Records from 1984 to 2006. Most recent: inspection, 18 October 2006.
Inspection history · 374
18 October 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2803098
16 October 2006
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2801341
28 June 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2694525
28 February 2006
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2593142
30 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2575759
26 January 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2576921
7 December 2005
Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2547760
18 November 2005
Re-Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2537178
19 October 2005
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2517421
29 August 2005
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2478259
24 August 2005
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2473145
5 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2452525
21 July 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2434303
12 July 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2423906
10 July 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2421519
6 July 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2416931
23 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2400644
25 May 2005
COI Inspection · Security Plan Review - VSP
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2367927
19 May 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2479321
18 May 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2361798
9 May 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2626497
20 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2338768
30 March 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2633871
28 March 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2633842
27 March 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2320768
18 March 2005
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2313942
18 March 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2318785
16 March 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2633724
15 March 2005
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2310695
3 March 2005
Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2302679
14 February 2005
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2293438
2 February 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2285506
10 January 2005
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2272132
28 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2299375
27 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2273757
22 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2263742
14 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2259098
13 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2258424
10 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2288185
8 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2255708
3 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2252813
1 December 2004
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2251241
1 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2251537
3 November 2004
Administrative Inspection
Administrative · Maritime Safety & Security Team New York (91106) · Activity 2233818
3 November 2004
Administrative Inspection
Administrative · Maritime Safety & Security Team New York (91106) · Activity 2233862
3 November 2004
Administrative Inspection
Administrative · Maritime Safety & Security Team New York (91106) · Activity 2233870
3 November 2004
Administrative Inspection
Administrative · Maritime Safety & Security Team New York (91106) · Activity 2233891
29 October 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2252017
29 September 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2209214
22 September 2004
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2201929
15 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2200078
2 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2184788
2 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2185190
1 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2183954
30 August 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2181532
27 August 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2179122
27 August 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2179149
23 August 2004
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2175166
6 August 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2230806
5 August 2004
MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2157212
2 August 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2153392
22 June 2004
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2107100
22 June 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2118855
1 June 2004
COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2084626
10 May 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2064299
27 April 2004
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2387299
26 April 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2134633
26 April 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2299345
15 April 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2044674
2 April 2004
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2036277
4 March 2004
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2017419
28 January 2004
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2388262
27 January 2004
In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2002887
23 January 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1991314
13 January 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1983060
15 December 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1965761
12 December 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1963079
4 December 2003
MARPOL Annex V Examination · Quarterly Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1958776
19 November 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1951028
18 November 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1951043
14 November 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2292418
4 November 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1942574
3 November 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1941407
22 October 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1933756
17 October 2003
MARPOL Annex V Examination · Quarterly Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1930634
22 September 2003
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1910223
20 August 2003
In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1886616
14 July 2003
Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1845672
6 June 2003
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1815433
3 June 2003
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1808936
16 May 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1794829
23 April 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1780031
8 April 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1770148
7 March 2003
Drydock Extension · Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1753968
24 December 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1722687
23 December 2002
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1722448
5 December 2002
Deficiency Check · Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1714890
4 December 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1715419
27 November 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1711757
22 November 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1709252
18 November 2002
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1707189
10 October 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1694376
9 September 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1673212
27 August 2002
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1664747
7 August 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1660351
25 July 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1652084
7 July 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1643240
18 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1636003
17 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1632540
3 June 2002
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1625325
5 May 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1613312
22 March 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495869
20 March 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1597645
15 March 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495829
6 March 2002
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1491507
19 February 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1487871
3 January 2002
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1475204
3 January 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1475688
26 December 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1474551
5 December 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1076980
2 November 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 772213
22 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 134126
4 October 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074743
20 September 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074243
26 August 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 75189
8 August 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1070806
17 July 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 150141
20 June 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1432537
18 June 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1362294
7 June 2001
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1471426
13 March 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1060110
28 February 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1666471
22 January 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1373160
15 August 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 821371
20 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 163412
12 July 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 820719
27 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 66259
26 June 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051270
19 June 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051128
1 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 66589
1 June 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1050695
29 May 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 23034
27 May 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 123259
15 May 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 61616
8 April 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1048933
7 April 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1050109
30 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 72770
30 March 2000
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 816721
16 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 133728
9 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 64106
28 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 72038
22 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 37577
17 February 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 815661
4 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1378941
28 January 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 813973
27 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 11395
25 January 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1045556
19 January 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 814031
20 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 142771
15 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 85800
15 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 146357
14 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 47604
9 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 10286
30 November 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 810905
30 November 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 812706
12 November 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 84534
10 November 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 805785
25 October 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 793137
20 October 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1125947
18 October 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788410
14 October 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 15538
7 October 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887269
4 October 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 69467
4 October 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1042239
30 September 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 149899
30 September 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1347111
22 September 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 133864
22 September 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033128
23 August 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779537
11 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384224
6 August 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 776056
26 July 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1107256
16 July 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1464867
15 July 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 172259
22 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 86804
16 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 138862
9 June 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1447966
14 April 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788506
10 February 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 41730
1 February 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1124908
31 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 10804
19 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 21456
19 January 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337122
14 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 110353
14 January 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1464815
9 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 141489
9 January 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1411784
20 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 59394
14 December 1998
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1471849
9 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 174893
10 November 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 89016
4 November 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803171
3 November 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803619
28 October 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803788
25 October 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 7454
23 October 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 113910
8 October 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 50581
5 October 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 92814
11 August 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 179539
27 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 132996
23 July 1998
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129309
20 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 30304
18 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 7040
12 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 142025
12 July 1998
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 794359
2 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 12678
21 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 95956
5 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 36883
1 May 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1124167
30 April 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430543
26 April 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 133341
25 April 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 113195
16 April 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788705
6 April 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1375330
31 March 1998
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788355
3 March 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1117508
15 January 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 774034
29 December 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 782681
22 December 1997
Damage Survey · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1437341
20 December 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 63696
19 December 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 784544
18 December 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 786414
9 December 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1112846
9 December 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1114576
18 November 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1108761
10 November 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 91485
29 October 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1438650
27 October 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1119433
29 September 1997
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1120824
11 September 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 786646
11 September 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1121836
4 September 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 18621
20 August 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1118655
6 August 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1400641
14 July 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1407929
26 June 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1466475
17 April 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1103548
28 February 1997
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1110202
18 February 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1107167
3 February 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1103889
27 January 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 158735
24 January 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1465288
7 January 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1098000
5 January 1997
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1463284
20 December 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1095826
17 December 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 5570
17 December 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1425833
19 November 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1185602
5 November 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168923
2 October 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840154
13 September 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955336
6 September 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1414691
23 August 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1086689
5 August 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1087278
27 June 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932914
11 June 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085044
31 May 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084966
17 May 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1424305
15 February 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879538
11 January 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 182025
11 January 1996
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 881713
14 December 1995
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190817
4 December 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 874844
5 October 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1191375
12 July 1995
MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882867
9 June 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 37033
11 April 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 86206
5 April 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1164164
27 March 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1141538
2 February 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161509
12 January 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 175139
12 January 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1176034
20 October 1994
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177865
8 August 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868239
8 August 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869678
13 July 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861744
30 May 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 113286
22 April 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171018
21 April 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171015
15 April 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168334
7 April 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1167677
5 April 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857555
5 April 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857583
31 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857551
2 March 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854276
3 February 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855216
6 December 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1162864
1 December 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 16687
30 November 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852504
16 November 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 841942
15 November 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836514
8 November 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 963203
29 October 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842711
5 October 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158443
16 September 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1149964
23 August 1993
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 828809
22 August 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 99760
12 August 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842925
29 July 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157249
22 July 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845085
20 April 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 75048
20 April 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 835032
1 April 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 841673
28 January 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842171
14 January 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142171
7 January 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 666674
31 December 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 7844
23 December 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135312
14 October 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265091
31 August 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250332
8 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 147910
17 June 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266708
4 June 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266707
18 March 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1270469
14 January 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960144
17 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1260349
2 October 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255908
27 August 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250578
21 February 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1302910
15 February 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917357
14 December 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 929882
29 November 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219852
21 November 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913350
13 November 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930537
30 August 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 901037
28 August 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232147
22 August 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906228
14 June 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227986
23 May 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930749
28 February 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222313
26 February 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 915554
23 January 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 912917
23 January 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937672
12 July 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890743
16 May 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 970522
19 April 1989
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199636
25 January 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1044740
14 December 1988
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897883
11 October 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887623
25 August 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038499
12 August 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344338
5 August 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037190
19 July 1988
Damage Survey · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341194
14 June 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897983
9 March 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337370
3 December 1987
Hull Examination · COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029657
25 August 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310316
17 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342426
13 July 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016624
16 June 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1315701
6 April 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021874
23 March 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327310
23 February 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309876
2 February 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011893
24 September 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319666
30 June 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993618
2 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998884
7 January 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 990116
4 December 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993779
29 October 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301940
31 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 984031
19 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 981884
15 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 983802
16 October 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1282867
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 November 2005
Resolved
Repair / replace the emergency light in the forward E/R escape trunk.
Due 7 December 2005
Resolved 3 January 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 November 2005
Resolved
The light fixture in the forward E/R escape trunk is being used as a connection box for the CCTV UPS's. Remove all cables that are not part of the lighting branch circuit IAW 46CFR111.75-20(c)
Due 30 December 2005
Resolved 26 January 2006
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 24 August 2005
Resolved
Vessel must provide portable containment as required by 33CFR155.320(b)
Due 22 September 2005
Resolved 22 September 2005
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 25 May 2005
Resolved
Prove proper operation of both ship service boilers prior to placing back in service.
Action required: 705 - Other - as specified
Resolved 18 October 2005
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 25 May 2005
Resolved
Install the proper weak link on the lifefloats.
Due 9 June 2005
Resolved 8 June 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 May 2005
Resolved
Clean all lenses for the mast head lights.
Due 9 June 2005
Resolved 8 June 2005
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 December 2004
Resolved
OWS oil discharge pipe dumps back to the E/R bilge vs. the sludge tank. Vessel must connect the OWS oil discharge pipe to the sludge tank prior to using the OWS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 January 2005
Resolved 5 January 2005
Resolution: Vessel connected the OWS oil discharge pip to the sludge tank. OWS tested sat.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 December 2004
Resolved
Install a metal plate to cover the hole in the door that was left behind went the old locks were removed.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 10 December 2004
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 September 2004
Resolved
Replace the fresh water supply flex hose to the #2 SSDG with an approved type.
Due 13 October 2004
Resolved 5 October 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 September 2004
Resolved
Guard on the #2 SSDG must be repaired.
Due 13 October 2004
Resolved 5 October 2004
Engineering › Generator (propulsion-electric) › Junction Box
Issued 22 September 2004
Resolved
Repair the start solenoid on the #2 SSDG and tighten the "J" box.
Due 13 October 2004
Resolved 5 October 2004
Engineering › Compressed Air System (start air) › Valve
Issued 22 September 2004
Resolved
Replace and test the start air solenoid on the #1 SSDG.
Due 15 December 2004
Resolved 18 March 2005
Resolution: Tested Sat.
-PTT
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 September 2004
Resolved
Replace the fresh water flex hose on the #1 SSDG with an approved type.
Due 13 October 2004
Resolved 5 October 2004
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 22 September 2004
Resolved
Replace the lagging on the steam pipes for the relief valves on the #2 ship service boiler.
Due 13 October 2004
Resolved 5 October 2004
Engineering › Steering Gear System › Trick Wheel
Issued 22 September 2004
Resolved
Remove the old trick wheel operating instructions in the NY end of the steering compartment.
Due 13 October 2004
Resolved 5 October 2004
Engineering › Steering Gear System › Rudder
Issued 22 June 2004
Resolved
Ferry surged hard to port when the synchro-transmitter on the NY end, #2 steering pump/motor combination failed. Caused believed to be a loose bearing around the shaft to the follow-up that kept the gears meshing properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Electrical › Electric Generation Source (service) › Generator
Issued 1 June 2004
Resolved
Replace 2 leaking jacket water gasketson the #2 SSG.
Condition: Improper/Lack of Maintenance
Due 8 June 2004
Resolved 14 June 2004
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 1 June 2004
Resolved
Replace electrical cord in galley on cookie warmer.
Due 8 June 2004
Resolved 14 June 2004
Electrical › Electric Generation Source (service)
Issued 4 March 2004
Resolved
Make proper, permanent repairs IWO #1 SSG and conduct operational test.
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 2 April 2004
Resolution: Witnessed sat operational test of #1 SSG.
Engineering › Diesel Engine (propulsion-electric)
Issued 15 December 2003
Resolved
Submit damage assessment survey, make permanent and proper repairs, and prove proper operation of the propulsion system prior to carrying passengers. LEGACY COMPONENT DESC: Broken Bracket/Damage
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 December 2003
Resolved 11 January 2004
Resolution: Rcvd report regarding proper operation of propulsion system.
Engineering › Compressed Air System (control) › Piping
Issued 12 December 2003
Resolved
Cracked 1/8 inch pipe nipple on #2 main engine air supply to governor.
Due 12 December 2003
Resolved 12 December 2003
Resolution: Received signed statement from Chief Engineer of the vsl that the pipe nipple was replaced and the #2 main engine was tested and fully operational.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 December 2003
Resolved
Repair or replace stbd lifering light with cracked housing.
Due 4 December 2003
Resolved 4 December 2003
Resolution: Light replaced on the spot.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 December 2003
Resolved
Missing globe over light in female head closet.
Due 4 December 2003
Resolved 4 December 2003
Resolution: Globe replaced on the spot.
Lifesaving › Rescue Boat
Issued 4 December 2003
Resolved
Weight test NY end/Brooklyn side fwd rescue boat davit arm deeply pitted and wasted through in one area. LEGACY COMPONENT DESC: Davit
Due 10 December 2003
Resolved 5 December 2003
Resolution: Rescue boat satisfactorily weight tested to 600 lbs.
Lifesaving › Rescue Boat
Issued 4 December 2003
Resolved
Submit proposal adressing permanent repair to wasted davit arm. LEGACY COMPONENT DESC: Davit
Due 10 December 2003
Resolved 5 December 2003
Resolution: Proposal received by CG stating that they will replace wasted davit arm.
Construction/Loadline › Hull
Issued 4 December 2003
Resolved
Submit proposal to address buckled under deck longs above rescue boats on NY end (Brooklyn/NJ sides) and SI end (Brooklyn side) LEGACY COMPONENT DESC: Longitudinal Frame
Due 10 December 2003
Resolved 5 December 2003
Resolution: Proposal received by CG stating that they will C/R and insert damaged UDL''s
Engineering › Pressure Vessel
Issued 4 December 2003
Resolved
Provide specifications for installed air receiver in generator room. LEGACY COMPONENT DESC: Air Receiver
Due 10 December 2003
Resolved 5 December 2003
Resolution: Proper approval plate found (it had been welded over, but readable)
Lifesaving › Rescue Boat
Issued 4 December 2003
Resolved
Replace wasted davit arm on the NY end / Brooklyn side fwd rescue boat. LEGACY COMPONENT DESC: Davit Arm
Due 31 January 2004
Resolved 26 January 2004
Resolution: Davit arm fabricated and installed properly.
Lifesaving › Rescue Boat
Issued 4 December 2003
Resolved
Weight test rescue boat davit arm to 1.1 times "B" weight (1490 lbs) LEGACY COMPONENT DESC: Davit Arm
Due 31 January 2004
Resolved 26 January 2004
Resolution: Davit arm weight tested to 1.1 times "B" Weight (1500 lbs), sat.
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 18 November 2003
Resolved
Prove proper operation of the #2 and #3 main propulsion generators prior to carrying passengers
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 November 2003
Resolved 18 November 2003
Resolution: Received fax report from Chief Engineer attesting to the satisfactory operation of propulsion system.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 17 October 2003
Resolved
Operationally test installed relif valves and alarms on #2 heating boiler. LEGACY COMPONENT DESC: Relief Valves/Alarms
Due 16 November 2003
Resolved 19 November 2003
Resolution: Satisfactorily tested relief valves and alarms on #2 boiler.
Electrical › Electric Generation Source (service)
Issued 17 October 2003
Resolved
Make proper repairs to #1 SSG to satisfaction of attending [name withheld]: Generator
Due 6 December 2003
Resolved 3 December 2003
Resolution: Windings replaced and generator operationally tested in presence of MI.
Construction/Loadline › Hull › Bottom Plating
Issued 24 July 2003
Resolved
Clean and gauge as needed to outboard side of NY end fuel tank at hull plating interface.
Due 6 August 2003
Resolved 6 August 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 July 2003
Resolved
Make steering compartment and fuel tank compartment on Staten Island end available forinspection (remove oily residue).
Due 6 August 2003
Resolved 6 August 2003
Construction/Loadline › Hull › Bottom Plating
Issued 24 July 2003
Resolved
Clean and gauge side shell plating IWO MSD tank chlorine spills.
Due 6 August 2003
Resolved 6 August 2003
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 July 2003
Resolved
Remove rubber boot IWO #3 stbd main engine overboard pipe & flange or butt weld.
Due 6 August 2003
Resolved 6 August 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 July 2003
Resolved
Clean and make avaiable for inspection area IWO rudder post leak - SI end.
Due 6 August 2003
Resolved 6 August 2003
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 July 2003
Resolved
Submit repair proposal IWO both shaft alley transverse bulkhead wasted areas as per U/T report dated 13 MAR 03.
Due 24 July 2003
Resolved 24 July 2003
Engineering › Sea-water System (primary cooling) › Valve
Issued 14 July 2003
Resolved
Make available for inspection all sea valves, sea chest, rudder pintles.
Due 24 July 2003
Resolved 24 July 2003
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 14 July 2003
Resolved
Make all internal spaces gas free and submit copy of Marine Chemist Certificate to USCG.
Due 24 July 2003
Resolved 24 July 2003
Construction/Loadline › Hull › Bottom Plating
Issued 14 July 2003
Resolved
Submit repair proposal to change hull plating at wasted area between frames/fuel tank under crew accommodation space.
Due 24 July 2003
Resolved 24 July 2003
Fire Fighting › Structural Fire Protection - General
Issued 14 July 2003
Resolved
Replace missing SFP Insullation as needed at NY end, last 3 voids/compartments.
Due 6 August 2003
Resolved 6 August 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 June 2003
Resolved
20 second time delay discharging early (2 tests conducted for average of 18 seconds (19, 17)). Make proper permanent repairs prior to operating. LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2003
Resolution: Witnessed sat test of time delays.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 3 June 2003
Resolved
Prove proper operation of 5 clogged sprinkler heads on car deck. Location (NY end as bow): #1 zone, stbd side fwd (2); #3 zone, stbd side fwd most (1); #4 zone, center fwd most (1); #5 zone, stbd sie aftermost (1). LEGACY COMPONENT DESC: Nozzles
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 6 June 2003
Resolution: Witnessed sat test of sprinkler system.
Construction/Loadline › Hull
Issued 7 March 2003
Resolved
Provide gauge readings for the following locations: (NY end as bow), (1) Steering compt IWO rudder stock (heating line) and bottom plate; (2) Shaft alley IWO fwd bkhd and side shell P/S; (3) Crew space hull plating under shower drain. S.I. end as bow, (3) Shaft alley IWO fwd bkhd & side shell P/S LEGACY COMPONENT DESC: Hull Plating
Due 4 April 2003
Resolved 18 March 2003
Resolution: Gauging report received.
Pollution Prevention/Response › Prevention Equipment
Issued 7 March 2003
Resolved
Make proper repairs and prove proper operaion of OWS. OWS cannot be used prior to repairs and to satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 19 April 2003
Resolved 4 March 2004
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 23 December 2002
Resolved
Tube leak found on #1 boiler by vessel crew and boiler taken out of service. Tube repaired and hydro tested to 150 psi. Boiler is out of service until operational tests are conducted.
Action required: 705 - Other - as specified
Resolved 26 December 2002
Resolution: Witnessed operational test of #1 boiler. Boiler placed back in service.
Engineering › Compressed Air System (start air)
Issued 5 December 2002
Resolved
Pressure relief valve on #2 air receiver would not seat during pressure test. Repair/replace pressure relief valve on #2 air receiver. LEGACY COMPONENT DESC: Valve
Due 15 December 2002
Resolved 10 December 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 5 December 2002
Resolved
Low lube oil pressure shutdown inoperable on #1 SSG. Repair/replace prior to operation of equipment.
Due 15 December 2002
Resolved 10 December 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 22 November 2002
Resolved
Make repairs to #1 boiler burner assembly & prove proper operation of the boiler prior to putting boiler in service.
Due 5 December 2002
Resolved 5 December 2002
Resolution: Found satisfactory repairs during 2nd QTR inspection.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 3 January 2002
Resolved
THE #1 BOILER WILL NOT BE PUT INTO USE UNTIL THE BURNER ASSEMBLY IS REPLACED AND A COMPLETE BOILER OPERATIONAL TEST IS CONDUCTED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Fuel Oil Burner
Condition: Design Flaw
Due 15 February 2002
Resolved 18 March 2002
Lifesaving
Issued 20 September 2001
Resolved
Provide proof of current satisfactory N.Y.C. Health Inspection.
Condition: Unknown
Due 30 September 2001
Resolved 4 October 2001
Lifesaving
Issued 20 September 2001
Resolved
Permanantly mount all electrical applicances including soda pump motors, refers, food machines, register etc. in concession area.
Condition: Unknown
Due 30 September 2001
Resolved 4 October 2001
Engineering
Issued 20 September 2001
Resolved
Conduct proper operational tests of #1 Boiler unit in CG presence prior to operation.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 20 September 2001
Resolved
Repair/replace broken soda machine electrical outlets.
Condition: Unknown
Due 30 September 2001
Resolved 4 October 2001
Lifesaving
Issued 20 September 2001
Resolved
Repair/replace cover to closet w/electrical pump.
Condition: Unknown
Due 30 September 2001
Resolved 4 October 2001
Accommodation/Occupational Safety
Issued 20 September 2001
Resolved
Renew Brooklyn side/Staten Island end #2 deck scupper pipeline leaking to main deck accom area/fan room at next dry-dock.
Condition: Unknown
Due 31 March 2003
Resolved 27 August 2002
Resolution: Cleared by [name withheld].
Accommodation/Occupational Safety
Issued 8 August 2001
Resolved
COMPLETE AS BUILT VERIFICATION FOR INSTALLATION OF NEW CONCESSION STAND IAWNYCMI EXAMINED PLANS AND NYCMI LTR PR-010086. PLANS ARE MAINTAINED IN JOHN F. KENNEDY VESSEL FILE.
Condition: Unknown
Due 31 January 2002
Resolved 4 June 2002
Electrical
Issued 7 June 2001
Resolved
DETERMINE SOURCE/REPAIR LOW VOLTAGE GROUND 2K OHM IN 120 DC POSITIVE LINE.
Condition: Unknown
Due 21 June 2001
Resolved 6 July 2001
Navigation
Issued 7 June 2001
Resolved
PROVE PROPER OPERATION OF THE STATEN ISLAND SIDE RADAR (FURUNO).
Condition: Unknown
Due 14 June 2001
Resolved 18 June 2001
Electrical
Issued 7 June 2001
Resolved
PROVE PROPER OPERATION OF THE BRIDGE VENTILATION TRIPS.
Condition: Unknown
Due 7 June 2001
Resolved 18 June 2001
Navigation
Issued 7 June 2001
Resolved
PROVIDE CURRENT DEVIATION TABLE.
Condition: Unknown
Due 21 June 2001
Resolved 6 July 2001
Unknown
Issued 7 June 2001
Resolved
LABEL BRIDGE VENTILATION TRIPS.
Condition: Unknown
Due 7 June 2001
Resolved 18 June 2001
Accommodation/Occupational Safety
Issued 7 June 2001
Resolved
PROVIDE PROPOSAL FOR HOT WATER AVAILABILITY FOR PASSENGER BATHROOMS.
Condition: Unknown
Due 31 March 2003
Resolved 25 July 2002
Engineering
Issued 7 June 2001
Resolved
PROVE PROPER OPERATION OF #2 MAIN ENGINE GOVERNOR SPEED CONTROL.
Condition: Unknown
Due 21 June 2001
Resolved 6 July 2001
Lifesaving
Issued 22 January 2001
Resolved
PROVIDE PROOF OF LIFERAFT SERVICING PRIOR TO COMMERCIAL OPERATIONS.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Engineering
Issued 22 January 2001
Resolved
Do not conduct operational testing of newly installed #2 Auxiliary heating boiler until approved plans received and reviewed by ABS Technical Divisionand USCG/MSC.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Electrical
Issued 22 January 2001
Resolved
Replace all missing light fixture globes and guards in all spaces as needed.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Accommodation/Occupational Safety
Issued 22 January 2001
Resolved
Replace all broken seating boards in passenger spaces (exterior and interior) as needed.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Accommodation/Occupational Safety
Issued 12 July 2000
Resolved
Properly clean snack bar to proper sanitation standards, and to satisfaction of CG inspector. Snack bar not to be used until corrected._x001C_
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Lifesaving
Issued 12 July 2000
Resolved
Provide training manual on board vessel IAW 46 CFR 199.180(a).
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Electrical
Issued 19 June 2000
Resolved
Demonstrate satisfactory operation of ship's vital service generator. Man vessel with (1) additional marine engineer able to place on line the Stby SSDG at all times vessel is operating until ship's vital service generator has been proven operational.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Fire Fighting
Issued 1 June 2000
Resolved
Repair ship's primary fire pump prior to further operations
Condition: Unknown
Due 2 June 2000
Resolved 2 June 2000
Electrical
Issued 7 April 2000
Resolved
Demonstrate proper operation of Vital Service generator overspeed trip prior to further operation. Additional Marine Engineer to be carried on board vessel until repairs are completed.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Engineering
Issued 7 April 2000
Resolved
Demonstrate proper operation of #3 MDE JW high temp alarm
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Accommodation/Occupational Safety
Issued 4 February 2000
Resolved
Repair or replace ship's marine sanitation device holding tanks to prevent sewer and chlorine gas from entering ship's engine room prior to further operations.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Engineering
Issued 19 January 2000
Resolved
Renew governor drive gear of #1 SSDG prior to further operations.
Condition: Unknown
Due 25 January 2000
Resolved 25 January 2000
Engineering
Issued 19 January 2000
Resolved
Correct excessive rough operation of emergency generator
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Fire Fighting
Issued 19 January 2000
Resolved
Renew CO2 system piping diagram in CO2 room.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Engineering
Issued 19 January 2000
Resolved
Prove proper operation of #4 MDE oil pressure failure switch prior to further operation.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Electrical
Issued 20 October 1999
Resolved
Repair leaking fitting on the E-Gen fuel pump.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Electrical
Issued 20 October 1999
Resolved
Install cover on E-Gen windings.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Electrical
Issued 20 October 1999
Resolved
Repair leaking head gasket on emergency generator.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Electrical
Issued 20 October 1999
Resolved
Install exhaust lagging on #1 SSDG.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Lifesaving
Issued 20 October 1999
Resolved
Provide liferafts for 36 persons IAW 46 CFR 75.10-20(b) & 75.10-25 (1995 edition).
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Engineering
Issued 18 October 1999
Resolved
Demonstrate satisfactory operation of OWS upon completion of repairs or replacement of same.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Electrical
Issued 30 September 1999
Resolved
Effect permanent repairs to grounded main propulsion motors to restore megger readings to acceptable levels. Vessel is to remain out of service until repairs have been completed and verified as acceptable by attending USCG Marine Inspector or ABS Surveyor.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Construction/Loadline
Issued 22 September 1999
Resolved
Effect permanent repairs to holed hull IWO SI end shaft alley compt. Docking plug upset by strike on unknown underwater object. Crack resulted in hull plate immediately adjacent to vertical keel member approx 4 inches aft of fwd bulk. Vessel not to operate prior to completion of repairs.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Engineering
Issued 14 April 1999
Resolved
PROVE PROPER OPERATION OF #1 HEATING BOILER & CONDUCT REQUIRED TESTS TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Engineering
Issued 19 January 1999
Resolved
IDENTIFY SOURCE OF MINOR EXHAUST LEAK IN #1 S/S BOILER CASING IWO EXHAUST UPTAKE
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Engineering
Issued 19 January 1999
Resolved
IDENTIFY SOURCE OF MAJOR BOILER EXHAUST LEAK AND REPAIR SAME FOR #1 S/S BOILER.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Accommodation/Occupational Safety
Issued 19 January 1999
Resolved
REPAIR BROKEN WHEELHOUSE WINDSHIELD WINDOW, 1ST WINDOW TO RIGHT OF CENTER LINE
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Engineering
Issued 19 January 1999
Resolved
REPAIR FUEL OIL LEAK AT #1 S/S BOILER BURNER SUPPLY LINE.
Condition: Unknown
Due 1 February 1999
Resolved 4 February 1999
Engineering
Issued 14 January 1999
Resolved
REPAIR WATER LEAK IN #3 MDE RAW WATER STRAINER COVER
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Engineering
Issued 14 January 1999
Resolved
REPAIR FUEL LEAK ON BURNER FUEL INLET TO #1 SS BOILER
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Electrical
Issued 14 January 1999
Resolved
REPAIR LOOSE MOUNTING HARDWARE TO EMERGENCY GENERATOR DISTRIBUTION PANEL.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Accommodation/Occupational Safety
Issued 14 December 1998
Resolved
REPAIR HOLES ON TANK TOPS OF #1 AND #3 STAGE TANKS OF THE MSD SYSTEM TO THESATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 December 1998
Resolved 15 December 1998
Accommodation/Occupational Safety
Issued 14 December 1998
Resolved
PROVE PROPER OPERATION OF MSD VENTILATION SYSTEM TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 December 1998
Resolved 15 December 1998
Navigation
Issued 28 October 1998
Resolved
Stencil steering gear instructions in steering gear compartments.
Condition: Unknown
Due 28 November 1998
Resolved 4 November 1998
Lifesaving
Issued 28 October 1998
Resolved
Renewlines for lifefloats on Staten Island/Brooklyn end.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Lifesaving
Issued 28 October 1998
Resolved
Provide a means of separation between child and adult size lifejackets.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Construction/Loadline
Issued 16 April 1998
Resolved
Make doorway directly over field exciters in ER weather-tight to stop leak.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Engineering
Issued 22 December 1997
Resolved
CREW MEMBER MUST INSPECT AND LOGGED THE CONDITION OF THE BEARING EVERY 30 MINUTES UNTIL BEARING IS REPLACED OR REPAIRED.
Condition: Unknown
Due 29 December 1997
Resolved 30 December 1997
Engineering
Issued 22 December 1997
Resolved
PROVIDE LUBE OIL SAMPLE REPORT FOR THE DAMAGE BEARING (SEE ITEM 1).
Condition: Unknown
Due 22 December 1997
Resolved 22 December 1997
Engineering
Issued 22 December 1997
Resolved
LINE SHAFT BEARING WAS DAMAGED; BEARING LOCATED FOWARD (NY END) MAIN PROPULSION.
Condition: Unknown
Due 29 December 1997
Resolved 30 December 1997
Unknown
Issued 22 December 1997
Resolved
REPLACE OR REPAIR SENSOR VALVE FOR THE OWS. THE VALVE DOESN'T STAY IN THE CLOSE POSITION, THEREFORE, WATER CONTINUES RUNNING INTO THE BILGES.
Condition: Unknown
Due 29 December 1997
Resolved 30 December 1997
Engineering
Issued 22 December 1997
Resolved
VSL REP MUST REPORT IMMEDIATLY EXCESSIVE VIBRATION AND OR ANY RISE OF TEMPERTURE TO THE COAST GUARD.
Condition: Unknown
Due 29 December 1997
Resolved 30 December 1997
Engineering
Issued 22 December 1997
Resolved
ALL OTHER SHAFT BEARING ASSOCIATED TO THE FOWARD END (NY) MAIN PROPULSION MUST BE CHECKED EVERY HOUR.
Condition: Unknown
Due 29 December 1997
Resolved 30 December 1997
Engineering
Issued 22 December 1997
Resolved
VSL MUST MAKE BEARING AVAILABLE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 23 December 1997
Resolved 30 December 1997
Engineering
Issued 19 December 1997
Resolved
PROVIDE QUALIFIEDBOILER ATTENDANT TO ATTEND HEATING BOILERS AT ALL TIMES WHEN BOILERS ARE IN OPERATION.
Condition: Unknown
Due 19 December 1997
Resolved 7 January 1998
Engineering
Issued 18 December 1997
Resolved
CG 835 ITEM M01 ISSUED TO PROVE PROPER OPERATION OF VISUAL ALARMS ON #1 & #2 HEATING BOILERS
Condition: Unknown
Due 31 January 1998
Resolved 9 January 1998
Engineering
Issued 18 December 1997
Resolved
CG 835 ITEM M02 ISSUED TO REPAIR WIRING TO #1 BOILER FUEL PUMP IWO JUNCTIONBOX.
Condition: Unknown
Due 31 January 1998
Resolved 9 January 1998
Fire Fighting
Issued 18 December 1997
Resolved
CG 835 ITEM D02 ISSUED TO REPLACE 2 IDENTIFIED SPRINKLER HEADS IN ZONE 4. #'S 1 & 2.
Condition: Unknown
Due 31 January 1998
Resolved 9 January 1998
Fire Fighting
Issued 18 December 1997
Resolved
CG 835 ITEM D01 ISSUED TO REPAIR TWO LEAKING VALVES IWO ENGINE ROOM ENTRANCE.
Condition: Unknown
Due 31 January 1998
Resolved 9 January 1998
Fire Fighting
Issued 18 December 1997
Resolved
CG 835 ITEM M05 ISSUED TO PROVIDE PROOF OF SERVICING TO CO2 BOTTLE IN MAIN ENGINE ROOM STATION #11.
Condition: Unknown
Due 31 January 1998
Resolved 9 January 1998
Electrical
Issued 18 December 1997
Resolved
CG 835 ITEM M04 ISSUED TO INSTALL GLOBES & GUARDS ON LIGHTING FIXTURES IN CO2 ROOM.
Condition: Unknown
Due 31 January 1998
Resolved 9 January 1998
Electrical
Issued 18 December 1997
Resolved
CG 835 ITEM M03 ISSUED TO REPAIR OIL LEAK ON TURBO CHARGER ON #1 SSD GEN.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Accommodation/Occupational Safety
Issued 18 December 1997
Resolved
CG 835 ITEM D04 ISSUED TO REMOVE CURRENT HOUSING FOR RADIO POWER UNITS, BRIDGE HOUSE, BOTH ENDS.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Accommodation/Occupational Safety
Issued 18 December 1997
Resolved
CG 835 ITEM D05 ISSUED TO PROVIDE PROPER HOUSING FOR RADIO POWER UNITS, BRIDGE HOUSE, BOTH ENDS._x001C_
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Lifesaving
Issued 18 December 1997
Resolved
CG 835 ITEM D03 ISSUED TO PROVIDE PROPER RETROFLECTIVE TAPE ON L/R, OUTSIDEBRIDE HOUSE, BOTH ENDS.
Condition: Unknown
Due 31 January 1998
Resolved 9 January 1998
Electrical
Issued 9 December 1997
Resolved
Provide plans for modifications to vital systems & emergency generators foroverspeed trips, low lube oil, and high jacket cooling water temperature shutdowns and alarms.
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Engineering
Issued 9 December 1997
Resolved
Prove proper operation of all automatic controls, #1 heating boiler._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Engineering
Issued 18 November 1997
Resolved
Set & seal safety valve in presence of Marine Inspector prior to placing #1heating boiler back in service.
Condition: Unknown
Due 31 January 1998
Resolved 30 December 1997
Engineering
Issued 18 November 1997
Resolved
Perform tube repairs to #1 heating boiler
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Unknown
Issued 29 September 1997
Resolved
REPAIR COVER TO LIFEJACKET LOCKER LOCATED NEXT TO THE STATEN ISLAND PILOT HOUSE.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Unknown
Issued 29 September 1997
Resolved
REPAIR VENT PIPE LOCATED IN CENTER HOUSE OFFICERS HEAD.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Engineering
Issued 29 September 1997
Resolved
RENEW BROKEN GAUGE ON FUEL OIL PURIFIER.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Construction/Loadline
Issued 29 September 1997
Resolved
REPAIR ENGINE ROOM DOOR FROM MAIN DECK TO TOP OF LADDERS IN MACHINERY SPACES (MAKE WEATHER TIGHT).
Condition: Unknown
Due 30 November 1997
Resolved 31 October 1997
Electrical
Issued 29 September 1997
Resolved
REMOVE SPLICED WIRE TO SNAPPLE DRINK COOLER IN SNACK BAR.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Engineering
Issued 11 September 1997
Resolved
PROVE PROPER OPERATION OF THE OWS IN THE PRESENTS OF A MARINE INSPECTOR.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Engineering
Issued 11 September 1997
Resolved
REPACK THE NEW YORK END STERN TUBE PACKING GLAND TO THE SATISFACTION OF A MARINE INSPECTOR.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Engineering
Issued 11 September 1997
Resolved
Prove proper operation of #1 SSG starter.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Electrical
Issued 20 August 1997
Resolved
PROVIDE SECONDARY F-COIL OR OTHER MEANS TO PREVENT THE LOSS OF BRIDGE/ENG ROOM CONTROL'S IN THE EVENT OF THE LOSS OF THE F-COIL. SUBMIT PLANS FOR APPROVAL PRIOR TO INSTALLATION.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Unknown
Issued 6 August 1997
Resolved
PROVIDE PROOF THAT POTABLE WATER IS SAVE TO CONSUME.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Unknown
Issued 14 July 1997
Resolved
SUBMIT WRITTEN PLANS FOR MODIFICATIONS TO VITAL SYSTEMS & EMERGENCY GENERATORS FOR OVERSPEED TRIPS, LOW LUBE OIL AND HIGH COOLING WATER JACKET TEMPERATURE SHUTDOWNS AT LEAST 14 DAYS PRIOR IF COMPLIANCE DATE OF 26SEP97 CANNOT BE MET IAW CG-835S #M006 AND #M007 ISSUED 28FEB97 BY NYCMI.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Navigation
Issued 17 April 1997
Resolved
PROVE PROPER OPERATION OF STATEN ISLAND END AFT STEERING MOTOR TO THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 17 April 1997
Resolved 18 April 1997
Lifesaving
Issued 28 February 1997
Resolved
SHOW EVIDENCE OF MAINTENANCE AND PROPER OPERATION OF VEHICLE DECK PFD DROP BOXES.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Fire Fighting
Issued 28 February 1997
Resolved
INDICATE LOCATION OF APPLICATOR FOR FIRE STATION #24 IN ENGINE RM.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Fire Fighting
Issued 28 February 1997
Resolved
HAVE PORTABLE FIRE EXT SERVICED IF MARKED SERVICED MAR 1996.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Unknown
Issued 28 February 1997
Resolved
PROVIDE DECK PLUG IN SIE JERSEY SIDE ON WX DECK.
Condition: Unknown
Due 28 February 1997
Resolved 4 March 1997
Lifesaving
Issued 28 February 1997
Resolved
PAX ON VEHICLE DECK LIMITED TO 900 UNTIL MORE PFD'S PROVIDED.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Unknown
Issued 28 February 1997
Resolved
REMOVE TEMPORARY VENTILATION INTAKE COVER (WOOD) IN PORT AND STBD INTAKE FIDLEYS. REPLACE WITH A NON COMBUSTIBLE TEMP COVERS.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Electrical
Issued 28 February 1997
Resolved
PROVIDE PLANS OR EVIDENCE OF PLAN REVIEW FOR LIGHTING PANEL SNACK BAR BREAKER 10-L. AMPERAGE RATING ON PANELBOARD SCRATCHED OUT.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Electrical
Issued 28 February 1997
Resolved
PROVIDE PLAN REVIEW FOR MSD AND MSD MACERATOR BRAKERS ON MAIN SWITCHBOARD. RATED FOR 50A BUT HAS 90A BREAKER.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Engineering
Issued 28 February 1997
Resolved
MODIFY VITAL SERVICES GENERATOR SET TO ALLOW FOR COMPLETION OF OVERSPEED TEST.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Accommodation/Occupational Safety
Issued 28 February 1997
Resolved
Repair bulged deck in women's head.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Accommodation/Occupational Safety
Issued 28 February 1997
Resolved
CLEAN OR REMOVE "SNAPPLE" DRINK REEFER IN SNACK BAR.
Condition: Unknown
Due 28 February 1997
Resolved 4 March 1997
Accommodation/Occupational Safety
Issued 28 February 1997
Resolved
Clean deck drain and deck in snack bar. Snack bar is unsanitary and may notbe used until this CG-835 is cleared.
Condition: Unknown
Due 28 February 1997
Resolved 4 March 1997
Lifesaving
Issued 28 February 1997
Resolved
Have vessel master survey PFDs especially those with cotton straps.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Fire Fighting
Issued 28 February 1997
Resolved
REPACK EMERGENCY FIRE PUMP
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Accommodation/Occupational Safety
Issued 28 February 1997
Resolved
INSTALL GUARD ON COMPRESSOR IN SNACK BAR.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Unknown
Issued 28 February 1997
Resolved
PROVE PLAN REVIEW FOR LO PURIFIER HEATER BREAKER ON MAIN SWITCHBOARD (RATING IS FOR 40A BUT HAS 50A BREAKER).
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Engineering
Issued 28 February 1997
Resolved
CORRECT ALARM/CONTROL PROBLEMS WITH BOTH HEATING BOILERS
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Electrical
Issued 28 February 1997
Resolved
RENEW BREAKER DIRECTORY CARD IN POWER VENT PANEL CKT 1-2 SYMBOL 62-32.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Electrical
Issued 28 February 1997
Resolved
CLEAN VITAL SYSTEM GENERATOR STARTING & GENERAL ALARM BATTERY TRAYS
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Engineering
Issued 28 February 1997
Resolved
MODIFY EMERGENCY GENERATOR SET TO ALLOW FOR COMPLETION OF OVERSPEED, LOSS OF LUBE OIL SHUTDOWN, HIGH COOLING WATER TEMP ALARM TESTS AS REQUIRED BY 46CFR 112-50-1(a)
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Accommodation/Occupational Safety
Issued 28 February 1997
Resolved
CORRECT WIRING CONNECTION TO JUNCTION BOX ON MSD
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Engineering
Issued 28 February 1997
Resolved
DO NOT OPERATE BOILERS EXCEPT FOR TESTING AND ADJUSTMENT UNTIL SAFETIES SETAND SEALED.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Engineering
Issued 28 February 1997
Resolved
PROVIDE PROPER OPERATION OF ALL SAFETY DEVICES ON #3 MDE.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Unknown
Issued 28 February 1997
Resolved
HYDROSTATICALLY OR INTERNALLY EXAMINE AIR RECIEVERS.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Navigation
Issued 24 January 1997
Resolved
Vessel may not operate until repairs have been made to the New York end forward motor coupling for the steering pump, to the satisfaction of the attending ABS inspector. A verbal report may be given to the Prevention and Compliance Duty Officer(PCD) from ABS.
Condition: Unknown
Due 24 February 1997
Resolved 28 January 1997
Unknown
Issued 19 November 1996
Resolved
REPAIR DOORS UNDER BENCHES FOR LIFEJACKETS. DOORS WON'T STAY SHUT.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Unknown
Issued 19 November 1996
Resolved
CLEAN OFF VENTS ON SNACK BAR DECK PORT AND STARBOARD MIDSHIPS.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Unknown
Issued 19 November 1996
Resolved
INSTALL DECK DRAIN SCREENS ON DRAINS LOCATED IN PASSENGER SPACES ON VEHICLEDECK.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Unknown
Issued 19 November 1996
Resolved
CLEAN OUT UNDER PASSENGER SEATS ON VEHICLE DECK PORT AND STBD, FORE AND AFT.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Electrical
Issued 19 November 1996
Resolved
LABEL POWER PANEL IN OFFICERS LOCKER ROOM STATEN ISLAND END.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 19 November 1996
Resolved
SECURE MINOR OIL LEAK IN LUBE OIL COOLER PIPING FOR #3 MDE.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Electrical
Issued 19 November 1996
Resolved
BLANK OFF SPARE BREAKERS IN POWER PANEL IN OFFICERS LOCKER ROOM NY SIDE.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Engineering
Issued 19 November 1996
Resolved
SECURE MINOR FUEL LEAK AT #1 SSDG F/O PUMP.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Electrical
Issued 19 November 1996
Resolved
PROPERLY WIRE REFRIGERATOR IN ENGINEROOM.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Engineering
Issued 19 November 1996
Resolved
SECURE AIR LEAK IN AIR START SYSTEM #1 SSDG.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Fire Fighting
Issued 19 November 1996
Resolved
INSTALL PROPER "Y" GATE CONNECTION AT FIRE STATION LOWER LEVEL AUX MACH. SPACE STATEN ISLAND END.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Electrical
Issued 19 November 1996
Resolved
INSTALL PRESSURE FITTINGS FOR WIRE CONNECTIONS FOR VENT SHUT DOWNS IN BOTH WHEEL HOUSES.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Fire Fighting
Issued 19 November 1996
Resolved
INSTALL RELEASING SWITCH FOR FIRE SCREEN DOOR #6.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Fire Fighting
Issued 19 November 1996
Resolved
ADJUST FIRE SCREEN DOOR #6 TO ALLOW FOR MANUAL CLOSING OF DOOR WITHOUT USE OF RELEASING SWITCH.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 19 November 1996
Resolved
INSTALL LAGGING ON EXPOSED STEAM PIPING ON UNIT HEATERS IN PASSENGER SPACES.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Navigation
Issued 19 November 1996
Resolved
CLEAN SOOT OFF MAST RANGE LIGHTS.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Electrical
Issued 19 November 1996
Resolved
LABEL STRIP HEATER BREAKERS ON SWITCHBOARD.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Electrical
Issued 19 November 1996
Resolved
LABEL ALL EMERGENCY LIGHTS IN ENGINE ROOM AND AUX ENG ROOMS WITH AN "E".
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 19 November 1996
Resolved
CLEAN FOAM TYPE LIFEJACKETS, JACKETS NO LONGER INTERNATIONAL ORANGE DUE TO DIRT BUILD UP. CLEANSING SHALL BE IAW 46CFR SUBPART Q.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Unknown
Issued 19 November 1996
Resolved
CLEAN VENT SYSTEM FOR SNACK BAR.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 19 November 1996
Resolved
REMOUNT PULL DOWN HOOKS FOR PFDs ON STATEN ISLAND END.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 19 November 1996
Resolved
REPAIR SNACK BAR OVERHEAD.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Unknown
Issued 19 November 1996
Resolved
CLEAN DUST BUILD UP AND DEBRIS IN AND AROUND SNACK BAR REEFER COMPRESSOR.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Fire Fighting
Issued 19 November 1996
Resolved
READJUST #7 FIRE SCREEN DOOR, CLOSES TOO SLOW.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 6 September 1996
Resolved
Resecure buoyant apparatus.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Accommodation/Occupational Safety
Issued 6 September 1996
Resolved
Remove lounge chairs from New York end crews lounge.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Lifesaving
Issued 6 September 1996
Resolved
Remove adult life jackets that are mixed in with children. To clear this item all children jackets are to be place in vicinity of locker for proper count._x001C_
Condition: Unknown
Due 20 September 1996
Resolved 13 September 1996
Fire Fighting
Issued 6 September 1996
Resolved
Remove excessive gear from fire hose stations.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Fire Fighting
Issued 5 August 1996
Resolved
SUPPLY COPY OF FIRE EXTINGUISHER REPORT.
Condition: Unknown
Due 19 August 1996
Resolved 9 August 1996
Electrical
Issued 5 August 1996
Resolved
LABEL BREAKERS OR SUPPLY CARD FOR ELECTRICAL DISTRIBUTION PANEL._x001C_
Condition: Unknown
Due 19 August 1996
Resolved 9 August 1996
Fire Fighting
Issued 5 August 1996
Resolved
PROVIDE COPY OF UP DATED FIRE AND SAFETY PLAN, ALSO SUPPLY ADDITIONAL COPY FOR ENGINE ROOM.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Lifesaving
Issued 5 August 1996
Resolved
LABEL PFD STOWAGE IN ENGINE ROOM._x001C_
Condition: Unknown
Due 19 August 1996
Resolved 26 August 1996
Accommodation/Occupational Safety
Issued 5 August 1996
Resolved
REMOVE SCAFFOLD PLANKING, BLOCKING ENGINE ROOM EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 5 August 1996
Resolved 9 August 1996
Engineering
Issued 5 August 1996
Resolved
PROVIDE EVIDENCE OF PLAN REVIEW APPROVAL FOR OILY WATER SEPARATOR._x001C_
Condition: Unknown
Due 19 August 1996
Resolved 26 August 1996
Electrical
Issued 5 August 1996
Resolved
INSTALL COVER FOR A/C OUTLETS FOR BOTH WHEELHOUSES._x001C_
Condition: Unknown
Due 19 August 1996
Resolved 26 August 1996
Fire Fighting
Issued 5 August 1996
Resolved
MAKE PERMANENT AND PROPER REPAIRS TO STATEN ISLAND END PORT SIDE WHEELHOUSEFIRE STATION. VALVE IS LEAKING BY._x001C_
Condition: Unknown
Due 19 August 1996
Resolved 26 August 1996
Engineering
Issued 5 August 1996
Resolved
REPLACE HAND RELIEF GEAR ON RELIFE VALVES FOR AIR RECEIVERS 1 AND 4._x001C_
Condition: Unknown
Due 26 August 1996
Resolved 6 September 1996
Electrical
Issued 27 June 1996
Resolved
#1 SSDG OVERHEATING TO 200 F. SUSPECT SUCTION VALVE DISC DROPPED OFF STEM.
Condition: Unknown
Due 3 July 1996
Resolved 27 June 1996
Electrical
Issued 31 May 1996
Resolved
VESSEL MAY CONTINUE TO OPERATE AND WILL HAVE #1 SHIP SERVICE GEN AS THE PRIMARY SOURCE OF POWER. THIS REQUIREMENT WILL BE IN EFFECT UNTIL REPAIRS ARE COMPLETED TO #2 SHIP SERVICE GEN AND PROVEN SATISFACTORY BY A USCG INSPECTOR BUT IN NO CASE LATER THAN 14 JUN 1996.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Electrical
Issued 31 May 1996
Resolved
REPAIR AND PROVE PROPER OPERATION OF #2 SHIP SERVICE GEN. TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR, TO BE COMPLETED NO LATER THAN 14 JUNE 1996.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Electrical
Issued 14 December 1995
Resolved
Prove proper operation of emergency generator.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Engineering
Issued 5 October 1995
Resolved
REPAIR LEAKING FUEL LINE #2 AUXILIARY BOILER.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Fire Fighting
Issued 5 October 1995
Resolved
REPLACE VALVE HAND WHEEL ON EMERGENCY FIRE PUMP DRAIN LINE.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Lifesaving
Issued 5 October 1995
Resolved
STENCIL "CHILDREN LIFE JACKETS" ON THE DESIGNATED STORAGE AREAS ON THE #2 DECK.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Engineering
Issued 5 October 1995
Resolved
FREE UP ALL DECK CAPS AND PROVE OPERATION OF HIGH/LOW SHUTTOFF VALVES AND STENCILE SAME VALVES.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Construction/Loadline
Issued 5 October 1995
Resolved
REMOVE EXCESS OIL IN GENERATOR ROOM BILGE.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Lifesaving
Issued 5 April 1995
Resolved
PROPERLY MARK NEW 15 PERSON LIFE FLOAT SI END STBD SIDE.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Engineering
Issued 5 April 1995
Resolved
PROVE PROPER OPERATION OF #2 BOILER SAFETY, TRIPS AND ALARMS.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Engineering
Issued 5 April 1995
Resolved
RE-RUN F.O. LINES FOR #1 BOILER AND SUPPORTS.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Navigation
Issued 5 April 1995
Resolved
PROVE PROPER OPERATION OF NAV LIGHT ALARM PANEL NY END (DOME, STERN) AND PROPERLY MARK PANEL.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Navigation
Issued 5 April 1995
Resolved
PROPERLY MARK S.I. END NAV LIGHT PANEL.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Electrical
Issued 5 April 1995
Resolved
REPLACE BURNT OUT LIGHT BULBS THROUGHOUT VESSEL, THEN IDENTIFY AND PROPERLY MARK ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Engineering
Issued 27 March 1995
Resolved
CONDUCT HYDROSTATIC TEST OF REMAINING AUX BOILER (#2) TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Engineering
Issued 2 February 1995
Resolved
CLEAN TUBES ON #1 BOILER. ONCE CLEAN, TUBES ARE TO BE INSPECTED BY A MARINE INSPECTOR. HYDRO WAS CONDUCTED 02FEB95. REHYDRO IF DETERMINED NECESSARY BY ATTENDING INSPECTOR. THIS REQ'T TO BE COMPLETED IN THE YARD BUT NO LATER THAN 16MAR95.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Construction/Loadline
Issued 20 October 1994
Resolved
PLUG TWO DRAINAGE HOLES IN DECK. MAIN DECK PORT SIDE STATEN ISLAND END FORWARD AND PORT SIDE MANHATTAN END FORWARD.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Construction/Loadline
Issued 20 October 1994
Resolved
PROVE PROPER OPERATION OF BILGE REACH ROD IN NEW YORK SIDE STEERING FLAT.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Construction/Loadline
Issued 20 October 1994
Resolved
PROVE PROPER OPERATION OF BILGE PUMP RELIEF VALVE.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Engineering
Issued 13 July 1994
Resolved
CLEAN/REPLACE VENT FLAME SCREENS ON VENTS NEAR FIRE STATION 16, PORT AFT DAY TANK ON CAR DECK ABOVE ENGINE ROOM ENTRANCE, AND VENT NEAR FIRE STATION19.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Electrical
Issued 13 July 1994
Resolved
REPLACE BURNED OUT BULB STBD SIDE STATEN ISLAND END IN EMERGENCY LIGHTING SYSTEM ON BRIDGE DECK.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Electrical
Issued 13 July 1994
Resolved
REPAIR/REPLACE LIGHTED EMERGENCY EXIT SIGN MAIN DECK STBD SIDE NEW YORK END.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Electrical
Issued 13 July 1994
Resolved
LABEL BREAKERS IN SNACK BAR POWER PANEL 66-20 WITH NUMBERS TO MATCH INDEX CARD.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Electrical
Issued 13 July 1994
Resolved
REPAIR/REPLACE STAIR TOWER TREADS: STATEN ISLAND END TO BRIDGE DECK 3RD FROM THE BOTTOM NEW YORK END TO BRIDGE DECK 6TH FROM THE TOP.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Engineering
Issued 5 April 1994
Resolved
PROVE PROPER OPERATION OF #1 BOILER SAFETY AND SET AND SEAL. BOILER IS NOTTO BE USED UNTIL THIS REQ'T IS CLEARED.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Fire Fighting
Issued 5 April 1994
Resolved
REPLACE BLEEDER VALVE ON FIRE STATION #2.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Fire Fighting
Issued 5 April 1994
Resolved
PROVE PROPER OPERATION OF VEHICLE DECK SPRINKLER SYSTEM. VSL IS NOT ALLOWED TO CARRY VEHICLES OTHER THAN MOTORCYCLES UNTIL COMPLETED. (A DECKHAND W/HOSE IS TO REMAIN ON DECK WHEN OPERATING & CARRYING MOTORCYCLES.)
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Engineering
Issued 5 April 1994
Resolved
PROVE PROPER OPERATION OF OWS. OWS IS NOT TO BE USED UNTIL COMPLETED.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Construction/Loadline
Issued 5 April 1994
Resolved
REPAIR WASTAGE ON MAIN DECK PORT AND STBD SIDE BELOW WINDOWS AS NEEDED.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Unknown
Issued 5 April 1994
Resolved
MAKE READY AND PERFORM A HYDROSTATIC TEST OF ALL (04) VSL AIR RECEIVERS TO 1.25 MAWP BY NEXT DRYDOCK, NLT 31JAN95.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Engineering
Issued 5 April 1994
Resolved
MAKE READY AND PERFORM A HYDROSTATIC TEST OF #1 & 2 AUX BOILER TO 1.5 MAWP BY NEXT DRYDOCK, NLT 31JAN95.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Lifesaving
Issued 5 April 1994
Resolved
PROVIDE 169 ADULT LIFE PRESERVERS, VSL IS RESTRICTED TO OPERATING WITH 4371PASSENGERS WHEN NO VEHICLES ARE CARRIED.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Electrical
Issued 31 March 1994
Resolved
PROVIDE PROTECTIVE GUARD ON GROUND DETECTION LAMPS ON MAIN SWITCHBOARD TO BE COMPLETED NLT 07APR94 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 April 1994
Resolved 18 April 1994
Engineering
Issued 30 November 1993
Resolved
PROVE PROPER OPERATION OF #2 AUX BOILER ALARMS/SHUTDOWNS AND SET/RESEAL SAFETY VALVE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATERTHAN 14DEC93. ABOVE UNIT WILL NOT BE OPERATED PRIOR TO COMPLIANCE WITH THISREQUIREMENT.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Unknown
Issued 30 November 1993
Resolved
REPAIR GROUND IN OILY WATER SEPERATOR UNIT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 14DEC93. ABOVE UNIT WILL NOT BE OPERATED PRIOR TO COMPLIANCE WITH THIS REQUIREMENT.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Accommodation/Occupational Safety
Issued 30 November 1993
Resolved
REPAIR LOOSE FLOOR TILES IN SNACK BAR AREA, SALON DECK, STATEN ISLAND END._x001C_
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Electrical
Issued 16 November 1993
Resolved
PROVE PROPER OPERATION OF THE "AUTO START" CAPABILITY AND THE ABILITY OF THE EMERGENCY GENERATOR TO CARRY A LOAD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 16NOV93.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Electrical
Issued 23 August 1993
Resolved
PROVE PROPER OPERATION OF # 4 PROPULSION MOTOR, STATEN ISLAND END, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. VESSEL NOT TO BE PLACED BACK IN SERVICE UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 23 August 1993
Resolved 23 August 1993
Navigation
Issued 12 August 1993
Resolved
PROVE PROPER OPERATION OF ENGINE ORDER TELEGRAPH PRIOR TO PLACING VESSEL INSERVICE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Electrical
Issued 20 April 1993
Resolved
VESSEL NOT TO OPERATE UNTIL CASUALTY #4 PROPULSION MOTOR, STATEN ISLAND END, REPAIRED AND TESTED TO SATISFACTION OF ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Engineering
Issued 28 January 1993
Resolved
PROVE PROPER OPERATION OF #2 AUX BOILER ALARMS AND SAFETIES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Engineering
Issued 28 January 1993
Resolved
CONDUCT HYDROSTATIC TEST OF #1 AUX BOILER IN THE PRESENCE OF MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Construction/Loadline
Issued 28 January 1993
Resolved
CORRECT LIFE PRESERVER STORAGE CONTAINERS TO REFLECT THE CONTENTS, EITHER REPLACE LIFE PRESERVERS OR REMOVE LABEL STATING CAPACITY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Fire Fighting
Issued 14 January 1993
Resolved
PROVE PROPER OPERATION OF FIRE SCREEN DOOR #6._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Accommodation/Occupational Safety
Issued 14 January 1993
Resolved
PROVE PROPER OPERATION OF VENTILATION SYSTEM FOR BOTH NY AND STATEN ISLAND STEERING COMPARTMENTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Accommodation/Occupational Safety
Issued 14 January 1993
Resolved
EFFECT REPAIRS TO REMOVE ACCESS COVER TO AS ORIGINAL CONDITION ON BOTH NY AND STATEN ISLAND STEERING COMPTARTMENT VENTILATION DUCTS AT MOTORS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Engineering
Issued 14 January 1993
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Fire Fighting
Issued 14 January 1993
Resolved
PROVE PROPER OPERATION OF GAUGE FOR #2 FIRE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Electrical
Issued 14 January 1993
Resolved
PROVE PROPER OPERATION OF AMP METER FOR VITAL SERVICE EMERGENCY GENERATOR._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Fire Fighting
Issued 31 August 1992
Resolved
HYDROSTATICALLY TEST FILL & INSTALL 34 FIXED CO2 EXTINGUISHING CYLINDERS & TEST OPERATION OF CO2 SYSTEM ALARMS & TIME DELAYS & PIPING. THE ABOVE ITEM TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR_x001C_ BEFORE VESSEL PLACED BACK IN SERVICE BUT NLT 09OCT92.
Condition: Unknown
Due 31 August 1992
Resolved 31 August 1992
Engineering
Issued 18 March 1992
Resolved
PRIOR TO PLACING THE #1 BOILER INTO SERVICE, PROVE PROPER OPERATION OF #1 BOILER'S SAFETY VALVE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Engineering
Issued 14 January 1992
Resolved
REPAIR EXHAUST LEAK IN EXHAUST STACK ON #1 SSG. REPAIR MUST BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 January 1992
Resolved 14 January 1992
Electrical
Issued 2 October 1991
Resolved
RENEW MISSING EXHAUST PIPE LOGGING FOR #1 AND #2 GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Electrical
Issued 2 October 1991
Resolved
REPAIR LUBE OIL ON #2 GENERATOR BY EXHAUST MANIFOLD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Construction/Loadline
Issued 2 October 1991
Resolved
REPLACE PVC PIPE WITH STEEL PIPE USED AS SEA CHEST VENT FOR HIGH SUCTION SEA CHEST MDE COATING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Engineering
Issued 21 November 1990
Resolved
REPACK NEW YORK END SHAFT SO LEAKAGE IS TO ACCEPTABLE LEVEL.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Electrical
Issued 21 November 1990
Resolved
RENEW BLOWER SEAL ON #1 GENERATOR.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Fire Fighting
Issued 21 November 1990
Resolved
REPACK SIX PUMP TO STOP EXCESSIVE LEAKAGE.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Engineering
Issued 21 November 1990
Resolved
MAKE #1 AND #2 HEATING BOILERS AVAILABLE FOR INTERNAL EXAMINATION OR 11/4 MAWP HYDRO TEST.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Fire Fighting
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF SPRINKLING SYSTEM AT THE FOLLOWING AREAS: LINES FROM STATEN ISLAND END; PORT, STBD, CENTER (ZONE 1); PORT, STBD AND CENTER (ZONE 2); CENTER (ZONE 3); STBD, CENTER (ZONE 5) AND PORT, STBD (ZONE 6).
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Documentation
Issued 22 August 1990
Resolved
PROVIDE AN OIL RECORD BOOK TO BE ON BOARD VESSEL.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 23 May 1990
Resolved
REPLACE HANDLES ON LUBE OIL ISOLATION VALVES FOR SHUTDOWN SYSTEM.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Fire Fighting
Issued 23 May 1990
Resolved
MAKE PERMANENT REPAIRS TO WASTED FIRE MAIN PIPING ZONE SIX OF CAR DECK SPRINKLER SYSTEM IN WAY OF TEMPORARY PIPE PATCH.,
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Engineering
Issued 26 February 1990
Resolved
PROVIDE DOGGING WRENCH FOR FUEL OIL SHUT-OFFS ON CAR DECK.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Accommodation/Occupational Safety
Issued 26 February 1990
Resolved
MAKE PERMANENT REPAIRS TO VENTILATION SUPPLY DAMPERS IN AFT MOTOR ROOM. FLAPPER ON DAMPERS ARE MISSING.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Construction/Loadline
Issued 26 February 1990
Resolved
REPLACE NON-SKID DECK COVERING ON WEATHER DECK ON 01 LEVEL.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Fire Fighting
Issued 23 January 1990
Resolved
PROPERLY LABEL AND PROVIDE GUARDS/GLOBES FOR AND OPERATE ALL EMERGENCY LIGHTS TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Engineering
Issued 19 April 1989
Resolved
REPLACE ELECTRICAL WIRING SPLICES FROM PILOT HOUSE TO GENERATOR CONTROL FOR#3 AND #1 M.D.E.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Engineering
Issued 19 April 1989
Resolved
REPLACE GEN. LUBE OIL SENSOR CUT OUT LINE TO GOVEROR #3 MAIN ENGINE, WITH PROPER LINE AND FITTING.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Fire Fighting
Issued 19 April 1989
Resolved
REPAIR OPENING DEVICE TO THE DEVICES FOR THE TWO WIRING PANELS IN THE OFFICE LOUNGE.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Accommodation/Occupational Safety
Issued 19 April 1989
Resolved
REPAIR AND CLOSE UP THE HOT WATER HEATER IN THE SNACK BAR.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Accommodation/Occupational Safety
Issued 19 April 1989
Resolved
REPAIR LEAKING PACKING GLAND ON ENGINE ROOM SEWAGE PUMP.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Engineering
Issued 19 April 1989
Resolved
REPAIR LEAKING FLANGE FOR LUBE OIL COOLER ON THE RETURN SIDE TO #9 M.D.E.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Electrical
Issued 19 April 1989
Resolved
INSTALL MISSING COVER CAPS FOR ENG. RM. HEATER, AFT, PORT AND STBD. (ELEC- TRICAL CONTROL BOX) ELECTRICAL CONTROL BOX ON BOTH THE PORT AND STBD SIDES.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Electrical
Issued 19 April 1989
Resolved
REMOVE ALL LOOSE GEAR OUT FROM BEHIND THE MAIN CONTROL ROOM ELECTRICAL SWITCH BOARD.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Accommodation/Occupational Safety
Issued 19 April 1989
Resolved
REPAIR LELAKING #2 STAGE M.S.D. SEWAGE TANK. LEAK IS FROM AROUND MAN HOLE COVER, FOUR BOLTS MISSING RUSTED THREADS.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Fire Fighting
Issued 19 April 1989
Resolved
PATCH HOLES WITH HEAVY METAL OR OTHER SUITABLE MEANS IN FIRE SCREEN DOORS 5 AND 6.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Fire Fighting
Issued 25 January 1989
Resolved
REPAIR ADJUST OR REPLACE PRESSURE RELIEF VALVE TO EMERGENCY FIRE PUMP AND PROVE PROPER OPERATION IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Engineering
Issued 19 July 1988
Resolved
REPAIR OR RELACE CRACKED EXPANSION JOINT ON NO.1 MAIN EXHAUST.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Engineering
Issued 19 July 1988
Resolved
REPLACE INSULATION ON NO.1 MAIN ENGINE EXHAUST.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Fire Fighting
Issued 14 June 1988
Resolved
REMOVE SOFT PATCH ON FIRE MAIN SYSTEM IN THE ENGINE ROOM AND MAKE PERMANENTREPAIRS.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Engineering
Issued 14 June 1988
Resolved
RECOVER ASBESTOS LAGGING WHERE DAMAGED, IN THE NYC END STEERING GEAR ROOM, BOILER ROOM, AND VENTILATOR FAN ROOM.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Lifesaving
Issued 14 June 1988
Resolved
PROVIDE PFD BREAKOUT HOOKS WHERE MARKED ON LOCATIONS WHERE PFD'S ARE STOWEDOVERHEAD.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Navigation
Issued 14 June 1988
Resolved
PROVIDE PROPER APPROVED NAVIGATION LIGHTS.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Fire Fighting
Issued 14 June 1988
Resolved
REPACK EMERGENCY FIRE PUMP.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Fire Fighting
Issued 14 June 1988
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP RELIEF VALVE.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Fire Fighting
Issued 14 June 1988
Resolved
REPLACE OR REPAIR HOSE NOZZLES AT FIRE STATION NUMBER 1,6, AND 18.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Fire Fighting
Issued 14 June 1988
Resolved
REPAIR FIRE AXE BRAKETS AT F.S. #1 AND #6.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Lifesaving
Issued 14 June 1988
Resolved
ON THE LIFEFLOAT, LOCATED AT NYC END STBD SIDE, REPAIR LIFELINE RING ATTACHMENT AND REPLACE 2 BROKEN PADDLES.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Lifesaving
Issued 14 June 1988
Resolved
PROVIDE AN EFFICIENT NUMBER OF PFD DONNING INSTRUCTIONS WHEREVER PFD'S ARE STOWED. A MINIMUM OF 12 INSTRUCTIONS PER DECK SHALL SATISFY THIS ITEM.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Accommodation/Occupational Safety
Issued 3 December 1987
Resolved
REPAIR FRACTURES IN WATER TANK AT THE NEW YORK END IN WAY OF SADDLES SUPPORTING THE TANK.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Construction/Loadline
Issued 3 December 1987
Resolved
PROVIDE A GUAGING REPORT.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Construction/Loadline
Issued 3 December 1987
Resolved
CLEAN THE RUBBISH FROM THE BILGE IN THE AREA OF THE CREWS LOCKER ROOM.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Fire Fighting
Issued 16 June 1987
Resolved
RENEW SHAFT PACKING ON MAIN FIRE PUMP.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Accommodation/Occupational Safety
Issued 16 June 1987
Resolved
MAKE PERMANENT REPAIRS TO THE AIR DIFFUSER PIPING ON TOP OF THE MSD TANKS TO BE COMPLETED PRIOR TO 1 JULY 1987.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Engineering
Issued 16 June 1987
Resolved
PROVE PROPER OPERATION OF LOW LUBE ALARMS ON #1 AND #2 MAIN PROPULSION GENERATOR PRIME MOVERS.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Fire Fighting
Issued 16 June 1987
Resolved
PROVE PROPER OPERATION OF VEHICLE DECK SPRINKLER SYSTEM TO BE COMPLETED WITHIN 24 HOURS. OPERATION SHALL BE TO THE SATISFACTION OF A USCG INSPEC- TOR.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Navigation
Issued 23 March 1987
Resolved
MAKE PROPER REPAIRS AND PROVE PROPER OPERATION OF PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 23 March 1987
Resolved 23 March 1987
Lifesaving
Issued 23 March 1987
Resolved
PROPERLY SECURE SEA PAINTERS FROM LIFE FLOATS TO DECK.
Condition: Unknown
Due 23 March 1987
Resolved 23 March 1987
Engineering
Issued 23 March 1987
Resolved
PROVE PROPER OPERATION OF NUMBER ONE BOILER.
Condition: Unknown
Due 23 March 1987
Resolved 23 March 1987
Engineering
Issued 23 February 1987
Resolved
REPLACE COVERS ON STOCK SWITCHES ON BOTH BOILERS.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Engineering
Issued 23 February 1987
Resolved
INSTALL COVERS ON BOTH BOILER CONTROLLERS BOXES ON BOTH BOILERS TO ENABLE PROPER OPERATION OF BOIERS AND ALL RESETS WITH THE DOOR CLOSED.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Engineering
Issued 23 February 1987
Resolved
REMOVE ALL WIRE NUTS IN BOILER BOX ON BOTH BOILERS.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Engineering
Issued 31 July 1985
Resolved
PROVIDE #1 & #2 BOILER MOUNTINGS OPENED FOR EXAMINATION AT THE NEXT DRY- DOCKING, BUT NOT LATER THAN 30 NOV 85 TO SATISFACTION OF ATTENDING MARINE INSPECTOR. #1 & #2 BOILER WILL NOT BE USED UNTIL MOUNTINGS ARE EXAMINED.
Condition: Unknown
Due 31 July 1985
Resolved 31 July 1985
Fire Fighting
Issued 16 October 1984
Resolved
CONDUCT PROPER FIRE DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Navigation
Issued 16 October 1984
Resolved
PROVE PROPER OPERATION OF BOTH PILOTHOUSE RADARS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Lifesaving
Issued 16 October 1984
Resolved
CONDUCT PROPER BOAT DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984