BELLE

BELLE is a 1965 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1985, most recently in November 2025, along with 93 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 6 November 2025.

Built
1965
Last inspected
6 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF9417
Flag
UNITED STATES
367504940
Maury page id
psix-44954

Inspections, by type

…with no type recorded7
Years with a record 36 calendar years (1985–2025)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.2 ft × 14.5 ft × 5.8 ft
Registered tonnagegross 21 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBEAL, BUNKER &MACALLISTER · CRANBERRY ISLE, ME, UNITED STATES · built 1965
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF9417MMSI 367504940 · active · compulsorily equipped · granted 15 September 2021, expires 27 September 2031
WCZ9004MMSI not assigned · expired · compulsorily equipped · granted 21 June 2000, cancelled 21 August 2010 · licensed under a name not among this hull’s recorded names (not shown)
WV8361MMSI not assigned · expired · compulsorily equipped · granted 7 December 1998, cancelled 25 April 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 72

6 November 2025 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8260389
12 August 2025 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8205507
24 October 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8000495
8 November 2023 Deficiency Check · Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7805861
26 October 2022 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7575875
16 November 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7348017
13 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7294241
12 August 2020 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7025654
9 April 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6937350
25 October 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841787
19 August 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6787755
12 August 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6783006
12 September 2018 Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6538616
10 May 2018 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6414983
19 October 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6291100
2 August 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6228380
1 August 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5959425
20 October 2015 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5746544
1 September 2011 Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4132170
28 July 2011 Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4098252
27 July 2009 Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3547346
21 May 2008 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3218848
29 January 2008 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3138439
3 August 2006 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2738737
3 April 2006 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2615609
7 June 2005 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2382949
15 July 2004 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2134514
14 May 2004 Examination of Repairs
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2070697
2 July 2003 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1833363
18 June 2003 Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1820632
15 November 2002 Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1705971
11 June 2002 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1630022
12 June 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1428039
10 April 2001 Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1403340
2 January 2001 Drydock Extension
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1057670
22 June 2000 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1467681
11 April 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1445608
29 April 1999 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1128983
30 March 1999 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1117759
2 November 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 805910
27 April 1998 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1123772
9 March 1998 Type not recorded
No type recorded · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 646472
6 May 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1096175
11 April 1997 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1097742
29 April 1996 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1083263
5 March 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 886214
18 November 1995 Type not recorded
No type recorded · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 646473
27 April 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1174987
6 April 1995 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 861456
26 January 1995 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1135127
26 April 1994 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169272
14 July 1993 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 846796
27 April 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1145554
27 April 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 961142
27 April 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1258318
31 March 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268124
9 May 1991 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 923823
7 May 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1231387
30 April 1991 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1223138
14 February 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1225482
24 April 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 906011
1 February 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1235487
18 January 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1234839
27 April 1989 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1042076
31 October 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 890131
20 April 1988 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1198786
27 October 1987 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1017559
22 April 1987 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1012489
19 November 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1023248
23 April 1986 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1307378
26 March 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 997360
13 May 1985 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 979991

Deficiency record · 93

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 August 2025 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air in to the space protected. Vessel did not have appropriate means to plug or cover ventilation ducts for machinery space. Rectify deficiency within 14 days of today's date, 26Aug2025. 46 CFR 181.20-35.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 5 September 2025
Resolution: Operator procured necessary plugs for ventilation ducts.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 12 August 2025 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel did not have stability letter on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 12 August 2025
Resolution: Operator sent email stating stability letter is now on board the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 August 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels safety radio installation certificate was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 9 September 2025
Resolution: Safety install certificate on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2025 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly extinguisher inspections not being conducted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 8 September 2025
Resolution: Operator instructed to commence monthly inspections on portable fire extinguishers.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 October 2024 Resolved
A vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. COI was not original. Provide original COI so it can be endorsed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 13 November 2024
Resolution: Received and endorsed orginal COI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 October 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following:(1) Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition. Replace extinguisher next to operating station. Extinguisher under charged and in unsatisfactory condition. Mounting bracket for extinguisher also in need of replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 13 November 2024
Resolution: Operator sent photo attesting to the replacement of the extinguisher and bracket.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 October 2024 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Repair deck rail at port aft corner to the satisfaction of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 13 November 2024
Resolution: Received photos of repaired railing.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 October 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following:(1) Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition. Replace pull ring for manual discharge release for fixed extinguishing system (Fire Boy). Ring is rusted in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 13 November 2024
Resolution: Received photo of new pull ring for manual release of the FireBoy.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 8 November 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI observed aft bilge alarm failed to activate upon flooding of the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 20 November 2023
Resolution: MI observed a successful test of the high water alarm in the aft compartment.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 November 2023 Resolved
A power-driven vessel underway shall exhibit: (i) A masthead light forward. MI observed masthead light inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 20 November 2023
Resolution: MI observed operation of the masthead light.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 November 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables. MI observed that all charts and publications were out of date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 20 November 2023
Resolution: MI observed up to date charts and publications on the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 November 2023 Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees. MI observed that the vessel's MMSI number was not programmed into the DSC radio. 47 CFR 80.103(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 20 November 2023
Resolution: MI observed the MMSI number programmed into the DSC radio.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2023 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. MI observed that no records of maintence for the fire protection systems was available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 15 November 2023
Resolution: Operator provided objective evidence in the form of a receipt attesting to the annual maintenance being completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2023 Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. MI observed that the vessel name and hailing port were not marked on the stern of the vessel. Deficiency to be corrected prior to next credit Hull Inspection.
Action required: 705 - Other - as specified
Resolved 28 December 2023
Resolution: MI observed vessel name and hailing poprt on stern of vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2021 Resolved
Shutoff valves, must be fitted in the fuel supply lines and must be manually operable from outside the compartment in which the valve is located. The shutoff for the forward most fuel tank was inoperable. Repair affected shutoff and test in presence of marine inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2021
Resolved 15 October 2021
Resolution: Verified proper operation of remote fuel shutoff for the forward fuel tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2021 Resolved
All fuel tanks shall be electrically bonded to the common ground. The vessel's fill pipe for the forward most fuel tank has a flexible piping in between two sections of steel pipe and no means of grounding the tank was available. Vessel to adequately ground tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2021
Resolved 15 October 2021
Resolution: Verified grounding wire was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2021 Resolved
Connections must be made to battery terminals with permanent type connectors. Vessel has twist-on connectors on both battery terminals. Vessel to replace temporary connectors with permanent type connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2021
Resolved 15 October 2021
Resolution: Verified permanent connectors on battery terminals.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 12 August 2020 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels Are specifically assigned the duties of warning, mustering, assembling, assisting, or controlling the movement of passengers during emergencies. No proof of employee enrollment in chemical testing program was available. Provide proof of employee enrollment
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2020
Resolution: Vessel rep provided updated list of employees from testing agency.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 12 August 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Starboard F/O tank supply remote valve operator would not close required valve. Make repairs to system to allow for remote closing of starboard shutoff valve
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2020
Resolution: Fuel pull stop repaird. Test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2020 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Essex’s shaft seal leaking constant flow of water into vessels bilge. Make repairs to vessel shaft seal to prevent leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2020
Resolved 13 August 2020
Resolution: Vessel shaft seal packing adjusted. All sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 August 2020 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. No drills logged. Conducted drills during inspection and properly logged them.
Action required: 10 - Deficiency Rectified
Due 12 August 2020
Resolved 12 August 2020
Resolution: Conducted Fire and MOB drill during exam. Vessel rep properly logged drills. Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 April 2020 Resolved
YOUR VESSEL MUST COMPLETE AN INSPECTION FOR RENEWAL OF A COI. THE VESSEL IS GRANTED A 90-DAY EXTENSION FOR ITS COI RENEWAL INSPECTION, TO BE COMPLETED NO LATER THAN 13AUG2020.
Action required: 705 - Other - as specified
Due 13 August 2020
Resolved 12 August 2020
Resolution: Completed satisfactory COI inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 December 2019 Resolved
When required by the marine inspector, a portion of the inspection must be conducted while the vessel is underway so that the hull and internal structure can be observed. Conduct underway sea-trials to satisfaction of attending Marine Inspector prior to carrying passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 April 2020
Resolved 12 August 2020
Resolution: Completed satisfactory underway trial.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 August 2019 Resolved
The condition of the hull's structure shall be satisfactory to the marine inspector. The vessel has a cracked frame on port side in forepeak. Submit proposal to OCMI for repair. Repairs not to be completed until proposal approved by [name withheld] must be rectified including completion of approved repairs no later than December 31, 2019. 46CFR176.25-5(a)(1)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 19 November 2019
Resolution: Cracked frame was reinforced and inspected during 2019 credit hull exam. See activity 6841787 for details.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 August 2019 Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. The vessel has electrical wiring penetrating the watertight bulkhead in the forepeak preventing the space from being watertight. 46CFR171.114(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 5 September 2019
Resolution: Bulkhead was sealed with epoxy.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 19 August 2019 Resolved
Man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel's ship log is not available for inspection and unable to provide documentation of fire and man overboard drills.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 5 September 2019
Resolution: Captain provided logbook with drills and trainings logged.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 August 2019 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of its crew. Not all of the vessel's crew are enrolled in the chemical testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 5 September 2019
Resolution: Captain provided updated crew list
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2019 Resolved
The vessel's sole ringbuoy is required to be fitted with a lifeline. The vessel's ringbuoy lifeline is not attached to the ringbuoy.
Action required: 10 - Deficiency Rectified
Due 19 August 2019
Resolved 19 August 2019
Resolution: Ringbuoy lifeline was attached to the ringbuoy on the spot.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 September 2018 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Aft engine room bulkhead is not watertight. 46CFR171.114(a)(2).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2018
Resolved 2 October 2018
Resolution: Aft engine room bulkhead made watertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 September 2018 Resolved
Each hatch exposed to the weather must be watertight. Forward deck hatch is not watertight (securing device missing) 46CFR171.124(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 2 October 2018
Resolution: Forward deck hatch made watertight.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 12 September 2018 Resolved
...it shall be the duty of the master of any vessel...to prepare and post emergency checkoff lists in a conspicuous place accessible to crew and passengers. Master does not have emergency instructions for vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2018
Resolved 2 October 2018
Resolution: Emergency instructions posted.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 12 September 2018 Resolved
Each vessel...must have a detailed inspection of the radio installation by an FCC-licensed technician IAW 47CFR80.59 once every five years. Vessel's FCC Safety Radiotelephony Certificate is expired. 47CFR80.903
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2018
Resolved 2 October 2018
Resolution: FCC Safety Radiotelephony Certificate renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2018 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Pre-employment testing for employee on the drug testing program not completed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2018
Resolved 2 October 2018
Resolution: Pre-employment testing completed.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 September 2018 Resolved
...the stability letter must be posted under glass or other suitable transparent material. Stability letter not posted on/available for, vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2018
Resolved 2 October 2018
Resolution: Stability letter posted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 September 2018 Resolved
For items not cover by standards in this subchapter, inspection shall be IAW standards acceptable to the OCMI, as good marine practice. Rub rails on port and stbd side are wasted.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 13 November 2018
Resolution: Rub rails on port and starboard side replaced.
Construction/Loadline › Hull › Hull Plating
Issued 6 December 2017 Resolved
Vsl required to complete satisfactory in water portion of hull exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2018
Construction/Loadline › Hull › Transverse Frame
Issued 6 December 2017 Resolved
Frames 3 and 7 from stern on stbd side are cracked. Repair/renew.
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 November 2018
Resolution: Frames 3 and 7 from stern on stbd side were sistered with laminated white oak, all sat.
Construction/Loadline › Hull › Transverse Frame
Issued 6 December 2017 Resolved
Frame 2 aft of forward engine room bulkhead on port and stbd side is cracked IWO floor timber. Repair/renew.
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 November 2018
Resolution: Frame 2 aft of fwd ER bulkhead port and starboard sistered with single 2x2 white oak timber.
Construction/Loadline › Hull › Transverse Frame
Issued 6 December 2017 Resolved
Frame 5 forward of aft engine room bulkhead found rotten port side. Crop and renew.
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 November 2018
Resolution: Frame 5 fwd of aft ER bulkhead port side repaired/reinforced using stainless steel strap fastened with silicon bronze screws.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 August 2017 Resolved
Provide proof of enrollment in drug program 46CFR16 by 14AUG17.
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 18 August 2017
Resolution: Proof of drug program enrollment provided with current staffed crew.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 August 2017 Resolved
provide valid FCC station license by 14AUG17, 46CFR80.
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 18 August 2017
Resolution: FCC Station License was provided.
Lifesaving › Hand Flares › Storage
Issued 2 August 2017 Resolved
Have onboard watertight container for distress signals with markings by 14AUG17, 46CFR185.614.
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 18 August 2017
Resolution: New water tight container for flares onboard and marked.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 August 2017 Resolved
Have onboard in first aid kit aspirin, 46CFR160.041 by 14AUG17.
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 18 August 2017
Resolution: New aspirin provided for first aid kit.
Lifesaving › Lifejacket/PFD (Type III) › Marking
Issued 2 August 2017 Resolved
Properly number life jacket quantity IAW 46CFR180.78 by 14AUG17.
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 18 August 2017
Resolution: Life jacket stowage numbered and marked correctly.
Communications › Alarms/Indicators › High Water Alarm
Issued 2 August 2017 Resolved
Repair hi water alarm for forward compartment, 46CFR182.530, corrected on the spot.
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 2 August 2017
Resolution: corrected on the spot.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 August 2017 Resolved
Have barratries stowed in proper box by 14AUG17, 46CFR183.350.
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 18 August 2017
Resolution: Onboard ships batteries secured and stowed properly.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 1 August 2016 Resolved
Provide 2 flashlights 46CFR183.430 corrected on the spot.
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Provide 2 flashlights 46CFR183.430 corrected on the spot.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 August 2016 Resolved
Provide radio broadcast placard 46CFR184.506, corrected on the spot.
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Provide radio broadcast placard 46CFR184.506, corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 August 2016 Resolved
Repair stern light 46CFR183.420 corrected on the spot.
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Repair stern light 46CFR183.420 corrected on the spot.
Fire Fighting › Fire Bucket › Lanyard
Issued 1 August 2016 Resolved
provide lines for all fire buckets 46CFR181.610 corrected on the spot.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 1 August 2016
Stability › Weathertight Integrity › General
Issued 1 August 2016 Resolved
Provide lanyard for steering compartment hatch by 15AUG16 46CFR179.360.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 5 August 2016
Resolution: new chain installed
Engineering › Bilge Water Management System › Pump
Issued 1 August 2016 Resolved
Make operational electric bilge pump in forward compartment by 5AUG16 46CFR182.520.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 August 2016
Resolution: new bilge pump installed
Communications › Radio Communications › VHF Radiotelephone
Issued 1 August 2016 Resolved
provide valid radio safety certificate by 15AUG16 47CFR13.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 5 August 2016
Resolution: MA found radio lic.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 August 2016 Resolved
Have a valid drug testing program by 15AUG16 46CFR16
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 26 August 2016
Resolution: RCV E-mail from company rep proff of enrollment in DOT Drug Program and passing inital drug testing for Operator and Crew Member. Cleared repaining 835 for drug program.
Communications › Radio Communications › EPIRB
Issued 9 September 2011 Resolved
EPRIB registration has expired. Provide updated registration. Vessel shall not exceed 3 miles from shore.
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 13 September 2011
Resolution: Vessels rep provide a proper EPRIB registration.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 September 2011 Resolved
Prove proper operation of the fore peak bilge alarm.
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 13 September 2011
Resolution: Tested the fore peak bilge alarm, test sat.
Construction/Loadline › Structures › Scuttle
Issued 9 September 2011 Resolved
Repair the hinge on the cabin escape scuttle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 13 September 2011
Resolution: Inspected the new hinge installation, all sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 September 2011 Resolved
Prove proper operation of the engine automatic shut down with the install engine room fire suppression system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 13 September 2011
Resolution: Tested the automatic shut down of the main engine.
Lifesaving › Lifefloat › Paddle
Issued 28 July 2011 Resolved
Replace all eight lifefloat paddles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 13 September 2011
Resolution: All lifefloat paddles have been replaced with new.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 October 2009 Resolved
Fixed CO2 fire extinguishing system failed to shut down the engine when tested. Need to make repairs and demonstrate sat operational test.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 September 2011
Resolution: Tested the automatic engine shut down with the fire suppression system, test sat.
Documentation › Certificates/Documents › Stability Letter
Issued 14 October 2009 Resolved
Missing Stabillity Letter. Need to locate stability letter or conduct stability test
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2011
Resolution: Gave the vessels operator the stability letter. The test was conducted on 1 Sept 2011.
Engineering › Fuel Oil Service System › Valve
Issued 14 October 2009 Resolved
All three remote fuel shut-off valves are seized. and need to be repaired and maintained.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 September 2011
Resolution: Tested all three remote fuel shut offs, test sat.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 14 October 2009 Resolved
there is no way to secure air intake to engine compartment in the event of a fier. Need to make provitions for allowing the securing of the engine compartment air intakes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 July 2011
Resolution: Not required as per 46 CFR 181.420. Pre-engineered fixed gas fire extinguishing systems are required to shut down Power ventilation. This vessel has natural ventilation, therefore this requirement does not apply.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 14 October 2009 Resolved
one buoyant apparatus waterlight is inop. Nedd to repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 September 2011
Resolution: Test all waterlights, all tested sat.
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 14 October 2009 Resolved
Missing one of the required lifejackets. need to get one more lifejacket.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2011
Resolution: The vessel now has the required amount of lifejackets as per the COI.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 October 2009 Resolved
COD is expiered. Need to renew COD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 July 2011
Resolution: Verified the vessel''s new Certificate of Documentation that was issued July 12, 2011. A copy was placed in the vessel''s hard file.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 October 2009 Resolved
No proof of enrolment in drug and alcohol testing program. Need to comply with drug and alcohol tasting requirements.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2011
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 October 2009 Resolved
Expired battery on EPIRB. Need to install new battery and demonstrate operational test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 September 2011
Resolution: The EPIRB battery has been replaced. Replacement date is 2014. Tested the EPIRB, test sat.
Construction/Loadline › Hull › Transverse Frame
Issued 21 May 2008 Resolved
Broken frame on port side in compartment fwd of pilot station.
Action required: 705 - Other - as specified
Due 22 July 2008
Resolved 22 July 2008
Resolution: Frame repaired as required
Construction/Loadline › Hull › Hull Plating
Issued 21 May 2008 Resolved
Excessive wastage identified in transverse frames, butt blocks, and planks in the engine room in way of the engine, and under fuel tanks and battery rack.
Action required: 705 - Other - as specified
Due 22 July 2008
Resolved 22 July 2008
Resolution: All items identified repaired or renewed
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 May 2008 Resolved
Change name on vsl from middelbank to belle as per vsl doc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2008
Resolved 28 July 2011
Resolution: Name has been changed on the vessel to reflect BELLE as per vessel''s COD
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 May 2008 Resolved
Get u/w with attending marine inspector to complete credit hull exam
Action required: 705 - Other - as specified
Due 22 July 2008
Resolved 9 September 2011
Stability › Incline Test › General
Issued 29 January 2008 Resolved
Vessel required to complete simplified stability test prior to next drydock.
Action required: 705 - Other - as specified
Resolved 1 September 2011
Resolution: Wittnessed a satisfactory simplified stability test. Test completed at 185 lbs per person. Max persons allowed on board is 51.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 3 August 2006 Resolved
Waterlight on bouyant apparatus inoperable.
Condition: Improper/Lack of Maintenance
Due 3 August 2006
Resolved 3 August 2006
Resolution: O/O ordered new waterlight in presence of attending marine inspectors.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 3 August 2006 Resolved
Emergency radio broadcast placard missing from radio station.
Condition: Improper/Lack of Maintenance
Due 3 August 2006
Resolved 3 August 2006
Resolution: Emergency radio broadcast placard posted.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 15 July 2004 Resolved
Provide current FCC Safety Radio Certificate.
Condition: Unknown
Due 29 August 2004
Resolved 12 August 2004
Resolution: sighted new cert
Construction/Loadline
Issued 10 April 2001 Resolved
sister 5th frame from transome.
Condition: Unknown
Due 10 June 2001
Resolved 15 June 2001
Construction/Loadline
Issued 10 April 2001 Resolved
Sister 6th frame from transome port side.
Condition: Unknown
Due 10 June 2001
Resolved 15 June 2001
Accommodation/Occupational Safety
Issued 22 June 2000 Resolved
PROVIDE COPY OF CFR'S FOR THE VESSEL.
Condition: Unknown
Due 22 July 2000
Resolved 27 July 2000
Lifesaving
Issued 22 June 2000 Resolved
PROVIDE MEANS FOR PASSENGER COUNT.
Condition: Unknown
Due 22 June 2000
Resolved 27 July 2000
Documentation
Issued 22 June 2000 Resolved
PROVIDE COPIES OF DAPI CONTRACT AND MRO.
Condition: Unknown
Due 22 June 2000
Resolved 27 July 2000
Lifesaving
Issued 22 June 2000 Resolved
PROVIDE DONNING INSTRUCTIONS FOR ALL TYPES OF LIFE JACKETS ON BOARD.
Condition: Unknown
Due 22 June 2000
Resolved 27 July 2000
Construction/Loadline
Issued 2 November 1998 Resolved
MAKE VESSEL AVAILABLE FOR EXAMINATION UNDERWAY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Engineering
Issued 27 April 1998 Resolved
MOVE EMERGENCY FUEL SHUT OFFS TO EXTERNAL OF ENGINE BOX.
Condition: Unknown
Due 27 April 1998
Resolved 29 April 1998
Lifesaving
Issued 27 April 1995 Resolved
REMOVE FROM VESSEL TWO ADULT PFD'S ROTTED AND TORN.
Condition: Unknown
Due 27 April 1995
Resolved 28 April 1995
Construction/Loadline
Issued 6 April 1995 Resolved
MAKE THE FRAMES ON THE PORT SIDE (#'S 4 & 5) IN LAZARETTE FROM FORWARD BULKHEAD, AVAILABLE FOR FURTHER INSPECTION AND EVALUATION FOR REPAIRS.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Construction/Loadline
Issued 6 April 1995 Resolved
REEF OUT ROT NOTED ON EDGES OF FRAMES 3,6,9, AND 10 ON THE STARBOARD SIDE OF THE LAZARETTE.
Condition: Unknown
Due 27 April 1995
Resolved 28 April 1995
Navigation
Issued 26 April 1994 Resolved
RENEW FASTENERS TO STEERING GEAR BRACKET WHERE LOOSE.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Lifesaving
Issued 26 April 1994 Resolved
REPLACED 3 ADULT PFD'S THIS EXAMINATION
Condition: Unknown
Due 26 April 1994
Resolved 4 May 1994
Navigation
Issued 26 April 1994 Resolved
OBTAINED CURRENT LOCAL NAVIGATIONAL CHARTS AND PUBLICATIONS
Condition: Unknown
Due 26 April 1994
Resolved 4 May 1994
Lifesaving
Issued 30 April 1991 Resolved
ENSURE REPAIRS MADE TO VESSEL'S BOUYANT APPARATUS ARE DONE IN ACCORDANCE WITH 46 CFR 160.010 AND APPLICABLE SECTION OF NAVIC 2-63 (ENCLOSED) AND MAKE BOUYANT APPARATUS AVALABLE FOR INSPECTON BY CG INSPECTOR. UNTIL SUCH TIME VESSEL IS NOT TO OPERATE BEYOND 1 MILE FROM LAND WITH PASSENGERS.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Construction/Loadline
Issued 18 January 1990 Resolved
FOURTH FRAME FORWARD OF TRANSOM STARBOARD SIDE CRACKED. MAKED PERMANENT REPAIR TO CRACKED FRAME.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Engineering
Issued 27 April 1989 Resolved
RACOR FUEL FILTER MISSING HEAT SHIELD AND METAL BOWL DRAIN PLUG. PROVIDE HEAT SHIELD AND DRAIN PLUG FOR FILTER ASSEMBLY.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.