MAURY USCG vessel records Sign in
← All vessels

MARILINE

MARILINE is a 1996 tank ship. The Coast Guard has recorded 40 inspections since 1996, most recently in May 2019, along with 13 deficiencies and 12 operational controls.

Records from 1996 to 2019. Most recent: inspection, 3 May 2019.

Built
1996
Last inspected
3 May 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9135547 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
449930
Flag
NORWAY
—
Maury page id
psix-449930

Inspections, by type

…with no type recorded15
Years with a record 15 calendar years (1996–2019)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7336 - Convention (Subpart B), Net Ton
30553 - Dead Weight, Metric Ton
37605 - Displacement, Metric Ton
20043 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

3 May 2019 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6674371
9 May 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6410226
8 May 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5871643
25 April 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5858313
21 January 2016 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798666
1 May 2014 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4848019
13 July 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4377334
11 July 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4376005
10 December 2011 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4205654
18 October 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3872599
11 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3694190
10 March 2010 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3693101
5 March 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3690439
25 July 2009 MARPOL Annex II Examination · MARPOL Annex VI Survey · Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination · COC-CHEM Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3543451
29 January 2009 PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3401062
20 November 2008 Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3366761
11 August 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3295468
6 August 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3291056
5 August 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3290343
1 August 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3286092
3 July 2008 Ballast Water Examination · COC-CHEM Renew · ISPS III Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3253408
9 June 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3231660
12 May 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3204588
15 January 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3131407
19 June 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2967263
15 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2931322
11 March 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2885727
1 March 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2879847
28 February 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2879178
28 February 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2879674
6 August 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2737248
26 July 2006 ISPS II Exam · COC-CHEM Renew · Deficiency Check · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2725925
25 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2724853
5 April 2003 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1768647
4 May 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 289797
4 May 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1064378
13 February 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 412774
13 February 1998 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 776612
23 December 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 398814
23 December 1996 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1093672

Deficiency record · 13

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 April 2016 Resolved
1020-Fire Alarm-In all ships general arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the particulars of the fire detection and fire alarm systems. PSCO observed the arrangement of smoke and heat detectors on the vessel's third deck in the E/R did not match the fire control plan. SOLAS (97) II-2/20.1
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 May 2016
Resolved 8 May 2016
Resolution: PSC NOLA received a class statement from DNV satisfying the requirement.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 25 April 2016 Resolved
1899-Other(tankers)-No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, unless the Administration is satisfied that such equipment is appropriately certified for safe usage. PSCO observed fiberglass soft patches covering electrical cable piping on the vessel's cargo deck. SOLAS (04) II-1/45.10.4
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 May 2016
Resolved 8 May 2016
Resolution: PSC NOLA received a class statement from DNV satisfying the requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 July 2012 Resolved
All ships of 10,000 Gross Tonnage and upwards shall be fitted with a 3 GHz and 9 GHz radar, and should have ARPA capability. Vessel's primary radar with ARPA is non operational. (40 A, C) SOLAS 2009 CH V, Reg 19.2.8 / 33 CFR 164.37 & 33 CFR 164.38
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 July 2012
Resolution: Received Tech report atesting to the proper operation of the secondary radar.
Lifesaving › Launching Appliances › Release Mechanism
Issued 29 January 2009 Resolved
Starboard side life/rescue boat sheared the releasing mechanism wire, repairs were made by crew during the exam. The PSCO was unable to determine if the repair was effective. Provide report from the attending classification society proving the mechanism functions as designed.
Action required: 705 - Other - as specified
Due 5 February 2009
Resolved 31 January 2009
Resolution: Rcvd NKK class report stating wire renewed to correct length and mechanism performs as designed.
Lifesaving › Launching Appliances › Davit
Issued 29 January 2009 Resolved
The starboard life/rescue boat davits limit switch was inoperable.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 29 January 2009
Resolution: Repaired to the satisfaction of the attending PSCO while onboard.
Navigation › Piloting/Steering › Gyro Compass
Issued 11 August 2008 Resolved
This vessel was granted a deviation from the rules, allowing operation in the Sector New Orleans COTP zone with an inoperative gyro compass.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2008
Resolved 11 August 2008
Resolution: Received tech report from Sperry Marine stating that the gyro compass was repaired, satisfying requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 August 2008 Resolved
This vessel was granted a deviation from the rules, allowing operation in the Sector New Orleans COTP zone with an inoperative radar. Unable to make repairs at this port.
Action required: 15 - Rectify deficiencies by next port
Due 20 November 2008
Resolved 20 November 2008
Resolution: Received copy of SOLAS Cargo Ship Safety Equipment Certificate showing that a Survey was conducted on 21Aug08 certifying all safety equipment is operational.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 3 July 2008 Resolved
Audible overfill alarm on main deck failed to sound when overfill devices were tested.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 August 2008
Resolved 1 August 2008
Resolution: Received corrective action notice dated 08 JUL 08 stating horn was repaired on 08 JUL 08 and in good working order satisfying requirement.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 12 May 2008 Resolved
Received report of an inoperable anchor windlass on the vessels port anchor. Received a report from class attesting to the repairs made to the windlass anchor: the windlass anchor was determined to be found in working order after testing was concluded. Permanent repairs will be made no later than 04JUL08.
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 3 July 2008
Resolution: Repaired.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 15 May 2007 Resolved
Port side anchor is missing. Received class report from NKK, which has required repair no later than 21 JUN 07.
Action required: 705 - Other - as specified
Resolved 19 June 2007
Resolution: Received class report from Nippon kaiji Kyokai satisfying the requirement.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 11 March 2007 Resolved
Port side anchor is missing. NKK has a condition of class imposed requiring repair no later than 21 Apr 07. See SECNOLA Activity # 2879847 for details.
Action required: 705 - Other - as specified
Resolved 15 May 2007
Resolution: Received class report from NKK, extending the date of anchor repair to 21 JUN 07.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 26 July 2006 Resolved
Vessel is unable to demonstrate the proper operation of the Inert Gas System.
Action required: 705 - Other - as specified
Due 26 August 2006
Resolved 6 August 2006
Resolution: Received class survey. IGS system was operated by ship''s crew and observed by class surveyor.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 4 May 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 May 2001
Resolved 26 July 2006
Resolution: All License Valid.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.