Records from 2006 to 2025. Most recent: inspection, 8 October 2025.
Inspection history · 26
8 October 2025
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8251942
10 April 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8112455
4 October 2024
Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8014593
23 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7923168
12 April 2023
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7675415
6 April 2023
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7664117
25 January 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7608134
4 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7421189
19 July 2021
Deficiency Check · Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7261001
19 July 2021
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7261759
14 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7176761
26 January 2021
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7179300
30 November 2020
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7118311
2 November 2020
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7088530
14 July 2020
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7006139
21 April 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6942596
20 March 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6925002
20 March 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6929771
8 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6820739
11 March 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6653774
7 February 2019
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6619771
21 December 2018
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6600308
6 February 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6339229
10 January 2017
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6069655
21 December 2016
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6057181
16 February 2016
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5811361
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2024
Resolved
Remove rot on longitudinal frame on the port side in the engine room as pointed out by the marine inspector.46 CFR 176.600
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 April 2025
Resolution: Wood rot removed and treated. All SAT
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2024
Resolved
Remove rot in lazarette as pointed out by the marine inspector during the ISE.46 CFR 176.600
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 April 2025
Resolution: Wood rot removed and treated. All SAT
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2024
Resolved
During the In-service Inspection, an area of delamination with water intrusion was noticed on the starboard side-shell on the outward side of the false bulkhead in passenger berthing also known as the starboard void. The seam of the sheets of plywood was separated. The area was found with approximately 2 cups of water caught below. When the plywood was pressed on, an air pocket was found in between the sheets of plywood.
Investigate cause of water intrusion and full extent of damage, submit repair proposal to make the vessel structurally sound and water tight.
46 CFR 176.600
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 April 2025
Resolution: Significate repairs (STBD side plywood sheets were removed to the frame; 1/4 away from the stern and 3/4 from the bow) were completed. Observed no signs of water intrusion or panting, while underway during sea trials. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2024
Resolved
Excessive water was found entering the crew berthing. Water is presumed to be coming from escape hatch. Identify source of water intrusion and make water tight.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 April 2025
Resolution: Seals replaced on scuttle cover. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2024
Resolved
Provide an interlock device to prevent generator and shore power from being energized simultaneously.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 18 April 2025
Resolution: Vessel provided image of interlock device. All SAT
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 May 2024
Resolved
The lazarette compartment bilge alarm audible indicator was quieter than the other compartments. Make repairs.
Action required: 10 - Deficiency Rectified
Due 23 May 2024
Resolved 23 May 2024
Resolution: Vessel rep repaired the wiring and audible level was restored.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023
Resolved
Vessel must have at least one ring buoy at least 24 inches in diameter. Vessels ring life buoy was deteriorated beyond repair with one side completely discolored.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: Verified onboard vessel; [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 April 2023
Resolved
Provisions shall be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system.
The two fire dampers to the engine room would not be held close in the event of a fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: Verified onboard vessel; [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 4 April 2022
Resolved
Access ladder to Lazarette void not secured at bottom. Install securing hardware.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 10 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022
Resolved
Rudder void FWD bulkhead STBD side electrical cable dead ended; remove cable or terminate into junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 10 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 4 April 2022
Resolved
Engine room Generator/ shore power electrical panel missing circuit breaker interlock to prevent energizing two sources simultaneously.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 19 April 2022
Resolution: Verified; [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022
Resolved
Engine room FWD bulkhead at center line electrical panel
opening at bottom left corner; install cable cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 10 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022
Resolved
Engine room overhead generator panel behind ladder; opening at right side of electrical panel. install cable
cover.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 10 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 4 April 2022
Resolved
Engine room ladder not secured at top; install hardware.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 10 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022
Resolved
Engine room FWD bulkhead outboard Port MDE; electrical cable dead ended; remove cable or terminate into a junction box.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 10 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2022
Resolved
Engine room Fire boy unit remote cable broken; repair or replace and provide 3rd party servicing documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2022
Resolution: Rectified in presence of CG MI: [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 4 April 2022
Resolved
Bow emergency escape hatch not labeled "EMERGENCY EXIT KEEP CLEAR".
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 April 2022
Resolved
Remote fire pump switch not labeled. Provide signage/ placard to identify switch.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 19 April 2022
Resolution: Veriified; [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 April 2022
Resolved
Distress flares not properly stowed, and missing (02)of the (06) required red flares.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2022
Resolution: Rectified in presence of MI: [name withheld]
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 April 2022
Resolved
Accommodation space E-lighting not operational;repair.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2022
Resolution: Rectified in presence of CG MI: [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 July 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel sustained damage to the hull on the port side midships. Damage appeared to be approximately 14 feet and approximately 3 feet above the water line as a gash impacting the FRP overlay and showing damage to both the outer and inner layers of plywood. Provide detailed damage survey and repair proposal. If vessel will transit to enact repairs, provide a transit plan to include temporary repairs, weather limitations, route and times of departure and arrival.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2021
Resolved 26 July 2021
Resolution: MI assessed damage in drydock and approved repair procedure
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 July 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel sustained damage to the hull on the port side midships. Vessel must conduct dry dock and made available to the attending MI to assess the damage prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 19 July 2021
Resolved 26 July 2021
Resolution: Vessel was drydocked and made avaialble to attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2021
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each aniversary date (10 January). Vessel is overdue for an annual inspection. Vessel must complete an annual inspection prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2021
Resolved 22 April 2021
Resolution: Conducted annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 2 November 2020
Resolved
A large fiberglass crack was identified on the stern of the vessel. The vessel is to be dry docked for inspection and repair. Provide a repair plan for approval by the attending USCG marine inspectors prior to conducting repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2021
Resolution: Sighted satisfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 21 April 2020
Resolved
Provide safety covers for 02 blowers in the steering gear room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2020
Resolved 28 May 2020
Resolution: provided photo evidence
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2020
Resolved
Provide electrical cover for open circuit in steering gear room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2020
Resolved 1 June 2020
Resolution: Circuit covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2020
Resolved
Refrigerator on upper deck wiring is an extension cord and J-box not attached to bulkhead. Remove extension cord wiring and replace with approve marine/boat cable and attach J-box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2020
Resolved 28 May 2020
Resolution: provided photo evidence
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2020
Resolved
Mount generator battery boxes located on outboard side of generators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2020
Resolved 28 May 2020
Resolution: provided photo evidence
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 April 2020
Resolved
Fire main has leak. Make repair to ensure no leak on fire main.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2020
Resolved 28 May 2020
Resolution: provided photo evidence
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 April 2020
Resolved
Provide markings for emergency fuel shut off.
Action required: 10 - Deficiency Rectified
Due 21 April 2020
Resolved 28 May 2020
Resolution: provided photo evidence
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 April 2020
Resolved
Provide required markings for emergency exit in accommodation spaces on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2020
Resolved 28 May 2020
Resolution: provided photo evidence
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 October 2019
Resolved
The closure for the starboard engine room air intake was inoperable. The closure needs to be repaired and able to close off the air intake in case the fixed fire system is activated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 8 October 2019
Resolution: Crew repaired closure.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 October 2019
Resolved
The electrical wiring in the engine room was not supported as required. Provide metallic wire supports at least every 24" on all wire runs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Vessel installed additional supports throughout engine room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 October 2019
Resolved
An unapproved power supply strip was located plugged into an outlet at the operating station. The power strip needs to be removed from the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 8 October 2019
Resolution: Crew removed power strip from vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 October 2019
Resolved
The 120 VAC electrical outlets throughout the vessel were not grounded. Provide proper sized 3 conductor wire to all outlets and ensure they are grounded.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 30 October 2019
Resolution: Vessel rewired outlets and demonstrated proper connection through use of a quick-check plug.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2019
Resolved
Combustible material was located within 3’ of a cooktop that operated over 250 degrees Fahrenheit. Provide B-15 material or remove all combustible material within 3' of the cooktop.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 30 October 2019
Resolution: Vessel installed stainless steel sheething around combustible material withing close proximity of cooktop.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2019
Resolved
The mattresses used in the passenger sleeping bunks were not flame retardant. Provide flame retardant treatment to the mattresses or provide new mattress's that meet the flame retardant requirements of new subchapter "T".
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 October 2019
Resolution: Vessel provided attestation as to installation date of mattresses (attached to activity) and confirmed application of "No-Burn" fire retardant spray.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 February 2019
Resolved
Provide current EPIRB registration and renew battery.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2019
Resolved 8 February 2019
Resolution: EPIRB registration and battery renewed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 February 2019
Resolved
Replace fire pump gauge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2019
Resolved 12 February 2019
Resolution: gauge replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2019
Resolved
Blank off empty breaker spots in eletrical panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2019
Resolved 12 February 2019
Resolution: Panel blanked off.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 February 2018
Resolved
PROVIDE EXTINGUISHER BRACKET IN GALLEY / E/R.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 8 February 2018
Resolution: BRACKET WAS PROVIDED.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 February 2018
Resolved
PROPERLY MARK FWD ESCAPE HATCH ON TOP.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 8 February 2018
Resolution: HATCH WAS MARKED.
Fire Fighting › Means of Escape › Blocked
Issued 6 February 2018
Resolved
PROVIDE TOOL AT FWD ESCAPE HATCH TO OPEN FROM THE DECK.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 6 February 2018
Resolution: TOOL PROVIDED ON THE SPOT.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 6 February 2018
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING IN BERTHING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 8 February 2018
Resolution: EMERGENCY LIGHTS ARE OPERATING PROPERLY.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 6 February 2018
Resolved
RENEW FCC SAFETY CERTIFICATE PRIOR TO EXPIRING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2018
Resolved 19 March 2018
Resolution: FCC safety certificate was renewed.
Construction/Loadline › Hull › Hull Plating
Issued 21 December 2016
Resolved
Remove delaminated plywood stbd forepeak and make proper repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Construction/Loadline › Hull › Hull Plating
Issued 21 December 2016
Resolved
Remove cracked/delaminated plywood in port crew quarters and make proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Construction/Loadline › Hull › Hull Plating
Issued 21 December 2016
Resolved
Remove delaminated plywood in port fwd berthing and incorporate missing plywood piece into proper repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Construction/Loadline › Hull › Hull Plating
Issued 21 December 2016
Resolved
Remove delaminated plywood in stbd aft berthing and make proper repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Operations/Management › Vessel Activity › Underway
Issued 21 December 2016
Resolved
Complete post-D/D check-ride.
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 10 January 2017
Construction/Loadline › Hull › Hull Plating
Issued 21 December 2016
Resolved
Dry and Epoxy plywood seems port side shell in aft berthing.
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Documentation › Markings/Placards › Lifejacket Placard
Issued 16 February 2016
Resolved
Post lifejacket donning placard.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 17 February 2016
Resolution: Lifejacket donning placard posted.
Electrical › Electric Supply System (service) › Battery Charger
Issued 16 February 2016
Resolved
Hard wire battery chargers.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 17 February 2016
Resolution: Battery chargers hard wired.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 16 February 2016
Resolved
Properly label switchboard (shore tie, Genset #1, Genset #2).
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 17 February 2016
Resolution: Switchboard properly labeled.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 February 2016
Resolved
Update NOAA registration for EPIRB.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 18 February 2016
Resolution: NOAA registration updated.