Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)48.0 ft × 30.0 ft × 6.5 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)48.0 ft × 30.0 ft × 6.5 ft
ITC tonnageNot recorded
BuilderT.D. VINETTE COMPANY · ESCANABA, MI, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHARSEN'S ISLAND, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 May 2025 · expires 30 June 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Net Ton 81 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 20 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 20
23 September 2025Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8238649
7 March 2025Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8090171
19 October 2024Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8038177
3 October 2024Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8013163
19 September 2023Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7794286
15 December 2022Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7613387
15 September 2022COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7559339
14 October 2021Annual Inspection · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7332369
18 May 2021Plan Review "T" Boat
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7205268
18 May 2021Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7205329
7 October 2020Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7073028
17 December 2019Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6875153
16 December 2019Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6874834
16 October 2019Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6835951
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021Resolved
Each floating water light must be approved IAW 10.010. Battery in life ring light is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
Resolution: The life ring light has been replaced with the ACR, SM-3 model
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021Resolved
Each floating waterlight carrying only one life ring must be attached to the lanyard with a corrosion resistant clip allowing the waterlight to be quickly disconnected. Clip in place was no able to be quickly disconnected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 24 May 2021
Resolution: The life ring clip has been replaces with a stainless steel clip that has a thumb retractable closure
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021Resolved
All equipment including lamp holders shall be of a type designed. Enclosure for lighting fixture in the engine room was melted and cracked and improperly installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 24 May 2021
Resolution: The damaged mainland engine room light has been removed from the vessel. There is adequate lighting in this area without the light installed for all maintenance and emergency activities.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2021Resolved
Diesel fuel was found to be collected in the enclosure around the fuel fill on deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
Resolution: The fuel has been removed from the fuel fill overflow box.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2021Resolved
All portable fire extinguishers installed shall be of an approved type. Fire extinguisher in the wheel house bracket is missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 24 May 2021
Resolution: The pilot house fire extinguisher bracket has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2020Resolved
EACH RING LIFE BUOY MUST BE APPROVED IAW SUBCHAPTER Q. LINE ENCIRCLING BODY OF THE RING BUOY IS DETERIORATED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 21 October 2020
Resolution: Received emailed photo of new line on life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 December 2019Resolved
The vessel sustained a failure of the marine gear (throttle actuator) where the gear failed to shift and caused an allision with the pier/platform structure. Provide for a technical service report from certified rep and provide for USCG inspection prior to returning to passenger service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2020
Resolution: New servo controllers installed and operationally tested with service rep onboard. All sat.
Vessel shall keep an accurate passenger count on shore for each voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 17 December 2018
Resolution: Company is keeping a passenger count ashore. Phoneing the count to local PD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2018Resolved
Vessel's name needs to be in block letters on the lifebouy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 29 October 2018
Resolution: Exemption given
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 September 2018Resolved
Renew or replace fuel fill hose to tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2018
Resolved 28 September 2018
Resolution: Rubber fill hose was replaced.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.