MAURY USCG vessel records
← All vessels

C-CAPTAIN

Built
1996
Last inspected
30 July 2020
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 July 2020
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9132155
WCW9590
448377
Flag
UNITED STATES
Maury page id
psix-448377

Documentation record

Registered dimensions (L × B × D)240.9 ft × 56.0 ft × 18.8 ft
Registered tonnagegross 2,042 / net 908
ITC dimensions (L × B × D)240.9 ft × 56.0 ft × 18.8 ft
ITC tonnagegross 2,042 / net 908
BuilderNORTH AMERICAN SHIPBLDG · LAROSE, LA, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 23 October 2025 · expires 30 November 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2462 - Dead Weight, Ton
2042 - Convention (Subpart B), Gross Ton
908 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 10 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

30 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7019933
16 July 2018 Periodic Inspection · Administrative Inspection · MTSA/ISPS Verification · Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6480958
5 April 2018 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6386139
24 July 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6219677
18 January 2017 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6075872
31 May 2016 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5891692
26 May 2016 Internal Structural Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5888619
23 May 2016 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5885064
20 May 2016 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5885328
16 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5878601

Deficiency record · 9

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 July 2018 No resolution recorded
Grounding cables at methanol flanges both Port and STBD corroded and or broke. Replace prior to loading methanol.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 July 2018 Resolved
Door to laundry room required to be A-60. Door was removed. Replace door prior to returning to service.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2018
Resolved 18 July 2018
Resolution: Door replaced.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 24 July 2017 Resolved
Found 10 life jackets with expired lights. Provide lights for life jackets.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 August 2017
Resolution: Received verification of 10 new lifejacket lights
Construction/Loadline › Structures › Door
Issued 24 July 2017 Resolved
Engine room escape hatch was not watertight. Make engine room hatch watertight.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 July 2017
Resolution: Corrected by vessel, verified by ABS
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 24 July 2017 Resolved
Methanol tank level indicating light was inoperable and in a continuous alarm state. Provide operable light prior to carriage of methanol.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2017
Resolution: Vessel repaired light.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 July 2017 Resolved
Lighting within Hazard zone was not explosion proof/intrinsically safe. Provide Class I Division I fixtures. Prior to carriage of methanol.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2017
Resolution: Vessel installed new Class I/Div I fixtures.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 24 July 2017 Resolved
#3 STBD generator did not have operable overspeed device. Provide operable overspeed device.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 July 2017
Resolution: Corrected prior to completion of inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2016 Resolved
The self-igniting light (161.010) for 01 deck lifebuoy is cracked at seal; vessel to replace prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2016
Resolved 1 June 2016
Resolution: Self-igniting light was replaced by new light approved under 161.010.
Fire Fighting › Fire Hoses › Condition
Issued 31 May 2016 Resolved
Fire hose ruptured during operational test. Replace with approved fire hose.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2016
Resolved 31 May 2016
Resolution: Fire hose replaced with approved fire hose.

Ownership record