Records from 1996 to 2025. Most recent: inspection, 16 January 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
16 January 2025
PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064073
15 January 2025
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064247
28 December 2022
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7613849
26 September 2022
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7562452
24 September 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7565484
19 February 2021
PSC B · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7141949
5 February 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7136566
4 February 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7135880
12 January 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6334975
6 December 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6053471
9 November 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5759879
14 August 2006
Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2748097
28 April 2006
Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2635900
28 March 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2610891
16 March 2005
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2311444
10 February 2004
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2004800
18 January 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1986828
30 October 2002
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1698348
24 September 2002
Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1679771
31 May 2001
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 290450
6 September 2000
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 281499
15 February 2000
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 274549
21 October 1999
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 433986
3 February 1999
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 425362
25 August 1998
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 419340
15 February 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 412875
19 February 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 400456
21 December 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 398835
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2022
Resolved
74 SOLAS (97 Cons) III/19.2 Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During lifeboat steering test PSCO observed rudder unable to fully maneuver to port. Chief engineer stated that vibrtation caused rudder stock to loosen and prevent it from turning to STBD.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 December 2022
Resolution: SDB review class report with satisfactory repairs and test. No further action required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 September 2022
Resolved
ICLL 66 I/25(3) The opening below the lowest course of the guard rails shall not exceed 230mm (9 inches). The other sourses shall be not more than 380mm(15 inches) apart. The railing on port side midships and starboard bow were observed to exceed 15 inches.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 December 2022
Resolution: SDB reviewed class report with rectified repairs. No further action required.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 26 September 2022
Resolved
74 SOLAS (Cons 20) V/18.8 The voyage data recorder system, including all sensors, shall be subject to an annual performancve test. A copy of the certificate of compliance issued by the applicable performance standards, shall be retained on board the ship. A copy of the valid certificate of compliance is not available.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 December 2022
Resolution: SDB reviewed class report. Certificate of compliance issued. VDR performance test completed on 01/11/2022. No further action required.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 September 2022
Resolved
74 SOLAS (Cons 97) II-2/47.2 Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed three of the self-closing doors in the galley fitted with hold back hooks.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2022
Resolution: The hold back hooks were removed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 February 2021
Resolved
11104 - Rescue Boats: Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 min. Rescue boat failed to start after multiple attempts. 74SOLAS(2009)CONS ED. CH.III/REG.14.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2021
Resolution: Witnessed Rescue Boat start on first attempt and run for 3 minutes.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 12 January 2018
Resolved
01 1551 50c ALL SHIPS OVER 150GT, WHEN ENGAGED ON INTERNATIONAL VOYAGES, SHALL BE ON BOARD AN EFFICIENT DAYLIGHT SIGNALING LAMP WHICH SHALL NOT BE SOLELY DEPENDENT UPON THE SHIPS MAIN SOURCE OF ELECTRICAL POWER. THE DAYLIGHT SIGNALING LAMP DOES NOT HAVE AN INDEPENDENT POWER SUPPLY. 74 SOLAS (97) V/11
Due 11 February 2018
Resolved 5 February 2021
Resolution: Received report attesting to satisfactory repair.
Construction/Loadline › Markings › Load Line Mark
Issued 12 January 2018
Resolved
02 1200 40C THE RING, LINES AND LETTERS SHALL BE PAINTED.. IN BLACK ON A LIGHT BACKGROUND. THE LOAD LINE IS PAINTED IN BLUE. ICLL 8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 February 2021
Resolution: Received report attesting to satisfactory repair.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 12 January 2018
Resolved
BEFORE THE SHIP LEAVES PORT AND DURING ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. THE RUDDER ON THE FREEFALL LIFEBOAT WAS FOUND STUCK AND NOT IMMEDIATELY OPERATIONAL. 74 SOLAS (14) III/20.2
Due 12 January 2018
Resolved 12 January 2018
Resolution: CORRECTED ON THE SPOT.
Construction/Loadline › Markings › Load Line Mark
Issued 6 December 2016
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light background. PSCO observed port side load line paint had rubbed off to bare metal. 50AC
Condition: Damaged By Earlier Event
Due 7 January 2017
Resolved 19 December 2016
Resolution: Recieved Class report attesting to deficiency issued on 07DEC16. Vessel has had the load line repainted.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 6 December 2016
Resolved
On ships carrying at least two search and rescue locating devices and equipped with free-fall lifeboats, one of the search and rescue located devices shall be stowed in a free-fall lifeboat. PSCO observed second SART on bridge. 10C
Condition: Improper Installation
Due 7 December 2016
Resolved 7 December 2016
Resolution: crew member installed second SART in free fall lifeboat.
Fire Fighting › International Shore Connection › Bolts
Issued 6 December 2016
Resolved
An international shore connection shall consist of 04 bolts and 08 washers. PSCO observed 01 bolt and 08 washers missing from ISC. 10C
Due 7 December 2016
Resolved 7 December 2016
Resolution: Corrected on the spot. Crew provided missing bolt and washers.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 9 November 2015
Resolved
74SOLAS(14) IX3.1 and ISM Code 2010 6.: The company should ensure all personnel involved in the company's safety management system have an adequate understanding of relevant rules, regulations, codes, and guidelines. Engineering personnel unable to properly demonstrate operation of the OWS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2015
Resolution: Training was provided by Class attesting to the safe and knowledgeable operation of the OWS. SEE attached NKK class report.
Fire Fighting › Firemans Outfit › Axe
Issued 9 November 2015
Resolved
74SOLAS(97)II-1/17.1: A fireman's outfit shall consist of an axe to the satisfaction of the Administration. Each fireman did not have a fire axe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2015
Resolved 13 November 2015
Resolution: Ship received new fire axe. See receipt attached.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 November 2015
Resolved
33CFR156.170(f)(3) The frequency of the test and inspection [for bunker lines] required by this section for vessels must be annually. A bunker line test has not been completed since August 2014.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2016
Resolution: Received, reviewed, and acknowledged [name withheld] bunker line test report and pictures.
Engineering
Issued 18 January 2004
Resolved
VESSEL TO REPAIR CRACKED STEAM DRAIN LINE LEAKING ONTO VENT SYSTEM AND LADDER LEADING OUT OF ENGINE ROOM. SOLAS74/78 CH. II-1 REG33.1 LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 10 February 2004
Resolution: Visual inspection by USCG.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 24 September 2002
Resolved
EMERGENCY GENERATOR FUEL TANK VENT PIPE DISCONNECTED AND OPEN TO EMERGENCY GENERATOR SPACE
Due 30 October 2002
Resolved 30 October 2002
Resolution: Corrected. Ref: ClassNK report #02 LA 0132
Fire Fighting › Structural Fire Protection - General
Issued 24 September 2002
Resolved
A-CLASS FIRE DOOR TO STEERING ROOM NOT GAS-TIGHT DUE TO DAMAGE FROM LEAKING REFRIDGERATION PIPING.
Due 30 October 2002
Resolved 30 October 2002
Resolution: Corrected. Ref: ClassNK survey record # 02 LA 0132
Lifesaving
Issued 21 December 1996
Resolved
THE VESSEL IS A REEFER BULK CARRIER THAT WAS CARRYING VEHICLES WITH GAS IN THE TANKS AND BATTERIES CONNECTED. THE VESSEL WAS NOT EQUIPED WITH PORTABLE COMBUSTABLE GAS DETECTING INSTRUMENTS AS REQUIRED BY SOLAS.THE VESSEL IS REQUIRED TO COMPLY WITH SOLAS CHAP. II-2 REG.53.
Condition: Unknown
Due 20 February 1997
Resolved 20 February 1997