MAURY USCG vessel records
← All vessels

TRITON

TRITON is a 1965 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2016, most recently in December 2025, along with 26 deficiencies, 1 operational control and 6 casualty investigations between 2000 and 2018.

Records from 2000 to 2025. Most recent: inspection, 8 December 2025.

Built
1965
Last inspected
8 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH4943
Flag
UNITED STATES
Maury page id
psix-45001

Inspections, by type

…with no type recorded3
Years with a record 10 calendar years (2016–2025)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)54.5 ft × 19.4 ft × 5.8 ft
Registered tonnagegross 52 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEORGE C CONRAD · SAN DIEGO, CA, UNITED STATES · built 1965
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 32

8 December 2025 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8279291
16 July 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8117605
30 April 2024 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7850708
18 April 2024 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7897635
5 March 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7874455
7 February 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7862072
13 January 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7838794
7 June 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7637943
3 April 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654639
23 February 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640823
27 November 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7596289
26 October 2022 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7602138
24 May 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7426857
29 March 2022 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7377166
12 November 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7350036
6 May 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7188541
1 October 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7069265
20 September 2020 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7070271
19 August 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7037570
7 April 2020 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6867512
15 October 2019 In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6822124
8 May 2019 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610279
27 March 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6670632
9 July 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6474000
9 July 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6476001
3 July 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6469869
3 April 2018 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6380588
9 January 2018 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6340677
14 June 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6169846
22 September 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6001466
22 September 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6007282
25 May 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5854318

Deficiency record · 26

07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 26 October 2022 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. Vessel has not submitted Watchmen Plans to the OCMI for review and approval. The carriage of overnight passengers is prohibited until vessel meets the requirements of 46 CFR 176.700.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2023
Resolved 1 May 2023
Resolution: Plan approved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 May 2022 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. MI identified fuel leak on both fuel/racor filters for SSDG,a s well as, plastic plugs in racor bowls. Vessel to fix/repair fuel leak and install metal plugs. 46CFR176.25-50
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Vessel completed satisfactory repairs and renewed plug with one of brass.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 24 May 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI identified two holes in bulkhead aft ER port side top. Vessel to make bulkhead watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 26 May 2022
Resolution: Vessel completed satisfactory repairs to bulkhead by blocking and making watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 May 2022 Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. MI identified missing hose clamps on flexible line for bilge system in ER. Vessel to install 2 new hose clamps.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2022
Resolution: Vessel installed 2 new hose clamps on flexible hose system prior to MI departing.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 November 2021 Resolved
Distress flares and smoke signals on an oceans route; a vessel must carry 6 hand red flares and 6 orange smoke. Vessel only had 3 orange smoke that were not expired, all others were expired. Vessel procured the rest of the smoke and flares prior to the inspection being over. Corrected on the spot. 46 CFR 180.68 (c).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 November 2021
Resolution: Vessel Captain was able to procure new smoke and flares before the inspection was complete.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 April 2020 Resolved
Provide repair and maintenance plan, due to weeping seams and decay, for starboard bilge space in the bunk compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2020
Resolved 12 May 2020
Resolution: Repairs made to weeping seam in bunk compartment, including recaulking of seam and additional support plate, were to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 December 2019 Resolved
All mattresses must comply with either the US Department of Commerce standard for mattress flammability FF 4-72.6, 16 CFR Part 1632 sub part A ad not contain polyurethane foam or IMO Resolution A.688(17) and may contain polyurethane foam. Submit a plan proposal to replace non-compliant mattresses with compliant mattresses.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 20 September 2020
Resolution: Vessel owner submitted plan to replace matrresses onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 October 2019 Resolved
Demonstrate compliance with either the US Department of Commerce standard for mattress flammability FF 4-72.6, 16 CFR Part 1632 sub part A and not contain polyurethane foam or IMO resolution A.688(17) and may contain polyurethane foam or remove/replace all mattresses on board with compliant mattresses. 46 CFR 177.405
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Clear deficiency and issued another deficiency for plan proposale on replacement of non-compliant mattresses.
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 15 October 2019 Resolved
Various Bunks do not meet minimum measurement requirements. Reduced passenger accomodations to 15. 46CFR 177.30-7(OLD T)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2019
Resolved 31 October 2019
Resolution: Owner rectified dimensions for height of bunk spacing. Increased passenger overnight accommodations to 25.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2019 Resolved
Vessel needs to replace galley trash can with metal or non combustible trash can if kept next to galley stove. 46CFR177.30-7(OLD T)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 31 October 2019
Resolution: Owner replaced trash can with metal trash can.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 15 October 2019 Resolved
Vessel needs to conduct abandonship drills. 46CFR185.520
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 31 October 2019
Resolution: Abandonship drills were conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 October 2019 Resolved
Lanyards on lifefloats lights need to be replace with proper line. 46CFR180.150
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 31 October 2019
Resolution: Lanyard on floating water lights have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 October 2019 Resolved
Life Floats are connected together and are not individually attached to the painter. 46CFR180.137
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 31 October 2019
Resolution: Each life float is individually connected to the painter/weak link.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 October 2019 Resolved
Galley griddle does not have a fixed fire extingushing system. 46 CFR 181.405
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 31 October 2019
Resolution: Vessel does not need to meet 46 CFR 181.405/181.425 if vessel is in compliance with policy letter dated 26Feb2019 GREASE EXTRACTION HOODS ON EXISTING VESSELS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2019 Resolved
Found Extinguisher to be discharged. Remove extinguisher from vessel. Extinguisher is in excess of that required on COI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 May 2019
Resolved 8 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 May 2019 Resolved
Make bulkhead between LAZ and Void space watertight where new wiring penetrates the bulkhead.
Action required: 10 - Deficiency Rectified
Due 8 May 2019
Resolved 8 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 May 2019 Resolved
Make bulkhead between Void space and engine room watertight where new wiring penetrates bulkhead.
Action required: 10 - Deficiency Rectified
Due 8 May 2019
Resolved 8 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 May 2019 Resolved
Weak links on all four life floats found to be secured to float by a carribeaner. Prove proper installation of weak link for all life floats.
Action required: 10 - Deficiency Rectified
Resolved 8 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2019 Resolved
Replace retroreflective material on three child lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 May 2019
Resolved 8 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2019 Resolved
Replace two non-functional waterlights on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 May 2019
Resolved 8 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2019 Resolved
Remove exposed plastic wire nuts used for line splicing in wiring in holding tank space.
Action required: 10 - Deficiency Rectified
Due 8 May 2019
Resolved 8 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 May 2019 Resolved
All floating waterlights found to be attached to the life floats via the painter instead of around the body of the life float. Prove proper installation of waterlights for life floats.
Action required: 10 - Deficiency Rectified
Due 8 May 2019
Resolved 8 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 July 2018 Resolved
Prove proper operation of port engine or provide auxiliary means of steering - to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2018
Resolution: Conducted satisfactory operational tests of port engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 July 2018 Resolved
INSTALL CHECK VALVES ON THE LAZ, FUEL ROOM, AND BUNKROOM BILGE LINES. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR. 46CFR182.510(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 August 2018
Resolved 10 July 2018
Resolution: Vessel installed check valves on lazarette, fuel space, and bunk room lines.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 January 2018 Resolved
Prove proper operation of vital systems related to water tight integrity.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 January 2018
Resolved 23 January 2018
Engineering › Steering Gear System › Rudder
Issued 25 May 2016 Resolved
Replace STBD rudder post support as per 46CFR182.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 May 2016
Resolution: Rudder post satisfactorly installed

Casualty record · 6

24 March 2000Routine · role: Suspected to be in Violation of Law or Reg · activity 1608452
18 June 2005Routine · role: Subject to Marine Inspection · activity 2407658
14 June 2006Routine · role: Involved in a Marine Casualty · activity 2684861
16 August 2007Routine · role: Involved in a Marine Casualty · activity 3053386
30 July 2011Routine · role: Involved in a Marine Casualty · activity 4100476
9 July 2018Routine · role: Involved in a Marine Casualty · activity 6476001
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GALLILEAN (2000–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.