LIMAR

LIMAR is a 1996 tank ship. The Coast Guard has recorded 3 inspections since 2016, most recently in April 2017, along with 6 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2017. Most recent: inspection, 20 April 2017.

Built
1996
Last inspected
20 April 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9121003
448511
Flag
MARSHALL ISLANDS
Maury page id
psix-448511

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…past their stated due date2
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it46170 - Dead Weight, Metric Ton
55874 - Displacement, Metric Ton
28357 - Convention (Subpart B), Gross Ton
12549 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

20 April 2017 MARPOL Annex II Examination · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6128959
14 April 2017 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6119609
19 January 2016 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5799323

Deficiency record · 6

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 14 April 2017 Resolved
1850-Fire protection cargo deck area-One of the two IGG fuel oil pump's supply valve was found to be leaking. Prior to carriage of cargo requiring inert gas. 74 SOLAS (97) II-2/62.7.2(ac).
Action required: 705 - Other - as specified
Resolved 16 April 2017
Resolution: Received class report from BV attesting to proper repairs to the fuel oil valves.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 14 April 2017 No resolution recorded
1850-Fire protection cargo deck area-At least two blowers for IGG shall be capable of delivering inert gas to the cargo tanks. #2 blower could not be operated by crew remotely as designed. Prior to carrying cargoes requiring inert gas. 74 SOLAS (97) II-2/62.7.1 (ac)
Action required: 705 - Other - as specified
Due 15 July 2017 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 14 April 2017 Resolved
1999-Other MARPOL Annex II-Types of gauging for individual products are shown in column j in the table of Chapter 17. PSCO observed closed gauging for #4 Stbd tank to be inoperable. Prior to carriage of cargoes requiring closed gauging. IBC 13.1.4 (ac)
Action required: 705 - Other - as specified
Resolved 16 April 2017
Resolution: Received class report from BV attesting to proper repairs.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 14 April 2017 No resolution recorded
1850-Fire protection cargo deck area-PSCO observed temporary repair on IGG shell is leaking. Prior to carriage of cargo requiring inert gas. 74 SOLAS (14) I/11(a).
Action required: 705 - Other - as specified
Due 15 July 2017 — due date passed with no resolution recorded
Operations/Management › Pollution › SECA
Issued 14 April 2017 Resolved
2420-Change-over procedures-PSCO observed ships change over procedures did not reflect actual shipboard records with regards to time requirements of changeover from high sulfur to low sulfur. MARPOL (2011) Annex VI/14.6(40ac)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2017
Resolution: Received class report from BV satisfying requirement.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 14 April 2017 Resolved
1899-Other (tankers)-PSCO observed the high level alarm did not activate when tested for #6 Port. 46 CFR 39.2007(c)(1)-10c
Action required: 705 - Other - as specified
Resolved 14 April 2017
Resolution: Crew corrected high level alarm prior to completion of exam.

Ownership record