead
Issued 27 January 2004
Resolved
Aft bulkhead of aft F/W tank numerous fractures and repairs. Plate to be inserted at next drydock.
Action required: 705 - Other - as specified
Due 31 January 2005
Resolved 5 January 2005
Resolution: Significant portion of blkhd satisfactorily inserted.
Navigation
Issued 27 January 2004
Resolved
Steering pump run indicator lights at pilothouse missing, provide per 46 CFR 182.610(g)(1).
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 6 February 2004
Resolution: Provided.
Engineering
Issued 27 January 2004
Resolved
Provide proper flex hose at clutch cooling pump seachest connection per 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 6 February 2004
Resolution: Provided.
Lifesaving › Buoyant Apparatus
Issued 7 February 2002
Resolved
Wireties used for pendants made up into hanks. LEGACY COMPONENT DESC: Pendants
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2002
Resolution: Removed wireties and used light twine.
Communications › Radio Communications › EPIRB
Issued 7 February 2002
Resolved
EPIRB battery expired, unit could not be tested.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2002
Resolution: Replaced EPIRB.
Engineering › Steering Gear System
Issued 7 February 2002
Resolved
Issued 835 to have rudder angle indicator installed by 08 Feb 03 or at next drydock whichever comes first as per MORMS ACID. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2003
Resolved 31 January 2003
Resolution: Installed (fwd operating station only).
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 7 February 2002
Resolved
Ovespeed device not functional.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2002
Resolution: Replaced overspeed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 7 February 2002
Resolved
Stbd remote fuel valve shutoff broke during operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2002
Resolution: Repaired.
Construction/Loadline
Issued 26 June 1997
Resolved
INSTALL AN ESCAPE HATCH FROM ENG RM AS REQUIRED BY 46 CFR SUBCHAPTER "T" AND THE APPROVED ORIGINAL DESIGN DRAWINGS 1 AND 2 OF 150-A-30. DUE TO LOCATION OF HATCH AN ONDECK RAILING IS REQUIRED BY DRAWINGS TO PREVENT LOADING CARGO ON TOP OF HATCH.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Fire Fighting
Issued 7 February 1997
Resolved
INSTALL A FIXED EXTINGUISHING SYSTEM IN THE MACHINERY SPACE AS PER MSC APPROVED PLANS IN ACCORDANCE WITH 46 CFR 181.400(a). (NEW SUB. T)
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Fire Fighting
Issued 7 February 1997
Resolved
INSTALL A FIRE DETECTION SYSTEM IN THE MACHINERY SPACE AS PER G-MSC APPROVED PLANS IN ACCORDANCE WITH 46 CFR 181.400(c). (NEW SUB T)
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Electrical
Issued 7 February 1997
Resolved
INSTALL REMOTE START FOR THE FIRE PUMP AS REQUIRED BY 46 CFR 181.300 (e); _x001C_NEW SUB T.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997