MR. JESSIE

MR. JESSIE is a 1997 offshore supply vessel. The Coast Guard has recorded 46 inspections since 1996, most recently in August 2017, along with 36 deficiencies and 2 casualty investigations between 2009 and 2012.

Records from 1996 to 2017. Most recent: inspection, 16 August 2017.

Built
1997
Last inspected
16 August 2017
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9132208 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCX6476
448376
Flag
UNITED STATES
366282000 (licence lapsed)
Maury page id
psix-448376

Inspections, by type

…with no type recorded9
Years with a record 19 calendar years (1996–2017)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)240.9 ft × 56.0 ft × 18.8 ft
Registered tonnagegross 2,043 / net 910
ITC dimensions (L × B × D)240.9 ft × 56.0 ft × 18.8 ft
ITC tonnagegross 2,043 / net 910
BuilderNORTH AMERICAN SHIPBLDG · MORGAN CITY, LA, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 September 2026 · expires 30 September 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2416 - Dead Weight, Ton
3773 - Displacement, Ton
2043 - Convention (Subpart B), Gross Ton
910 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX6476MMSI 366282000 · expired · compulsorily equipped · granted 8 May 2007, cancelled 30 September 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TOP RICH Freight Ship · MISLE 479429 · 1 April 2009 · activity 3912007

Inspection history · 46

16 August 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6242492
3 May 2016 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5867734
24 August 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5224755
5 August 2015 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5206012
10 July 2012 Internal Structural Exam · Hull Examination · Cargo Tank Internal · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4374593
28 December 2010 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3926463
14 December 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3910412
17 November 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3903741
1 April 2009 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3444247
1 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3912007
25 March 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439801
18 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3419992
22 July 2008 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3275605
23 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245287
20 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3211711
11 October 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3077605
11 July 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2992343
31 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2815500
11 September 2006 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2775806
31 July 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2731897
31 July 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2731926
30 May 2006 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2664076
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501601
9 August 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2456777
14 June 2005 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2419591
12 May 2005 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2355658
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293946
15 November 2004 Annual Inspection · MTSA/ISPS Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2241389
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979515
26 August 2003 Construction Oversight · Inclining Experiment · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1879584
7 March 2003 Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1756464
29 August 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1668198
27 August 2002 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1664520
18 July 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436600
10 September 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 133065
8 June 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050581
30 May 2000 Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448120
11 August 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457686
18 October 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 16958
25 August 1998 Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437449
14 May 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793372
8 April 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 788871
5 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 185160
11 August 1997 Initial Construction-Excluding Oversight · Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409734
1 August 1997 Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117721
11 October 1996 Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419674

Deficiency record · 36

Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 May 2016 Resolved
Provide proof of annual fire extinguishing equipment servicing completed in accordance with 46 CFR 132.350.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Equipment servicing reports provided to USCG MI.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 3 May 2016 Resolved
Remove flexible hose in overhead from forward engineer passage to main deck, and flexible oil service hose in overhead from forward bow thruster to engine room.
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 5 May 2016
Resolution: Flexible hose removed.
Electrical › Electric Generation Source (emergency) › Generator
Issued 3 May 2016 Resolved
Prove proper operation of the emergency generator to the satisfaction of the attending USCG Marine Inspector or ABS Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2016
Resolved 5 May 2016
Resolution: Satisfactory operational test of emergency generator witnessed by ABS surveyor.
Engineering › Pressure Vessel › Relief Valve
Issued 3 May 2016 Resolved
Renew or replace safety relief valve for bulk air receiver in accordance with 46 CFR 54.15.
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 5 May 2016
Resolution: Witnessed installation of safety relief valve meeting 46 CFR 54.15.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 24 August 2015 Resolved
Two studs were broken off around the fwd peak hatch.
Due 24 September 2015
Resolved 8 September 2015
Resolution: Yard welded new studs, tested sat.
Lifesaving › Rescue Boat › Propulsion Casing/Protection
Issued 24 August 2015 Resolved
The guard around the propeller is broke.
Due 24 September 2015
Resolved 8 September 2015
Resolution: Replaced prop guard, all sat.
Construction/Loadline › Hull › Hull Plating
Issued 1 April 2009 Resolved
Noted damage below port side freeboard deck heading aft to stern 10' with 3"-4" insets. Internally, damage would be at the aft port peak balancing tank. There is possible damage to internal members in way of the externally damaged area. A CG835 is issued requiring the tank be made available to a Marine Inspector for inspection.
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 8 April 2009
Resolution: Damage repaired and inspected by ABS survey as acceptable to class and accepted by CG.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 11 September 2006 Resolved
Service both Pressure/Vacumn valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 22 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2006 Resolved
Show Intrinsic Safety rating of installed Pressure Relay devices that are located aft of each PV vent.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 22 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2006 Resolved
Remove non-approved Zenner Barrier blocks located in the Methanol Junction box in the lower passageway.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 22 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2006 Resolved
Renew wiring and block in Stbd Main Deck "J" Box inside hazard zone.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 22 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2006 Resolved
Renew damaged wiring in Port Main Deck "J" Box inside hazard zone.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 22 July 2008
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 9 August 2005 Resolved
Correctly install all Hydro-static relaese mechanisms for Life Rafts.
Condition: Improper Installation
Due 9 September 2005
Resolved 17 November 2005
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 9 August 2005 Resolved
Install fixed containment of 42 gallon capacity for emergency generator fuel vent, oil foot seal vent and liquid mud fill line.
Condition: Improper Installation
Due 28 August 2007
Resolved 15 August 2007
Electrical › Electrical Distribution System (service) › Switch
Issued 9 August 2005 Resolved
Locate controller for fuel oil centerfuge to position so that the centerguge can be observed from the controller.
Condition: Improper Installation
Due 9 September 2005
Resolved 17 November 2005
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 August 2005 Resolved
Show proper operation of the Oily Water seperator prior to pumping bilge slops.
Condition: Unknown
Due 9 September 2005
Resolved 17 November 2005
Documentation › Manuals/Policy Documentation
Issued 26 August 2003 Resolved
Provide vessel with a SOLAS Training Manual. LEGACY COMPONENT DESC: Training Manual (lifesaving)
Action required: 705 - Other - as specified
Due 26 September 2003
Resolved 26 September 2003
Navigation › Piloting/Steering
Issued 26 August 2003 Resolved
Provide vessel with a new deviation table. LEGACY COMPONENT DESC: Deviation Table/Graph
Action required: 705 - Other - as specified
Due 26 September 2003
Resolved 26 September 2003
Navigation › Piloting/Steering
Issued 26 August 2003 Resolved
Provide the vessel with a new maneuvering data placard. LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Action required: 705 - Other - as specified
Due 26 September 2003
Resolved 26 September 2003
Communications › Radio Communications
Issued 26 August 2003 Resolved
Replace hydrostatic release on the EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2003
Resolved 1 September 2003
Fire Fighting › Firemans Outfit
Issued 26 August 2003 Resolved
Provide SOLAS approved flashlights for the fireman outfits. LEGACY COMPONENT DESC: Lantern (Electric Safety Lamp)
Action required: 705 - Other - as specified
Due 26 September 2003
Resolved 26 September 2003
Deck/Cargo › Vapor Control Systems
Issued 26 August 2003 Resolved
Replace the flame screen in vent on the 01 deck. LEGACY COMPONENT DESC: Flame Screens
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2003
Resolved 1 September 2003
Fire Fighting › Fixed Fire Detection System
Issued 26 August 2003 Resolved
Replace the batteries in the fire detection system. LEGACY COMPONENT DESC: Power Supply
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2003
Resolved 1 September 2003
Fire Fighting › Nozzles
Issued 26 August 2003 Resolved
Provide a 95 GPM vari-nozzle for use with the AFFF. LEGACY COMPONENT DESC: Type
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2003
Resolved 1 September 2003
Communications › Alarms/Indicators
Issued 26 August 2003 Resolved
Repair stbd. propeller RPM gauge. LEGACY COMPONENT DESC: Propeller Revolutions Rate Indicator
Action required: 705 - Other - as specified
Due 26 September 2003
Resolved 26 September 2003
Fire Fighting › Ventilation Systems
Issued 26 August 2003 Resolved
Repair fire damper for supply air to the emergency generator space. LEGACY COMPONENT DESC: Damper
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2003
Resolved 1 September 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 7 March 2003 Resolved
RENEW BATTERIES IN ALL EMERGENCY LIGHTS IN PORTABLE QUARTERS. LEGACY COMPONENT DESC: LIGHTING
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2003
Resolved 7 March 2003
Electrical › Electric Supply System (service)
Issued 29 August 2002 Resolved
PROVIDE PROPER BATTERY INSTALLATION LOCATED ON THE 02 DECK LEVEL CLOSET. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 29 September 2002
Resolved 26 August 2003
Resolution: Batteries were moved to a seperate storeroom away from the A/C intake.
Engineering
Issued 30 May 2000 Resolved
Repair insulation on fuel manifold valve electric actuators prior to using remote controls.
Condition: Unknown
Due 2 June 2000
Resolved 3 June 2000
Deck/Cargo
Issued 30 May 2000 Resolved
Prior to loading cargo in #1 P (4642A) & S (4642D), #2 S (4642E) & #3 P (4642C) dry bulk tanks provide documentation of: repairs, tanks still withing ASME spec and are safe for use.
Condition: Unknown
Due 8 June 2000
Resolved 9 June 2000
Navigation
Issued 30 May 2000 Resolved
Install continously recording device for depth sounder and prove proper operation of same..
Condition: Unknown
Due 2 June 2000
Resolved 3 June 2000
Navigation
Issued 25 August 1998 Resolved
IN ACCORDANCE WITH TITLE 33 CFR 164.35, INSTALL AN ECHO DEPTH SOUNDING DEVICE WHICH RECORDS READINGS.
Condition: Unknown
Due 15 September 2015
Resolved 15 September 2015
Navigation
Issued 25 August 1998 Resolved
IN ACCORDANCE WITH 33 CFR 164.35(g)(1)thru (7), PROVIDE NAVIGATION MANEUVERING INFORMATION: TURNING DIAGRAM, TIME DISTANCE STOP DATA, BOW/DROP THRUSTER SPEED TABLES, NORMAL LOAD AND BALLAST TABLES AND BLOCK DIAGRAM FOR STEERING CHANGEOVER ON BRIDGE.
Condition: Unknown
Due 15 September 2015
Resolved 15 September 2015
Navigation
Issued 11 August 1997 Resolved
In accordance with Title 33 Code of Federal Regulations part 164.35, install and prove proper operation of a gyro compass with repeater, an echodepth sounding device which records readings and a device which supplies visual compass readings to the emergency steering station.
Condition: Unknown
Due 15 September 2015
Resolved 15 September 2015
Navigation
Issued 11 August 1997 Resolved
In accordance with Title 33 Code of Federal Regulations part 164.35(g)(1) through (7), provide navigation maneuvering information: turning diagram, time/distance stop data, bow/drop thruster speed tables, normal load and ballast tables and a block diagram for steering changeover on the bridge.
Condition: Unknown
Due 15 September 2015
Resolved 15 September 2015
Lifesaving
Issued 11 August 1997 Resolved
INSTALL AND PROVE PROPER OPERATION OF AN ADJUSTABLE HEIGHT RESCUE PLATFORM.VESSEL DRAFT IS LIMITED BETWEEN 10.5' AND SUMMER LOADLINE UNTIL REQUIREMENTSATISFIED BY AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 September 2015
Resolved 15 September 2015

Casualty record · 2

1 April 2009Routine · role: Involved in a Marine Casualty · activity 3912007
6 August 2012Routine · role: Involved in a Marine Casualty · activity 4403204
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.