BLUE WATER NO 2

BLUE WATER NO 2 is a 1964 mobile offshore drilling unit. The Coast Guard has recorded 13 inspections since 1980, most recently in June 1986, along with 58 deficiencies.

Records from 1980 to 1986. Most recent: inspection, 24 June 1986.

Built
1964
Last inspected
24 June 1986
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WQ4537
Flag
NETHERLANDS ANTILLES
—
Maury page id
psix-44756

Inspections, by type

…with no type recorded11
Years with a record 6 calendar years (1980–1986)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 40 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1696 - Regulatory (Subpart C or D), Gross Ton
1191 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

24 June 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1304162
9 September 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1297394
8 August 1985 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291267
2 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 980353
7 January 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976861
2 November 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 974373
16 October 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282550
20 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280735
14 June 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973680
29 October 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272283
10 September 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964837
24 July 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271773
23 July 1980 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273262

Deficiency record · 58

Electrical
Issued 8 August 1985 Resolved
MAKE EXPLOSION PROOF THE TORQUE INDICATING GUAGE ON THE DRILLER'S CONSOLE.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Documentation
Issued 8 August 1985 Resolved
UPDATE THE HAZARDOUS LOCATIONS PLAN TO SHOW THE AREAS AROUND THE PAINT LOCKER AND RESUBMIT FOR APPROVAL.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Lifesaving
Issued 8 August 1985 Resolved
PROVIDE LIFEBOAT #2 (PORT) WITH SERVICEABLE WATER AND ONE ADDITIONAL ORANGESMOKE SIGNAL FOR A TOTAL OF TWO.
Condition: Unknown
Due 30 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 8 August 1985 Resolved
RETURN THE ORIGINAL GRANDFATHERED CANISTERED LAUNCHED LIFERAFTS IN SERVICE-ABLE CONDITION OR INSTALL APPROVED DAVIT LAUNCHED LIFERAFTS IN THEIR PLACE.
Condition: Unknown
Due 14 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 August 1985 Resolved
CONNECT THE #1 LIFEBOAT STATION LIGHTING TO THE EMERGENCY LIGHTING CURCUIT AND TEST THE #3 LIFERAFT STATION LIGHTING TO ENSURE THAT IT IS ON THE EMERGENCY LIGHTING CIRCUIT.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Lifesaving
Issued 8 August 1985 Resolved
PROVIDE LIFE JACKETS WITH ADDITIONAL 28 SERVICEABLE LIGHTS AND 4 ADEQUATE RETRO-REFLECTIVE TAPE PLUS 2 ADDITIONAL SERVICEABLE LIFE JACKETS. UNTIL PROVIDED LIMIT MANNING TO 28 MEN.
Condition: Unknown
Due 30 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 8 August 1985 Resolved
IN FIREMAN'S OUTFITS HYDROSTATICALLY TEST ALL SELF-CONTAINED BREATHING APPARATUS AIR BOTTLES AND SERVICE THE 2 COMBUSTIBLE GAS/OXYGEN METERS.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Navigation
Issued 8 August 1985 Resolved
LEVEL ALL OBSTRUCTION LIGHTS AND ENSURE THAT THE LENSES ARE CLEAN.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Navigation
Issued 8 August 1985 Resolved
ADJUST THE FOG HORN TO SOUND CORRECT SIGNAL.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Lifesaving
Issued 8 August 1985 Resolved
PRIOR TO CONDUCTING DRILLING OPERATIONS CONDUCT FIRE AND ABANDON VESSEL DRILLS.
Condition: Unknown
Due 14 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 August 1985 Resolved
REPAIR OR REPLACE THE TACHOMETERS ON THE GENERATORS.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
REPAIR OR REPLACE THE BROKEN ELECTRICAL CABLES FOR THE #2 AND #3 EMD HEATERS.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
REPAIR OR REPLACE THE EMERGENCY LIGHT NEXT TO THE GENERATOR SWITCHBOARD.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
INSTALL VENTILATION PARTS ON THE OBSTRUCTION LIGHT BATTERY BOX.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
MAKE THE LINING ON THE GENERAL ALARM BATTERY BOX WATERTIGHT TO A HEIGHT OF 3".
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
PROPERLY LABEL VARIOUS EMERGENCY LIGHTS THROUGHOUT THE RIG.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Engineering
Issued 8 August 1985 Resolved
HYDROSTATICALLY TEST THE P-TANK VOLUME AIR RECEIVER TO 1 AND 1/2 MAWP, AND LABEL THIS AIR RECEIVER AND THE 2 CRANE AIR RECEIVERS WITH PROPER MANU- FACTURERS INFORMATION AND MAKE ALL 3 AVAILABLE FOR COAST GUARD STAMPING ANDNUMBERING.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
REPAIR OR REPLACE THE GENERAL ALARM BELLS IN THE MUD PUMP ROOM AND THE DRILL FLOOR, 3 TOTAL.
Condition: Unknown
Due 9 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 August 1985 Resolved
INSTALL PROPER VENTILATION AND ELECTRICAL EQUIPMENT IN THE LAUNDRY ROOM TO HAVE IT MEET THE STANDARDS OF A CLASS I, DIVISION 2, LOCATION, OR MOVE THE PAINT LOCKER, FROM ITS PRESENT LOCATION TO AN ACCEPTALBE LOCATION.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Engineering
Issued 8 August 1985 Resolved
REPAIR OR REPLACE THE RELIEF VALVES ON THE FOLLOWING TANKS: DRILL FLOOR AIR RECEIVER, #1 DRILL AIR RECEIVER, BOP CONTROL UNIT HYDRAULIC PUMP SIDE, AND INSTALL A RELIEF VALVE ON THE WATER TANK IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Deck/Cargo
Issued 8 August 1985 Resolved
STENCIL THE LIFTING CAPACITY ON THE FORK LIFT.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Deck/Cargo
Issued 8 August 1985 Resolved
RENEW THE ASBESTOS LINERS ON THE AIR TUGGER STARBOARD SIDE ONE DECK BELOW THE DRILL FLOOR AND ADJUST THE BRAKE SETTINGS ON BOTH IN THAT LOCATION.
Condition: Unknown
Due 9 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 8 August 1985 Resolved
AMEND THE OIL TRANSFER PROCEDURES TO CONTAIN A LINE DIAGRAM OF THE RIG'S OIL TRANSFER PIPING.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
INSTALL A SWITCH TO HAVE THE DRILL FLOOR DOG HOUSE AIR PURGE ALARM SOUND UPON A FAILURE OF THE VENTILATION FAN FOR THE SAME.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Deck/Cargo
Issued 8 August 1985 Resolved
INSTALL ONE 30X30 OR TWO 20X20 MESH FLAME SCREENS IN BOTH FUEL OIL TANK VENTS.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
STENCIL IN RED LETTERING THE REMOTE VENTILATION SHUTDOWN CIRCUIT BREAKERS FOR THE QUARTERS AREAS.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Engineering
Issued 8 August 1985 Resolved
REPAIR OR REMOVE THE #1 EVAPORATOR.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
INSTALL COVERS OVER THE OPEN AREAS ON THE CIRCUIT BREAKER BOX BY THE HOT WATER HEATERS.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
REMOVE OR MAKE EXPLOSIONPROOF THE FOLLOWING EQUIPMENT IN THE MUD PIT ROOM: A. THE HOSE MCCANN TELEPHONE ON THE CEMENT UNIT; B. THE 2 TELEPHONE JUNCTION BOXES ON THE STARBOARD SIDE AFT BULKHEAD.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
INSTALL EYS FITTINGS ON THE FOLLOWING EQUIPMENT IN THE MUD PIT ROOM: A. #2 CENTRIFUGAL MUD MIXING PUMP; B. THE WELDER'S EQUIPMENT POWER SUPPLY JUNCTION BOX PORT SIDE BULKHEAD; C. 2 JUNCTION BOXES, UPPER LEVEL, PORT SIDE.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
INSTALL AN EXPLOSIONPROOF CONTACTOR BOX FOR THE GENERAL ALARM, AFT MUD PIT ROOM.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 8 August 1985 Resolved
INSTALL 2 EYS FITTINGS ON THE JUNCTION BOX, FORWARD SIDE SHALESHAKER AREA.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Electrical
Issued 14 June 1984 Resolved
CORRECT FOLLOWING ELECTRICAL DEFICIENCIES ON DRILL FLOOR W/SUITABLE CLASS 1 DIV 2 EQUIP: GENERAL ALARM CONTACT & BELL; S/P PHONE; PURGE AIR SYS FOR
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
DRILLERS CONSOLE MUST MEET NFPA 496; ALARM BELL BY CONSOLE; TERMINAL BOX FOR PORT DRAWWORKS MTR; EYS FITTING ON MOTOR CONTROLLER ON STBD BHD;
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
J-BOX ON BHD PORT SIDE MISSING PLUG; J-BOX NEXT TO DOGHOUSE MISSING PLUG FOR EYE FITTING; ELECTRICAL EQUIP INSIDE DRILLERS CONSOLE NOT PURGED.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
PRIOR TO DRILLING OPERATIONS, RELOCATE RADIO ANTENNA AT LEAST 10' FROM GAS OUTLET AT THE TOP OF THE DERRICK.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
PROVIDE PROPER LENSES FOR INDICTOR LIGHTS ON BALLAST CONTROL PANEL.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE BLUE WATER NO. 2, DN295803.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
REPLACE THE MISSING GLOBES AND GUARDS FOR SEVERAL LIGHT FIXTURES IN THE ENGINE ROOM AND UNDER THE MAIN DECK.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Documentation
Issued 14 June 1984 Resolved
POST UNDER GLASS IN ACCORDANCE WITH 46 CFR 109.563 A FIRE AND SAFETY PLAN APPROVED BY THE U. S. COAST GUARD.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
PROVIDE RELIEF VALVES, SET AT OR BELOW 40 PSIG, FOR 4 P-TANKS & VOLUME TANKRELIEVING CAPACITY EACH VALVE MUST CLOSELY MATCH PUMPING CAP OF AIR COMP.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
POUR ALL EYS FITTINGS IN ALL HAZARDOUS LOCATIONS.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
REPLACE THE FOLLOWING ELECTRICAL EQUIPMENT IN RIG FLOOR DOG HOUSE WITH EQUIPMENT SUITABLE FOR CLASS 1 DIV 2 LOCATIONS: HOSE-MCCANN S/P PHONE,
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
RECEPTACLES, OUTLETS, SWITCHES, ELECTRIC HEATER, TOTCO ELECTRIC TORQUE UNIT, AIR LIMIT SWITCH, MISSING EYS FITTINGS ON ALL ELECTRIC EQUIPMENT.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Accommodation/Occupational Safety
Issued 14 June 1984 Resolved
UPON RIG'S DEPARTURE FROM SABINE PASS, PROVIDE CHAINGUARD OR RAILING FOR STAIRWAY UNDER THE MAIN DECK.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
THE HOSE MCCANN SOUND POWERED PHONE IN THE SHALE SHAKER AREA MUST BE RE- MOVED OR REPLACED WITH EXPLOSION PROOF EQUIPMENT.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
REPAIR ALL CABLES FOR CATLODIC PROTECTION SYSTEM.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
ON MAIN DECK AND CATWALK UNDER MAIN DECK STRAP UP ALL LOOSE CALBES, REMOVE ALL IN LINE SPLICES IN ELECTRICAL CABLE, & PROPERLY PACK ALL STUFFING TUBES
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
PRIOR TO INSTALLATION, HAVE ALL PURGE AIR SYSTEMS CHECKED BY U. S. COAST GUARD AS TO THE REQUIREMENTS OF NFPA 496.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
PROVIDE AND POUR EYS FITTINGS FOR MUD CLEANING EQUIPMENT RECENTLY INSTALLEDON BOARD.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
PROVIDE FIRE RESISTANT WIRE REINFORCED NON-METALLIC FLEXIBLE F/O HOSES WITHPROPER FITTINGS FOR CRANES IN ACCORDANCE WITH 46 CFR 56.60-75(C).
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
PROVIDE EYS FITTINGS FOR ALL MOTORS AND CONTROLLERS FOR DRAWWORKS BRAKE COOLING SYSTEM UNDER SUBSTRUCTURE.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
PLACE WARNING SIGN ON BOTH SIDES OF BALLAST CONTR. ROOM DOOR TO MUD PUMP ROOM STATING THAT DOOR IS TO BE KEPT CLOSED AT ALL TIMES WHILE DRILLING.
Condition: Unknown
Due 12 July 1984
Resolved 14 June 1984
Electrical
Issued 14 June 1984 Resolved
REPLACE THE FOLLOWING ELECTRICAL EQUIPMENT IN THE MUD PIT AND PUMP ROOM WITH EQUIPMENT SUITABLE FOR CLASS 1 DIV 2 LOCATIONS: EYS FITTINGS EXHAUST
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
FANS; FLOODLIGHT & BALLAST; CONTROLLER & INDICATOR FOR MUD PUMPS, INCLUDINGHORN; BLOWER FAILURE ALARMS, HOSE MCLANN S/P PHONE; GENERAL ALARM CONTACT
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
MAKER AT MUD PIT; MISSING EYS FITTING FOR GAITRONIC SYS; MISSING EYS FITTING FOR DESILTER PUMP; POWER PANEL STBD SIDE AFT; 3 POWER PANELS FWD OF
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
PITS; CATHODIC PROTECTION BOX & CONTROLLER; MISSING EYS FITTINGS ON MUD PUMP BLOWER MOTORS AND PUMP MOTORS; TERMINAL BOX FOR #2 MUD PUMP BLOWER;
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
MISSING EYS PUMP STROKE COUNTER #2 MUD PUMP; COUNTERS & LIMIT SWITCHES FOR MUD PUMPS; BHD PENETRATION STBD SIDE; ELECT OUTLET ON STBD BHD.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984

Ownership record