MAURY USCG vessel records Sign in
← All vessels

SOUTHERN RUNNER

SOUTHERN RUNNER is a 1964 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1982, most recently in May 2000, along with 25 deficiencies.

Records from 1982 to 2000. Most recent: inspection, 26 May 2000.

Built
1964
Last inspected
26 May 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WU7952
Flag
UNITED STATES
—
Maury page id
psix-44799

Inspections, by type

…with no type recorded6
Years with a record 16 calendar years (1982–2000)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCH9836MMSI not assigned · expired · compulsorily equipped · granted 3 June 1994, cancelled 8 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

26 May 2000 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 817823
18 May 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1462662
2 May 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1407889
24 March 1997 Damage Survey · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1368112
2 August 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1090916
2 July 1996 Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1413011
4 June 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437108
8 May 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1387804
12 May 1994 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1170640
6 May 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171404
24 September 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1246119
5 March 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 479359
20 September 1990 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1244283
25 October 1989 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891782
19 September 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 889122
27 September 1988 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044710
8 September 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1040969
22 September 1987 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314892
23 September 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006522
24 September 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300613
15 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284096
8 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977239
29 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275833
23 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969593

Deficiency record · 25

Engineering
Issued 2 July 1996 Resolved
REPLACE ALL PUSH TYPE HOSES AND FITTINGS ON P/S MAIN ENGINE FUEL SYSTEM ANDHYDRAULIC SYSTEM. AND FUEL SYSTEM ON A/C GENERATOR. WITH APPROVED HOSES ANDFITTINGS ASE 1942 STANDARD. 46CFR182.20-40 (ii)
Condition: Unknown
Due 2 July 1996
Resolved 2 July 1996
Engineering
Issued 4 June 1996 Resolved
ELECTRICALLY GROUND FUEL OILS FILLS (P/S)._x001C_ SPECIFIC CITE: 46 CFR 182.445
Condition: Unknown
Due 4 July 1996
Resolved 3 July 1996
Documentation
Issued 4 June 1996 Resolved
PROVIDE VALID FCC OPERATOR'S LICENSE._x001C_ SPECIFIC CITE: 47 CFR PART 80
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Engineering
Issued 4 June 1996 Resolved
PROVE PROPER OPERATION OF ENGINE TACHOMETERS (P/S)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Lifesaving
Issued 4 June 1996 Resolved
PROVIDE ON ADDITIONAL ORANGE FLARE._x001C_ SPECIFIC CITE: 46 CFR 180.35-5(1)
Condition: Unknown
Due 4 July 1996
Resolved 3 July 1996
Electrical
Issued 4 June 1996 Resolved
INSTALL VOLTAGE AND AMPERE METERS FOR GENERATOR._x001C_ SPECIFIC CITE: 46 CFR 183.320(2)(C)
Condition: Unknown
Due 4 July 1996
Resolved 3 July 1996
Electrical
Issued 4 June 1996 Resolved
PROVE PROPER OPERATION OF FREQUENCY METER._x001C_ SPECIFIC CITE: 46 CFR 183.320(2)(C)
Condition: Unknown
Due 4 July 1996
Resolved 3 July 1996
Electrical
Issued 4 June 1996 Resolved
REMOVE/RE-CONNECT DEAD END WIRES ON GENERATOR._x001C_ SPECIFIC CITE: 46 CFR 183.200
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Documentation
Issued 4 June 1996 Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN._x001C_ SPECIFIC CITE: 33 CFR 151.57
Condition: Unknown
Due 4 July 1996
Resolved 3 July 1996
Lifesaving
Issued 4 June 1996 Resolved
REMOVE DIESEL FUEL FROM AFT BILGES.
Condition: Unknown
Due 4 July 1996
Resolved 3 July 1996
Lifesaving
Issued 4 June 1996 Resolved
REMOVE OILY WATER FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 4 July 1996
Resolved 3 July 1996
Documentation
Issued 8 May 1995 Resolved
PROVIDE ON BOARDD A COPY OF 46CFR166 TO 199.
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Lifesaving
Issued 8 May 1995 Resolved
PROVIDE WEAKLINK FOR 16 PERSON LIFEFLOAT.
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Lifesaving
Issued 8 May 1995 Resolved
PROVIDE PADDLES AND LASH TO LIFEFLOATS.
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Accommodation/Occupational Safety
Issued 8 May 1995 Resolved
CLOSE OPENING FROM HEAD AT PFD STOWAGE.
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Electrical
Issued 8 May 1995 Resolved
MARK ALL CONTROLLERS
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Lifesaving
Issued 8 May 1995 Resolved
PUT RING LIGHT ON SEPARATE LINE.
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Lifesaving
Issued 8 May 1995 Resolved
REPLACE OUTDATED AMMONIA IN 1ST AID KIT.
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Engineering
Issued 8 May 1995 Resolved
WELD EXHAUST LEAK PORT ENGINE.
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Engineering
Issued 8 May 1995 Resolved
DOUBLE CLAMP RAW WATER HOSES
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Engineering
Issued 8 May 1995 Resolved
TIGHTEN P/S PACKING FOR TAIL SHAFT.
Condition: Unknown
Due 22 May 1995
Resolved 29 June 1995
Engineering
Issued 8 September 1988 Resolved
REPLACE WORN PIPE WHICH HOUSES STARBOARD MORSE CONTROL CABLE. 46 CFR 176.25
Condition: Unknown
Due 8 September 1988
Resolved 8 September 1988
Electrical
Issued 8 September 1988 Resolved
REPLACE OR REPAIR FRONT PANEL ON SWITCHBOARD LOCATED ON BRIDGE. 46 CFR 183.05-15
Condition: Unknown
Due 8 September 1988
Resolved 8 September 1988
Unknown
Issued 8 September 1988 Resolved
REPACK REACH ROD GLANDS LOCATED ON STERN DECK. 46 CFR 56.50-1(9)(2)(IV)
Condition: Unknown
Due 8 September 1988
Resolved 8 September 1988
Electrical
Issued 8 September 1988 Resolved
PROPERLY CONNECT THE AFT FUEL TANK GROUNDING WIRE,AND REPLACE OPEN HEATER SWITCHES WITH WEATHER TIGHI SWITCH BOXES. 46 CFR 183.05-50
Condition: Unknown
Due 8 September 1988
Resolved 8 September 1988