Records from 2002 to 2023. Most recent: inspection, 16 May 2023.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2021
No resolution recorded
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock and internal structural examination at least once every two years. Vessel has failed to schedule drydock and internal structural examination within two years of last drydock as listed on the COI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 December 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 September 2021
Resolved
The float-free link required by §180.130(a)(1) must be: Certified to meet §160.073 in subchapter Q of this chapter, or other standard specified by the Commandant. The vessel's float-free link is intended for life floats and buoyant apparatus of 11 to 20 persons capacity, however are securing life floats of 42 persons capacity.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2021
Resolution: Float free link replaced to match persons capacity.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 8 September 2021
Resolved
When the flexible section for diesel fuel tanks is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Vessel is missing grounding on starboard fuel fill.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2021
Resolved 14 October 2021
Resolution: Grounding added to fuel fill.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2021
No resolution recorded
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch (PSI) at the pump outlet. Vessel's fire pump gauge was not properly reading the pressure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 September 2021
Resolved
Each survival craft, rescue boat, and launching appliance on a vessel must be inspected monthly, using the manufacturer's instructions to make sure it is complete and in good order. Vessel was not logging monthly primary survival craft maintenance.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 September 2021
Resolution: Conducted EPIRB test.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 July 2021
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not complete annual inspection.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 30 August 2021
Resolved 8 September 2021
Resolution: Completed required annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 February 2020
Resolved
Each generator onboard the vessel must have an independent prime mover and the generator circuit breaker must be interlocked to prevent the generators from being simultaneously connected to the switchboard. Vessel does have not have its generators interlocked as one generator is operating while the other is secured
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 2 July 2020
Resolution: Electricity supply is routed through a 2-switch arrangement. Satisfactorily tested both switches in all positions, with both generators running. Installed as designed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 February 2020
Resolved
Drains and dirt traps shall be fitted for fixed fire extinguishing systems where necessary to prevent the accumulation of dirt or moisture. Drains and dirt traps shall be located in accessible locations. Vessel’s fixed fire extinguishing systems did not contain drains or dirt traps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 30 September 2020
Resolution: Operator sent pictures to MI displaying drains.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 22 April 2019
Resolved
46CFR 176.25-5(a)(1) - Marine inspector is to examine all accessible parts of the exterior and interior of the hull, sections of lining or ceiling may be removed or parts otherwise probed or exposed so the marine inspector may be satisfied as to the condition of the hull. Areas of wood rot noted in frames 3, 4, & 5 of the forepeak at the junction where the frames meet the keelson. Rot also noted at the top two strakes of frames 3 and 4. Vessel to further investigate all signs of rot in the forepeak and repair/replace at next dry dock to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 22 October 2019
Resolution: Inspected areas and determined repairs not neccessary.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 22 April 2019
Resolved
46CFR 176.25-5(a)(1) - Marine inspector is to examine all accessible parts of the exterior and interior of the hull, sections of lining or ceiling may be removed or parts otherwise probed or exposed so the marine inspector may be satisfied as to the condition of the hull. Wood rot noted in stbd side aft gusset of engine room. Vessel to repair at dry dock to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 22 October 2019
Resolution: Inspected area and determined repairs not neccessary.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2019
Resolved
46CFR 183.05-20(a) - Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Battery storage container in engine room did not have a cover, exposing the terminals. Vessel to install cover to properly protect battery terminals.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2019
Resolved 24 May 2019
Resolution: Vessel operator emailed picture of appropriate cover/screen for machinery space batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 April 2019
Resolved
46CFR 180.15-1(b) - Each life float shall be fitted with a life line and shall be equipped with two paddles. Each life float was equipped with only one paddles. Vessel must add necessary amount of paddles to have a pair for each life float.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 10 May 2019
Resolution: Vessel emailed photos of paddle order receipt and of all new paddles marked properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2019
Resolved
46CFR 176.25-20(a) - At each initial and subsequent inspection for certification and reinspection the marine inspector shall inspect all lifesaving equipment to determine its serviceability. Three life preservers deemed unfit for service and require replacement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 April 2019
Resolved 22 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2019
Resolved
46CFR 180.25-10 - Life preservers for children, when provided, shall be stowed separately. Child life preservers found stowed mixed with adult in second deck bench storage. Vessel re-arranged storage to seperate appropriately.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 22 April 2019
Resolved 22 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2019
Resolved
46CFR 180.25-15(a) - All life preservers shall be marked with the vessel's name. One life preserver found with different vessel name stenciled on it. Vessel covered old mark and relabled life preserver with current vessel name.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 April 2019
Resolved 22 April 2019
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 May 2018
Resolved
Electrical box on fwd bulkhead in lazarette not mounted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 24 May 2018
Resolution: Electrical Box mounted to the bulkhead.
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 May 2018
Resolved
Steering system hose chaffing on frame edge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 21 May 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2018
Resolved
Stbd strut bonding wire broken.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 24 May 2018
Resolution: Starboard Strut bonding Wire connected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2018
Resolved
Wire exposed by port shaft.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 24 May 2018
Resolution: Bonding wires reconnected.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 May 2018
Resolved
Galley light cover missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 24 May 2018
Resolution: Galley light cover installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2018
Resolved
Exposed wires found near bar not properly dead ended.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 24 May 2018
Resolution: Wire adjusted and installed into outlet correctly.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 May 2018
Resolved
Emergency escape outside engine room blocked by improper stowage of equipment and supplies.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 21 May 2018
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 May 2018
Resolved
Emergency escape ladder outside engine room not secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 24 May 2018
Resolution: Emergency Escape Hatch Ladder Rungs secured.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 May 2018
Resolved
Lighting outside emergency escape improperly wired.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 24 May 2018
Resolution: Light Rewired properly.
Electrical › Electrical Distribution System (service) › Fuse
Issued 21 May 2018
Resolved
Exposed fuse discovered engine room port side on bulkhead, not located adjacent to power source. Submit repair plans for review.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 22 October 2019
Resolution: Fuse removed
Communications › Radio Communications › EPIRB
Issued 21 May 2018
Resolved
NOAA registration sticker on EPIRB expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 22 August 2018
Resolution: Provided photograph of NOAA registration.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 21 May 2018
Resolved
DSC radio does not have position available. Route restricted to L/B/S. New FCC Safety Certificate required once repaired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 22 August 2018
Resolution: DSC Radio installed and FCC Licences updated.
Construction/Loadline › Hull › Transverse Frame
Issued 21 May 2018
Resolved
Frame 27 rotted above weather deck both port and stbd sides. Repair at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 October 2019
Resolution: Repairs being completed at 2019 DD.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2018
Resolved
Failed cable insulation on 110V outlets located near bar.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 21 May 2018
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 May 2018
Resolved
Port R/W intake hose clamp requires adjustment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 24 May 2018
Resolution: Hose Fitting was of the barbed type and only required 1 hose clamp.
Stability › Watertight Integrity › General
Issued 19 April 2016
Resolved
Provide a repair proposal to address all four ventilation openings in the hull shell below the main deck (Port & Stbd, Laz & Tank spaces).
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 21 June 2016
Resolution: Vessel provided pictures of completed and installed ventilation openings per their approved repair plan.