Records from 1996 to 2025. Most recent: inspection, 19 November 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
19 November 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8250008
5 December 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8013588
5 October 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7799803
20 September 2022
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7531767
22 September 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7311511
24 September 2020
DAPI Audit · Annual Inspection · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7069926
26 September 2019
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6814722
19 September 2018
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6520113
19 September 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6545024
15 September 2017
COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6267113
15 September 2016
Hull Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995099
20 October 2015
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5746547
27 August 2015
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5227535
17 October 2014
Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5009954
8 February 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4240643
27 September 2011
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4156546
8 September 2010
Administrative Inspection · Drydock Exam · Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3845422
22 October 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3352315
18 October 2007
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3082152
18 October 2005
Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2474463
24 November 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2249143
17 August 2004
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2168681
10 November 2003
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1943357
11 September 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1873843
18 October 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1693368
15 October 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1074766
16 August 2001
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448331
22 September 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424991
25 July 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1051494
18 August 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391098
19 November 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1442800
9 February 1998
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1109806
16 September 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1388374
19 September 1996
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424295
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 September 2019
Resolved
USCG Type A1, A2, B1, or B2 flexible hose may be accepted in accordance with 33 CFR part 183, subpart J.
Replace unapproved flex hose in accordance with SAE J1527.
46 CFR 182.720 (e)(3)(v)(c)
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 10 October 2019
Resolution: Owner/Operator replaced flex hose IAW SAE J1527.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2019
Resolved
Ring life buoy must be fitted with a lifeline.
Replace unapproved lifeline with 5/16" UV protected line.
46 CFR 180.70 (c)
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 10 October 2019
Resolution: Owner / Operator replaced ring buoy lifeline.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2019
Resolved
A positive shutoff valve is installed at the hull penetration for submersible electric bilge pump. O/O needs to install shutoff valve at hull penetration IAW 46 CFR 182.520(e)(6).
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 10 October 2019
Resolution: Owner/Operator installed valve at the hull penetration for submersible electric bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 September 2018
Resolved
The containers in which they are stowed shall be marked "Life Preservers" and with the number contained therein, in at least 1-inch high letters and figures.
46CFR185.30-10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 September 2018
Resolved 19 September 2018
Resolution: Owner labeled each life jacket storage container with the number and size of life jackets stored in each.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 September 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2018
Resolution: Called O/O to resolve issue. All designated masters in company have conducted drills w/ attending marine inspectors to comply with local master only policy.
Construction/Loadline › Structures › Superstructure
Issued 27 September 2011
Resolved
Repair cracked life jacket shelf and railing throughout vessel IAW 46CFR176.802.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2011
Resolution: Repaired life jacket shelf and railing throughout vessel IAW 46CFR176.802.
Deck/Cargo › Cargo Stowage › General
Issued 27 September 2011
Resolved
Repair forward step delaminated areas in the way of the bow IAW 46CFR176.802.
Action required: 705 - Other - as specified
Due 27 October 2011
Resolved 3 November 2011
Resolution: Repaired forward step in way of bow IAW 46CFR176.802
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 October 2005
Resolved
Install missing safety chain on forward hand rail.
Due 18 November 2005
Resolved 15 December 2005
Resolution: Digital pictures submitted. Printed and included with case. E-copies transferred to electronic file.
Construction/Loadline › Structures › Deck Plating
Issued 18 October 2005
Resolved
Make structural repairs to the forward stairs and aft decking where fiberglass has separated and deck is deteriorating.
Due 18 November 2005
Resolved 15 December 2005
Resolution: Digital pictures submitted. Printed and included with case. E-copies transferred to electronic file.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 October 2005
Resolved
Provide proof of valid mariners license for crew member w/ expired license. (Swiatek)
Due 18 November 2005
Resolved 19 October 2005
Resolution: Employee was terminated.
Lifesaving
Issued 16 August 2001
Resolved
Replace one adult PFD, vessel's carrying capacity is reduced to 16 until the PFD is replaced.
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Accommodation/Occupational Safety
Issued 18 August 1999
Resolved
REPLACE IN KIND BROKEN BOTTOM STEP ON DIVE LADDER.
Condition: Unknown
Due 18 August 1999
Resolved 18 August 1999
Fire Fighting
Issued 18 August 1999
Resolved
REPLACE IN KIND BROKEN PORTABLE FIRE EXTINGUISHER BRACKET.
Condition: Unknown
Due 18 August 1999
Resolved 18 August 1999
Navigation
Issued 18 August 1999
Resolved
PROPERLY INSTALL BOW NAVIGATION LIGHT WIRING TO RUN INTERNALLY. _x001C_
Condition: Unknown
Due 18 August 1999
Resolved 18 August 1999
Fire Fighting
Issued 19 November 1998
Resolved
PROVIDE THREE 2 1/2 GALLON BUCKETS LABLED "FIRE BUCKET".
Condition: Unknown
Due 20 November 1999
Resolved 17 March 1999
Engineering
Issued 19 November 1998
Resolved
REPLACE EMERGENCY CUT-OFF VALVE.
Condition: Unknown
Due 20 November 1999
Resolved 17 March 1999
Electrical
Issued 19 November 1998
Resolved
BUNDLE AND SUPPORT WIRING UNDER CONTROL PANEL.
Condition: Unknown
Due 20 November 1998
Resolved 17 March 1999