Records from 1984 to 1992. Most recent: inspection, 29 December 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
29 December 1992
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 830171
3 June 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 953174
14 May 1990
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 905459
19 April 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1040884
21 June 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 893657
3 May 1988
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1208630
11 December 1987
Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1001959
18 June 1987
Plan Review "T" Boat
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1317861
29 April 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1019216
18 December 1986
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026817
29 October 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324211
18 September 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1311825
13 August 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 991167
7 August 1986
Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306379
13 May 1986
Deficiency Check · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 995982
22 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1293659
5 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1290536
18 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1286711
18 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1290534
1 June 1984
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 978093
Fire Fighting
Issued 29 April 1987
Resolved
REMOVE FROM SUBJECT VESSEL UNAPPROVED HALON FIRE FIGHTING SYSTEM. REMOVE FIXED HALON SYSTEM FROM VESSEL UNTIL INSTALLATION PLANS ARE APPROVED BY MIO PHILADELPHIA.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Engineering
Issued 29 October 1986
Resolved
REMOVE THE UNAPPROVED FLEXIBLE FUEL HOSE. INSTALL A FLEXIBLE FUEL LINE MEETING THE REQUIREMENTS OF 46 CFR 182.15-40(A)(3).
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Construction/Loadline
Issued 18 September 1986
Resolved
EFFECT REPAIRS IN WAY OF WASTED FRAMING MEMBERS IN WAY OF THE PORT AND STARBOARD HULL TO TRANSOM CONNECTIONS.
Condition: Unknown
Due 18 September 1986
Resolved 18 September 1986
Construction/Loadline
Issued 18 September 1986
Resolved
RENEW OR EFFECT REPAIRS TO THE CRACKED FLOOR MEMBER LOCATED BELOW THE BATTERY BOX.
Condition: Unknown
Due 18 September 1986
Resolved 18 September 1986
Fire Fighting
Issued 7 August 1986
Resolved
DEMONSTRATE PROPER OPERATION OF THE VESSEL'S POWER VENTILATION AND INTERLOCK TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Engineering
Issued 7 August 1986
Resolved
RENEW ALL FUEL LINES INCLUDING THOSE ON PORT AND STARBOARD ENGINES LEADING FROM FUEL PUMP TO CARBURATOR AND FUEL TANK TO FUEL PUMP SO AS TO COMPLY WITH 46 CFR 162.15-40(A)(3) PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Fire Fighting
Issued 7 August 1986
Resolved
SERVICE AND REINSTALL ALL EXPENDED FIRE EXTINGUISHING EQUIPMENT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Electrical
Issued 7 August 1986
Resolved
PROVIDE FOR REVIEW BY CG PLAN REVIEW OFFICER MIO PHILADELPHIA, WIRING DIAGRAM FOR PORT AND STARBOARD ENGINES PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Accommodation/Occupational Safety
Issued 22 April 1985
Resolved
PROVIDE 36 INCH SAFETY RAILS AROUND COCKPIT.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985