Records from 2010 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 28
28 April 2026
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319269
1 May 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8126466
11 June 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7917340
26 July 2023
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7759072
15 May 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7689532
9 May 2023
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7684431
25 April 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7675825
4 April 2023
Deficiency Check · MTSA Verification · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7662413
21 November 2022
Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7598322
21 September 2022
MTSA Verification · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7563383
31 May 2022
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7465754
13 April 2022
Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7430761
6 October 2021
MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7328280
27 July 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7272673
20 April 2021
DAPI Audit · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7180064
19 November 2020
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7099111
19 November 2020
Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7100569
27 June 2019
Deficiency Check · Administrative Inspection · Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6728419
18 March 2019
Administrative Inspection · Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6645285
16 March 2019
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6648479
13 March 2018
MARPOL Annex VI Survey · DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6370907
16 February 2018
Administrative Inspection · In-Service Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6373110
14 November 2017
Hull Examination · Deficiency Check · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6307093
10 August 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6237244
12 July 2017
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6211617
11 January 2017
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6071718
13 July 2016
MARPOL Annex VI Survey · Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5936557
19 May 2016
Spot Check · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5962174
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2024
Resolved
A vessel must be operated in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Spare portable fire extinguishers stored in engine room not secured to prevent accidental discharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 25 June 2024
Resolution: Extinguishers secured in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2024
Resolved
46 CFR 182.01-5 IAW 46 CFR 119.115 All machinery is to be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. #3 bilge piping in engine room leaked just below valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 25 June 2024
Resolution: Piping cap removed, replaced using fresh thread tape, and tightened.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 June 2024
Resolved
Cables and wires must be installed with metal supports spaced not more than 24 inches apart. Cables located in in the center of the engine room overhead were supported with plastic and not metal supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 25 June 2024
Resolution: Metal bands added to cable/wire supports in engine rooom overhead.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 11 June 2024
Resolved
46 CFR 182.15-20 IAW 46 CFR 182.20-20 IAW 46 CFR 119.115 Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. Insulating covering for port engine exhaust piping in void #7 was missing wiring to fully secure insulation to exhaust pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 25 June 2024
Resolution: Insulation resecured to exhaust piping.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2023
Resolved
Carry only 338 adult persons (passeneger and crew) until the 12 condemned and/or missing adult PFD’s are replaced. Vessel needs 350 adult PFDs as per 46CFR117.71(a).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2023
Resolved 15 May 2023
Resolution: Via e-mail and photo.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 April 2023
Resolved
Replace any expired first aid kit items. Vessel had 3 first aid kits onboard but some items were expired in every kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2023
Resolved 14 April 2023
Resolution: Received an Email picture
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2022
Resolved
Carry only 346 adult passengers until the condemned adult PFD’s are replaced. 46CFR117.71
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: Vessel recived 10 new PFD"s and they have been installed on the vessel as per owner email. Adult Pfd count is now 350 as per the COI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 April 2022
Resolved
Replace the expired distress flares. 46CFR117.68
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 19 April 2022
Resolution: E-mail Photo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2022
Resolved
Replace or shorten the life ring tag lines. Approximately 2 foot of the line which is attached to the life ring and exposed to the sun is deteriorating due to exposure. 46CFR117.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: As per owner email and order form.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Post Employee Assistance Program (EAP) phone number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 10 May 2021
Resolution: Received email evidence sufficient to clear def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Provide documentation of EAP Supervisor training. A minimum of one hour is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 10 June 2021
Resolution: Received email evidence sufficient to clear def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Provide name and contact info for Substance Abuse Professional.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 10 May 2021
Resolution: Received email evidence sufficient to clear def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2021
Resolved
Replace worn flexible non-metallic hose for Port Main Engine lube oil pressure gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 13 May 2021
Resolution: Received email evidence sufficient to clear def.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 5 May 2021
Resolved
Ensure all block and tackle fittings for gangway are properly moused.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 13 May 2021
Resolution: Received email evidence sufficient to clear def.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 May 2021
Resolved
Mark all emergency exits as detailed in stated cite. Six doors require marking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 27 May 2021
Resolution: Received photographic evidence sufficienct to clear deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2020
Resolved
Replace broken shaft with one of the same adequate size and material and conduct sea trials in the presence of Coast Guard Marine Inspectors prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2021
Resolution: Witnessed satisfactory operation of shaft while underway. All associated hardware installed properly and no vibration was evident. Only a short portion of the shaft is visible from inside the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2019
Resolved
Carry only 342 adult persons until the destroyed type I PFD’s are replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel replaced destroyed PFD's. Vessel now carries PFD in accordance with COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2019
Resolved
Replace the leaking forward hold, bilge piping system, check valve.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel intalled new check valve.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 June 2019
Resolved
Install a screen on the installed bilge system pick up in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel installed screen on bilge pickup.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 27 June 2019
Resolved
Post operating and safety instructions for the MSD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel posted operating instructions in MSD Space.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 27 June 2019
Resolved
Re-install the blower motor belt guard and ensure the motor is properly wired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel reinstalled guard and properly wired motor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2019
Resolved
Remove or properly terminate the abandoned wires (old gen wires) from the overhead of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Wires terminated into electrical boxes properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2019
Resolved
Insulate both of the exposed generators exhaust flanges.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel reinstalled insulation on exhaust flanges.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 27 June 2019
Resolved
Label the “open” direction on the generator room escape scuttle.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel placed directions near egress from engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 June 2019
Resolved
Ensure the pyro is replaced prior to the expiration dates (July and Aug, 2019)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 25 July 2019
Resolution: Vessel has new pyro on board.
Fire Fighting › Structural - Horizontal Zones › General
Issued 7 May 2018
Resolved
Replace the missing overhead insulation in the generator room. There were two very small areas that were missed, approx. 3"x 6” when the insulation was re-installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2018
Resolved
Permanently support with meatal brackets the forward generator power cable to the vessel's overhead. The cable was temporarily supported with nylon line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Electrical › Electrical Distribution System (service) › Switch
Issued 7 May 2018
Resolved
Properly cover the new 24volt battery system (generator) exposed thermals on the battery selector switch. The terminals were temporarily covered.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 7 May 2018
Resolved
Properly mount the 1st deck, forward, port side, fire extinguisher bracket (upper support bolt is loose).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Engineering › Fuel Oil Service System › Piping
Issued 7 May 2018
Resolved
Provide the new generator fuel line pipe specifications to MSD Peoria.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 7 May 2018
Resolved
In lieu of actually testing the rebuilt MDE’s safeties, provide a service report that the MDE’s safeties were tested by an approved vender (Master stated the tests were completed and he was waiting for the documentation).
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 May 2018
Resolved
Carry only 315 adult passengers until the damaged PFD’s are repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Accommodation/Occupational Safety › Ventilation › General
Issued 13 March 2018
Resolved
Provide the generator room supply fan CFM to MSD Peoria.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 20 June 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 14 November 2017
Resolved
As per 46CFR176.25-50 and 46CFR 176.25-10(b); prior to placing the vessel back in service in the spring of 2018, repair or replace the leaking seals/gaskets on both the MDE's and generators. The vessel is currently in winter lay-up status.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2018
Resolution: New MDE's and Gens were installed.
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2017
Resolved
Clean the excess oil residue of the generators exhaust fan housing area.
Due 12 August 2017
Resolved 30 August 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2017
Resolved
Seal the stern void high level bilge alarm wire, bulkhead, penetration stuffing tube.
Due 12 August 2017
Resolved 30 August 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 July 2017
Resolved
Paint or better indentify the location of the emergency fuel shut off valve location.
Due 12 August 2017
Resolved 30 August 2017
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2017
Resolved
Replace the worn/deteriorated retro on all the vessel life rings.
Due 12 August 2017
Resolved 30 August 2017
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 12 July 2017
Resolved
Update the Senior Deckhand Letter.
Due 12 August 2017
Resolved 30 August 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 12 July 2017
Resolved
Provide a safety inspection and service repair report from a marine repair facility for the vessel’s MDE’s and Generators.
Due 12 August 2017
Resolved 30 August 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 July 2017
Resolved
Update the expired and missing items in the vessel’s first aid kit.
Due 12 August 2017
Resolved 30 August 2017
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 July 2017
Resolved
Update the 2017 drug and alcohol testing crew list.
Due 12 August 2017
Resolved 18 September 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 July 2017
Resolved
Determine the cause and repair as necessary the bow ramp electrical motor, (motor is tripping out).
Due 24 September 2017
Resolved 30 August 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 July 2017
Resolved
Cover the MDE’s exposed exhaust flex joints.
Due 12 August 2017
Resolved 30 August 2017
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 July 2017
Resolved
Carry only 305 adult persons until the damaged PFD’s are repaired or replaced.
Due 12 August 2017
Resolved 30 August 2017
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 July 2016
Resolved
Carry only 326 adult persons until the damaged PFD’s are repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 24 August 2016
Electrical › Lighting (service) › Conductor
Issued 13 July 2016
Resolved
Permanently wire the 3rd deck rope lighting.
Condition: Placed in Improper Service
Due 13 August 2016
Resolved 24 August 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 July 2016
Resolved
Ensure the vessel has a valid COD.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 July 2016
Resolved
Replace the 1st deck, port, bow, overhead electrical box broken cover plate.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Electrical › Electrical Distribution System (emergency) › Conductor
Issued 13 July 2016
Resolved
Properly wire the 2nd deck (amidships) overhead P/A speaker.
Due 13 August 2016
Resolved 24 August 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 13 July 2016
Resolved
Clean the entire E/R, stbd side exhaust vent.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 July 2016
Resolved
Clean under the generators and the generator room deck (oil soaked rags, tape, oil reside…).
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 July 2016
Resolved
Blanket the forward generator exposed exhaust flange.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 13 July 2016
Resolved
Ensure to 2015 MIS report was submitted by the consortium or submit the vessel report online. Once submitted ensure there is a copy available to verify 25% random test rate.
Condition: Improper/Lack of Maintenance
Due 13 August 2016
Resolved 24 August 2016
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 July 2016
Resolved
Provide a 2015 crew list to verify the 25% test rate.
Due 13 August 2016
Resolved 24 August 2016