SAN DIEGO

SAN DIEGO is a 1965 passenger vessel (inspected). The Coast Guard has recorded 93 inspections since 1985, most recently in May 2026, along with 174 deficiencies, 1 operational control, 1 with no removal date recorded and 2 casualty investigations between 2001 and 2025.

Records from 1985 to 2026. Most recent: inspection, 13 May 2026.

Built
1965
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDI6997
Flag
UNITED STATES
366941950, 367724330 (licence lapsed)
Maury page id
psix-44985

Inspections, by type

…with no type recorded11
Years with a record 39 calendar years (1985–2026)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)67.9 ft × 22.3 ft × 4.7 ft
Registered tonnagegross 67 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR & DONALDSON · COSTA MESA, CA, UNITED STATES · built 1965
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 26 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI6997MMSI 367724330 · expired · compulsorily equipped · granted 30 March 2016, cancelled 30 May 2026
WAX4448MMSI 366941950 · expired · compulsorily equipped · granted 21 April 2004, cancelled 12 July 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 93

13 May 2026 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8372234
19 February 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8312637
11 December 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8273439
14 July 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8196755
13 March 2025 In-Service Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8093366
18 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7897483
7 December 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7828763
14 April 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7668430
16 March 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7652189
18 January 2022 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7378565
9 December 2021 Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7365599
4 March 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7150223
12 March 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6925677
4 December 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6865542
21 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6838972
26 March 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6649878
1 February 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6347656
5 December 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6308967
2 February 2017 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6075592
30 December 2016 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6064025
7 November 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6037133
16 March 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5834353
13 January 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5775014
3 February 2012 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4234554
19 December 2011 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4211030
4 January 2011 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3920207
1 March 2010 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3674161
5 January 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3658939
17 February 2009 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3419269
31 March 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3174964
25 March 2008 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3153423
7 January 2008 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3122949
20 September 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3061986
26 March 2007 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2882753
16 February 2007 Deficiency Check · Deadweight Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2873101
18 April 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2611340
16 March 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2600183
24 March 2005 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2318745
9 December 2004 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2229510
15 April 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2016422
28 April 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1799380
26 February 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1749760
2 December 2002 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1598615
4 April 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1598625
23 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 40820
23 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 232110
23 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1738991
25 April 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373437
2 May 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1401245
22 April 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 793325
12 April 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1449161
1 April 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 784486
2 March 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375682
27 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1402651
21 November 1997 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1112349
17 April 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364178
9 April 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1465914
17 June 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1089828
17 June 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1396531
11 April 1996 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1359231
13 April 1995 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1434232
27 March 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1446186
13 October 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 3626
14 April 1994 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379946
24 February 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1426870
23 April 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1141299
23 February 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1150906
13 March 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1256652
24 February 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1262460
4 June 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1314225
2 May 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 902735
14 March 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1225512
13 March 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 913528
12 March 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 908904
6 March 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1217133
5 March 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 920665
20 December 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 905316
14 June 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 896125
19 April 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 894940
7 March 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 887781
13 February 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1036731
7 February 1989 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1338855
10 November 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 890251
18 October 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1195173
7 March 1988 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1335036
4 November 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1020784
18 June 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1003576
10 March 1987 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1318769
3 November 1986 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1320599
22 October 1986 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1316590
9 April 1986 Credit Drydock · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1299991
25 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 979528
12 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 978687

Deficiency record · 174

09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 19 February 2026 Resolved
Vessel did not have alcohol test strips on board
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2026
Resolution: Vessel had test strips
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 February 2026 Resolved
Vessel did not have required flares on board
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2026
Resolution: Vessel had flares
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2026 Resolved
Two life ring buoys need to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2026
Resolution: Vessel had adequate life ring buoys
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2026 Resolved
Inspection and testing/replacements of life jacket lights
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2026
Resolution: Vessel had adequate life jacket lights
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 February 2026 Resolved
FCC Safety Radio Telephony and bridge to bridge certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2026
Resolution: Vessel had FCC license on board
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 February 2026 Resolved
replacement of expired medications in first aid kit
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2026
Resolution: Vessel had up to date medications in first aid kit
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 February 2026 Resolved
replacement of straight stream fire nozzles with varying nozzles
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2026
Resolution: Vessel had proper nozzles
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2026 Resolved
water light attachment line with corrosion resistant clip. Water light line should be 3-6ft
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2026
Resolution: Water light was properly attached
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2025 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. CO2 Pressure switch shutdown was seized and inoperable. Replace pressure switch and test system to ensure proper operation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2025
Resolution: System serviced and test witnessed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 March 2025 Resolved
Interconnected detection and alarm system be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas. Smoke detection was found to be inoperable. Replace existing smoke detection with a system meeting UL 217 rating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2025
Resolution: Witnessed test of fire alarms.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2025 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems,or any space into which carbon dioxide might migrate must be conspicuously marked as follows:
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2025
Resolution: placards in place.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 April 2024 Resolved
Provide gasket for the forepeak hatch cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2024
Resolution: Gasket was provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 April 2024 Resolved
Provide vessel with DSC radio. Radio must have vessel MMSI number and lat/long information.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 19 April 2024
Resolution: DSC radio was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 January 2022 Resolved
Complete maintenance or replace starboard main diesel engine turbo found smoking slightly from exhaust side V-band clamp.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2022
Resolution: Cleared by attending MI; turbo was replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 January 2022 Resolved
Remove unauthorized repairs at stem for further inspection by marine inspector. Provide permanent repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2022 Resolved
Tighten or replace fuel line inlet found loose on forward generator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2022 Resolved
Ensure fuel tank vent line maintains upward slope to vent outlet.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 January 2022 Resolved
Create vent closure device and mount near engine room supply vent.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 January 2022 Resolved
Complete annual service of extra fire extinguisher found in galley space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 January 2022 Resolved
Properly mount 02 fire extinguisher at entrance to the engine room in proper.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 January 2022 Resolved
Replace missing smoke detector in galley/salon space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 January 2022 Resolved
Mount refrigerator and microwave to deck or bulkhead in galley.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 January 2022 Resolved
Make aft engine room bulkhead watertight at hydraulic piping for steering gear on stbd side.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Received pictures of watertight repair (marine sealant with screwed wooden backing. Added to vessel e-file.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 January 2022 Resolved
Correct the following wiring discrepancies: dead-end wires and light fixture cover in void under bridge, missing outlet faceplate under helm, wiring overhead support in forepeak.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 January 2022 Resolved
Mark all lifefloats with vessel name and person capacity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 January 2022 Resolved
Repair netting on 01 lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 7 March 2022
Resolution: Cleared by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021 Resolved
03 adult lifejackets that were unserviceable. Total adult person count on vessel shall not exceed 74 until the deficiency is corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 4 March 2021 Resolved
Moving components on the bilge pump were exposed. Provide a safety guard around the exposed moving components of the bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 4 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 March 2021 Resolved
Fire pump guage was found to be unserviceable. Provide a working guage for the fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 4 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2020 Resolved
Provide Merchant Mariner Medical card.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 5 April 2020
Resolution: MMC medical card provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 March 2020 Resolved
Provide 03 new ringbuoys. Current ring buoys are deteriorated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2020
Resolution: New ring buoys provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 March 2020 Resolved
Mark all lifefloats with vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2020
Resolution: Name provided on life floats.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 March 2020 Resolved
Provide VHF DSC radio.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2020
Resolution: VHF DSC radio porvided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2020 Resolved
Provide battery box lid for bridge equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2020
Resolution: Battery lid provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2020 Resolved
Provide new shore power cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2020
Resolution: Shore power cable provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 March 2020 Resolved
Provide label for emergency fuel shutoff.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2020
Resolution: Label provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 March 2020 Resolved
Provide new housing and instructions for CO2 pull device on deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 13 March 2020
Resolution: Housingand instructions provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 March 2020 Resolved
Attach fire main valve handle on starboard side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 13 March 2020
Resolution: Fire main valve handle attached.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 March 2020 Resolved
Provide working gauge for fire main pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 18 June 2020
Resolution: Working gauge provided for fire main.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 March 2020 Resolved
Provide working light for all life floats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2020
Resolution: Light provided for life float.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 March 2020 Resolved
Provide engine room visual bilge high water alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 5 April 2020
Resolution: Bilge alarm lights installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2020 Resolved
Make air conditioning pump electrical conform with regulations. Wire through switch and install a fuse.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 June 2020
Resolution: Electrical now conforms with reulations.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 13 December 2017 Resolved
Replace/service portable fire extinguisher located in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2019
Resolution: Fire ext was serviced. cleared.
Construction/Loadline › Hull › Side Shell
Issued 13 December 2017 Resolved
Remove, clean, and treat angel hair as identified in engine room and lazzarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2018
Resolved 5 December 2019
Resolution: Updated, Cleared. Work completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 December 2017 Resolved
Secure electrical cables in the engine room with metalic clamps at least every 24".
Due 5 January 2018
Resolved 13 December 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 December 2017 Resolved
Make engine room aft bulkhead watertight, especially in way of wire penetrations.
Due 5 January 2019
Resolved 13 December 2017
Engineering › Bilge Water Management System › Pump
Issued 3 February 2017 Resolved
Provide a second fixed power bilge pump IAW 46 CFR 182.520 prior to carriage of passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2017
Resolved 10 February 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 3 February 2017 Resolved
Provide 02 adult PFD's. Vessel restricted to 75 passengers.
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 10 February 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 February 2017 Resolved
Prove proper operation of the ring buoy floatlight and one identified lifefloat light.
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 10 February 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 February 2017 Resolved
Prove newly installed nav lights are listed under UL1104 IAW 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 10 February 2017
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 3 February 2017 Resolved
Provide proper overcurrent protection (fuses) IAW 46 CFR 183.380(k)(1).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 10 February 2017
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 3 February 2017 Resolved
Provide emergency broadcast placard IAW 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 3 February 2017
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Platform
Issued 3 February 2017 Resolved
Provide spacers for the forward most group of lifefloats 46 CFR 180.132(f).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 10 February 2017
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 16 March 2016 Resolved
Provide 04 adult lifejackets.
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 15 April 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 16 March 2016 Resolved
Provide current FCC Radio station license and safety radio certificate
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 15 April 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 March 2016 Resolved
Prove proper operation of emergency lighting in galley.
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 15 April 2016
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 16 March 2016 Resolved
Provide UL smoke detecor in galley.
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 15 April 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 29 January 2016 Resolved
Recharge/replace fire extinguisher on engine room port side.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2016
Resolved 25 February 2016
Resolution: Def Cleared
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 January 2016 Resolved
Remove angel hair and rot in bunk room and engine room port side. Clean to solid wood and treat. Lower longitudinals most affected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 21 January 2016
Resolution: Affected areas cleaned and treated.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 January 2016 Resolved
Repair electrical cable brackets in bunk room port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 21 January 2016
Resolution: Cable brackets repaired.
Construction/Loadline › Penetrations › Valve Flange
Issued 13 January 2016 Resolved
Repair/replace port bow ball valve for bait tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 21 January 2016
Resolution: New ball valve installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 January 2016 Resolved
Make collision bulkhead watertight by permanently replairing plugged holes. Upper stbd side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 21 January 2016
Resolution: Holes permanently plugged.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 3 February 2012 Resolved
Provide Drug and Alcohol program for audit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2012
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 February 2012 Resolved
9 life jackets were determined to be unservicable.
Action required: 705 - Other - as specified
Due 9 March 2012
Resolved 1 March 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 February 2012 Resolved
Vessel is not configured with a mast head light. Provide mast head light that meets UL 1104 standard.
Action required: 705 - Other - as specified
Due 9 March 2012
Resolved 1 March 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 3 February 2012 Resolved
Provide instructions for the E/R fixed CO2 system at the pull box IAW 46CFR185.612(a)
Action required: 705 - Other - as specified
Due 9 March 2012
Resolved 1 March 2012
Communications › Visual Communication › Warning Sign (gangway)
Issued 3 February 2012 Resolved
Conspicuously mark lazaretto IAW 46CFR185.612(f) "Carbon Dioxide Fire Extinguishing Apparatus"
Action required: 705 - Other - as specified
Due 9 March 2012
Resolved 1 March 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 February 2011 Resolved
CO2 fire system failed to shut down port engine during test. Prove proper operation IAW 46 CFR 181.410. Restricted vessel from carrrying passengers.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 18 February 2011
Resolution: Switch replaced and witnessed satisfactory test of CO2 system engine shutdown and override.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 February 2011 Resolved
Install port and stbd engine shaft guards.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: Shaft guards installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 18 February 2011 Resolved
Fire Extinguisher inspections expired Feb 23, 2011. Provide current inspection.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 23 February 2011
Resolution: Received copy of Simlex Grinnell service report.
Fire Fighting › Firemans Outfit › Axe
Issued 18 February 2011 Resolved
Mount fire axe in pilot house.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: Fire axe properly mounted.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 18 February 2011 Resolved
Stbd pilot house glass cracked, remove and replace glass to the satisfaction of [name withheld] 46 CFR 177.1030.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: Pilot house glass replaced.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 February 2011 Resolved
Update Light List.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: Updated light list on board.
Navigation › Piloting/Steering › Marine Charts
Issued 18 February 2011 Resolved
Update charts.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: Updated charts on board.
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 February 2011 Resolved
Post lifejacket donning placard to represent current lifejacket types.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: Proper lifejacket donning placard posted.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 February 2011 Resolved
Remove and replace all float light batteries with manufactor approved batteries IAW 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: All float light batteries properly replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 18 February 2011 Resolved
Remove and replace ring buoy retro tape IAW 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: Ring buoy retro tape properly renewed.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 February 2011 Resolved
Replace 4 adult lifejackets.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: 4 new adult lifejackets on board.
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 February 2011 Resolved
Install magnetic compass light IAW 46 CFR 184.402. Restricted to daylight operations only.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 28 February 2011
Resolution: Magnetic compass light properly installed.
Communications › Radio Communications › EPIRB
Issued 1 March 2010 Resolved
Provide current EPRIB NOAA registration, vessel restricted to 3NM from shore until corrected.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 March 2010 Resolved
Provide current EPIRB hydrostatic release.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Documentation › Certificates/Documents › FCC SSL
Issued 1 March 2010 Resolved
Provide current FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 March 2010 Resolved
Repair/replace port ringbuoy waterlight.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 1 March 2010 Resolved
Provide retroreflective tape on (8) child-size PFDs.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 March 2010 Resolved
Update signage for PFD stowage to reflect actual number of PFDs carried on board.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 March 2010 Resolved
Provide high water bilge alarm in forepeak as per 46 CFR 182.530(b).
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 March 2010 Resolved
Provide PFD donning placard.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 March 2010 Resolved
Provide current US Coast Pilot, or extracts.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 1 March 2010 Resolved
Repair E/R ventilation closure devices.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 March 2010
Fire Fighting › Fire Hoses › Condition
Issued 17 February 2009 Resolved
Replace Port Fire hose
Action required: 705 - Other - as specified
Resolved 3 March 2009
Resolution: Fire hose was renewed
Fire Fighting › Fire Hydrants › Condition
Issued 17 February 2009 Resolved
Replace p/s Fire station valves
Action required: 705 - Other - as specified
Resolved 3 March 2009
Resolution: Both fire stations valves were replaced
Communications › Audible Communications › Horn/Whistle
Issued 25 March 2008 Resolved
Repair/replace ship's horn.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 March 2008 Resolved
Provide current alcohol test kits.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 1 April 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 March 2008 Resolved
Repair high water bilge alarm visual display for Laz.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Communications › Radio Communications › EPIRB
Issued 25 March 2008 Resolved
Provide current EPIRB NOAA registration.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Documentation › Certificates/Documents › FCC SSL
Issued 25 March 2008 Resolved
Provide current FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 25 March 2008 Resolved
Replace retro-reflective tape on PFDs, as identified.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 31 March 2008
Fire Fighting › Fire Pumps › Pressure
Issued 25 March 2008 Resolved
Repair/replace fire pump pressure gauge.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 March 2008 Resolved
Label remote emergency fuel shut off valves (on deck).
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 25 March 2008 Resolved
Repair E/R ventilation damper (middle damper).
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 March 2008 Resolved
Provide current US Coast Pilot, tide tables, tidal current tables, or extracts.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Documentation › Markings/Placards › Capacity Marking
Issued 25 March 2008 Resolved
Label maximum passengers allowed on upper deck (27), as per Stability Letter.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 26 March 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 26 March 2007 Resolved
Repair or replace SSB
Action required: 705 - Other - as specified
Resolved 20 April 2007
Resolution: SSB has been replaced
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 26 March 2007 Resolved
Install smoke dectectors in the galley and crew bunk room
Action required: 705 - Other - as specified
Resolved 29 March 2007
Resolution: Smoke detectors have been installed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 March 2007 Resolved
Install CO2 over ride for the engines
Action required: 705 - Other - as specified
Resolved 29 March 2007
Resolution: Override has been installed
Fire Fighting › Grease Extraction Hood › General
Issued 26 March 2007 Resolved
Comply with the Cid policy # 20, vsl has 6 months to comply
Action required: 705 - Other - as specified
Resolved 25 September 2007
Resolution: Vsl now complies with Grease Extraction Hood.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 26 March 2007 Resolved
Replace 23 adult and 1 child life jackets, vsl is limited to 65 persons
Action required: 705 - Other - as specified
Resolved 20 April 2007
Resolution: Life jackets have been replace with lights
Stability › Watertight Integrity › General
Issued 26 March 2007 Resolved
Cap hydraulic line in the fwd bulkhead.
Action required: 705 - Other - as specified
Resolved 29 March 2007
Resolution: Lines were capped off
Electrical › Lighting (service) › Lighting Fixture
Issued 26 March 2007 Resolved
Repair or renew light in the lazerette.
Action required: 705 - Other - as specified
Resolved 29 March 2007
Resolution: Light has been replaced
Navigation › Piloting/Steering › Notices to Navigation
Issued 26 March 2007 Resolved
Install Navtex, limited to 100 mile from shore
Action required: 705 - Other - as specified
Resolved 20 April 2007
Resolution: Navtex has been installled
Stability › Incline Test › General
Issued 11 February 2007 Resolved
Conduct stability test review of current lightship and full load conditions as compared to original 1965 data. Submit calculations performed by naval architect or professional engineer to Sector San Diego.
Due 15 May 2007
Resolved 31 March 2008
Resolution: MSC Stability Letter issued 13MAR08.
Navigation › Piloting/Steering › Marine Charts
Issued 18 April 2006 Resolved
Provide currently corrected Coast Pilot [name withheld], and navigation charts for areas transited.
Due 1 May 2006
Resolved 4 May 2006
Resolution: Purchased new Coast Pilot [name withheld], and navigation chart.
Fire Fighting › Grease Extraction Hood › General
Issued 18 April 2006 Resolved
Clean galley hood vent ducting. Correct prior to using galley griddle.
Due 1 May 2006
Resolved 4 May 2006
Resolution: Vent & entire hood thoroughly cleaned and is now on a weekly cleaning schedule.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2006 Resolved
Ensure all 1st aid items are not expired and all contents meet 46CFR160.041 (handout)
Due 1 May 2006
Resolved 4 May 2006
Resolution: Replaced all expired items in 1st Aid kit with with new items.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 18 April 2006 Resolved
Replace line on lifefloat lights (4) located on top of wheelhouse.
Due 1 May 2006
Resolved 4 May 2006
Resolution: Removed lifefloats from top of wheelhouse. Lifefloats are not being used att so they don''t need to be on the boat.
Lifesaving › Buoyant Apparatus › Float Free
Issued 18 April 2006 Resolved
Remove debris (line, etc) from top of wheelhouse preventing lifefloat float-free arrangement.
Due 1 May 2006
Resolved 4 May 2006
Resolution: All debris removed from wheelhouse top.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 April 2006 Resolved
Double hose clamp stbd M/E raw water cooling hose.
Due 1 May 2006
Resolved 4 May 2006
Resolution: Hose has been double clamped.
Stability › Watertight Integrity › General
Issued 18 April 2006 Resolved
Replace/repair lazzarette hatch gasket.
Due 1 May 2006
Resolved 4 May 2006
Resolution: Sealed hatch, no longer used. Laz can be accessed through a forward compartment.
Lifesaving › Lifebuoys › Serviceable
Issued 24 March 2005 Resolved
Two life bouys are wasted due to location on deck.
Condition: Damaged By Earlier Event
Due 15 April 2005
Resolved 14 April 2005
Resolution: Vsl purchased new life bouys.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 24 March 2005 Resolved
Emergency broadcast placard was wasted and unable to be read.
Condition: Improper/Lack of Maintenance
Due 15 April 2005
Resolved 14 April 2005
Resolution: Vsl rep picked up new emergency broadcast placard from USCG.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 December 2004 Resolved
Treat area of concern, engine room, port side, near fuel tank.
Due 4 January 2005
Resolved 3 January 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 April 2004 Resolved
Provide current copies of Rules of the Road, Light List, and Coast Pilot.
Due 22 April 2004
Resolved 13 April 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 April 2004 Resolved
Properly support eshaust piping in Lazaret.
Due 22 April 2004
Resolved 13 April 2005
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 28 April 2003 Resolved
Provide annual drug report for 2002 IAW 46 CFR 16.500.
Due 28 May 2003
Resolved 22 May 2003
Lifesaving › Liferaft Equipment
Issued 28 April 2003 Resolved
Provide adequate spacers for life floats IAW 46 CFR 180.137(f).
Due 28 May 2003
Resolved 5 June 2003
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 28 April 2003 Resolved
Repair retro-reflective tape on (14) identified PFD's IAW 46 CFR 185.604(h).
Due 28 May 2003
Resolved 22 May 2003
Engineering › Sea-water System (primary cooling)
Issued 28 April 2003 Resolved
Double clamp saltwater discharge hose for starboard main engine. LEGACY COMPONENT DESC: Piping
Due 28 May 2003
Resolved 5 June 2003
Engineering › Sea-water System (primary cooling)
Issued 28 April 2003 Resolved
Repair leak to port main engine saltwater cooling system IAW 46 CFR 182.420(a)(3). LEGACY COMPONENT DESC: Piping
Due 28 May 2003
Resolved 5 June 2003
Lifesaving › Lifejacket/PFD (General)
Issued 28 April 2003 Resolved
Provide lifejacket placards for PFD's stowed in galley area IAW 46 CFR 180.78. LEGACY COMPONENT DESC: Storage
Due 28 May 2003
Resolved 5 June 2003
Engineering › Bilge Water Management System
Issued 2 December 2002 Resolved
Remove pedro tube from forepeak bilge line and replace with metal. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 December 2002
Resolved 9 October 2003
Engineering › Feedwater/Condensate Water System
Issued 4 April 2002 Resolved
Secure bait tank pump to mountings LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Due 15 May 2002
Resolved 19 April 2002
Engineering › Bilge Water Management System
Issued 4 April 2002 Resolved
provide operating bilge alarm in galley LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Due 15 May 2002
Resolved 19 April 2002
Engineering › Steering Gear System
Issued 4 April 2002 Resolved
Install metallic clamps on hydraulic lines in the lazarette. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper Installation
Due 15 May 2002
Resolved 19 April 2002
Engineering › Feedwater/Condensate Water System
Issued 4 April 2002 Resolved
Secure fire pump to mountings LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Due 15 May 2002
Resolved 19 April 2002
Engineering › Sea-water System (primary cooling)
Issued 4 April 2002 Resolved
Double hose clamp all RW cooling hoses LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 15 May 2002
Resolved 19 April 2002
Electrical › Electric Supply System (service)
Issued 4 April 2002 Resolved
Install metallic clamps on cable runs in ER and lazarette LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 15 May 2002
Resolved 19 April 2002
Electrical › Electrical Distribution System (service)
Issued 4 April 2002 Resolved
Install cover over RCPT outlets in ER and galley LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 19 April 2002
Lifesaving › Buoyant Apparatus
Issued 4 April 2002 Resolved
Remove tie wraps from sea painter on life float installation
Condition: Improper Installation
Due 15 May 2002
Resolved 15 April 2002
Lifesaving › Buoyant Apparatus
Issued 4 April 2002 Resolved
Tie paddles into life floats
Condition: Improper Installation
Due 15 May 2002
Resolved 19 April 2002
Stability › Watertight Integrity
Issued 4 April 2002 Resolved
seal penetrations on FWD and aft BLKHDs in Er.
Condition: Improper Installation
Due 15 May 2002
Resolved 19 April 2002
Engineering › Lubricating Oil Storage/Transfer System
Issued 4 April 2002 Resolved
Clean ER bilges
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 19 April 2002
Accommodation/Occupational Safety › Ventilation
Issued 4 April 2002 Resolved
Install blade guards over fans in lazarette
Condition: Improper Installation
Due 19 May 2002
Resolved 19 April 2002
Fire Fighting › Remote Fuel Shutoff
Issued 4 April 2002 Resolved
Lable fuel shut off valves
Condition: Improper Installation
Due 15 May 2002
Resolved 19 April 2002
Lifesaving
Issued 27 April 1998 Resolved
Provide complete first aid kit.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Construction/Loadline
Issued 27 April 1998 Resolved
Provide identification for bilge manifold lines in engine room.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Documentation
Issued 17 June 1996 Resolved
Post Stability Letter in the vessel's pilot house. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 17 June 1996 Resolved
Post Certificate of Inspection in a conspicuous place on the vessel. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 17 June 1996 Resolved
Provide local notice to mariners. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 17 June 1996 Resolved
VESSEL CERTIFICATE OF INSPECTION NOT POSTED. _x001C_
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Navigation
Issued 17 June 1996 Resolved
VESSEL IS MISSING LOCAL NOTICE TO MARINERS._x001C_
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 17 June 1996 Resolved
VESSEL STABILITY LETTER IS NOT POSTED._x001C_
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Lifesaving
Issued 13 April 1995 Resolved
LIFE RING HAS FIVE INCH SPLIT ON INSIDE SEAM.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Lifesaving
Issued 13 April 1995 Resolved
EIGHT LIFE JACKETS WERE REJECTED FOR EITHER BAD SNAPS, MISSING STRAPS OR RIPPED DURING INSPECTION.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Lifesaving
Issued 13 April 1995 Resolved
CLASS A EPIRB MISSING VESSEL NAME.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Engineering
Issued 27 March 1995 Resolved
RENEW PORT CUTLASS BEARING. ADVISED OWNER TO CHECK ALIGNMENT OF PORT MDE.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 27 March 1995 Resolved
PROPERLY TERMINATE ALL DEAD END WIRES OR PULL THEM FROM THE RUNS IAW SUBCHAPTER J.
Condition: Unknown
Due 13 April 1995
Resolved 18 April 1995
Electrical
Issued 27 March 1995 Resolved
REPAIR LEAK IN MANIFOLD ON SSG.
Condition: Unknown
Due 13 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 27 March 1995 Resolved
REPLACE 2 INCH AUX THRU HULL VALVE PRIOR TO SPLASHING
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Navigation
Issued 27 March 1995 Resolved
REPLACE TIE ROD BETWEEN RUDDER POSTS AND THEIR ASSOCIATED BALL JOINTS.
Condition: Unknown
Due 13 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 24 February 1994 Resolved
MAKE VALVE HANDLE SHUT-OFF FOR BILGE LINE PENETRATING COLLISION BULKHEAD ACCESSIBLE FROM THE DECK.
Condition: Unknown
Due 24 February 1994
Resolved 24 February 1994
Construction/Loadline
Issued 2 May 1991 Resolved
REMOVE AND REPAIR THE WOOD ROT TO GOOD WOOD IN WAY OF MAIN DECK UNDERLAYMENT, STARBOARD SIDE OF THE ENGINE ROOM.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Construction/Loadline
Issued 2 May 1991 Resolved
PROVIDE MEANS OF STOPPING THE WOOD ROT THAT IS STARTING TO APPEAR IN VARIOUS AREAS OF THE ENGINE ROOM.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Fire Fighting
Issued 6 March 1991 Resolved
INSTALL PRESSURE GAUGE TO THE FIRE PUMP.
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Construction/Loadline
Issued 19 April 1989 Resolved
PROPERLY INSTALL RAILINGS ALONG THE PERIPHERY OF THE UPPER DECK PORT&STBD. PROVIDE AND SUBMIT DRAWING OF THE RAILINGS TO BE INSTALLED. RESTRICT THIS AREA FROM ANY PASSENGERS USE UNTIL SATISFACTORY CORRECTED.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Unknown
Issued 10 November 1988 Resolved
VESSEL IS LIMITED TO (116) PASSENGERS WHEN OPERATING IN LIMITED COASTWISE UNTIL STABILITY RE-CALCULATION IS APPROVED BY COMMANDANT G-MSC-1.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Documentation
Issued 7 March 1988 Resolved
PROVIDE CURRENT COMMUNICATIONS ACT SAFTEY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 7 March 1988
Resolved 7 March 1988
Documentation
Issued 7 March 1988 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 7 March 1988
Resolved 7 March 1988
Engineering
Issued 4 November 1987 Resolved
INSTALL GUARD ON ROTATING COUPLING OF BILGE PUMP.
Condition: Unknown
Due 4 November 1987
Resolved 4 November 1987
Electrical
Issued 4 November 1987 Resolved
REPAIR ALL ELECTRICAL WIRING SPLICES WITH METAL CRIMP TYPE CONNECTORS.
Condition: Unknown
Due 4 November 1987
Resolved 4 November 1987
Lifesaving
Issued 10 March 1987 Resolved
REPLACE 2 CAN WATER LIGHTS ON RING BUOY AND 1 LIFE FLOAT WITH COAST GUARD APPROVED WATER LIGHTS.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Lifesaving
Issued 10 March 1987 Resolved
REPLACE RECALLED CAL JUNE PFD LIGHTS WITH UPGRADED PFD LIGHTS.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Construction/Loadline
Issued 22 October 1986 Resolved
REPLACE FORE PEAK HATCH COVER.
Condition: Unknown
Due 22 October 1986
Resolved 22 October 1986
Construction/Loadline
Issued 22 October 1986 Resolved
PROVIDE STUFFING BOXES FOR CONTROL CABLES THRU ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 22 October 1986
Resolved 22 October 1986
Documentation
Issued 22 October 1986 Resolved
POST CERTIFICATE OF INSPECTION AND STABILITY LETTER.
Condition: Unknown
Due 22 October 1986
Resolved 22 October 1986

Casualty record · 2

23 June 2001Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1738991
14 July 2025Routine · role: Involved in a Marine Casualty · activity 8196755
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.