MAURY USCG vessel records Sign in
← All vessels

VOSTOK

VOSTOK is a 1996 freight ship. The Coast Guard has recorded 17 inspections since 1996, most recently in July 2011, along with 7 deficiencies and 1 operational control.

Records from 1996 to 2011. Most recent: operational control imposed, 18 July 2011.

Built
1996
Last inspected
18 July 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9135482 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
448509
Flag
LIBERIA
—
Maury page id
psix-448509

Inspections, by type

…with no type recorded12
Years with a record 9 calendar years (1996–2011)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it14754 - Convention (Subpart B), Gross Ton
7920 - Convention (Subpart B), Net Ton
23524 - Dead Weight, Ton
29089 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

18 July 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4085659
14 July 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4081060
21 August 2003 MARPOL Annex I Examination · Re-Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1878617
2 July 2003 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1833475
27 January 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1734564
16 August 2002 Ballast Water Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1658947
12 December 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 296121
22 October 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 294727
26 March 2001 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 288511
12 October 2000 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 282868
28 February 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 275138
17 November 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 434890
10 December 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 423359
17 October 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 421635
28 July 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 418510
3 December 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 410374
12 November 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 397267

Deficiency record · 7

Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 August 2003 Resolved
Update Fire Control Plan to reflect that doors from mess rooms into galley are class A-0 doors, which are currently labeled as class B-0 doors. Solas 74 AMEND II-2/20. LEGACY COMPONENT DESC: Decks - Main Galleys
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2011
Resolution: PSCO reviewed and accepted fire control plan that reflected the proper A-0 class fire doors around galley.
Engineering › Steering Gear System
Issued 27 January 2003 Resolved
Investigate cause and repair as original the steering gear where system hunts approximately 3 degrees.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2003
Resolution: Repaired to the satisfaction of class.
Documentation › Logs/Records
Issued 27 January 2003 Resolved
Include the W.O. tanks, capacity 1.5 m3 each, in the C-11 entries in the oil record book. LEGACY COMPONENT DESC: Oil Record Book
Action required: 15 - Rectify deficiencies by next port
Due 28 January 2003
Resolved 2 July 2003
Documentation › Logs/Records
Issued 27 January 2003 Resolved
Ensure that there is not free communication between #1 and #2 W.O. tanks and treat each tanks individually in the oil record book when recording the fluid levels. LEGACY COMPONENT DESC: Oil Record Book
Action required: 15 - Rectify deficiencies by next port
Due 28 January 2003
Resolved 2 July 2003
Fire Fighting
Issued 22 October 2001 Resolved
The instructions for operating the vessel's fixed CO2 fire extinguishing system direct the operator to open a control box in order access the cargo area selection valves. With the vessel's current valve arrangement, there is no box or similar device surrounding the cargo area selection valves.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 17 November 1999 Resolved
WHILE CONDUCTING A FIRE DRILL ON THE VESSEL IT WAS FOUND THAT THE GALLEY SERVING WINDOW DOOR NOT ABLE TO CLOSE, DOOR IS A FIRE DOOR._x001C_ (SOLAS 74(AMENDED)II-2/47.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Lifesaving
Issued 28 July 1998 Resolved
The vessels free-fall lifeboat had not been tested at least once per year as required in SOLAS Chapter III, Regulation 18, Paragraph 3.6 and in accordance with the vessels SMC issued by NKK on behalf of Panama. _x001C_ Correct prior to next U.S. port.
Condition: Unknown
Due 17 October 1998
Resolved 17 October 1998

Ownership record