Records from 1981 to 2010. Most recent: inspection, 14 June 2010.
Inspection history · 51
14 June 2010
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3766529
15 July 2009
Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3535771
3 July 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3255385
10 July 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2985605
7 June 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2672932
11 April 2005
Cargo Tank Internal · MTSA Verification · Hull Examination · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2330958
15 November 2004
MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2241226
22 July 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2141302
22 June 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2107384
21 March 2003
Periodic Inspection · Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1760601
4 April 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1602249
20 April 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063027
23 March 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1387011
23 March 2000
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442969
2 February 2000
Examination of Repairs · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1388944
30 November 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 108224
17 September 1999
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034917
17 November 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434800
16 December 1997
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421435
11 December 1997
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 779456
3 November 1997
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460996
1 July 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394809
10 February 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1105892
6 January 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383415
22 May 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1084097
10 May 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1083155
11 March 1996
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 884569
29 December 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1367611
7 November 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1425658
15 May 1995
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1228106
1 December 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1400149
8 November 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 848741
27 September 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 844220
9 December 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1137330
25 November 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1139010
12 June 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 957635
23 April 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1269154
7 January 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1265219
13 November 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1311894
28 November 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 922115
14 November 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1232293
17 November 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 924685
10 April 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1195504
12 April 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 501924
20 November 1987
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027650
9 December 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1331627
8 November 1985
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 994196
13 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 976389
18 November 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967086
5 January 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279535
25 November 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968765
Construction/Loadline › Markings › Fresh Water Load Line
Issued 7 June 2006
Resolved
Draft Marks need to be renewed as required by 46 CFR 170.120
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 10 July 2006
Resolution: Repainted draft marks. Found to be satisfactory.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 June 2006
Resolved
Renew or repair #1 port cargo hatch cover latching mechanism/dog as required by 46 CFR 42.15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 10 July 2006
Resolution: Built up cargo hatch latching. Found to be satisfactory.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 7 June 2006
Resolved
Provide fixed containment under or around transfer connection point for lube oil tank as required by 33 CFR 153.310 (The vessel has a fixed containment container, but it isn't fixed under the connection point. Vessel representative (Alan) plans to extend the connection point of the lube oil tank to a point above the existing containment container.)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 10 July 2006
Resolution: Extended piping to fit over containment container. Found to be satisfactory.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 7 June 2006
Resolved
Provide on board notification checklist and emergency procedures as required by 33 CFR 155.1040
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 10 July 2006
Resolution: Emergency checklist was updated and found to be satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 11 April 2005
Resolved
Reattach reach rod to cargo suction valve in #2P cargo tank as per 46 CFR 32.50-15(b).
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 29 April 2005
Resolution: Reach rod reattached.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 April 2005
Resolved
Replace missing gasket for #2P cargo tank hatch cover.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 29 April 2005
Resolution: Gasket replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 11 April 2005
Resolved
Replace missing panel in protective cover over cargo pump prime mover as per 46 CFR 32.35-5.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 29 April 2005
Resolution: Cover replaced.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 22 June 2004
Resolved
The Oil Transfer Procedures (OTP) are not user friendly and in many cases omit required information. See Worklist for examples of some of the deficient areas. These items must be addressed in accordance with 33 CFR 155.750.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 21 July 2004
Resolution: Transfer Procedures have been revised to include missing information.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 22 June 2004
Resolved
The forward leg of the port running light stand and all three legs on the stbd running light stand are fractured and need to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 21 July 2004
Resolution: Running light stands have been repaired.
Stability › Watertight Integrity › General
Issued 22 June 2004
Resolved
The hatch cover dogs on the bow void need to be freed and lubricated so they can function properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 21 July 2004
Resolution: Subject hatch dogs were replaced.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 22 June 2004
Resolved
The draft marks and hailing port both need to be repainted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 21 July 2004
Resolution: Draft marks and hailing port were repainted.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 22 June 2004
Resolved
The proper capacity of the barge must be furnished. It is unknown whether the capacity given includes the independent deck tank. If the cap is over 6,290 bbls overfill devices must be added to all cargo tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 21 July 2004
Resolution: Total capacity with addition of independent tanks does not exceed 6290 bbls. Overfill protection not required.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 22 June 2004
Resolved
A guard on the clutch housing of the cargo pump needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 21 July 2004
Resolution: Guard installed on clutch housing.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 22 June 2004
Resolved
People authorized to be in Charge of transfer Operations must be designated in writing. 33 CFR 155.700.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 21 July 2004
Resolution: PIC designated by position in revised transfer procedures.
Electrical
Issued 23 March 2001
Resolved
PROVIDE DOCUMENTATION THAT ELECTRICAL BOX/SYSTEM AMIDSHIPS AT WATER TANK ISINTRINSICALLY SAFE.
Condition: Unknown
Due 23 May 2001
Resolved 21 March 2003
Construction/Loadline
Issued 23 March 2001
Resolved
REPAINT DRAFT MARKS AND NAME WITH CONTRASTING COLOR.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Engineering
Issued 17 November 1998
Resolved
RENEW LUBE OIL TANK VENT SCREEN PRIOR TO USE. ALSO RENEW FORWARD VOID VENT SCREEN AS PER 46 CFR 32.55-25(C).
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Deck/Cargo
Issued 17 November 1998
Resolved
ENSURE PRESSURE RELIEF VALVES HAVE ALL BOLTS AS PER 46 CFR 38.10-1.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Engineering
Issued 17 November 1998
Resolved
SECURE CARGO PUMP ENGINE FUEL LINES TO DECK. LINES HAVE BROKEN FREE OF HANGERS ON DECK. 46 CFR 50-75(B).
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Deck/Cargo
Issued 17 November 1998
Resolved
PIPE HANGER ON CARGO HEADER SEVERELY CORRODED. RENEW HANGER AS PER 46 CFR 38.10-1
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Engineering
Issued 17 November 1998
Resolved
INSPECTION REVEALED FUEL OIL LINES AND FITTINGS EXCESSIVELY CORRODED. RENEWOR REPAIR TO MEET 46 CFR 56.50-70(B).
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Construction/Loadline
Issued 17 November 1998
Resolved
FOUND HATCHES AND ASSOCIATED FITTINGS SEVERELY CORRODED. RENEW OR REPAIR ASNECESSARY HATCHES FOR BOTH FORWARD AND AFT VOIDS AS PER 46 CFR 31.10-17(E).
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Construction/Loadline
Issued 17 November 1998
Resolved
REMOVE PRODUCT FROM AFT VOID. TEST ENTIRE FORWARD TRANSVERSE BULKHEAD FOR LEAKS AS PER 46 CFR 31.10-17 (D).
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Deck/Cargo
Issued 17 November 1998
Resolved
REMOVE OR REPLACE ALL QUICK RELEASE CAPS ON ALL CARGO SYSTEMS WITH COAST GUARD APPROVED CAPS. CARGO HOSES NOT IN USE MUST USE QUICK DISCONNECTS WHICH MEET 33 CFR 154.500 (D)(3)
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Deck/Cargo
Issued 17 November 1998
Resolved
PROVE ANNUAL TESTING OF CARGO PIPE PRESSURE GAUGE AS PER 46 CFR 35.35- 70(C).
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Deck/Cargo
Issued 17 November 1998
Resolved
PRESSURE RELIEF VALVES ON BOARD NOT STAMPED WITH COAST GUARD APPROVAL NUMBERS. PROVE COAST GUARD APPROVAL OF VALVES OR RENEW WITH APPROVED VALVESAS PER 46 CFR 32.20-5.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Deck/Cargo
Issued 17 November 1998
Resolved
HOSES ON DECK, NOT IN USE HAD MISSING OR IMPROPER CLOSING DEVICES. INSTALL CLOSING DEVICES AS PER 33 CFR 155.805(A).
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Deck/Cargo
Issued 6 January 1997
Resolved
RENEW DETERIORATED VALVE HANDLES TO ELECTRIC LUBE OIL TRANSFER PUMP.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Construction/Loadline
Issued 29 December 1995
Resolved
CONDUCT THE REQUIRED MINIMUN SECTION MODULUS AND PLATING THICKNESS REQUIREMENTS OF 46 CFR 32.59 AND PROVIDE THE RESULTS TO THE [name withheld].
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Deck/Cargo
Issued 9 December 1992
Resolved
RENEW DRAIN VALVES ON PORT AFT CONTAINMENT.
Condition: Unknown
Due 9 December 1992
Resolved 9 December 1992
Deck/Cargo
Issued 12 June 1992
Resolved
PERMANENTLY ATTACH ALL INDEPENDENT DECK-MOUNTED LUBE OIL TANKS. OWNER MUST COMPLY WITH [name withheld] LETTER 16713 DATED 06JAN92. ITEM MUST BE COMPLETED BY COMPLIANCE DATE OR NEXT DRYDOCK.
Condition: Unknown
Due 12 June 1992
Resolved 12 June 1992
Deck/Cargo
Issued 7 January 1992
Resolved
PERMANENTLY ATTACH ALL INDEPENDENT DECK-MOUNTED LUBE OIL TANKS.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Deck/Cargo
Issued 13 November 1991
Resolved
PROPERLY SECURE 7000GAL LUBE OIL TANK TO DECK. TEMPORARY MEANS MUST BE PROVIDED PRIOR TO VESSEL DEPARTING PRESENT LOCATION AND ACCOMPLISHED WHEN VESSEL IS NEXT GAS FREE AND NOT LATER THAN 13 APR 92._x001C_
Condition: Unknown
Due 13 November 1991
Resolved 13 November 1991