MAURY USCG vessel records Sign in
← All vessels

BALTIMAR ZEPHYR

BALTIMAR ZEPHYR is a 1995 freight ship. The Coast Guard has recorded 51 inspections since 1996, most recently in February 2016, along with 33 deficiencies and 18 operational controls.

Records from 1996 to 2016. Most recent: inspection, 1 February 2016.

Built
1995
Last inspected
1 February 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9125152 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP5662
448968
Flag
PANAMA
—
Maury page id
psix-448968

Inspections, by type

…with no type recorded32
Years with a record 14 calendar years (1996–2016)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5026 - Dead Weight, Ton
7002 - Displacement, Ton
3572 - Convention (Subpart B), Gross Ton
1879 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 51

1 February 2016 Ballast Water Examination · ISPS II Exam · PI Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5807095
28 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5805500
10 December 2015 ISPS III Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5779519
8 August 2015 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5209244
8 August 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5213040
24 July 2015 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5194178
19 January 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4225811
13 January 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4219102
6 August 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4094902
24 November 2010 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3898344
19 November 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3894547
29 April 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3193193
18 July 2007 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2999142
27 April 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2916798
2 May 2006 NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2638817
28 April 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2635668
11 April 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2621912
23 January 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2571438
26 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2280925
10 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2271939
6 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2269742
15 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2259631
11 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2257313
4 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2253154
24 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2247656
4 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2234469
31 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2232282
29 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2230684
18 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2225543
15 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2221274
14 September 2004 PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2195266
11 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2128703
7 May 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2067840
14 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2024872
8 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2020743
6 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2019391
17 February 2004 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2007483
1 December 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1956620
11 August 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1872927
25 June 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1821601
6 June 2003 Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1811096
31 October 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 283751
5 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282831
22 March 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276032
8 March 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 186762
8 March 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 275387
17 September 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 432916
8 September 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 53422
26 December 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 208535
26 December 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765803
29 October 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 396873

Deficiency record · 33

Construction/Loadline › Structures › Superstructure
Issued 17 December 2015 Resolved
ICLL(88 proto)8 Reg 25.3 Guard rails fitted on superstructure and free board decks shall have at least three courses. The guard rail on the forward peak was missing one of its courses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2015
Resolved 19 December 2015
Deck/Cargo › Mooring/Anchoring › Winch
Issued 17 December 2015 Resolved
74SOLAS(2004 cons) II-I/3-1 Ships shall be maintained in compliance with the mechanical requirements of a classification society which is recognized by the administration. The pressure gauge on the hydraulic pump for the mooring winch is broken.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 January 2016
Resolved 19 December 2015
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 10 December 2015 Resolved
74SOLAS (2014 cons) IX/3.1 ISM Code Part A/11. Recommend an external audit of the company's DOC and SMS. Excessive leaks in stearing gear room, sewage leak, maintenance of fire doors,excessive fuel leaks, general cleanliness of engine room, disengaged alarms in engine room and water leaking from generator. The condition of equipment does not indicate maintenance is being done. See form B for more.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2015
Resolution: ISM audit conducted 21DEC2015
Personnel › Certificates/Documents/Licenses › STCW Certificate, Chief Engineer Officer
Issued 10 December 2015 Resolved
STCW A-III/2.1 The port state team was unable to assess the condition/operation of the engine room and competency of the chief engineer and second engineer based on refusal to speak to the Coast Guard team and failed to provide engine room documents.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2015
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 10 December 2015 Resolved
74SOLAS(04cons) II-1/3-1 Ships shall be designed, constructed and maintined in compliance with electrical requirements of a class society recognized by the administration. Multiple alarms in the engine control room were disengaged so alarms would not sound. See Form B.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2015
Lifesaving › Rescue Boat › Propulsion Engine
Issued 10 December 2015 Resolved
74SOLAS(2014cons)III/20.2 Before the ship leaves port and at all times during the voyage, all life-saving-appliances shall be in working order and ready for immediate use. Rescue boat engine stalls when in idle.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 December 2015
Documentation › Logs/Records › Oil Record Book
Issued 10 December 2015 Resolved
73 MARPOL Annex 1, Reg 17.2.3 & 17.4 - There are no entries between Dec. 2nd and 9th to account for the addition of approximately 18.5 cubic meters in the sludge tank and 8.1 cubic meters in the dirty oil tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2015
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 December 2015 Resolved
74SOLAS(2014 Cons. Ed.)I/11(a) - The engine room had large amounts of debris including oil soaked wood and lines along with several buckets located in the engine room and inside containment areas of fuel tanks. The containment areas and bilges had excessive amounts of HFO, and diesel fuel, creating a serious fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2016
Resolution: Vessel hired contractor to clean out engine room bilges and clean out engine room.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 December 2015 Resolved
74SOLAS(2014 Cons. Ed.) II-2/15.2.4.1 - Fire control plan does not match vessel configuration, including vessel galley doors, fire extinguishers, and accommodation spaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2015
Documentation › Logs/Records › Oil Record Book
Issued 10 December 2015 Resolved
MARPOL Annex IV Reg. 14.6 - Fuel changeover operations were not recorded in the oil record book for several months.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2015
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 10 December 2015 Resolved
74SOLAS(2004 Cons. Ed.)II-1/26.1 - Unauthorized modifications were made to main engine such that air blower and flexible ducting was temporarily affixed to air intake on turbo charger on main engine to provide additional air.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2015
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 December 2015 Resolved
33CFR159.7(a)(2) - The Marine Sanitation Device appears to be leaking with noticeable odor and the alarm is showing on alarm panel in ECR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2015
Resolution: Received class report.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 December 2015 Resolved
74SOLAS(97 Cons. Ed.)II-2/46.1 - Stairways which penetrate only a single deck shall be protected at least at one level by self-closing doors. Multiple stairwell doors were held open by wooden blocks.
Action required: 705 - Other - as specified
Resolved 10 December 2015
Resolution: Corrected on the spot to the satisfaction of attending PSC Team.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 December 2015 Resolved
74SOLAS(97 Cons. Ed.)II-2/47.1 - Galley doors have had handles removed leaving holes so that the doors no longer meet the level of fire protection required for the space.
Action required: 705 - Other - as specified
Resolved 10 December 2015
Resolution: Corrected on the spot to the satisfaction of attending PSC Team.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 July 2015 Resolved
0650 - Not less than half the total number of lifebuoys shall be provided with self-igniting lights. Vessel has 8 lifebuoys total but only 2 are equipped with self-igniting lights. 74 SOLAS (97) III/7.1.3 - 16ac
Action required: 705 - Other - as specified
Due 7 August 2015
Resolved 11 August 2015
Resolution: Received class report attesting to the proper condition.
Fire Fighting › Fire Main › Material
Issued 24 July 2015 Resolved
0720 - Fire-fighting systems shall be in good working order and readily available for immediate use. Starboard side fire main piping leading to the international shore connection has a temporary patch and is leaking significantly. 74 SOLAS (14) II-2/14.2.1.2 - 16ac
Action required: 705 - Other - as specified
Due 7 August 2015
Resolved 8 August 2015
Resolution: Received class report attesting to the proper operation. Repaired by renewing damaged pipe. Pressure tested, and found in order by attending class surveyor.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 24 July 2015 Resolved
1500 - Cargo ships when engaged in international voyages shall be cited with a voyage data recorder. Vessel's VDR has multiple error messages. 74 SOLAS (14) V/20.2 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2015
Resolution: Class report was submitted, clearing deficiency.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 July 2015 Resolved
1299 - Efficient guard rails of bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. Guard rail by cargo hold 7 starboard side is wasted and fractured. ICLL 66/88 Annex I Reg. 25.2 - 16ac
Action required: 705 - Other - as specified
Due 7 August 2015
Resolved 8 August 2015
Resolution: Received class report attesting to the proper condition.
Documentation › Logs/Records › Oil Record Book
Issued 24 July 2015 Resolved
1710 - The Oil Record Book Part I shall be completed on each occasion on a tank-to-tank basis whenever machinery space operations take place. Tank-to-tank transfers are not being recorded in the Oil Record Book. 73/78 MARPOL Annex I Reg. 17.2 - 10c
Action required: 705 - Other - as specified
Resolved 24 July 2015
Resolution: The Chief engineer was informed and will start logging all transfers.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 19 January 2012 Resolved
0725- FIXED FIRE EXTUINGUISHING INSTALLATION CLASS A FIRE DOOR LEADING TO AIR CONDITIONER/ LAUNDRY ROOM DID NOT CLOSE UNASSISTED AND WAS UNABLE TO PROVIDE RESISTANCE TO FIREAS WELL AS TO THE PASSAGE OF SMOKE AND FLAME EQUIVALENT TO THAT OF THE BULKHEAD. SOLAS 2004 CH. II-2REG. 9/4.2.1
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 February 2012
Resolution: Vessel provided subjective evidence to prove they repaired the fire door leading to the air conditioner/laundry room.
Engineering › Steering Gear System › Piping
Issued 24 November 2010 Resolved
Piping that connects storage tank to steering gear system is not there.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 April 2011
Resolution: Received class report stating missing pipe between steering gear and reserve hydraulic fluid tank was connected.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 29 April 2008 Resolved
30APR2008-Secondary means to start the emergency generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2008
Resolution: Vessel provided a class report attesting to the proper operation of the secondary means to start the emergency generator.
Engineering › Bilge Water Management System › Valve
Issued 27 April 2007 Resolved
The vessel has a second direct overboard discharge valve with a pump and piping system that allows direct discharge from the bilge without first passing through an approved oil filtering equipment. The vessel is required to have the certificate issuing authority verify that this system of pipes and pump can not pump oil or oily mixtures from the bilge directly overboard.
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 18 July 2007
Resolution: Received satisfactory Classification Society report attesting to repairs made.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 23 January 2006 Resolved
Vessel had crew member staying in the hospital space. The vessel is required to have a hospital space as per SOLAS unless they remove one crew member.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 April 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 23 January 2006 Resolved
Several lights found through out the ship had no covers.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 April 2006
Lifesaving › Lifeboat
Issued 17 February 2004 Resolved
07 Food rations on board free fall lififeboat were damaged. 74 SOLAS III/ 13.1.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2004
Electrical › Lighting (service)
Issued 25 June 2003 Resolved
Administration to survey and attest to the certification of the safe type light fixture in the paint locker prior to 25 July 2003. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 25 July 2003
Resolved 8 August 2003
Documentation › Certificates/Documents
Issued 6 June 2003 Resolved
New COFR being issued due to name change. Vessel granted substantial compliance by NPFC. Certificate to be obtained prior to next US port call. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Action required: 15 - Rectify deficiencies by next port
Resolved 8 August 2003
Resolution: Received copy of the new COFR via fax from the vessel agent and checked the status at NPFC.
Documentation
Issued 8 March 2000 Resolved
Class represenative to submit a report on the condition of steering gear prior to departing port to the satisfaction of the Coast Guard Inspector.
Condition: Unknown
Due 8 March 2000
Resolved 14 March 2000
Fire Fighting
Issued 8 March 2000 Resolved
Provide a IMO approved symbology fire plan with class approval stamp, to the satisfaction of attending class surveyor and USCG. _x001C_ SOLAS 74(amended) II-2/20-1
Condition: Unknown
Due 8 April 2000
Resolved 14 March 2000
Fire Fighting
Issued 8 March 2000 Resolved
Fabricate or modify the international shore connection (flange slots) to the satisfaction of the attending Class surveyor or C.G. Marine Inspector._x001C_SOLAS 74 (amended) II-2/4.7.2
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Construction/Loadline
Issued 8 March 2000 Resolved
Provide class report for the hull underwater survey conducted after grounding incident of 08MAR00 to the satisfaction of the Coast Guard_x001C_ Marine Inspector. Report to be submitted to MSO Mobile prior to departure.
Condition: Unknown
Due 8 March 2000
Resolved 14 March 2000
Navigation
Issued 17 September 1999 Resolved
ECHO DEPTH SOUNDER PAPER RECORDER NOT RECORDING IAW 33CFR 164.35(i)_x001C_ REPAIR/PROVIDE TECHNICAL REPORT AS TO PROPER OPERATION OF ECHO DEPTH SOUNDING DEEVICE TO LOCAL OCMI
Condition: Unknown
Due 13 November 1999
Resolved 13 November 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.