MAURY USCG vessel records Sign in
← All vessels

LOUISE LYKES *

LOUISE LYKES * is a 1965 freight ship. The Coast Guard has recorded 98 inspections since 1982, most recently in April 1995, along with 36 deficiencies.

Records from 1982 to 1995. Most recent: inspection, 17 April 1995.

Built
1965
Last inspected
17 April 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6504797 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DELETE 123
Flag
UNITED STATES
366224000 (licence lapsed)
Maury page id
psix-45010

Inspections, by type

…with no type recorded64
Years with a record 14 calendar years (1982–1995)
The 98 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7423 - Dual (D), Gross Ton
10954 - Regulatory (Subpart C or D), Gross Ton
4008 - Dual (D), Net Ton
6324 - Regulatory (Subpart C or D), Net Ton
15295 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WLCVMMSI 366224000 · expired · compulsorily equipped · granted 19 August 1991, cancelled 19 August 1996
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 98

17 April 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849038
23 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 95405
3 October 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466364
25 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 89690
13 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141210
19 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 20086
4 May 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 90965
22 March 1994 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453021
9 December 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397991
29 October 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 216721
19 October 1993 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 696358
3 July 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401727
28 June 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 218977
17 June 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 451467
17 June 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1134664
20 April 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 217925
8 April 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 661472
30 March 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 104214
26 March 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 661467
15 March 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 842172
12 January 1993 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 661469
22 December 1992 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 826521
21 December 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 20140
10 December 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469088
23 November 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 497150
15 November 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 503952
21 August 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 945939
11 August 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 60021
30 July 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 661463
21 July 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 70916
25 June 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376876
24 June 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 661455
17 June 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1465717
6 June 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 25386
5 June 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1263036
4 June 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 536018
4 June 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1473294
2 June 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 70921
18 May 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1258001
25 March 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1265593
22 March 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 46359
22 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 173864
20 March 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1255847
11 March 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 482897
5 March 1992 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1317955
10 February 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954224
27 January 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954152
10 December 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1255753
27 November 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 939187
12 November 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 478362
14 July 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940909
13 January 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1224592
24 December 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233956
11 October 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216661
25 May 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1214992
16 May 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216156
22 November 1989 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 463453
10 July 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331388
20 June 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1353107
14 June 1989 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1033511
24 February 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1042408
21 February 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1195046
15 February 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1038607
7 February 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 888347
27 November 1988 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 887375
8 August 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1039671
5 August 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1343945
3 August 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1034402
20 May 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353145
13 May 1988 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1350911
10 January 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 320650
23 July 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328570
13 July 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 531099
1 May 1987 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1016357
7 January 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 313649
30 October 1986 MARPOL Annex I Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1320367
5 June 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 489509
29 May 1986 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1299714
21 March 1986 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996728
21 March 1986 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004862
25 January 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 306556
16 November 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 474053
12 November 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 516007
11 September 1985 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 989267
7 September 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 486200
9 May 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1289079
8 May 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1306967
22 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981267
14 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 974821
10 February 1985 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 300306
27 January 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 487152
3 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974493
25 April 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280905
23 April 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 974163
12 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969679
12 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276373
2 August 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1279405
29 July 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967700

Deficiency record · 36

Electrical
Issued 3 October 1994 Resolved
PRIOR TO DEPARTURE FROM PORT, PROVE PROPER OPERATION OF #2 GENERATOR OVERSPEED.
Condition: Unknown
Due 7 October 1994
Resolved 11 October 1994
Lifesaving
Issued 3 October 1994 Resolved
PRIOR TO DEPARTURE FROM PORT, CONDUCT SATISFACTORY BOAT DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 October 1994
Resolved 11 October 1994
Construction/Loadline
Issued 22 March 1994 Resolved
VSL IS RESTRICTED FROM USING #5 CENTERLINE DOUBLE BOTTOM SLOP TANK UNTIL PERMINANT REPAIRS ARE MADE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 31 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 9 December 1993 Resolved
INSTALL A PULL CABLE AND CABLE HOUSING FOR FORECASTLE CO2 SYSTEM.
Condition: Unknown
Due 9 December 1993
Resolved 9 December 1993
Fire Fighting
Issued 9 December 1993 Resolved
REPAIR SMOKE DETECTING CABINENT TROUBLE LIGHT IN CO2 ROOM AND DEMONSTRATE PROPEROPERATION OF SAME.
Condition: Unknown
Due 9 December 1993
Resolved 9 December 1993
Documentation
Issued 17 June 1993 Resolved
MAINTAIN A SEPARATE LOG OF EACH TIME AND DURATION OF PUMPING THE ENGINEROOMBILGES UNTIL PERMANENT REPAIRS ARE COMPLETED TO THE NO.2 GENERATOR SEA SUCTION.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Construction/Loadline
Issued 17 June 1993 Resolved
PROCCED TO THE SHIP YARD AND REMOVE CEMENT BOX AND MAKE READY FOR INSPECTION THE NO.2 GENERATOR LOW SEA SUCTION 10" NOZZLE ASSEMBY. THE INSPECTION AND REPAIRS SHALL BE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTION.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Lifesaving
Issued 10 December 1992 Resolved
MAKE STBD LIFEBOAT AVAILABLE FOR WEIGHT TEST. TEST TO BE CONDUCTED IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 10 December 1992
Resolved 10 December 1992
Electrical
Issued 17 June 1992 Resolved
TEST ALL ELECTRICAL WIRING, MOTORS, CIRCUIT BREAKERS AND FUSES ON CARGO WINCH 2C3 CIRCUIT. VESSEL SHALL SUBMIT A LETTER TO [name withheld] ALL ITEMS STILL MEET REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE OR 46 CFRSUBCHAPTER J.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Electrical
Issued 17 June 1992 Resolved
SUBMIT PLANS FOR REPLACING WIRE NUMBER 1 P-202 1-A.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Construction/Loadline
Issued 4 June 1992 Resolved
PRIOR TO LOADING CARGO; CLEAN OIL FROM STARBOARD SIDE OF VESSEL'S HULL TO PREVENT AN OIL POLLUTION INCIDENT. THIS ITEM TO BE ACCOMPLISHED TO THE SATISFACTION OF THE COGNIZANT OCMI AND PRIOR TO DEPARTURE FROM SAN FRANCISCO BAY, CALIFORNIA.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Engineering
Issued 4 June 1992 Resolved
PROPERLY REPAIR SUPERHEATER VENT ROOT VALVE ON STARBOARD BOILER. THIS ITEMIS TO BE ACCOMPLISHED TO THE SATISFACTION OF THE COGNIZANT OCMI AND PRIOR TO DEPARTURE FROM SAN FRANCISCO BAY, CALIFORNIA.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Engineering
Issued 4 June 1992 Resolved
PROPERLY TEST, MARK AND RECORD RESULTS OF TRANSFER HOSE IN ACCORDANCE WITH 33 CFR 155.800. THIS ITEM IS TO BE ACCOMPLISHED TO THE SATISFACTION OF THECOGNIZANT OCMI AND PRIOR TO DEPARTURE FROM SAN FRANCISCO BAY, CALIFORNIA.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Construction/Loadline
Issued 4 June 1992 Resolved
PROPERLY REPAIR OILY BALLAST SUCTION VALVE STARBOARD SIDE MAINFOLD #16. THIS ITEM TO BE ACCOMPLISHED PRIOR TO DEPARTING SAN FRANCISCO BAY, CALIFORNIA AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Navigation
Issued 25 March 1992 Resolved
VESSEL ARRIVED PORT OF LAKE CHARLES, LOUISIANA WITH BOTH RADARS INOP. VESSEL GIVEN LETTER OF DEVIATION TO ENTER PORT AND MAKE PERMENANT REPAIRS PRIOR TO DEPARTURE. BOTH RADARS OPERATIONAL UPON DEPARTURE.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Engineering
Issued 27 November 1991 Resolved
TEST RELIEF VALVES FOR DC HEATER AND CONTAMINATED EVAPORATOR WHILE UNDERWAY, LOG IN LOG BOOK AND MAIL COPY TO MSO S.F. BAY.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Construction/Loadline
Issued 27 November 1991 Resolved
REMOVE AND REPLACE ALL NON-METALIC EXPANSION JOINTS.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Engineering
Issued 27 November 1991 Resolved
COMPLETE AUTOMATION TEST PROCEDUREWS: SECTIONS 1(A) TO 1(E) AND 5(A) TO 5(E), OR REVISE TEST PROCEDURES FOR 2 MAN ENGINE ROOM WATCH.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Electrical
Issued 27 November 1991 Resolved
PROVIDE A LOW LUBE OIL PRESSURE TRIP FOR THE EMERGENCY GENERATOR AND MAKE AVAILABLE FOR TESTING WITH A MARINE INSPECTOR PRESENT; OR PROVIDE EVIDENCE TO THE [name withheld] THAT THE VESSEL'S EMERGENCY GENERATOR DOES NOT NEED THE TRIP.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Engineering
Issued 27 November 1991 Resolved
REPLACE FUEL VENT HEAD ON #5 STB DEEP FUEL TANK.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Lifesaving
Issued 27 November 1991 Resolved
INSTALL LIFERAFTS, SO AS TO COMPLY WITH SOLAS REGULATIONS 13 AND 15, AS FORSTOWAGE, LAUNCHING TIME AND EASE. TO ALSO INCLUDE EMARKATION ILLUMINATION.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Electrical
Issued 27 November 1991 Resolved
INSERT BLANK OVER EXSPOSED WIRE CONNECTIONS ON PANEL #1-67-1 ( INSIDE #3 DECKHOUSE).
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Navigation
Issued 10 July 1989 Resolved
33CFR164.37(A) VESSEL ENTERED THIS PORT WITH SECONDARY RADAR NOT OPERATING PROPERLY AS REQUIRED BY 33CFR164.11(R). LETTER OF DEVIATION ISSUED FOR ENTRY. RADAR REPAIRED PRIOR TO DEPARTURE THIS PORT.
Condition: Unknown
Due 10 July 1989
Resolved 10 July 1989
Navigation
Issued 14 June 1989 Resolved
MAKE 3CM NAVIGATIONAL RADAR ON BRIDGE OPERATIONAL.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Documentation
Issued 5 August 1988 Resolved
OBTAIN CARGO GEAR SAFETY CERTIFICATE.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Engineering
Issued 3 August 1988 Resolved
E1 PERFORM OPERATIONAL TEST OF SPEED CONTROL GOVERNOR ON BOTH COFFIN FEED PUMPS UNDER MAX ATTAINABLE LOAD CONDITIONS. C/E TO FURNISH LETTER TO [name withheld] PROPER OPERATION.
Condition: Unknown
Due 3 August 1988
Resolved 3 August 1988
Construction/Loadline
Issued 13 May 1988 Resolved
E2 PROVIDE DOCUMENTATION THAT EXPANSION JOINTS HAVE BEEN REPLACED WITHIN THE LAST 10 YEARS.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Engineering
Issued 13 May 1988 Resolved
E1PROVIDE DOCUMENTATION OF FEED PUMPS OVERSPEED TRIPS BEING TESTED WITHIN THE LAST 5 YEARS.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Documentation
Issued 1 May 1987 Resolved
D2 PROVIDE TRAINING MANUAL AS PER SOLAS 83 AMENDMENTS; CHAPTER 3; PART 8; REGULATION 51 PRIOR TO 01 JULY 1987.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Construction/Loadline
Issued 22 February 1985 Resolved
RENEW BILGE AND BALLAST OVERBOARD SPOOLPIECE AT THE VESSELS NEXT SCHEDULED DRYDOCK TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Lifesaving
Issued 14 February 1985 Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY REPAIRS MADE ON STARBOARD LIFEBOAT HULLIN WAY OF FOURTH FASTENER ON HANDRAIL (PORT SIDE).
Condition: Unknown
Due 14 February 1985
Resolved 14 February 1985
Lifesaving
Issued 14 February 1985 Resolved
MAKE PERMANENT REPAIRS TO TAMPORARY REPAIRS MADE ON PORT LIFEBOAT HULL IN WAY OF THIRD FASTENER ON HNDRAIL PORT SIDE.
Condition: Unknown
Due 14 February 1985
Resolved 14 February 1985
Unknown
Issued 3 July 1984 Resolved
THE FOLLOWING DEFICIENCIES PRETAIN TO THE VESSEL LOUISE LYKES, 299938 AND ARE TO BE COMPLIED BY 29JUL84
Condition: Unknown
Due 3 July 1984
Resolved 3 July 1984
Construction/Loadline
Issued 3 July 1984 Resolved
CROP AND RENEW SET IN PORT SIDESHELL PLATE H-8 (FULL WIDTH) FROM EXISTING BUTT AT FRAME 731/2 TO NEW BUTT AT FRAME 801/2 ALSO RENEW ASSOCIATED INTERNALS HEAT.
Condition: Unknown
Due 3 July 1984
Resolved 3 July 1984
Unknown
Issued 12 May 1983 Resolved
SAILING FOREIGN
Condition: Unknown
Due 20 May 1983
Resolved 12 May 1983
Lifesaving
Issued 12 May 1983 Resolved
CONDUCTED WEIGHT TEST OF STARBOARD LIFEBOAT IAW 46 CFR 91.25-15. TEST TO BECONDUCTED TO THE COGNIZANT OCMI AND NOT LATER THAN 20MAY83 OR BEFORE
Condition: Unknown
Due 20 May 1983
Resolved 12 May 1983

Ownership record