MAURY USCG vessel records Sign in
← All vessels

LIMAR

LIMAR is a 1996 tank ship. The Coast Guard has recorded 54 inspections since 1996, most recently in April 2017, along with 30 deficiencies — 3 with no resolution recorded — and 12 operational controls, 1 with no removal date recorded.

Records from 1996 to 2017. Most recent: inspection, 20 April 2017.

Built
1996
Last inspected
20 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9121003 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
448511
Flag
MARSHALL ISLANDS
—
Maury page id
psix-448511

Inspections, by type

…with no type recorded22
…past their stated due date2
Years with a record 12 calendar years (1996–2017)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it46170 - Dead Weight, Metric Ton
55874 - Displacement, Metric Ton
28357 - Convention (Subpart B), Gross Ton
12549 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 54

20 April 2017 MARPOL Annex II Examination · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6128959
14 April 2017 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6119609
19 January 2016 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5799323
15 July 2011 COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4082106
4 July 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4076124
2 July 2011 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4065074
7 February 2011 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3940457
24 January 2011 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3930399
2 December 2010 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3902965
14 November 2010 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3891021
6 October 2010 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3861371
4 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3523061
3 July 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3522250
27 September 2007 ISPS II Exam · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3067162
26 September 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3066800
4 September 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3049071
13 January 2007 Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2855160
1 June 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2376206
17 May 2005 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2360690
5 April 2005 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2327002
11 March 2005 Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2308423
10 March 2005 Deficiency Check · ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2307706
6 March 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2304703
28 February 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2301039
7 February 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2287746
21 October 2004 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2225460
4 October 2004 ILO-147 Exam · Loadline Exam · PII Safety Exam · MARPOL Annex I Examination · STCW 95 Exam · COC-TVE Renew · MARPOL Annex V Examination · ISPS III Exam · ISM Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2208435
19 August 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2170309
19 August 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2170450
15 August 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2166282
14 August 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2165912
26 April 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2054719
22 April 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2049834
16 April 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2053694
25 November 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1954686
27 October 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1936974
14 October 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1927937
25 September 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1912806
23 September 2003 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1911008
22 September 2003 MARPOL Annex I Examination · Letter of Compliance (Initial/Renewal)
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1908698
30 December 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1724431
20 August 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1663967
14 August 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1661246
3 January 2002 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1475201
20 October 2001 Type not recorded
No type recorded · GROUP BOSTON · USCG Northeast District (CGD-NE) · Activity 1610882
12 August 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 292798
27 July 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 292560
6 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 290722
6 June 2001 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1067917
29 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 290463
29 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 290577
29 May 2001 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1451716
27 November 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 397960
27 November 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1094548

Deficiency record · 30

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 14 April 2017 Resolved
1850-Fire protection cargo deck area-One of the two IGG fuel oil pump's supply valve was found to be leaking. Prior to carriage of cargo requiring inert gas. 74 SOLAS (97) II-2/62.7.2(ac).
Action required: 705 - Other - as specified
Resolved 16 April 2017
Resolution: Received class report from BV attesting to proper repairs to the fuel oil valves.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 14 April 2017 No resolution recorded
1850-Fire protection cargo deck area-At least two blowers for IGG shall be capable of delivering inert gas to the cargo tanks. #2 blower could not be operated by crew remotely as designed. Prior to carrying cargoes requiring inert gas. 74 SOLAS (97) II-2/62.7.1 (ac)
Action required: 705 - Other - as specified
Due 15 July 2017 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 14 April 2017 Resolved
1999-Other MARPOL Annex II-Types of gauging for individual products are shown in column j in the table of Chapter 17. PSCO observed closed gauging for #4 Stbd tank to be inoperable. Prior to carriage of cargoes requiring closed gauging. IBC 13.1.4 (ac)
Action required: 705 - Other - as specified
Resolved 16 April 2017
Resolution: Received class report from BV attesting to proper repairs.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 14 April 2017 No resolution recorded
1850-Fire protection cargo deck area-PSCO observed temporary repair on IGG shell is leaking. Prior to carriage of cargo requiring inert gas. 74 SOLAS (14) I/11(a).
Action required: 705 - Other - as specified
Due 15 July 2017 — due date passed with no resolution recorded
Operations/Management › Pollution › SECA
Issued 14 April 2017 Resolved
2420-Change-over procedures-PSCO observed ships change over procedures did not reflect actual shipboard records with regards to time requirements of changeover from high sulfur to low sulfur. MARPOL (2011) Annex VI/14.6(40ac)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2017
Resolution: Received class report from BV satisfying requirement.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 14 April 2017 Resolved
1899-Other (tankers)-PSCO observed the high level alarm did not activate when tested for #6 Port. 46 CFR 39.2007(c)(1)-10c
Action required: 705 - Other - as specified
Resolved 14 April 2017
Resolution: Crew corrected high level alarm prior to completion of exam.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 July 2011 Resolved
The radar was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2011
Resolved 9 July 2011
Resolution: Received, reviewed and accepted tech report stating the radar was replaced, tested and found satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 6 October 2010 Resolved
Vessel has not completed static liquid pressure test to 1.5 times maximum allowable working pressure within the past 12 months on cargo piping. 33CFR156.170 Rectify deficiencies prior to next U.S. port after sailing foreign to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 November 2010
Resolution: Received company report attesting vessel tested cargo piping to 1.5 times MAWP while underway and test sat.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 July 2009 Resolved
The vessel's 3cm Radar was found unoperational. A technician attended the vessel and was unable to fix radar before vessel's departure. A deviation was granted to depart Mississippi River.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 July 2009
Resolution: While at PRSI Terminal vessel replaced secondary radar and submitted tech report. Vessel cleared for departure.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 May 2005 Resolved
High pressure, saltwater cooling pipe, 5" diameter, has a large soft patch and is leaking. Crew has pre-fabricated replacement pipe. class report required.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 May 2005
Resolved 1 June 2005
Resolution: A class report was received, stating that the deficiency was rectified.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 11 March 2005 Resolved
Seating "O" rings on 5P and 3S found to be inoperable. Provide corrective action reqport ad class report prior to cargo operations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 April 2005
Resolved 6 April 2005
Resolution: Received copy of class report indicating that the "O" rings on 5P and 3S have been renewed and a copy or there Corrective action report.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 February 2005 Resolved
The subject vessel wishes to depart the Port of New York on or about February 4, 2005 with an inoperable secondary radar and has arranged to effect repairs prior to entering the next U.S. Port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: PSC Boarding Officers conducted an operational test of the secondary radar with satisfactory results.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 4 October 2004 Resolved
Prove proper operation of IGS atmospheric vent off top of the deck seal, to the satisfaction of the class society, and prior to arrival at the next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 21 October 2004
Resolution: Recieved class report from DNV satisfying requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 August 2004 Resolved
10Aug04: Vessel reported secondary radar not working properly. Provide attestation that satisfactory repairs were made to the secondary radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2004
Resolution: 14Aug04: Recieved technician''s report attesting to satisfactory repairs made to the secondary radar. Vess
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 April 2004 Resolved
Secondary marine radar inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2004
Resolution: Received technician''s report attesting to satisfactory repairs to secondary marine radar.
Deck/Cargo › Vapor Control Systems
Issued 22 September 2003 Resolved
Make permanent repairs to sight glass on P/V Breaker . Need to repair with glass. to Sat of class. Hourly rounds to be conducted and logged. LEGACY COMPONENT DESC: Vessel Vapor Overpressure/Vacuum Protection
Action required: 15 - Rectify deficiencies by next port
Resolved 25 September 2003
Resolution: Received class survey stating that it was repaired and tested
Deck/Cargo › Inert Gas System
Issued 22 September 2003 Resolved
Make permanent repairs to the feed water line for the misters on the scrubber. To the sat of class. Hourly rounds to be conducted and logged. LEGACY COMPONENT DESC: Scrubber
Action required: 15 - Rectify deficiencies by next port
Resolved 25 September 2003
Resolution: Received class report stating that it has been repaired and tested.
Construction/Loadline › Structures
Issued 22 September 2003 Resolved
Make permanent repairs to the deck catwalks to orginal construction. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 22 October 2003
Resolved 27 October 2003
Resolution: Received photos of repair from vessel.
Engineering
Issued 22 September 2003 Resolved
All Empty Oil Drums in steering gear flat must be remved prior to departure from St. Croix LEGACY COMPONENT DESC: Steering flat
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2003
Resolution: Received e-mail stating that the empty drums were removed from the master.
Engineering › Diesel Engine (auxiliary)
Issued 22 September 2003 Resolved
Make permant repairs to the soft patch on the MDE Heat Exchanger. To Sat of the Class. Hourly round must be conducted and logged. LEGACY COMPONENT DESC: Heat Exchanger
Action required: 15 - Rectify deficiencies by next port
Resolved 25 September 2003
Resolution: Received class report stating that it was repaired and tested.
Deck/Cargo
Issued 20 August 2002 No resolution recorded
Make proper repairs to the starboard ballast tank vent screen.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: sat
Pollution Prevention/Response
Issued 14 August 2002 Resolved
Prior to departure from U.S. Waters (Puerto Rico), make proper repairs to the O.D.M.E. Vessel is permitted to transit from St. Croix to San Juan.
Action required: 705 - Other - as specified
Resolved 14 August 2002
Deck/Cargo
Issued 14 August 2002 Resolved
Make proper repairs to the I.G.S. O2 content meter in the cargo control room.
Action required: 705 - Other - as specified
Due 28 August 2002
Resolved 14 August 2002
Lifesaving
Issued 14 August 2002 Resolved
Freshen PFD instructions on the chemical store locker
Due 28 August 2002
Resolved 14 August 2002
Fire Fighting
Issued 29 May 2001 Resolved
FOAM ANALYSIS OUT OF DATE. PROVIDE FAX OF THE ANALYSIS PRIOR TO DEPARTURE.
Condition: Unknown
Due 12 August 2001
Resolved 12 August 2001
Construction/Loadline
Issued 29 May 2001 Resolved
LOADLINE ON STARBOARD SIDE NOT PROPERLY PAINTED. PAINT LOADLINE MARKING IN ACCORDANCE WITH ILLC CERTIFICATE NO LATER THAN 01JUL01 TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Deck/Cargo
Issued 29 May 2001 Resolved
INERT GAS REGULATING VALVE NOT OPERATING . VALVE NOT CLOSING, INDICATING LIGHTS NOT OPERATING. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO CONDUCTING OPERATIONS OR MOVING VESSEL FROM ANCHORAGE. CLEARED PRIOR TO DEPARTURE.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Deck/Cargo
Issued 29 May 2001 Resolved
INERT GAS READING ON CARGO TANKS 8C, 5S AND 6S ABOVE 8%, NEGATIVE PRESSURE READING ON 8C. INERT ALL TANKS WITH 8% INERT GAS PRIOR TO MOVING THE VESSELFROM ANCHORAGE. CLEARED PRIOR TO DEPARTING.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Deck/Cargo
Issued 27 November 1996 Resolved
Label overfill alarm. (46 CFR 39.20)
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Deck/Cargo
Issued 27 November 1996 Resolved
Provide audible alarm for overfill device alarm on main deck. 46 CFR 39.20
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.