Records from 1996 to 1997. Most recent: inspection, 29 August 1997.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 6 May 1997
Resolved
MULTIPLE FIRE EXTINGUISHERS WERE NOT SERVICED.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Accommodation/Occupational Safety
Issued 6 November 1996
Resolved
GALLEY REFRIGERATORS UNSANITARY. ILO 147.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Navigation
Issued 6 November 1996
Resolved
ADJUST STEERING TO ENSURE FULL-FREE MOVEMENT. SOLAS 74(AMENDED) REG V/19- 2._x001C_
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Navigation
Issued 6 November 1996
Resolved
U.S. COAST PILOT NOT CORRECTED.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Navigation
Issued 6 November 1996
Resolved
LIGHT LIST NOT CORRECTED.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 6 November 1996
Resolved
MSD LEAKING.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Construction/Loadline
Issued 6 November 1996
Resolved
HULL MARKINGS NOT LEGIBLE, INCLUDUNG DRAFT MARKS, PORT AND STARBOARD, LOAD LINES, VESSEL NAME AND HAILING PORT BOW AND STERN. ILLC 66- I/8.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Accommodation/Occupational Safety
Issued 6 November 1996
Resolved
VESSEL DOES NOT HAVE ADEQUATE POTABLE FRESH WATER, NOW USING BOTTLED WATER._x001C_ _x001C_
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Electrical
Issued 6 November 1996
Resolved
SEVERAL EXPOSED LIGHTS AND FIXTURES IN GALLEY AND CREW SPACES. SOLAS 60 II/27.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Electrical
Issued 6 November 1996
Resolved
ELECTRICAL OUTLET NEXT TO #1 CARGO HATCH HANGING LOOSE. SOLAS 60 II/27.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Accommodation/Occupational Safety
Issued 6 November 1996
Resolved
TOILET IN HOSPITAL SPACE INOPERATIVE AND UNSANITARY. ILO 147.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Engineering
Issued 6 November 1996
Resolved
MARINE SANITATION DEVICE MISSING CERTIFICATION LABEL.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Deck/Cargo
Issued 6 November 1996
Resolved
REPAIR STORM DAMAGED CARGO BOOM SECURING STANCHIONS. SOLAS REG 18.
Condition: Unknown
Due 1 January 1997
Resolved 4 December 1996
Engineering
Issued 6 November 1996
Resolved
SLUDGE/DIRTY OIL PUMP CONTROL SWITCH ON WEATHER DECK-STBD SIDE GLASS COVER BROKEN, OPEN TO WEATHER. SOLAS 60 II- 1/27.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Fire Fighting
Issued 6 November 1996
Resolved
TWO FIRESTATION BOXES HAVE BROKEN LATCHES AND MISSING SPANNER. SOLAS 60._x001C_
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Fire Fighting
Issued 6 November 1996
Resolved
INTERNATIONAL SHORE CONNECTION NOT STOWED AS SHOWN ON FIRE CONTROL PLAN. _x001C_ SOLAS 60 II/56(H)
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Deck/Cargo
Issued 6 November 1996
Resolved
FLAME SCREEN MISSING- PORT SIDE BUKER VENT AT BUNKER STATION.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Navigation
Issued 6 November 1996
Resolved
MAIN RADAR RANGE KNOB HAS EXCESSIVE PLAY.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Lifesaving
Issued 6 November 1996
Resolved
PORT AND STARBOARD LIFE BOATS HAVE NO EMERGENCY DRINKING WATER. SOLAS 74 (AMENDED) REG III/30.3.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996