Records from 1981 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 104
28 April 2026
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319269
1 May 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8126466
11 June 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7917340
26 July 2023
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7759072
15 May 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7689532
9 May 2023
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7684431
25 April 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7675825
4 April 2023
Deficiency Check · MTSA Verification · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7662413
21 November 2022
Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7598322
21 September 2022
MTSA Verification · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7563383
31 May 2022
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7465754
13 April 2022
Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7430761
6 October 2021
MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7328280
27 July 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7272673
20 April 2021
DAPI Audit · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7180064
19 November 2020
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7099111
19 November 2020
Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7100569
27 June 2019
Deficiency Check · Administrative Inspection · Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6728419
18 March 2019
Administrative Inspection · Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6645285
16 March 2019
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6648479
13 March 2018
MARPOL Annex VI Survey · DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6370907
16 February 2018
Administrative Inspection · In-Service Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6373110
14 November 2017
Hull Examination · Deficiency Check · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6307093
10 August 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6237244
12 July 2017
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6211617
11 January 2017
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6071718
13 July 2016
MARPOL Annex VI Survey · Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5936557
19 May 2016
Spot Check · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5962174
13 July 2015
MTSA Verification · Spot Check · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5179646
27 August 2014
MTSA Verification · Spot Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4967991
7 March 2014
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4816008
16 July 2012
DAPI Audit · Re-Inspection · Damage Survey · Examination of Repairs · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4383748
15 July 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4383645
2 May 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4304561
22 July 2011
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4087091
18 October 2010
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3884704
27 April 2009
Deficiency Check · DAPI Audit · Annual Inspection · MARPOL Annex VI Survey · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3459637
20 August 2008
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3320421
15 April 2008
DAPI Audit · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3183689
15 November 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3097576
12 June 2007
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3078561
27 March 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2896106
17 March 2006
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2604296
1 June 2005
Security Plan Amendment Review - ASP · Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2375706
7 April 2005
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2293987
28 May 2004
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2080970
22 April 2004
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2047332
2 June 2003
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1807985
12 May 2003
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1791517
10 April 2003
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739845
15 November 2002
Hull Examination · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1702675
18 April 2002
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1600102
9 August 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1070202
12 April 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1387031
18 July 2000
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 819686
17 April 2000
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1465556
15 November 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 807395
4 June 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 805137
20 April 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470978
12 August 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 795848
17 April 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1472108
16 March 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1108599
7 November 1997
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1398791
9 June 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 775471
28 May 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1108472
17 April 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1439865
16 January 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1098404
14 August 1996
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1088610
18 April 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1430176
18 April 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1336650
17 July 1994
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 169245
19 May 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 859939
3 May 1994
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1171668
14 June 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 113677
11 June 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1147999
11 May 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1138560
10 November 1992
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 830264
6 September 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1291
27 July 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 104044
24 June 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 130457
23 April 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 960100
24 April 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 924662
21 August 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1235575
25 April 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 922777
17 July 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1215319
1 June 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1195944
15 May 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 893065
26 April 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1201018
13 January 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 887211
28 April 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1042848
9 March 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1337760
7 March 1988
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1336808
24 January 1988
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1014180
2 November 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1019701
23 September 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1007834
11 September 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1316043
29 July 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1023775
6 November 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1016042
15 September 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1311654
15 September 1986
COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1323833
7 November 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 988287
26 September 1985
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 992300
12 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965453
24 July 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277773
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2024
Resolved
A vessel must be operated in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Spare portable fire extinguishers stored in engine room not secured to prevent accidental discharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 25 June 2024
Resolution: Extinguishers secured in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2024
Resolved
46 CFR 182.01-5 IAW 46 CFR 119.115 All machinery is to be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. #3 bilge piping in engine room leaked just below valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 25 June 2024
Resolution: Piping cap removed, replaced using fresh thread tape, and tightened.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 June 2024
Resolved
Cables and wires must be installed with metal supports spaced not more than 24 inches apart. Cables located in in the center of the engine room overhead were supported with plastic and not metal supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 25 June 2024
Resolution: Metal bands added to cable/wire supports in engine rooom overhead.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 11 June 2024
Resolved
46 CFR 182.15-20 IAW 46 CFR 182.20-20 IAW 46 CFR 119.115 Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. Insulating covering for port engine exhaust piping in void #7 was missing wiring to fully secure insulation to exhaust pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 25 June 2024
Resolution: Insulation resecured to exhaust piping.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2023
Resolved
Carry only 338 adult persons (passeneger and crew) until the 12 condemned and/or missing adult PFD’s are replaced. Vessel needs 350 adult PFDs as per 46CFR117.71(a).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2023
Resolved 15 May 2023
Resolution: Via e-mail and photo.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 April 2023
Resolved
Replace any expired first aid kit items. Vessel had 3 first aid kits onboard but some items were expired in every kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2023
Resolved 14 April 2023
Resolution: Received an Email picture
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2022
Resolved
Carry only 346 adult passengers until the condemned adult PFD’s are replaced. 46CFR117.71
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: Vessel recived 10 new PFD"s and they have been installed on the vessel as per owner email. Adult Pfd count is now 350 as per the COI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 April 2022
Resolved
Replace the expired distress flares. 46CFR117.68
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 19 April 2022
Resolution: E-mail Photo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2022
Resolved
Replace or shorten the life ring tag lines. Approximately 2 foot of the line which is attached to the life ring and exposed to the sun is deteriorating due to exposure. 46CFR117.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: As per owner email and order form.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Post Employee Assistance Program (EAP) phone number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 10 May 2021
Resolution: Received email evidence sufficient to clear def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Provide documentation of EAP Supervisor training. A minimum of one hour is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 10 June 2021
Resolution: Received email evidence sufficient to clear def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Provide name and contact info for Substance Abuse Professional.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 10 May 2021
Resolution: Received email evidence sufficient to clear def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2021
Resolved
Replace worn flexible non-metallic hose for Port Main Engine lube oil pressure gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 13 May 2021
Resolution: Received email evidence sufficient to clear def.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 5 May 2021
Resolved
Ensure all block and tackle fittings for gangway are properly moused.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 13 May 2021
Resolution: Received email evidence sufficient to clear def.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 May 2021
Resolved
Mark all emergency exits as detailed in stated cite. Six doors require marking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 27 May 2021
Resolution: Received photographic evidence sufficienct to clear deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2020
Resolved
Replace broken shaft with one of the same adequate size and material and conduct sea trials in the presence of Coast Guard Marine Inspectors prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2021
Resolution: Witnessed satisfactory operation of shaft while underway. All associated hardware installed properly and no vibration was evident. Only a short portion of the shaft is visible from inside the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2019
Resolved
Carry only 342 adult persons until the destroyed type I PFD’s are replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel replaced destroyed PFD's. Vessel now carries PFD in accordance with COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2019
Resolved
Replace the leaking forward hold, bilge piping system, check valve.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel intalled new check valve.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 June 2019
Resolved
Install a screen on the installed bilge system pick up in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel installed screen on bilge pickup.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 27 June 2019
Resolved
Post operating and safety instructions for the MSD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel posted operating instructions in MSD Space.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 27 June 2019
Resolved
Re-install the blower motor belt guard and ensure the motor is properly wired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel reinstalled guard and properly wired motor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2019
Resolved
Remove or properly terminate the abandoned wires (old gen wires) from the overhead of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Wires terminated into electrical boxes properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2019
Resolved
Insulate both of the exposed generators exhaust flanges.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel reinstalled insulation on exhaust flanges.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 27 June 2019
Resolved
Label the “open” direction on the generator room escape scuttle.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel placed directions near egress from engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 June 2019
Resolved
Ensure the pyro is replaced prior to the expiration dates (July and Aug, 2019)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel has new pyro on board.
Fire Fighting › Structural - Horizontal Zones › General
Issued 7 May 2018
Resolved
Replace the missing overhead insulation in the generator room. There were two very small areas that were missed, approx. 3"x 6” when the insulation was re-installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2018
Resolved
Permanently support with meatal brackets the forward generator power cable to the vessel's overhead. The cable was temporarily supported with nylon line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Electrical › Electrical Distribution System (service) › Switch
Issued 7 May 2018
Resolved
Properly cover the new 24volt battery system (generator) exposed thermals on the battery selector switch. The terminals were temporarily covered.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 7 May 2018
Resolved
Properly mount the 1st deck, forward, port side, fire extinguisher bracket (upper support bolt is loose).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Engineering › Fuel Oil Service System › Piping
Issued 7 May 2018
Resolved
Provide the new generator fuel line pipe specifications to MSD Peoria.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 7 May 2018
Resolved
In lieu of actually testing the rebuilt MDE’s safeties, provide a service report that the MDE’s safeties were tested by an approved vender (Master stated the tests were completed and he was waiting for the documentation).
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 May 2018
Resolved
Carry only 315 adult passengers until the damaged PFD’s are repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Accommodation/Occupational Safety › Ventilation › General
Issued 13 March 2018
Resolved
Provide the generator room supply fan CFM to MSD Peoria.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 14 November 2017
Resolved
As per 46CFR176.25-50 and 46CFR 176.25-10(b); prior to placing the vessel back in service in the spring of 2018, repair or replace the leaking seals/gaskets on both the MDE's and generators. The vessel is currently in winter lay-up status.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2018
Resolution: New MDE's and Gens were installed.
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2017
Resolved
Clean the excess oil residue of the generators exhaust fan housing area.
Due 12 August 2017
Resolved 30 August 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2017
Resolved
Seal the stern void high level bilge alarm wire, bulkhead, penetration stuffing tube.
Due 12 August 2017
Resolved 30 August 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 July 2017
Resolved
Paint or better indentify the location of the emergency fuel shut off valve location.
Due 12 August 2017
Resolved 30 August 2017
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2017
Resolved
Replace the worn/deteriorated retro on all the vessel life rings.
Due 12 August 2017
Resolved 30 August 2017
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 12 July 2017
Resolved
Update the Senior Deckhand Letter.
Due 12 August 2017
Resolved 30 August 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 12 July 2017
Resolved
Provide a safety inspection and service repair report from a marine repair facility for the vessel’s MDE’s and Generators.
Due 12 August 2017
Resolved 30 August 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 July 2017
Resolved
Update the expired and missing items in the vessel’s first aid kit.
Due 12 August 2017
Resolved 30 August 2017
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 July 2017
Resolved
Update the 2017 drug and alcohol testing crew list.
Due 12 August 2017
Resolved 18 September 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 July 2017
Resolved
Determine the cause and repair as necessary the bow ramp electrical motor, (motor is tripping out).
Due 24 September 2017
Resolved 30 August 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 July 2017
Resolved
Cover the MDE’s exposed exhaust flex joints.
Due 12 August 2017
Resolved 30 August 2017
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 July 2017
Resolved
Carry only 305 adult persons until the damaged PFD’s are repaired or replaced.
Due 12 August 2017
Resolved 30 August 2017
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 July 2016
Resolved
Carry only 326 adult persons until the damaged PFD’s are repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 24 August 2016
Electrical › Lighting (service) › Conductor
Issued 13 July 2016
Resolved
Permanently wire the 3rd deck rope lighting.
Condition: Placed in Improper Service
Due 13 August 2016
Resolved 24 August 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 July 2016
Resolved
Ensure the vessel has a valid COD.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 July 2016
Resolved
Replace the 1st deck, port, bow, overhead electrical box broken cover plate.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Electrical › Electrical Distribution System (emergency) › Conductor
Issued 13 July 2016
Resolved
Properly wire the 2nd deck (amidships) overhead P/A speaker.
Due 13 August 2016
Resolved 24 August 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 13 July 2016
Resolved
Clean the entire E/R, stbd side exhaust vent.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 July 2016
Resolved
Clean under the generators and the generator room deck (oil soaked rags, tape, oil reside…).
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 July 2016
Resolved
Blanket the forward generator exposed exhaust flange.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 13 July 2016
Resolved
Ensure to 2015 MIS report was submitted by the consortium or submit the vessel report online. Once submitted ensure there is a copy available to verify 25% random test rate.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 July 2016
Resolved
Provide a 2015 crew list to verify the 25% test rate.
Due 13 August 2016
Resolved 24 August 2016
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 13 July 2015
Resolved
Provide MSD Peoria with an annual engine and generator service report or test all engine safeties and over speeds in the presence of the CG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2015
Resolved 11 September 2015
Fire Fighting › Structural - Horizontal Zones › General
Issued 13 July 2015
Resolved
Properly secure the generator room overhead insulation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2015
Resolved 11 September 2015
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 July 2015
Resolved
Carry only 342 passengers and crew until the condemned PFD's are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 September 2015
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 July 2015
Resolved
Post PFD donning instruction on the third deck area. Existing instruction are weathered.
Due 1 September 2015
Resolved 11 September 2015
Stability › Severe Wind/Roll › General
Issued 13 July 2015
Resolved
Post the vessels most recent stability letter.
Action required: 705 - Other - as specified
Due 1 September 2015
Resolved 11 September 2015
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 13 July 2015
Resolved
Ensure the company has a DOT back ground check form available.
Due 13 August 2015
Resolved 14 July 2015
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 July 2015
Resolved
Provide the Drug Consortium with a current crew list.
Action required: 705 - Other - as specified
Due 1 September 2015
Resolved 11 September 2015
Construction/Loadline › Hull › Hull Plating
Issued 7 March 2014
Resolved
Bow void renew #1 keel center line frames
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 6 April 2015
Construction/Loadline › Hull › Hull Plating
Issued 7 March 2014
Resolved
Void #3 renew 5' x 6' x 1/4" sectionof port, aft outboard plate and any wasted areas of the lower bulkhead.
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 6 April 2015
Construction/Loadline › Hull › Bottom Plating
Issued 7 March 2014
Resolved
Engine Room renew outboard bottom plate and any areas of the lower aft bulkhead as necessary.
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 6 April 2015
Construction/Loadline › Hull › Bottom Plating
Issued 7 March 2014
Resolved
Void #7 remove temporary small doubler plate and replace with appropriate plate insert.
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 6 April 2015
Construction/Loadline › Hull › Bottom Plating
Issued 7 March 2014
Resolved
Make hull readily available for attending Marine Inspector to verify condition of all bottom plating.
Due 15 November 2014
Resolved 25 March 2015
Engineering › Fuel Oil Service System › Hose
Issued 16 July 2012
Resolved
Replace the forward generator fuel hose. Ensure a SAE-J-1942 and J-1475 (F) hose is used.
Due 26 August 2012
Resolved 30 August 2012
Resolution: Installed Parker Hannifin Corporation hose number 302-8, HF Type B, 1/2 inch, 4000 psi MAWP.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2012
Resolved
Properly secure to #3void overhead fathometer cables.
Due 26 August 2012
Resolved 30 August 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2012
Resolved
Properly secure the Stbd MDE starter wire.
Due 26 August 2012
Resolved 30 August 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2012
Resolved
Secure the port side overhead wires in the #7 void.
Due 26 August 2012
Resolved 30 August 2012
Construction/Loadline › Hull › Bracket
Issued 16 July 2012
Resolved
Reweld the port side, overhead gussets and fractured deck plate in the #7 void.
Condition: Improper Installation
Due 30 September 2012
Resolved 16 July 2012
Stability › Watertight Integrity › Weathertight Enclosure
Issued 16 July 2012
Resolved
Install metal shut-off valves on all PVC through hull fittings.
Due 26 August 2012
Resolved 30 August 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 16 July 2012
Resolved
Repair the #8 void P/S exhaust pipe leaks.
Due 30 September 2012
Resolved 16 April 2013
Fire Fighting › Structural - Horizontal Zones › General
Issued 16 July 2012
Resolved
Reattached the engineroom, port side, overhead insulation by the entrance ladder.
Due 26 August 2012
Resolved 30 August 2012
Stability › Watertight Integrity › General
Issued 22 July 2011
Resolved
Chalk test the engineroom/generator room W/T door and replace the gasket if necessary.
Due 22 August 2011
Resolved 18 August 2011
Electrical › Electric Generation Source (service) › Generator
Issued 22 July 2011
Resolved
Properly clean the generator housing area of old oil accumulation.
Due 22 August 2011
Resolved 18 August 2011
Engineering › Compressed Air System (control) › Piping
Issued 22 July 2011
Resolved
Remove the old abandoned generator and engineroom overhead airline.
Due 22 August 2011
Resolved 18 August 2011
Engineering › Bilge Water Management System › Not Operational
Issued 22 July 2011
Resolved
Prove proper operation of the engineroom high level alarm panel indicator lights, located at the engineroom entrance.
Due 22 August 2011
Resolved 18 August 2011
Stability › Unintentional Flooding › General
Issued 22 July 2011
Resolved
Install a strong back for the men's head deck scuttle so it can be properly secured.
Due 22 August 2011
Resolved 18 August 2011
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 July 2011
Resolved
Secure the loose carpet by the #3 void main deck scuttle.
Due 22 August 2011
Resolved 18 August 2011
Construction/Loadline › Hull › Hull Plating
Issued 22 July 2011
Resolved
Prior to operating the vessel in 2012, repair the port side, #3 void, set-in damage IWO the bilge knuckle to the satisfaction of the attending marine inspector. .
Due 1 January 2012
Resolved 30 April 2012
Construction/Loadline › Hull › Hull Plating
Issued 4 November 2010
Resolved
Prior to operating the vessel with passengers after November 01, 2011, make the necessary vessel hull extension modifications as per MSC approved plans to increase the vessel's stern freeboard. All modifications must be completed to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 1 January 2012
Resolved 30 April 2012
Stability › Unintentional Flooding › General
Issued 4 November 2010
Resolved
Once vessel's hull modifications are complete, conduct a new stability test and submit the results to MSC for approval and issuance of a new stability letter. The new stability letter's maximum stern draft reading must equate to the vessel's current draft mark locations. All modifications must be completed to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 1 January 2012
Resolved 30 April 2012
Stability › Unintentional Flooding › General
Issued 4 November 2010
Resolved
Vessel may only operate with 200 passengers onboard and must comply with all of the Naval Architects recommendations as per your letter dated 31OCT2010, until the above items have been completed and verified by a Marine Inspector.
Due 1 March 2011
Resolved 2 March 2011
Resolution: Modified with new requirement.
Stability › Unintentional Flooding › General
Issued 18 October 2010
Resolved
As per Naval Architects DeJong & Lebet, Inc., recommendations dated 31OCT2010, the following operating restrictions will be strictly adhered to until the hull extension modification is completed: Vessel may only operate with 200 passengers onboard. Prior to departing the dock, the vessel's fuel tank level capacity must be equal to or exceed 50 % and the potable water tank shall be full.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 January 2012
Resolved 30 April 2012
Engineering › Compressed Air System (control) › Piping
Issued 27 April 2009
Resolved
Properly support the #7 void centerline, overhead air line.
Condition: Unknown
Due 15 August 2009
Resolved 26 August 2009
Engineering › Bilge Water Management System › Not Operational
Issued 27 April 2009
Resolved
Ensure the #1 and #2 high level bilge alarm panel lights (by the engineroom entrance) operate properly.
Condition: Unknown
Due 7 September 2009
Resolved 26 August 2009
Engineering › Feedwater/Condensate Water System › Piping
Issued 27 April 2009
Resolved
Double hose clamp all heat pumps flex hosing.
Condition: Unknown
Due 15 August 2009
Resolved 26 August 2009
Engineering › Fuel Oil Service System › Piping
Issued 27 April 2009
Resolved
Properly secure the stbd side MDE fuel line.
Condition: Unknown
Due 15 August 2009
Resolved 26 August 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 April 2009
Resolved
Ensure the 2nd deck; forward life jacket locker latch operates freely.
Condition: Unknown
Due 7 September 2009
Resolved 26 August 2009
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 27 April 2009
Resolved
Post lifejacket donning instructions 1st deck forward and 2nd deck aft.
Condition: Improper/Lack of Maintenance
Due 15 August 2009
Resolved 26 August 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 April 2009
Resolved
Re-stencil the bridge ring life rings with the vessels name.
Condition: Improper/Lack of Maintenance
Due 15 August 2009
Resolved 26 August 2009
Electrical › Electric Generation Source (service) › Panelboard
Issued 27 April 2009
Resolved
Repair or remove the forward generator d/c voltage meter.
Condition: Unknown
Due 15 August 2009
Resolved 26 August 2009
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 27 April 2009
Resolved
Provide engine service report.
Condition: Unknown
Due 15 July 2009
Resolved 15 July 2009
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 27 April 2009
Resolved
Ensure the supervisors have received and documented the one hour EAP training.
Condition: Unknown
Due 7 September 2009
Resolved 19 November 2009
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 27 April 2009
Resolved
Post EAP local hotline number and policy statement.
Condition: Unknown
Due 15 August 2009
Resolved 26 August 2009
Engineering › Bilge Water Management System › Pump
Issued 15 April 2008
Resolved
Prove proper operation of the #2 void, stbd side, high level bilge alarm.
Condition: Unknown
Due 15 May 2008
Resolved 20 August 2008
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 15 April 2008
Resolved
(DAPI) Provide proof the 2008 MIS form was submitted.
Condition: Unknown
Due 15 May 2008
Resolved 20 October 2008
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 15 April 2008
Resolved
(DAPI) Post EAP local hotline number.
Condition: Unknown
Due 15 May 2008
Resolved 20 August 2008
Stability › Watertight Integrity › General
Issued 15 April 2008
Resolved
Clean and lubricate all three forward deck scuttles gaskets and sealing surfaces.
Condition: Unknown
Due 15 May 2008
Resolved 20 August 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 April 2008
Resolved
Cover exposed electrical outlet in the men's head and properly mount.
Condition: Improper Installation
Due 15 May 2008
Resolved 20 August 2008
Stability › Watertight Integrity › General
Issued 15 April 2008
Resolved
Make the aft engineroom bulkhead watertight. (2 open screw holes).
Condition: Improper/Lack of Maintenance
Due 15 May 2008
Resolved 20 August 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 April 2008
Resolved
Carry only 355 adult passengers and crew until the PFD’s are repaired or replaced.
Condition: Improper/Lack of Maintenance
Due 15 May 2008
Resolved 20 October 2008
Stability › Watertight Integrity › General
Issued 15 April 2008
Resolved
Weld the inside of the stern keg cooler fitting were it penetrates the hull. Currently only welded on the exterior.
Condition: Placed in Improper Service
Due 15 May 2008
Resolved 20 August 2008
Construction/Loadline › Structures › Deck Plating
Issued 15 November 2007
Resolved
Properly repair deck in female and male heads.
Due 15 December 2007
Resolved 15 April 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 November 2007
Resolved
Properly repair hole in aft engineroom compartment bulkhead in vicinity of stbd shaft pump.
Due 15 December 2007
Resolved 15 April 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 November 2007
Resolved
Properly repair vertical members on fwd steering compartment bulkhead.
Due 15 December 2007
Resolved 15 April 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 November 2007
Resolved
Properly gouge and reweld one pickup stbd side fwd bulkhead in the steering compartment.
Due 15 December 2007
Resolved 15 April 2008
Construction/Loadline › Structures › Deck Plating
Issued 15 November 2007
Resolved
Properly crop and renew three holes in overhead (two on stbd side) (one on port side).
Due 15 December 2007
Resolved 15 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 15 November 2007
Resolved
Properly crop and renew hole in steering compartment in way of port side rudder post (behind port exterior channel bracket).
Due 15 December 2007
Resolved 15 April 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 November 2007
Resolved
Properly crop and renew stbd side deck frame and vertical side frames to good metal in the number two void space.
Due 15 December 2007
Resolved 15 April 2008
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 November 2007
Resolved
Properly replace or repair through hull gate valves (port and stbd valves)
Due 15 December 2007
Resolved 15 April 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 November 2007
Resolved
Properly crop and renew keg cooler through hull drain line in athe steering compartment.
Due 15 May 2008
Resolved 15 April 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 27 March 2007
Resolved
Post instructions for securing the manual vents when activating the installed CO2 suppression system.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 12 June 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 27 March 2007
Resolved
Replace torn fuel tank, explosive proof, vent screen.
Condition: Unknown
Due 17 May 2007
Resolved 12 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2007
Resolved
Secure all high level, bilge alarms wires with metal supports.
Condition: Unknown
Due 17 May 2007
Resolved 12 June 2007
Construction/Loadline › Structures › Scuttle
Issued 27 March 2007
Resolved
Replace the damaged #1, stbd void, W/T scuttle gasket.
Condition: Unknown
Due 17 May 2007
Resolved 12 June 2007
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 27 March 2007
Resolved
Clean the oil and grease residue from under the generators and MDE's.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 12 June 2007
Engineering › Fuel Oil Service System › Piping
Issued 27 March 2007
Resolved
Repair the fuel oil piping leaks on the forward generator.
Condition: Unknown
Due 17 May 2007
Resolved 12 June 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 27 March 2007
Resolved
Blanket or insulate the generator dry exhaust piping and exposed turbo charger.
Condition: Placed in Improper Service
Due 17 May 2007
Resolved 12 June 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 March 2007
Resolved
Properly install (mount) the fresh water pumps, currently they are C-clamped in place.
Condition: Placed in Improper Service
Due 17 May 2007
Resolved 12 June 2007
Engineering › Freshwater System (air cooling) › Pump
Issued 27 March 2007
Resolved
Properly install (mount) the A/C water pumps, currently they are C-clamped in place.
Condition: Improper Installation
Due 17 May 2007
Resolved 12 June 2007
Fire Fighting › Fire Main › Condition
Issued 27 March 2007
Resolved
Properly repair the fireman system, replace all the temporary, dresser coupling with standard metal piping.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 12 June 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 March 2007
Resolved
Properly mount the fresh water pre-charger tank.
Condition: Improper Installation
Due 17 May 2007
Resolved 12 June 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 27 March 2007
Resolved
Clean the engineroom exhaust vents.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 12 June 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 27 March 2007
Resolved
Properly repair the generator room, port side, exhaust fan and housing.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 12 June 2007
Accommodation/Occupational Safety › Messroom › Location
Issued 27 March 2007
Resolved
Clean and sanitize the main deck bar.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 12 June 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 March 2007
Resolved
Clean all second deck, stbd side, PFD's.
Condition: Unknown
Due 17 May 2007
Resolved 12 June 2007
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 27 March 2007
Resolved
Repair the port, MDE, water temperature gauge at the entrance to the engineroom.
Condition: Unknown
Due 17 May 2007
Resolved 12 June 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 March 2007
Resolved
Update the expired items in the vessel's first aid kit.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 12 June 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 27 March 2007
Resolved
Post radio operating procedures.
Condition: Placed in Improper Service
Due 17 May 2007
Resolved 12 June 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 March 2007
Resolved
Carry only 362 adult passengers and crew until the PFD's are replaced.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 12 June 2007
Stability › Watertight Integrity › General
Issued 17 March 2006
Resolved
Install backing plates on all scuttles.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 April 2006
Resolution: Resolved
Electrical › Electric Generation Source (service) › Generator
Issued 17 March 2006
Resolved
Install lagging or deflector on generator exhaust.
Due 17 May 2007
Resolved 23 April 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 March 2006
Resolved
Repair or replace life buoy light prior to night ops.
Due 1 May 2006
Resolved 18 April 2006
Resolution: Resolved
Fire Fighting › Fire Hoses › Condition
Issued 7 April 2005
Resolved
Prove proper operation of all fire hoses on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2005
Resolution: Replaced damaged hose. Provided reciept and pictures to marine inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 7 April 2005
Resolved
Provide proper warning placard for typhoon alarm in engine room.
Due 7 May 2005
Resolved 8 April 2005
Resolution: Provided picture of posted warning placard to the marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 7 April 2005
Resolved
Properly stencil all life jackets with vessels name.
Due 7 May 2005
Resolved 29 April 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 April 2005
Resolved
Replace short lanyard on floating water light with one at least 3' and not more than 6'.
Due 7 May 2005
Resolved 29 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 April 2005
Resolved
Properly test 60 adult life jackets with 106 CG approval numbers to ensure capability of floating with 20 lbs weight. Vessel is limited to carrying 347 passengers until 60 adult life jackets are tested satisfactory or replaced.
Due 7 May 2005
Resolved 8 April 2005
Resolution: Provided pictures of float test. All life jackets passed weight test. Pictures scanned into activity.
Engineering › Bilge Water Management System
Issued 22 April 2004
Resolved
Prove proper operation of peak tank reach rod. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 7 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 April 2004
Resolved
Provide cover for port engine control electrical box. LEGACY COMPONENT DESC: Electrical control panel
Condition: Placed in Improper Service
Due 22 May 2004
Resolved 7 May 2004
Navigation › Collision/Grounding Avoidance
Issued 22 April 2004
Resolved
Properly repair windshield wiper motor. LEGACY COMPONENT DESC: Navigation Bridge Visibility
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 7 May 2004
Fire Fighting › Fixed Fire Detection System
Issued 22 April 2004
Resolved
Properly repair audible alarm for pilot house fire detection panel. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 7 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 22 April 2004
Resolved
Properly safety wire all shackles. LEGACY COMPONENT DESC: Lifeline
Condition: Placed in Improper Service
Due 22 May 2004
Resolved 7 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 April 2004
Resolved
Provide documentation on all engine safeties. LEGACY COMPONENT DESC: Shut down alarms
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 7 May 2004
Engineering › Bilge Water Management System
Issued 10 April 2003
Resolved
Properly repair leaking bilge system discharge piping. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 10 June 2003
Resolved 27 May 2003
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 10 April 2003
Resolved
Show proper operation of all engine and generator alarms and shutdowns. LEGACY COMPONENT DESC: Alarms and Safeties
Condition: Improper/Lack of Maintenance
Due 10 June 2003
Resolved 14 May 2003
Operations/Management › Drug and Alcohol Testing
Issued 10 April 2003
Resolved
Show enrollment in drug program and EAP training. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Placed in Improper Service
Due 10 June 2003
Resolved 27 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 10 April 2003
Resolved
Properly label alarm panel for bilge alarms in pilot house. LEGACY COMPONENT DESC: Bilge Monitor
Condition: Improper/Lack of Maintenance
Due 10 June 2003
Resolved 27 May 2003
Construction/Loadline › Markings
Issued 10 April 2003
Resolved
Properly mark aft draft marks in accordance with stability letter. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Placed in Improper Service
Due 10 June 2003
Resolved 4 June 2003
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 15 November 2002
Resolved
Repair or replace port propeller due to fluke being bent.
Condition: Damaged By Earlier Event
Due 15 December 2002
Resolved 25 November 2002
Construction/Loadline › Hull
Issued 15 November 2002
Resolved
Gauge behind all keel coolers and submitt results to local [name withheld] and renew wasted areas to original scantling. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2002
Resolved 9 December 2002
Resolution: Completed satisfactory repairs to side shell. Witnessed water test and no leaks were present.
Construction/Loadline › Structures › Deck Plating
Issued 15 November 2002
Resolved
Repair starboard aft deck gusset.
Condition: Unknown
Due 25 December 2002
Resolved 25 November 2002
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 April 2002
Resolved
Battery needs replacement for engineroom E-lights.
Condition: Improper/Lack of Maintenance
Due 30 April 2002
Resolved 24 April 2002
Resolution: Battery replaced.
Electrical › Electric Supply System (service) › Cable
Issued 18 April 2002
Resolved
Secure or remove dead end electrical wires on aft bulkhead of E/R.
Condition: Improper/Lack of Maintenance
Due 30 April 2002
Resolved 24 April 2002
Resolution: Wires have been removed.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 18 April 2002
Resolved
Ensure emergency lighting activates automatically.
Condition: Improper Installation
Due 30 April 2002
Resolved 24 April 2002
Resolution: Emergency lighting now activates automatically.
Lifesaving › Hand Flares
Issued 18 April 2002
Resolved
Renew day/night flares. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 31 May 2002
Resolved 1 May 2002
Resolution: Hand Flares updated
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 April 2002
Resolved
Reduce passenger count to 391 adult passengers until 9 life jackets are renewed. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 20 May 2002
Resolved 1 May 2002
Resolution: All life jackets replaced.
Electrical
Issued 12 April 2001
Resolved
Prove proper operation of aft generator frequency meter.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Electrical
Issued 12 April 2001
Resolved
Make proper repairs to all fuel leaks on aft generator. Until repairs are made a minimum of 15 minute rounds shall be made. If conditions worsens notify [name withheld] aft generator in an emergency only.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Navigation
Issued 12 April 2001
Resolved
UPDATE ALL NAVIGATIONAL PUBLICATIONS
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Engineering
Issued 12 April 2001
Resolved
Install missing exhaust lagging on port main engine.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 12 April 2001
Resolved
CARRY ONLY 396 PERSONS UNTIL 4 ADULT LIFE JACKETS ARE PROVIDED
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Construction/Loadline
Issued 17 April 2000
Resolved
ENSURE #1 AND #2 VOID SCUTTLES ARE WATERTIGHT.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Construction/Loadline
Issued 17 April 2000
Resolved
ENSURE ALL BILGE ALARMS HAVE AUDIBLE ALARMS AT OPERATING STATION.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Construction/Loadline
Issued 17 April 2000
Resolved
PRIOR TO CARRYING PASSENGERS ENSURE FWD BILGE VALVE OPERATES.
Condition: Unknown
Due 3 May 2000
Resolved 26 April 2000
Fire Fighting
Issued 17 April 2000
Resolved
ENSURE FIRE PUMP PRODUCES 60 PSI.
Condition: Unknown
Due 3 May 2000
Resolved 26 April 2000
Construction/Loadline
Issued 17 April 2000
Resolved
PROVE HIGH BILGE ALARM WIRE MEETS CFR OR NEC CODE FOR WET & DAMP LOCATION.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Lifesaving
Issued 17 April 2000
Resolved
ENSURE FIRST AID KIT MEETS REQUIREMENT OF 46 CFR 160.041
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Lifesaving
Issued 17 April 2000
Resolved
REPLACE OR PROPERLY REPAIR SECOND DECK LIFERINGS.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Engineering
Issued 17 April 2000
Resolved
PROVIDE COVERS FOR ENGINE ROOM SUPPLY AND EXHAUST VENTS.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Construction/Loadline
Issued 20 April 1999
Resolved
REPAIR BILGE ALARM PANEL AT THE TOP OF ENGINEROOM LADDER, MISSING LIGHT.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Electrical
Issued 20 April 1999
Resolved
REPAIR "E" LIGHT IN GEN ROOM.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Fire Fighting
Issued 20 April 1999
Resolved
REPLACE FIRE NOZZLES ON BOTH FIRE STATIONS WITH PROPER NOZZLES AS PER 46 CFR 118.320(c)
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999
Electrical
Issued 17 April 1998
Resolved
REPLACE (2) TWO E-LIGHTS ON 2ND DECK, ONE STBD, ONE BOW.
Condition: Unknown
Due 17 April 1998
Resolved 17 April 1998
Lifesaving
Issued 17 April 1998
Resolved
REPLACE GRAB LINE ON LIFE BUOY RING, 2ND DECK
Condition: Unknown
Due 17 April 1998
Resolved 17 April 1998
Navigation
Issued 17 April 1998
Resolved
ACQUIRE NEW EDITION OF LIGHT LIST (98 VERSION).
Condition: Unknown
Due 17 April 1998
Resolved 17 April 1998
Lifesaving
Issued 17 April 1998
Resolved
REMOVE PLASTIC TRASH CAN, MAIN DECK SNACK BAR.
Condition: Unknown
Due 17 April 1998
Resolved 17 April 1998
Engineering
Issued 16 March 1998
Resolved
SHORTEN FLEXIBLE FUEL HOSE TO MDE TO LESS THAN 36 INCHES.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Construction/Loadline
Issued 16 March 1998
Resolved
REPAIR/REPLACE SLUICE VALVE IN FORWARD BILGE COMPARTMENT.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Engineering
Issued 7 November 1997
Resolved
PRIOR TO GETTING UNDERWAY WITH PASSENGERS, PROVIDE INSPECTION FOR COAST GUARD MARINE INSPECTORS FOR INSPECTION OF PROPELLORS, SHAFTS, STRUT AND STERN TUBE BEARINGS.
Condition: Unknown
Due 7 November 1997
Resolved 7 November 1997
Lifesaving
Issued 17 April 1997
Resolved
REPLACE VISUAL DISTRESS SIGNALS PRIOR TO GETTING UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Engineering
Issued 17 April 1997
Resolved
PROVIDE FLAME SCREEN TO FUEL TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Engineering
Issued 17 April 1997
Resolved
PROVIDE MACHINERY GUARD TO BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
REPAIR EMERGENCY LIGHT IN ENGINE ROOM.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 18 April 1996
Resolved
REDUCE TOTAL PERSONS ALLOWED FROM 400 PERSONS TO 396, UNTIL (FOUR) 4 MORE APPROVED PFD'S ARE PROVIDED ON BOARD THE VESSEL.
Condition: Unknown
Due 18 May 1996
Resolved 23 April 1996
Lifesaving
Issued 3 May 1994
Resolved
LABEL PFD'S WITH VESSEL NAME
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 3 May 1994
Resolved
PROVIDE 2 ADULT PFD'S TO VESSEL
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 11 May 1993
Resolved
MARK OUTSIDE OF ENGINE ROOM ESCAPE HATCH "EMERGENCY EXIT, DO NOT BLOCK" IN LETTERS AT LEAST 1" IN HEIGHT.
Condition: Unknown
Due 11 June 1993
Resolved 28 May 1993
Lifesaving
Issued 11 May 1993
Resolved
PROVIDE TOTAL OF 400 ADULT PFDS ON BOARD.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Navigation
Issued 11 May 1993
Resolved
PROVIDE PROPER, OPERATIONAL ANCHOR LIGHT ON BOARD.
Condition: Unknown
Due 11 June 1993
Resolved 28 May 1993
Construction/Loadline
Issued 10 November 1992
Resolved
CONDUCT PERMENANT REPAIRS TO THE BULKHEADS BETWEEN SPACES 3&4 AND 4&5. WELDS NEED TO BE ON BOTH SIDES OF THE BULKHEAD AND AT LEAST 18 INCHES IN LENGTH._x001C_ _x001C_
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992
Electrical
Issued 25 April 1990
Resolved
PROVIDE RUBBER MAT IN FRONT OF MAIN PANEL IN GENERATOR ROOM.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Electrical
Issued 25 April 1990
Resolved
PLUG OPENINGS IN 12 VOLT BOXES IN E.R.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Engineering
Issued 25 April 1990
Resolved
REPAIR LEAK IN PORT MAIN ENGINE SUPPLY FUEL HOSE.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Navigation
Issued 25 April 1990
Resolved
PROVIDE EVIDENCE OF PERKO ACCEPTABILITY OF 50 WATT ROUGH SERVICE BULBS, OR INSTALL PROPER BULBS IN ALL NAVIGATION LIGHTS.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Fire Fighting
Issued 25 April 1990
Resolved
HYDRO TEST B-II CO2 PORTABLE EXTINGUISHER AT ENGINE ROOM LADDER.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Deck/Cargo
Issued 25 April 1990
Resolved
PROPERLY POSITION SUCTION HEAD IN #7 VOID.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Construction/Loadline
Issued 25 April 1990
Resolved
PLUG THRU BULKHEAD FITTING IN #7 VOID.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990
Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION STICKER AND PLACE ON DOCUMENT.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Lifesaving
Issued 25 April 1990
Resolved
PROVIDE 03 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Lifesaving
Issued 1 June 1989
Resolved
PROVIDE 53 USCG ADULT APPROVED, TYPE I, LIFE PRESERVERS NUMBER OF PERSONS ALLOWED IS RESTRICTED TO 347 UNTIL CORRECTED.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Navigation
Issued 26 April 1989
Resolved
INSTALL PROPER MFG REQUIRED LAMPS FOR EACH NAVIGATION LIGHT.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Fire Fighting
Issued 26 April 1989
Resolved
TEST FIXED CO2 SYSTEM TIME DELAY IN THE PRESENCE OF A CG MARINE INSPECTOR OR PROVIDE SERVICE REPORT VERIFYING TIME DELAY OPERATION AND LENGTH OF TIME.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Lifesaving
Issued 26 April 1989
Resolved
PROVIDE 148 USCG ADULT APPROVED, TYPE I, LIFE PRESERVERS NUMBER OF TOTAL PERSONS ALLOWED RESTRICTED TO 252 UNTIL CORRECTED. CHILD TYPE I REQUIRED 12, CHILDREN RESTRICTED TO 28 TOTAL CHILDREN.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Documentation
Issued 24 January 1988
Resolved
CONTACT [name withheld], PRIOR TO REFURBISHING VESSEL.
Condition: Unknown
Due 24 January 1988
Resolved 24 January 1988
Construction/Loadline
Issued 24 January 1988
Resolved
PLACE VESSEL ON NEAREST DRYDOCK FOR HULL EXAMINATION AS SOON AS PRACTICAL.
Condition: Unknown
Due 24 January 1988
Resolved 24 January 1988
Engineering
Issued 11 September 1987
Resolved
RAISE BILGE STRAINER IN #2 HOLD TO APPROXIMATELY 3" ABOVE DECK.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Electrical
Issued 11 September 1987
Resolved
REMOVE DEAD END CABLES AND NON FUNCTIONAL PLASTIC PIPE THROUGHOUT THE VESSEL.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Engineering
Issued 11 September 1987
Resolved
REPLACE SCREEN TO BILGE STRAINER LOCATED IN #7 HOLD.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Electrical
Issued 11 September 1987
Resolved
REPLACE PLASTIC CABLE CLAMPS SECURING ELECTRICAL WIRING WITH METAL CLAMPS THROUGHOUT VESSEL BY NEXT DRYDOCK.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Electrical
Issued 11 September 1987
Resolved
SECURE HOT WATER HEATER ELECTRICAL CABLE TO OVERHEAD WIHT METAL CLAMP(S) IN #7 HOLD.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Electrical
Issued 11 September 1987
Resolved
REMOVE OR PLACE COVER ON ELECTRICAL CABLE LOCATED IN ENGINE ROOM PORT SIDE.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Engineering
Issued 11 September 1987
Resolved
LABEL AND MOVE "T" HANDLE TO FUEL SHUTOFF VALVE LOCATED ON NEAR FORWARD BULKHEAD OF MAIN DECK SALON.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Fire Fighting
Issued 11 September 1987
Resolved
REPLACE CURRENT FIRE HOSES WITH UL APPROVED HOSES OR PROVIDE DOCUMENTATION THAT CURRENT HOSES ARE UL APPROVED.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Fire Fighting
Issued 11 September 1987
Resolved
PRESS UP FIRE HOSES AND LABEL WITH PSI AND TEST DATE.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Fire Fighting
Issued 11 September 1987
Resolved
LABEL FIRE AXE IN WHEELHOUSE WITH VESSEL NAME.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Accommodation/Occupational Safety
Issued 11 September 1987
Resolved
SECURE SODA FOUNTAIN CO2 BOTTLE IN GALLEY FROM BECOMING POSSIBLE MISSLE HAZARD.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Engineering
Issued 11 September 1987
Resolved
PROVIDE "T" HANDLE TO BILGE SUCTION VALVE AND CLEAR OUT THE MATERIAL IN THEACCESS TO THE REACH ROD FITTING LOCATED IN THE FORWARD MAIN DECK.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Fire Fighting
Issued 11 September 1987
Resolved
POST OPERATING INSTRUCTION TO THE FIXED CO2 SYSTEM AS STATED IN 46 CFR 181.20-15(D).
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Construction/Loadline
Issued 11 September 1987
Resolved
REPAIR OR REPLACE LOWER RIGHT DOG FITTING TO WATER TIGHT DOOR LOCATED IN ENGINE ROOM SO IT WILL CLOSE COMPLETELY.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Engineering
Issued 11 September 1987
Resolved
LABEL BILGE MANIFOLD LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Documentation
Issued 11 September 1987
Resolved
PROVIDE AND POST VESSEL'S STABILITY LETTER IN PASSENGER AREA.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Lifesaving
Issued 11 September 1987
Resolved
PROVIDE 16 APPROVED ADULT PFD'S EQUIPPED WITH REFLECTIVE TAPE AND VESSEL'S NAME STENCILED ON PFD.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Engineering
Issued 11 September 1987
Resolved
PROVIDE HAND BILGE PUMP CAPABLE OF 5 GPM IN ACCORDANCE WITH 46 CFR 181.10-5
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Construction/Loadline
Issued 15 September 1986
Resolved
REPLACE GASKETS TO HATCH COVERS TO #2 AND #3 HOLDS.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Lifesaving
Issued 15 September 1986
Resolved
REPLACE PADDLES TO RESCUE BOAT.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Unknown
Issued 15 September 1986
Resolved
PREPARE PRESSURE VESSELS UNDER WHEELHOUSE, IN LADY'S RESTROOM, AND UNDER MEN'S RESTROOM FOR INTERNAL EXAMINATION OR HYDRO TEST.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Construction/Loadline
Issued 15 September 1986
Resolved
REPLACE GASKETS ON HATCH COVERS TO #2 AND #3 HOLDS.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Lifesaving
Issued 15 September 1986
Resolved
REPLACE PADDLES FOR RESCUE/WORK BOAT.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Accommodation/Occupational Safety
Issued 15 September 1986
Resolved
HYDRO THE HEATING BOILER LOCATED IN THE LADIES RESTROOM AND TEST THERMOSTATCONTROLS.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986