Records from 2016 to 2024. Most recent: inspection, 3 July 2024.
Inspection history · 14
3 July 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7948001
31 July 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7757096
20 March 2023
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7646728
8 June 2022
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7421875
11 May 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7194102
6 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999394
12 March 2020
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925928
15 January 2020
Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6890046
30 April 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6747421
2 April 2019
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6654188
22 March 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6646649
1 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6409736
31 March 2017
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6128467
19 April 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5856992
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 July 2024
No resolution recorded
If your vessel is not operated on international voyages and does not meet the conditions in paragraph (d) of this section, it must undergo a drydock and internal structural examination as follows unless it has been approved to undergo an underwater survey (UWILD) per § 176.615 of this part:(1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years... Marine Inspector observed that vessel did not undergo required drydock. Vessel is restricted from carriage of passengers until satisfactory drydock examination.
46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 20 March 2023
Resolved
Provide repair plan for loose framing and failed structure around forward hatch.
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Verified satisfactory repair in accordance with approved repair plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2023
Resolved
Machinery installation must be suitable for its intended use. Provide repair plan for hydraulic lines going from Engine Room to Anchor Windlass that are beyond acceptable corrosion limits.
46CFR182.100
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Verified satisfactory repair in accordance with approved repair plan. Operator removed all hydraulic lines and sealed all bulkhead penetrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2023
Resolved
Piping for vital systems must be composed of ferrous materials. Provide repair plan for three sections of bilge piping in the forward are of the engine room with soft patches.
46CFR182.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Verified satisfactory repair in accordance with approved repair plan. Operator installed all new piping and check valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 March 2023
Resolved
Machinery installation must be suitable for its intended use. Provide repair plan for inoperable fuel tank room bilge suction that failed to operate due to failed check valve.
46CFR182.100
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Verified satisfactory repair in accordance with approved repair plan. Operator replaced check valve and demonstrated operation by pumping out space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 March 2023
Resolved
A positive shutoff valve must be installed at the hull penetration. Provide overboard valves for both submersible bilge pumps located in the lazarrette. One did not have a valve installed and the other's handle was wasted off.
46CFR182.520(e)(7)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Verified satisfactory repair in accordance with approved repair plan. Operator replaced valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 March 2023
Resolved
Provisions shall be made for closing all supply and discharge openings for a space protected by a gas system. Provide ventilation closures for engine room.
46CFR182.465(g)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Verified satisfactory repair in accordance with approved repair plan. Operator installed sliding ventilation dampers.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 March 2023
Resolved
Secure reach rod to handle of collision bulkhead securing valve.
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Verified satisfactory repair in accordance with approved repair plan. Reach rod secured to valve.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 March 2023
Resolved
The vessel will have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have emergency instructions.
46CFR185.510(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Verified posted satisfactory emergency instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2023
Resolved
Each life float may be used as long as it is in good and serviceable condition. Life float is wasted and not serviceable. Remove and destroy to satisfaction of Marine Inspector.
46CFR180.15
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Witnessed destruction of life float. Operator ordered new life float. Will amened COI once operator recieves and installs apporved life float.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 20 March 2023
Resolved
Replace expired Asprin in medical kit.
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Asprin replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2023
Resolved
Fire Boy engine shutdown and override test, Underway Test and Drills, and fuel tank room bilge suction must be test prior to issuance of COI.
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Completed underway sea trial, man overboard drills, bilge test, and fire boy tests.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 6 July 2020
Resolved
Each life float/buoyant apparatus shall have lifelines and pendants IAW 46CFR160.010. Lifelines and pendants are deterioratied. 46CFR180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2020
Resolved 23 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2020
Resolved
Ring life buoys shall have a lifeline on at least one and be IAW 46CFR160.150. Lifeline and grab-lines were deteriorated and the life buoy showed signs of damage/cracking. 46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2020
Resolved 23 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2020
Resolved
Electrical connections shall be made in an enclosure. Multiple connections were not in enclosures, to include all bilge pumps/high level alarms. 46CFR183.340(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2020
Resolved 7 August 2020
Resolution: Received photos of newly installed enclosures.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 1 May 2018
Resolved
Vessel must create a company drug and alcohol policy and keep on board with other paper work.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: vessel provided company drug and alcohol policy
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 1 May 2018
Resolved
Vessel must get alcohol testing devices and keep on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: vessel provided alcohol testing devices
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 May 2018
Resolved
Vessel needs new coast pilot, light list,and corrected and up to date charts of the area of operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: vessel provided all required up to date navigational pubs and chart.
Operations/Management › Navigation Safety › Requirements for Vessels at Anchor
Issued 1 May 2018
Resolved
Vessel needs an all round white light to meet 33CFR84 regulations. (2 mile visability)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: vessel provided all round light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 April 2016
Resolved
Provide first aid kit IAW 184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 22 April 2016
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 19 April 2016
Resolved
Provide Random Drug Testing results.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 4 May 2016
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 April 2016
Resolved
Two kapok life jackets failed. Replaced on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 19 April 2016