MAURY USCG vessel records
← All vessels

SEATRADE ISLANDER

Built
1965
Last inspected
17 November 1992
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 17 November 1992
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (1988–1992)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
PANAMA
Tonnage
1312 - Regulatory (Subpart C or D), Gross Ton 1312 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-44945
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

17 November 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826814
1 October 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936984
25 April 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233283
16 December 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344209

Deficiency record · 9

Documentation
Issued 16 December 1988 Resolved
PROVIDE A VALID FMC CERT AS REQ BY 46 CFR 542 & PRIOR TO CARRIAGE OF CARGO.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 16 December 1988 Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLASS WITH A DROP TEST OF EACH ANCHOR.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 16 December 1988 Resolved
PROVIDE SUITABLE PAINTER FOR BUOYANT APPARTUS.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 16 December 1988 Resolved
RAISE AFTER MASTHEAD LIGHT AT LEAST 1' AND PROVIDE SUITABLE GUIDEWIRES FOR BOTH FWD & AFT MASTHEAD LIGHTS.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 16 December 1988 Resolved
PROVIDE A SUITABLE FLOAT-FREE WEAK LINK FOR 8 PERSON FOR B/A AS PER 46 CFR 33.20-25.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 16 December 1988 Resolved
PROVIDE PROPER NAVIGATIONAL CHARTS AND PUBS AS REQ BY 33 CFR 164.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 16 December 1988 Resolved
PROVE THE RED LIGHT FOR OIL TRANSFER AT NIGHT IS AN EXPLOSION PROOF FIXTUREOR REPLACE.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 16 December 1988 Resolved
PROVE PROPER OPERATION OF HEATING BOILER STACK CONTROL FLAME CUTOUT OR REPLACE.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 16 December 1988 Resolved
PROVIDE EVIDENCE POTABLE WATER IS SUITABLE FOR DRINKING.
Condition: Unknown
Due 10 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past