← All vessels
EVER UTILE
EVER UTILE is a 2000 freight ship. The Coast Guard has recorded 18 inspections since 2000, most recently in November 2021, along with 12 deficiencies and 2 operational controls.
Records from 2000 to 2021. Most recent: inspection, 23 November 2021.
- Built
- 2000
- Last inspected
- 23 November 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9188154 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FZA9
4491
Flag
PANAMA
—
Maury page id
psix-4491
Inspections, by type
…with no type recorded3
Years with a record
11 calendar years (2000–2021)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it63216 - Dead Weight, Metric Ton
87544 - Displacement, Metric Ton
69246 - Convention (Subpart B), Gross Ton
30235 - Convention (Subpart B), Net Ton
87544 - Displacement, Metric Ton
69246 - Convention (Subpart B), Gross Ton
30235 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
23 November 2021
PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7356372
16 December 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6059125
1 November 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6033576
23 September 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6001923
3 November 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5752688
26 October 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5751100
22 September 2015
Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5726553
6 January 2012
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4221679
21 July 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4083395
16 January 2009
PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3392237
8 May 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3202082
29 January 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3138527
23 December 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3119918
21 November 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3102515
25 April 2006
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2633035
21 March 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2607045
10 June 2005
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2386070
21 April 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 277128
Deficiency record · 12
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 16 December 2016
Resolved
Number 11 cylinder was found in an abnormal state, causing the main engine to be required to be set to 70 RPM.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 September 2015
Resolved
Solas (2001) II-2 Reg 15.2.11 #3 and #4 generator have active fuel leaks on to heated surfaces and multiple other sources of ignition.
Oil fuel lines shall be screened or otherwise suitably protected to avoid, as far as practicable, oil spray or oil leakages onto hot surfaces, into machinery air intakes, or other sources of ignition.
Lifesaving › Lifeboat › Hull
Issued 22 September 2015
Resolved
Solas (2009) III Reg 4.2.1 - LSA 4.4.1.1 Previous patch has deteriated off the hull.
Before giving approval to life-saving appliances and arrangements, the administration shall ensure that such life-saving appliances and arrangements are tested, to conform that they comply with the requirements of this chapter and the code, in accordance with the recommendations of the organization all lifeboats
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 September 2015
Resolved
Solas (2001) II-1 Reg 45.1.3 Exposed electrical wiring on #4 generator and lighting fixtures above fuel purifiers.
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner.
Deck/Cargo › Ballast › Piping
Issued 22 September 2015
Resolved
Solas (2014)I Reg 11.B Hole in fore peak tank overflow piping.
After any survey of the ship under regulations 7,8,9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 22 September 2015
Resolved
Solas (2014) I Reg 11.B Cascade tank has severe wastage around observation window.
After any survey of the ship under regulations 7,8,9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration.
Engineering › Freshwater System (air cooling) › Piping
Issued 22 September 2015
Resolved
Solas (2014) I Reg 11.B Multiple sections of piping missing on A/C compressor.
After any survey of the ship under regulations 7,8,9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 21 July 2011
Resolved
2nd engineer does not have a valid flag state endorsement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 July 2011
Resolved
self closing fire door has a hold back hook
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 21 July 2011
Resolved
both smoke signals on the bridge wings are corroded.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 23 December 2007
Resolved
Vessel did not have a copy of the Federal/U.S. Non-Tank Vessel Respone Plan onbaoard at the time of inpsection. Correct to the satisfaciton of the Coast Guard.
Construction/Loadline › Structures › Door
Issued 23 December 2007
Resolved
One of the two doors used for egress from the port generator room is inoperable due to faulty door hardware. Crew was unable to open door for escape, creating a safety hazard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.