MAURY USCG vessel records Sign in
← All vessels

GSF CELTIC SEA

GSF CELTIC SEA is a 1981 mobile offshore drilling unit. The Coast Guard has recorded 33 inspections since 1998, most recently in July 2009, along with 66 deficiencies.

Records from 1998 to 2009. Most recent: inspection, 7 July 2009.

Built
1981
Last inspected
7 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8758067 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
449011
Flag
VANUATU
—
Maury page id
psix-449011

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (1998–2009)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it28440 - Regulatory (Subpart C or D), Gross Ton
8532 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 33

7 July 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3526593
18 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132700
10 January 2008 Administrative Inspection · COC-MODU Renew
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3127941
4 May 2007 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2922177
30 August 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2820742
16 February 2006 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2588686
6 February 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2592550
11 February 2005 COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2290743
7 December 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2255126
26 November 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2254877
21 February 2004 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2010479
7 August 2003 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1867238
5 February 2003 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1742232
5 October 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1694775
27 September 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1694436
4 June 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1626174
20 April 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607033
12 February 2002 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1489803
23 September 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073596
2 September 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1491842
26 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073178
23 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068644
14 April 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061589
23 February 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450577
15 March 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816347
22 February 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442961
23 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810102
12 April 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123257
26 February 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472022
7 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808405
11 May 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127759
21 February 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1431917
20 February 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778389

Deficiency record · 66

Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2006 Resolved
Properly terminate dead end wires throughout, I.E. #1 & #2 TUR rooms, S2 Thruster, Stbd upper thruste
Due 16 March 2006
Resolved 6 March 2007
Resolution: Dead end wires removed.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 16 February 2006 Resolved
Rescue boat will not operate / start. Prove reliable operation of rescue boat. Until this is accomplished designate one of the life boats as the rescue boat. This shall be to the satisfaction of the attending USCG Marine Inspector or flag state representative.
Due 23 March 2006
Resolved 25 February 2006
Resolution: Lfie boat #1 designated as the rescue boat.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 February 2006 Resolved
. Hard pipe fuel fill line , 5th deck where aviation fuel tote tanks to go aviation fuel skid. Presently have "approved" rubber fuel hose, approximately 60 foot run. This shall be to the satisfaction of attend USCG Marine Inspector or Flag state representative
Due 23 February 2006
Resolved 25 February 2006
Resolution: Hard piped.
Lifesaving › Rescue Boat › Construction
Issued 11 February 2005 Resolved
Rescue boat was not in ready condition, needed overall maintenance. Either have it serviced or remove it froim the rig and designate one of the lifeboats as the rescue boat.
Due 10 March 2005
Resolved 7 March 2006
Resolution: see narative for activitiy # 2290743
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 7 August 2003 Resolved
Re-hang ionization fire detector inside paint locker.
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 9 August 2003
Resolution: Corrected per email report & digital photo of 08AUG03
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 August 2003 Resolved
Re-connect actuators for emergency generator enclosure louvers & renew louver seals where missing.
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 1 September 2003
Resolution: 08AUG03 - Received rpt from Master/OIM [name withheld] confirmeing reinstallation of egen louver actuators. 01SEP03 - Received report from Master/OIM [name withheld] confirming that louver seals were renewed.
Construction/Loadline › Structures
Issued 7 August 2003 Resolved
Replace two missing dogs on Mud pump room door. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 8 August 2003
Construction/Loadline › Structures
Issued 7 August 2003 Resolved
Replace missing dog on outer door for Mud pit room air lock. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 8 August 2003
Construction/Loadline › Penetrations
Issued 7 August 2003 Resolved
Close open penetration through inner bulkhead of mud pit room air lock.
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 9 August 2003
Electrical › Lighting (emergency)
Issued 7 August 2003 Resolved
Replace broken E-light cover in haz locations IWO mud pit and shaker space exhaust vents.
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 9 August 2003
Construction/Loadline › Hull
Issued 5 February 2003 Resolved
Complete visual internal exam or provide ultrasonic testing of all rig system pressure vessels. Include U1-A sheets with gaugings report.
Due 4 March 2003
Resolved 10 February 2003
Resolution: ABS visual exam report submitted.
Lifesaving › Launching Appliances
Issued 5 February 2003 Resolved
Renew rescue boat davit cable and weight test after completion. LEGACY COMPONENT DESC: Davit
Due 4 March 2003
Resolved 3 March 2003
Accommodation/Occupational Safety › Ventilation
Issued 5 February 2003 Resolved
Provide proper operation of loss of ventilation alarm in pit room. LEGACY COMPONENT DESC: Pit Room Ventilation
Due 4 March 2003
Resolved 3 March 2003
Construction/Loadline › Structures
Issued 12 February 2002 Resolved
Properly adjust watertight door leading to compressor room and ensure that indicator switch is operable (to indicate open/closed position). LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Fire Fighting › Structural - A Class Divisions
Issued 12 February 2002 Resolved
Provide door closer for battery room & repair intake vent dog LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Accommodation/Occupational Safety › Occupational Safety
Issued 12 February 2002 Resolved
Rapair starboard forward corner netting IWO helicopter deck. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Construction/Loadline › Structures
Issued 12 February 2002 Resolved
Renew starboard aft passageway exterior and frame located starboard side deck #4. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Accommodation/Occupational Safety › Occupational Safety
Issued 12 February 2002 Resolved
Remove pigtail.s from junction boxes in overhead located in #1 & #3 winch houses. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Engineering › Diesel Engine (propulsion-electric)
Issued 12 February 2002 Resolved
Provide & install exhaust blankets for all MDEs exhaust piping leading to turbochargers. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 28 March 2002
Resolution: Outstanding completed as per facsimile transmittal from OIM dated 27MAR02.
Engineering › Compressed Air System (control)
Issued 12 February 2002 Resolved
Provide documentation for all pressure vessel relief valves to demonstrate they have been properly tested twice in 5 years, with no interval more than 3 years. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Unknown
Due 29 March 2002
Resolved 28 March 2002
Resolution: Cleared on 27MAR02 by OIM fax dated 27MAR02
Engineering › Diesel Engine (propulsion-electric)
Issued 12 February 2002 Resolved
Affect permanent repair to MDE generator bearing lube oil supply line (P1, P2, S2) LEGACY COMPONENT DESC: Bearing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 4 June 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 12 February 2002 Resolved
Repair leaking F/O valves on F/O settling tank supplying MDEs P1-P2. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Electrical › Electric Supply System (service)
Issued 12 February 2002 Resolved
Provide permanent covers for all openings in distribution panels throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Fire Fighting › Structural - A Class Divisions
Issued 12 February 2002 Resolved
Starboard main dining room door in stairway missing magnetic bracket. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Personnel › Certificates/Documents/Licenses
Issued 12 February 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Engineering › Diesel Engine (propulsion-electric)
Issued 12 February 2002 Resolved
Repair or replace damaged/missing components on starboard MDE primer pump motor controller.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Engineering › Generator (propulsion/auxiliary-electric)
Issued 12 February 2002 Resolved
Demonstrate proper operation of "load/unload" automation on S3-S4 generators. LEGACY COMPONENT DESC: Remote Control Circutry
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Electrical › Electric Supply System (service)
Issued 12 February 2002 Resolved
Install overhead panels in 5th deck electrical locker and properly run all cables in overhead. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 28 March 2002
Resolution: as per OIM Fax dated 27MAR02. Item completed.
Electrical › Lighting (service)
Issued 12 February 2002 Resolved
Demonstrate proper operation of port side construction operation light.
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 28 March 2002
Resolution: Completed by fax from OIM dated 27MAR02.
Accommodation/Occupational Safety › Occupational Safety
Issued 12 February 2002 Resolved
Remove or properly identify/tag alldead-end cables throughout vessel. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Fire Fighting › Ventilation Systems
Issued 12 February 2002 Resolved
Prove proper operation of paint locker vent (automatic CO2) and properly stow all paints/thinners (remove from vicinity of CO2 discharge control piping).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Operations/Management › FireFighting
Issued 12 February 2002 Resolved
Validate fire control plan. Numerous vent shutdowns and extinguisher locations are misrepresented or missing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 4 June 2002
Accommodation/Occupational Safety › Ventilation
Issued 12 February 2002 Resolved
Provide adequate exterior ventilation for chlorine storage (vicinity of electrician's cabin.)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Electrical › Lighting (emergency)
Issued 12 February 2002 Resolved
Replace cracked explosion proof red light fixture in shale shaker room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: PEr OIM ltr of 06MAR02.
Electrical › Electric Supply System (service)
Issued 12 February 2002 Resolved
Remove or properly route wiring for mud logging on drill floor. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Accommodation/Occupational Safety › Occupational Safety
Issued 12 February 2002 Resolved
Provide landing rail for forward starboard 4th deck exterior ladder (stairs). LEGACY COMPONENT DESC: Storm Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Accommodation/Occupational Safety › Occupational Safety
Issued 12 February 2002 Resolved
Provide safety chain for aft starboard leg escape ladder at main deck. LEGACY COMPONENT DESC: Lifeline
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 6 March 2002
Resolution: Per OIM ltr of 06MAR02
Lifesaving › Embarkation Appliances/Stations
Issued 12 February 2002 Resolved
Provide adedquate egress routes/access to lifeboats (#3 & #4 blocked by Oceaneering boxes) LEGACY COMPONENT DESC: Accessability
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 28 March 2002
Resolution: Completed on 27MAR02 by OIM fax.
Lifesaving › Inflatable Liferafts
Issued 12 February 2002 Resolved
Liferafts rated for stowage at maximum height of 25 meters were stowed at a height approximately 28 meters above the water.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 27 March 2002
Resolution: Cleared, recieved fax letter from ABS dated 27MAR02
Documentation
Issued 23 February 2001 Resolved
Complete ABS Class Surveyor's deficiency list issued on 03Feb01. Submit final ABS report to [name withheld].
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Lifesaving
Issued 23 February 2001 Resolved
Conduct 1.1 operational load test on rescue boat release gear.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Electrical
Issued 22 February 2000 Resolved
ENSURE PROPER OPERATION OF LOCAL CONTROL TO STARBOARD FIRE PUMP. VERIFY PORT FIRE PUMP IS IN GOOD OPERATION AS WELL.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Fire Fighting
Issued 22 February 2000 Resolved
REPOSITION FIRE STATION HOSE RACK "CO2" SO HOSE DOES NOT KINK.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Fire Fighting
Issued 22 February 2000 Resolved
CROP AND RENEW WASTED FIREMAIN PIPING AT HELI-DECK HOSE STATION.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Electrical
Issued 22 February 2000 Resolved
PROVIDE PROPER BULKHEAD PENETRATIONS WITH APPROVED SEALANT AND HARDPIPE HOSE CONFIGURATION IN ACTIVE MUD PITS.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Lifesaving
Issued 22 February 2000 Resolved
CROP AND RENEW WASTED AND HOLED HANDRAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Electrical
Issued 22 February 2000 Resolved
PROPERLY SECURE ELECTRICAL WIRING IN SUPPORT TRAYS OR PROVIDE METAL BANDINGAND REMOVE PLASTIC TIES ON DRILL FLOOR OVERHEAD AND VICINITY.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Fire Fighting
Issued 26 February 1999 Resolved
REPLACE ALL FIRE HOSES AND NOZZLES WITH APPROVED HOSES AND NOZZLES.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 26 February 1999 Resolved
REPLACE ALL STAINLESS STEEL FIRE EXTINGUISHERS WITH APPROVED PORTABLE FIRE EXTINGUISHERS IN ACCOMODATION SPACES.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Unknown
Issued 26 February 1999 Resolved
REMOVE ALL LIFTING PAD EYES AND EFFECT PERMANENT REPAIRS TO THE HELICOPTER DECK TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Unknown
Issued 26 February 1999 Resolved
CONDUCT AND PROPERLY LOG OPERATIONAL TEST OF TOTAL RIG AND VENTILATION SHUTDOWNS.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Unknown
Issued 26 February 1999 Resolved
PROPERLY BLANK OFF, LABEL AND TAG OUT ALL ELECTRICAL DISTRIBUTION PANELS ASNECESSARY. REPLACE ALL FUSE TYPE DISTRIBUTION PANELS WITH BREAKER TYPE PANELS.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 26 February 1999 Resolved
REPLACE ALL LIFEJACKETS WITH APPROVED TYPE I LIFEJACKETS.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Unknown
Issued 26 February 1999 Resolved
CONDUCT 1.1 OPERATIONAL TEST OF ALL LIFEBOATS RELEASE GEARS OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE LOCAL OCMI.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 26 February 1999 Resolved
REPLACE CRACKED AND INOPERATIVE FIRE PUMP GAUGES.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Unknown
Issued 26 February 1999 Resolved
ENSURE ALL POWER VENTILATION SYSTEMS SHUT DOWN FAN MOTORS UPON ACTIVATION OF EMERGENCY SHUT DOWN.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 26 February 1999 Resolved
RECHARGE PAINT LOCKER FIXED CO2 THAT WAS ACCIDENTALLY DISCHARGED.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Unknown
Issued 26 February 1999 Resolved
SUBMIT AN EMERGENCY EVACUATION PLAN FOR APPROVAL BY [name withheld].
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Unknown
Issued 26 February 1999 Resolved
PERFORM ANNUAL CERTIFICATION OF ELEVATORS THROUGHOUT RIG. SUBMIT COPY OF TECHNICIANS REPORT TO [name withheld].
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 26 February 1999 Resolved
REWORK ALL EXTERIOR FIRE DAMPERS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 26 February 1999 Resolved
PROVIDE "CI" TYPE PORTABLE FIRE EXTINGUISHER FOR INDUSTRIAL TRUCK.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Unknown
Issued 26 February 1999 Resolved
CONDUCT OPERATIONAL TEST OF LOW LUBE OIL AND OVERSPEED SHUTDOWN ON EMERGENCY DIESEL GENERATOR.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 26 February 1999 Resolved
SUBMIT FOR APPROVAL AN UPDATED AND REVISED FIREFIGHTING, LIFESAVING AND HAZARDOUS LOCATION PLAN IN ACCORDANCE WITH IMO STANDARDS TO [name withheld].
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 26 February 1999 Resolved
PROPERLY STOW ALL FLAMMABLE LIQUIDS IN PAINT LOCKER.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Unknown
Issued 26 February 1999 Resolved
REMOVE OIL AND CLEAN MACHINERY SPACE BILGES.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Engineering
Issued 26 February 1999 Resolved
REPLACE ALL DOWELL UNIT FLEXIBLE FUEL OIL LINES THAT EXCEED 30" WITH HARD PIPING.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.