MAURY USCG vessel records Sign in
← All vessels

PELICAN

PELICAN is a 1996 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1996, most recently in October 2025, along with 55 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 1996 to 2025. Most recent: inspection, 8 October 2025.

Built
1996
Last inspected
8 October 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDD8636
449655
Flag
UNITED STATES
—
Maury page id
psix-449655

Inspections, by type

Years with a record 26 calendar years (1996–2025)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

8 October 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8219976
11 September 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7897562
4 October 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7786976
12 July 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7467472
28 June 2022 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7467469
4 March 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7406163
22 December 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7115415
23 May 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618369
16 May 2019 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618364
21 May 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384228
29 June 2017 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6168829
3 May 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6117873
20 September 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6002505
9 October 2015 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5739645
2 October 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4991994
9 July 2012 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4313507
30 July 2009 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3548679
11 May 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3470375
20 February 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3421078
10 June 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3202793
5 June 2007 COI Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952611
6 September 2006 Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2765842
22 June 2006 Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2704494
5 October 2005 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2509692
22 February 2005 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2296647
19 October 2004 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2223843
21 September 2004 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2200805
10 August 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2161626
2 July 2003 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1833264
24 February 2003 Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1748834
2 April 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1600554
11 March 2002 Re-Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1493068
23 April 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1062666
12 March 2001 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1418873
7 February 2000 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1378995
15 March 1999 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1463440
3 March 1998 Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421519
27 February 1997 Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1442560
13 November 1996 Initial Construction-Excluding Oversight
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1173952

Deficiency record · 55

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 October 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation rules. Vessels navigation light were inoperable. Make navigation lights fully operational and available for inspection by the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 17 October 2025
Resolution: Recieved images with satisfactory operation of navigation lights. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 October 2023 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.50 in sub-chapter Q of this chapter, or other standard specidied by the Commandant. MI observed ring life buoy line deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 20 October 2023
Resolution: Vessel sent pictures of replacement life ring.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2022 Resolved
A vessel must 2.5 gallons, with an attached lanyard. The words "FIRE BUCKET" must be stenciled in contrasting color on each bucket. Vessel had two deteriorated fire buckets iwth no stenciling on the side. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 13 October 2022
Resolution: Vessel provided satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2022 Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to saltwater, heat and vibration, may be used. Vessel fuel fill pipe and vent hose have begun to deteriorate. 46 CFR 182.445(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 26 July 2022
Resolution: Vessel sent in picture showing proof of flexible hose replacement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 December 2020 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval on 30SEP2020. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2020
Resolved 20 January 2023
Resolution: Vessel Completed Renewal COI.
Engineering › Bilge Water Management System › Pump
Issued 14 October 2015 Resolved
Vessel does not have required bilge hand pump
Action required: 705 - Other - as specified
Resolved 14 October 2015
Resolution: Provided hand pump from another vessel until a permanent pump can be purchased.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 October 2015 Resolved
Vessel was unable to provide portable Fire FIghting Servicing Certificates
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2015
Resolution: Vessel had all portable fire extinguishers serviced, all satisfactory.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 14 October 2015 Resolved
Abandon ship drills and fire drills not logged or conducted in time frame required.
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 23 October 2015
Resolution: Vessel provided log book and documentation of most recent fire and abandon ship drills.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 October 2015 Resolved
Life ring buoy needs retro-reflective tape and 60ft life line.
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 23 October 2015
Resolution: Retro reflective tape was added to ring buoy and proper line installed
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 October 2015 Resolved
Dead end wire found under console must be removed or terminated
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 23 October 2015
Resolution: Dead end wires were properly terminated.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 October 2015 Resolved
Live wire overhead of the console needs to be terminated properly
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 23 October 2015
Resolution: Wire terminated properly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 October 2015 Resolved
First aid kit insufficient not Coast Guard approved.
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 23 October 2015
Resolution: Vessel has water tight properly labeled CG approved medical kit.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 October 2015 Resolved
9 child lifejackets need to be stenciled with vessel name
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 23 October 2015
Resolution: Child life jackets properly marked.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 October 2015 Resolved
Complete a satisfactory USCG annual inspection, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2015
Resolution: Vessel completed an annual CG inspection, all satisfactory.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 October 2014 Resolved
Provide proper charts, tide/current tables, and light list.
Due 1 November 2014
Resolved 23 October 2014
Resolution: Vsl acquired accurate light list printouts, chart booklet, and tide/current tables.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 October 2014 Resolved
Provide proper alcohol test strips.
Due 1 November 2014
Resolved 23 October 2014
Resolution: Vsl rep purchased acceptable alcohol test strips.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 9 July 2012 Resolved
Provide proof of current registration IAW 46CFR176.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 13 August 2012
Resolution: Provided proof of current registration.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 9 July 2012 Resolved
Label quantity of children for life jackets IAW 46CFR180.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 13 August 2012
Resolution: Labeled stowage of life jackets properly.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 9 July 2012 Resolved
Provide label for adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 13 August 2012
Resolution: Labeled stowage of life jackets properly.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 9 July 2012 Resolved
Provide battery box IAW 46CFR183.350
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 13 August 2012
Resolution: Provided battery box.
Construction/Loadline › Penetrations › Gasket
Issued 30 July 2009 Resolved
Pontoon air vent pipe plugs were worn to a point of inoperability and the inability to adequately hold air pressure within all pontoon chambers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2009
Resolved 1 August 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 February 2005 Resolved
PROVIDE AN OPERATIONAL SELF ACTIVATING LIGHT FOR THE RING BOUY..
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2005
Resolved 25 March 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 10 August 2004 Resolved
Comply with 46CFR177.820. (Affix seats to deck)
Action required: 705 - Other - as specified
Due 21 August 2004
Resolved 1 October 2004
Resolution: Received fax notification stating thta passenger seats have been fastened to the floor.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2004 Resolved
Remove dead end wiring from old loud hailer installation.
Action required: 705 - Other - as specified
Due 21 August 2004
Resolved 1 October 2004
Resolution: Received fax notification that above has been corrected.
Construction/Loadline › Hull
Issued 24 February 2003 Resolved
REPAIR ALUMINUM "WEAR" STRIP ON BOTH FWD PONTOONS. LEGACY COMPONENT DESC: Keel
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 14 March 2003
Resolution: Big Al''''s Welding installed wear plate. Air test SAT
Construction/Loadline › Structures
Issued 24 February 2003 Resolved
REPAIR FRACTURES ON ALUMINUM MOTOR MOUNT
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 14 March 2003
Operations/Management › Drug and Alcohol Testing
Issued 24 February 2003 Resolved
PROVIDE MIS REPORT (2002) AND EAP TRAINING MATERIALS LEGACY COMPONENT DESC: MIS Submission
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 14 March 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 February 2003 Resolved
RE-NEW RETROREFLECTIVE TAPE ON PFD'S LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 14 March 2003
Lifesaving › Lifebuoys
Issued 24 February 2003 Resolved
PROVIDE NEW LIFERING AND 60FT OF DARK POLYPROPYLENE LINE
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 14 March 2003
Operations/Management › Drills/Instruction
Issued 24 February 2003 Resolved
CONDUCT FIREFIGHTING DRILLS AND LOG SUCH.
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 14 March 2003
Electrical › Electrical Distribution System (service)
Issued 24 February 2003 Resolved
replace all damaged wiring and cables damaged during welding operations. LEGACY COMPONENT DESC: Wiring
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 14 March 2003
Engineering › Fuel Oil Service System
Issued 24 February 2003 Resolved
Re-mount fuel filter LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 20 March 2003
Resolved 14 March 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 February 2003 Resolved
provide proper size mounting brackets for fire extinguishers LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 20 March 2003
Resolved 14 March 2003
Construction/Loadline › Structures › Superstructure
Issued 24 February 2003 Resolved
Repair port fwd aluminum bulwark.
Action required: 705 - Other - as specified
Due 20 March 2003
Resolved 14 March 2003
Lifesaving › Lifebuoys
Issued 12 March 2002 Resolved
PROVIDE 60FT OF POLYPROPELYNE LINE AND ATTACH TO LIFE RING. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 12 April 2002
Resolved 2 April 2002
Lifesaving › Lifebuoys
Issued 12 March 2002 Resolved
REPAIR/REPLACE FLOATING WATER LIGHT LEGACY COMPONENT DESC: Self-igniting Lights
Due 12 April 2002
Resolved 2 April 2002
Documentation › Certificates/Documents
Issued 12 March 2002 Resolved
Provide FCC station license
Action required: 705 - Other - as specified
Due 11 March 2003
Resolved 12 March 2002
Resolution: This requirement recinded due to vessel not required to maintain a radio station, vessel operates less than 1000 ft from shore.
Lifesaving
Issued 12 March 2001 Resolved
REPLENISH FIRST AID KIT.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Navigation
Issued 12 March 2001 Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Accommodation/Occupational Safety
Issued 12 March 2001 Resolved
ENSURE ALL PASSENGER SEATING IS FIXED OR RECOMPUTE PASSENGER CAPACITY USINGALTERNATIVE METHOD.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Electrical
Issued 12 March 2001 Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Unknown
Issued 12 March 2001 Resolved
MAKE ANNUAL USER FEE PAYMENT AND PROVIDE PROOF.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Documentation
Issued 12 March 2001 Resolved
PROVIDE AND POST STABILITY LETTER.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Documentation
Issued 12 March 2001 Resolved
PROVIDE VESSEL TRAINING LOGBOOK.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Documentation
Issued 12 March 2001 Resolved
PROVIDE PROOF OF CREW ENROLLMENT IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Lifesaving
Issued 12 March 2001 Resolved
MARK PFD'S AND RING BUOY WITH VESSEL'S OFFICIAL NUMBER.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Lifesaving
Issued 12 March 2001 Resolved
INSTALL A DETACHABLE CLIP ON RING BUOY LIGHT.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Unknown
Issued 15 March 1999 Resolved
COMPLY WITH ALL OUTSTANDING ITEMS ON DRUG TESTING AUDIT FORM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1999
Resolved 20 July 1999
Lifesaving
Issued 15 March 1999 Resolved
REPAIR RING BUOY WATERLIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 1999
Resolved 20 July 1999
Lifesaving
Issued 15 March 1999 Resolved
INSTALL RETRO TAPE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 1999
Resolved 20 July 1999
Lifesaving
Issued 3 March 1998 Resolved
LABEL RING BUOY W/VESSEL NAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1998
Resolved 28 May 1998
Fire Fighting
Issued 3 March 1998 Resolved
LABEL FIRE BUCKET AS SUCH._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1998
Resolved 28 May 1998
Unknown
Issued 3 March 1998 Resolved
ENROLL ALL VESSEL EMPLOYEES IN AN APPROVED DRUG TESTING PROGRAM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1998
Resolved 28 May 1998
Documentation
Issued 3 March 1998 Resolved
POST CERTIFICATE OF INSPECTION AND STABILITY LETTER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1998
Resolved 28 May 1998
Lifesaving
Issued 3 March 1998 Resolved
PROVIDE 1 ADDITIONAL ADULT PFD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1998
Resolved 28 May 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.