MAURY USCG vessel records Sign in
← All vessels

GULF TRADER

GULF TRADER is a 1964 freight ship. The Coast Guard has recorded 47 inspections since 1983, most recently in September 1999, along with 74 deficiencies.

Records from 1983 to 1999. Most recent: inspection, 30 September 1999.

Built
1964
Last inspected
30 September 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6407884 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-44795

Inspections, by type

…with no type recorded17
Years with a record 15 calendar years (1983–1999)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8988 - Regulatory (Subpart C or D), Gross Ton
6405 - Dual (D), Gross Ton
9613 - Convention (Subpart B), Gross Ton
5442 - Regulatory (Subpart C or D), Net Ton
3467 - Dual (D), Net Ton
5499 - Convention (Subpart B), Net Ton
11368 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KRHIMMSI not assigned · expired · compulsorily equipped · granted 28 October 1991, cancelled 28 October 1996
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 47

30 September 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1351135
29 December 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808768
22 July 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129277
6 November 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1414887
1 October 1997 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1430472
29 August 1997 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1122071
5 June 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1109432
27 March 1997 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1380801
25 April 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1109504
12 January 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1417859
1 April 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1471082
12 August 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1267035
6 August 1992 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 956646
6 August 1992 Permit to Proceed
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962552
1 June 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 960850
8 May 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 441976
8 May 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 500814
31 January 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315275
27 January 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954099
27 January 1992 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 956128
27 January 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1134227
6 January 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 476188
20 December 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954077
18 November 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 933228
1 October 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 938529
23 September 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 535414
14 May 1991 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1211703
11 February 1991 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 905471
3 February 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 996652
31 January 1991 Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 930888
2 November 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 909233
17 October 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1232654
4 September 1990 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1213069
1 September 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 904124
27 September 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1216297
12 April 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1207561
6 April 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039461
6 October 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1202246
11 August 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1310162
27 August 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1323864
3 July 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333388
20 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 982552
3 December 1984 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016071
27 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283740
3 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975320
3 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284524
4 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971826

Deficiency record · 74

Unknown
Issued 1 October 1997 Resolved
COMPLETE PORT/STARBOARD BOILER REFACTORY REPAIRS IAW PROPOSAL SUBMITTED TO [name withheld], TX.
Condition: Unknown
Due 1 November 1997
Resolved 19 November 1997
Unknown
Issued 1 October 1997 Resolved
REPLACE/REPAIR GASKETS ON CARGO HATCH #3 AND #5.
Condition: Unknown
Due 1 November 1997
Resolved 19 November 1997
Unknown
Issued 1 October 1997 Resolved
PORT/STARBOARD LIFEBOAT DAVITS: CONDUCT SURVEY OF DAVITS, RENEW CORRODED BOLTS ON SHEAVES AND AND AROUND FOUNDATION AS NEEDED, AND EFFECT REPAIRS TODECK AROUND STBD DAVIT FOUNDATION.
Condition: Unknown
Due 1 November 1997
Resolved 19 November 1997
Construction/Loadline
Issued 12 January 1996 Resolved
#6 F.O. - GOOSENECK VENT-PROVIDE FLAME SCREEN.
Condition: Unknown
Due 22 January 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
STEERING GEAR ROOM VENT COVER WASTED AT EDGE- REPAIR.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#4 BALLAST, REPAIR WASTED AND HOLED AREA.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#6 F.O. DOUBLE BOTTOM, PROVIDE FLAME SCREEN AND FLOAT BALL.
Condition: Unknown
Due 22 January 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
ROPE LOCKER VENT AT FORECASTLE, REPAIR WASTED AND HOLED AREA,
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#1 F.O., GOOSENECK VENT HOLED-REPAIR.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#2 DOUBLE BOTTOM F.O. - REPAIR VENT COVER.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#1 DOUBLE BOTTOM F.O. - REPAIR VENT COVER.
Condition: Unknown
Due 22 January 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
GOOSENECK VENT, PORT SIDE, INBOARD, ADJACENT TO #1 CARGO-REPAIR WASTED AND HOLED.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
PORT SIDE GOOSENECK VENT ADJACENT TO FIRE STA. 16 - REPAIR WASTED AND HOLED.
Condition: Unknown
Due 6 May 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
PROVIDE STOPS ON ALL WING NUT HATCH CLOSURES
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
CROP AND RENEW WASTED PLATE ON ANCHOR WINDLASS ON PORTSIDE ADJACENT TO CAT HEAD.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
BOATSWAIN STORES- PORT SIDE AFT- RENEW DOOR GASKET.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
RENEW CLEVIS TO HATCH DOGS AT #3 CARGO HOLD FAN HATCH.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Deck/Cargo
Issued 12 January 1996 Resolved
PROVIDE LETTER FROM MARAD REGARDING THE FUTURE USE OF CARGO OIL TANKS.
Condition: Unknown
Due 12 February 1996
Resolved 26 December 1996
Electrical
Issued 12 January 1996 Resolved
GALLEY- PROVIDE COVER FOR ELEC. JUNCTION BOS IN OVERHEAD. DEMONSTRATE PROPER OPERATION OF DISHWASHER. DEMONSTRATE PROPER OPERATION OF EXHAUST VENTS OVER OVENS.
Condition: Unknown
Due 24 January 1996
Resolved 26 December 1996
Accommodation/Occupational Safety
Issued 12 January 1996 Resolved
PROVIDE CEILING TILES AT 01 DECK PORT SIDE.
Condition: Unknown
Due 24 April 1996
Resolved 26 December 1996
Electrical
Issued 12 January 1996 Resolved
PROVIDE COVER TO LIGHT FIXTURE AT STARBOARD SIDE ADJACENT TO [name withheld].
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Accommodation/Occupational Safety
Issued 12 January 1996 Resolved
CREW LAUNDRY- REPAIR DRYER. REPAIR LEAKING WATER VALVES. PROVIDE MISSING CEILING TILES.
Condition: Unknown
Due 22 January 1996
Resolved 26 December 1996
Documentation
Issued 12 January 1996 Resolved
REVISE FIRE PLAN TO PROPERLY ACCOUNT FOR ALARM BELLS ON EXTERIOR AT AFT OF DECK HOUSE.
Condition: Unknown
Due 24 April 1996
Resolved 26 December 1996
Lifesaving
Issued 12 January 1996 Resolved
PROVIDE REQURIED MEDICAL SUPPPLIES AND MEDICINES AS NEEDED PRIOR TO FULL ACTIVATION.
Condition: Unknown
Due 6 May 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#1 HOLD, FORECASTLE, REPAIR CLOSURE HINGES.
Condition: Unknown
Due 22 January 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#2 FUEL OIL, STARBOARD, FREE FLOAT BALL
Condition: Unknown
Due 22 January 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#6 F.O. , STARBOARD, MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
PORT SIDE VENT COVER NEAR BOATSWAIN STORES, WASTED AT EDGES-REPAIR.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#5 F.O. DT- GOOSENECK VENT WASTED AND HOLED-REPAIR.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#4 BALLAST- GOOSENECK VENT WASTED AND HOLED-REPAIR.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
GOOSENECK VENT AT PORT QUARTER MAIN DECK- MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Deck/Cargo
Issued 12 January 1996 Resolved
CROP AND RENEW STIFFENER INWAY OF VANG PAD EYE ON PORT SIDE FORWARD.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#2 HOLD- Crop and renew wasted forward deck foundation at hatch hinges.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
STARBOARD SIDE AFT AT DECK HOUSE, REPAIR WASTED AREAS AT DECK (INSULATED VENT).
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Accommodation/Occupational Safety
Issued 12 January 1996 Resolved
REPAIR GALLEY DRAIN WHERE LEAKING INWAY OF ATHWARTSHIPS PASSAGEWAY OVERHEAD.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Deck/Cargo
Issued 12 January 1996 Resolved
PROVIDE CURRENT CARGO GEAR CERTIFICATE PRIOR TO USE OF ANY CARGO GEAR.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Lifesaving
Issued 12 January 1996 Resolved
PROVIDE TWO ADDITIONAL LIFERAFTS TO SUPPLEMENT LIFEBOATS FOR CARRIAGE OF ADDITIONAL PERSONNEL DURING SCHEDULED SEA TRAILS.
Condition: Unknown
Due 12 January 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
PROVIDE THREE SUITABLE PORTABLE PUMPS WITH SUFFICIENT HOSE TO SUPPLEMENT CARGO HOLD BILGE SYSTEM DURING SEA TRIALS.
Condition: Unknown
Due 12 January 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
PROVE OPERATION OF THE FOLLOWING BILGE WELLS: 2P, 3P, 4P, 5P/S.
Condition: Unknown
Due 24 January 1996
Resolved 26 December 1996
Engineering
Issued 12 January 1996 Resolved
PROVE DC HEATER SAFETY
Condition: Unknown
Due 24 January 1996
Resolved 26 December 1996
Navigation
Issued 12 January 1996 Resolved
REPAIR FU STEERING SYSTEM IN WAY OF FLYING BRIDGE.
Condition: Unknown
Due 24 April 1996
Resolved 26 December 1996
Lifesaving
Issued 12 January 1996 Resolved
REPLACE WHEEL TO PORT LIFEBOAT.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Engineering
Issued 12 January 1996 Resolved
REPLACE O-RINGS ON EVAP. AS NEEDED.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
RENEW GASKET TO P/S SIDEPORTS.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
REPAIR STBD SIDE PORT HATCH WHERE FOLDED OVER TO ALLOW FOR FULL GASKET CONTACT.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
REPAIR/REPLACE DOGS AS NEEDED TO ENGINE ROOM W/T HATCH.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#3 DECK MACHINERY TOWER, CENTER WALK WAY, REPLACE GASKETS ON VENT. HATCHES.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#2 HOLD- Repair wasted gasket channel at man hole hatch.
Condition: Unknown
Due 14 February 1996
Resolved 23 February 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#3 HOLD- REPAIR/RENEW DRAG LINK TO CARGO HATCH.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#1 HOLD- Crop and renew wasted coaming at man hole hatch.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
VENT HATCH ADJACENT TO THE #3 AND #4 CARGO MAN HOLES, REPAIR WASTED COAMING.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
DOUBLE BOTTOM VENTS, STARBOARD, MAKE PERMANENT REPAIRS IN WAY OF TEMP. PATCH.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
R.F.W. TANK, STARBOARD SIDE, FREE FLOAT BALL.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#3 HOLD- RENEW AS ORIGINAL WASTED THRU AREAS TO HATCH COVER. REPLACE GASKETAS NEEDED AND CONDUCT A HOSE TEST.
Condition: Unknown
Due 6 May 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#2 HOLD-Repair hatch cover stops located at center both sides of hatch.
Condition: Unknown
Due 13 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
#5 HOLD- CROP AND RENEW FOUNDATION OF HATCH HINGE LOCATED AT STARBOARD SIDEAFT.
Condition: Unknown
Due 14 February 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
RENEW GASKET TO ROPE LOCKER W/T HATCH AND REPAIR HATCH KNIFE EDGE WHERE THINNED.
Condition: Unknown
Due 22 January 1996
Resolved 26 December 1996
Construction/Loadline
Issued 12 January 1996 Resolved
EXAMINE TRANSVERSE VERTICAL W/T BHD BETWEEN ROPE LOCKER AND WINDLASS ROOM STBD SIDE ABOVE FIRST HORIZONTAL SEAM WLD FOR WASTAGE.
Condition: Unknown
Due 24 April 1996
Resolved 26 December 1996
Construction/Loadline
Issued 1 April 1993 Resolved
RENEW AS NECESSARY ALL MAIN CARGO HATCH COVER AND GASKETS AND HOSE TEST TO THE SATIFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Lifesaving
Issued 1 April 1993 Resolved
MAKE REPAIRS TO PORT L/B FLEMMING GEAR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Electrical
Issued 1 April 1993 Resolved
REPAIR LOW LUBE OIL ALARMS ON BOTH MAIN A/A GENERATORS.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Electrical
Issued 1 April 1993 Resolved
TEST AND PROVE PROPER OPERATION OF THE EMERGENCY DIESEL UNDER LOAD, ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Engineering
Issued 1 April 1993 Resolved
CALIBRATE OR REPLACE WITH NEW CALIBRATED MAIN STEAM DRUM GAGE FOR STARBOARDPROPULSION BOILER.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Electrical
Issued 20 December 1991 Resolved
PROVE OVERSPEED OPERATION AT 115 PERCENT OF RATED SPEED ON BOTH SSTG'S. BOTH WERE TESTED, BUT NO TACH WAS AVAILABLE TO PROVE TRIPPING RPM.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Electrical
Issued 20 December 1991 Resolved
PROVE OPERATION OF LOSS OF LUBE OIL TRIP ON BOTH SSTG'S.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Accommodation/Occupational Safety
Issued 20 December 1991 Resolved
PROVE OPERATION OF FRESH WATER TANK, HOTWATER TANK AND SANITARY TANK RELIEFS.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Electrical
Issued 20 December 1991 Resolved
INSTALL PROPER STUFFING TUBES FOR ELECTRICAL CONNECTIONS ON NEW FIRE PUMP MOTOR,
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Accommodation/Occupational Safety
Issued 20 December 1991 Resolved
INSTALL NEW PUMP FOR CHLORINE TREATMENT SYSTEM ON MSD.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Documentation
Issued 1 October 1991 Resolved
PRIOR TO DEPARTURE OF SAN FRANCISCO BAY, CALIFORNIA COMPLETE A SATISFACTORYREINSPECTION AND CLEAR 28 ITEM WORK LIST ISSUED ON 01OCT91. THIS ITEM TO BE ACCOMPLISHED PRIOR TO DEPARTURE SAN FRANCISCO BAY, CALIFORNIA OR 01NOV91, WHICHEVER OCCURS FIRST TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Navigation
Issued 3 February 1991 Resolved
REPAIR PORT STEERING STATION IN WHEELHOUSE TO PROPER OPERATION PRIOR TO SAILING FOREIGN. VESSEL PERMITTED TO PROCEED TO WILMINGTON,NC TO EFFECT REPAIRS.
Condition: Unknown
Due 3 February 1991
Resolved 3 February 1991
Accommodation/Occupational Safety
Issued 1 September 1990 Resolved
MAKE MARINE SANITATION DEVICE OPERATIONAL IAW 33 CFR 159.7(C) OR OBTAIN NATIONAL DEFENSE WAIVER, PRIOR TO SAILING FOREIGN.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Construction/Loadline
Issued 1 September 1990 Resolved
MAKE UNDERWATER SURVEY RESULTS AVAILABLE TO [name withheld] FOREIGN.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Engineering
Issued 1 September 1990 Resolved
PRIOR TO SAILING AND IN NO CASE LATER THATN OCT90, REPAIR OFR REPLACE PORT BOILER MASTER BURNER FUEL OIL VALVE, DEEMING IT OPERATIONAL AS REQUIRED BY 46 CFR 62.35-20(I).
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Engineering
Issued 1 September 1990 Resolved
PLACE BACK IN OPERATION ON BOTH BOILERS, BURNER SAFETY TRIP CONTROL SYSTEM AS REQUIRED 46 CFR 52.01-10 & 62.35(A)(1), OR SHOW PROOF SYSTEM NOT INSTALLED AFTER 18DEC68 OR OBTAIN NAT'L DEFENSE WAIVER PRIOR TO SAILING FOREIGN.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.